Other Temperature and Humidity Measurement Instruments
Filter
Showing 31–50 of 50 results
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 211 |
| Temperature Range | 1.4 K to 800 K |
| Input Channels | 1 |
| Sensor Types Supported | Silicon Diode, GaAlAs Diode, 100 Ω Pt, 1000 Ω Pt, Carbon-Glass, Cernox®, Rox™ |
| A/D Resolution | 24-bit |
| Measurement Update Rate | 7 Hz |
| Display Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Display | 5-digit LED |
| Output Options | 0–10 V, 4–20 mA, Relay, RS-232/RS-485 Serial Interface |
| User Calibration Curves | 1 × 200-point non-volatile memory |
| Excitation Method | Constant-current, 4-wire differential |
| Isolation | Not chassis-ground isolated |
| Compliance | Designed for cryogenic vacuum and magnetic field environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 218 |
| Input Channels | 8 |
| Sensor Compatibility | Diode (Si, GaAlAs) and Resistance (Pt100, Pt1000, Germanium, Carbon-Glass, Cernox®, Rox™) |
| Temperature Range | 1.2 K to 375 K |
| Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Update Rate | 16 readings/s total (2 full scans of all 8 channels per second) |
| Calibration Curves | 8 × 200-point user-definable curves |
| SoftCal™ Support | DT-470 diode (30–375 K, ±0.25 K improvement), Pt resistance (70–325 K, ±0.25 K improvement) |
| Interfaces | IEEE-488 (GPIB), RS-232C, dual analog voltage outputs, 8 relay outputs |
| Display | 4-line × 20-character backlit LCD |
| Excitation | 8 independent constant-current sources, 4-wire differential measurement |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 224 |
| Sensor Channels | 12 (2 dedicated, 10 multiplexed) |
| Operating Range | 300 mK to 375 K |
| Input Types | Cernox®, silicon diodes (e.g., DT-670), Pt RTDs (100 Ω / 1000 Ω), Rox™, germanium, carbon-glass |
| A/D Resolution | 24-bit |
| Update Rate | up to 10 readings/s (dedicated channels), 1–2 readings/s (scanned channels) |
| Isolation | optical isolation between sensor inputs and system ground |
| Calibration Storage | 39 user-defined 200-point curves |
| Display | 240 × 64 pixel LCD (8 × 40 characters), LED backlit |
| Interface | front-panel 6-pin DIN connectors |
| Compliance | designed for GLP/GMP-aligned lab environments |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | V-2156-X |
| Certification | ISO/IEC 17025 (A2LA & UKAS accredited) |
| Traceability | NIST-traceable |
| Application | Calibration reference for black panel temperature sensors in accelerated weathering testers |
| Replacement part type | Field-replaceable sensor assembly |
| Compatibility | QUV accelerated UV weathering testers and Q-SUN xenon arc test chambers |
| Brand | RM Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Sensor Type | 1000 Ω Pt RTD (Class A) |
| Output Options | 4-wire Pt RTD / 0–1 VDC (5 mA, 8–24 VDC supply) / 4–20 mA (20 mA, 12–30 VDC supply) |
| Temperature Range | –50 to +50 °C |
| Calibration Accuracy at 0 °C | ±0.3 °C (NIST-traceable certificate included) |
| Optional Enhanced Accuracy | ±0.1 °C |
| Recommended Radiation Shields | Gill 41003P Passive Multi-Plate Shield or 43502 Active Ventilated Shield |
| Compliance | NIST-traceable calibration, ISO/IEC 17025-compliant calibration procedures |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2160 |
| Sensor Compatibility | PMA2161, PMA2162, PMA2163, PMA2164 |
| Temperature Range (varies by probe) | −40 to +150°C |
| Accuracy | ±0.35°C (within 0–70°C) |
| Long-term Stability | <0.02°C/year |
| Self-heating Power | <100 µW |
| Resolution | 0.1°C / 0.1°F / 0.1 K |
| Output Units | °C, °F, K |
| Cable Length | 1.2 m (4 ft) |
| Calibration Method | Embedded Steinhart-Hart coefficients |
| Interface Connector | RJ12 |
| Memory | Onboard non-volatile memory storing probe-specific calibration data |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0516 1901 |
| Dimensions (L×W×H) | 340 × 265 × 60 mm |
| Weight | 1130 g |
| Housing Material | High-strength plastic |
| Interface | USB |
| Capacity | Simultaneous programming and readout of up to 8 compatible Testo data loggers |
| Software | Not included — sold separately |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1900 |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Operating Temperature | 0 °C to 140 °C |
| Storage Temperature | −20 °C to +50 °C |
| Housing | Stainless Steel & PEEK |
| IP Rating | IP68 |
| Battery | 1/2 AA Lithium |
| Battery Life | 2,500 h (10 s measurement interval at +121 °C) |
| Memory Capacity | 60,000 values |
| Measurement Interval | 1 s to 24 h |
| Dimensions | Ø22 mm × 83 mm |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1901 |
| Operating Temperature | −50 to +140 °C |
| Probe Length | 25 mm |
| Probe Diameter | 3 mm |
| Housing Dimensions | Ø20 × 59 mm |
| Enclosure Material | Stainless Steel + PEEK |
| IP Rating | IP68 |
| Sensor Type | Pt1000 |
| Measurement Accuracy | ±0.1 °C (−40 to +140 °C), ±0.2 °C (−50 to −40 °C) |
| Resolution | 0.01 °C |
| Memory Capacity | 60,000 readings |
| Sampling Interval | 1 s to 24 h |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (at 10 s interval, +121 °C) |
| Storage Temperature | −20 to +50 °C |
| Response Time (t₉₀) | 7 s |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1902 |
| Measurement Principle | Pt1000 Resistance Thermometry |
| Temperature Range | –50 to +140 °C |
| Accuracy | ±0.1 °C (–40 to +140 °C), ±0.2 °C (–50 to –40 °C) |
| Resolution | 0.01 °C |
| Response Time t₉₀ | 6 s |
| Probe Length | 115 mm |
| Probe Diameter | 3 mm |
| Device Dimensions | Ø20 × 59 mm |
| Enclosure Material | Stainless Steel + PEEK |
| IP Rating | IP68 |
| Memory Capacity | 60,000 readings |
| Sampling Interval | 1 s to 24 h |
| Battery | 1/2 AA Lithium |
| Operating Life | 2,500 h (at 10 s cycle, +121 °C) |
| Compliance | FDA 21 CFR Part 11 (with testo 190 CFR Software), EU CE Marked |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1903 |
| Measurement Principle | Pt1000 Resistance Thermometry |
| IP Rating | IP68 |
| Operating Temperature | -50 °C to +140 °C |
| Accuracy | ±0.1 °C (-40 °C to +140 °C), ±0.2 °C (-50 °C to -40 °C) |
| Resolution | 0.01 °C |
| Response Time (t₉₀) | 6 s |
| Probe Length | 775 mm |
| Probe Diameter | 1.5 mm |
| Probe Tip Diameter | 3 mm |
| Memory Capacity | 60,000 data points |
| Battery Life | 2,500 h (10 s cycle at +121 °C) |
| Housing Dimensions | Ø20 × 63 mm |
| Enclosure Material | Stainless steel + PEEK |
| Battery Type | 1/2 AA lithium |
| Storage Temperature | -20 °C to +50 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1904 |
| Probe Length | 775 mm (each) |
| Probe Diameter | 1.5 mm |
| Operating Temperature Range | -50 °C to +140 °C |
| Measurement Accuracy | ±0.1 °C (-40 °C to +140 °C), ±0.2 °C (-50 °C to -40 °C) |
| Resolution | 0.01 °C |
| Response Time (t₉₀) | 6 s |
| Memory Capacity | 30,000 readings per channel |
| IP Rating | IP68 |
| Enclosure Material | Stainless steel housing with PEEK battery cap |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (10 s sampling at +121 °C) |
| Dimensions | Ø20 × 72 mm |
| Compliance | Designed for FDA 21 CFR Part 11–compliant validation workflows |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1916 |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Operating Temperature | 0 °C to 140 °C |
| Storage Capacity | 60,000 measurements |
| Measurement Interval | 1 s to 24 h |
| Housing Material | Stainless steel (AISI 316L) + PEEK cap |
| IP Rating | IP68 |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (at 10 s interval, +121 °C) |
| Dimensions | Ø22 mm × 83 mm |
| Interface | USB |
| Compliance | CE-marked, HACCP-compliant, designed for EN 13485 / ISO 13485-aligned validation environments |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1911 |
| Measurement Principle | Pt1000 Resistance Thermometry |
| Temperature Range | -50 to +140 °C |
| Accuracy | ±0.1 °C (-40 to +140 °C), ±0.2 °C (-50 to -40 °C) |
| Resolution | 0.01 °C |
| Storage Capacity | 60,000 measurements |
| IP Rating | IP68 |
| Probe Dimensions | Ø3 mm × 25 mm |
| Device Dimensions | Ø20 mm × 59 mm |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 h (at 10 s interval, +121 °C) |
| Response Time t₉₀ | 7 s |
| Enclosure Material | Stainless steel housing with PEEK sealing ring |
| Compliance | CE-marked, HACCP-compliant, suitable for FDA-regulated food processing environments |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1912 |
| Measurement Range | -50 to +140 °C |
| Accuracy | ±0.1 °C (-40 to +140 °C), ±0.2 °C (-50 to -40 °C) |
| Resolution | 0.01 °C |
| Sensor Type | Pt1000 |
| Probe Length | 115 mm |
| Probe Diameter | 3 mm |
| Device Dimensions | Ø20 × 59 mm |
| IP Rating | IP68 |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (at 10 s interval, +121 °C) |
| Memory Capacity | 60,000 values |
| Measurement Interval | 1 s – 24 h |
| Operating Temperature | -50 to +140 °C |
| Storage Temperature | -20 to +50 °C |
| Enclosure Material | Stainless steel housing with PEEK-coated battery cap |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0572 1913 |
| Measurement Range | -50 to +140 °C |
| Accuracy | ±0.1 °C (-40 to +140 °C), ±0.2 °C (-50 to -40 °C) |
| Resolution | 0.01 °C |
| Probe Length | 775 mm, Tip Diameter: 3 mm, Shaft Diameter: 1.5 mm |
| Response Time (t₉₀) | 6 s |
| Memory Capacity | 60,000 readings |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 h (at 10 s interval, +121 °C) |
| IP Rating | IP68 |
| Housing Material | Stainless steel body with PEEK-coated battery cap |
| Dimensions | Ø20 × 63 mm |
| Storage Temp. | -20 to +50 °C |
| Compliance | CE-marked, HACCP-compliant design |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0572 1914 |
| Measurement Principle | Dual-channel Pt1000 resistance thermometry |
| Temperature Range | −50 °C to +140 °C |
| Accuracy | ±0.1 °C (−40 °C to +140 °C), ±0.2 °C (−50 °C to −40 °C) |
| Resolution | 0.01 °C |
| Storage Capacity | 30,000 readings per channel |
| Probe Length | 775 mm |
| Probe Diameter | 1.5 mm |
| Device Dimensions | Ø20 mm × 72 mm |
| IP Rating | IP68 |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 h (10 s sampling at +121 °C) |
| Enclosure Material | Stainless steel housing with PEEK-coated battery cap |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 01STHE□ |
| Pricing | Available Upon Request |
| Accuracy | ±1 °C below 100 °C |
| Compliance | BS EN ISO 9001 certified |
| Dimensions | 12 × 13 mm per strip |
| Pack Size | 50 strips per pack |
| Format | Vertical self-adhesive format with dual-scale (°C and °F) markings |
| Temperature Range Options | 29–290 °C (discrete points: 29, 33, 34, 37, 40, 42, 43, 44, 46, 49, 54, 60, 62, 65, 71, 77, 82, 88, 93, 99, 104, 110, 116, 121, 127, 132, 138, 143, 149, 154, 160, 166, 171, 177, 182, 188, 193, 199, 204, 210, 216, 224, 232, 241, 249, 254, 260, 280, 290 °C) |
| Chemical Resistance | Oil-resistant and water-resistant |
| Toxicity | Non-hazardous, non-toxic formulation |
| Indication Mechanism | Irreversible thermochromic color transition (white → black) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5-Grid & 8-Grid Format |
| Pricing | Available Upon Request |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | CURVE-X2 |
| Temperature Range | –50 °C to 1200 °C |
| Accuracy | ±0.3 °C |
| Resolution | 0.1 °C |
| Thermocouple Type | NiCr–Ni (Type K) |
| Probe Inputs | 6–12 channels |
| Operating Temperature | 0–60 °C |
| Sampling Interval | 1 second to 1 hour |
| Memory Capacity | 254,000 data points (10 user-definable groups, 25,000 points per group) |
| Power Supply | 3 × AA 1.5 V alkaline batteries (up to 1200 hours continuous logging) |
| Dimensions (Logger) | 30 × 105 × 85 mm (H × L × W) |
| Weight (Logger) | 285 g |
| Insulation Box Dimensions | 66 × 192 × 145 mm (H × L × W) |
| Insulation Box Weight | 1600 g |
| Predefined Coating Profiles | 15 |
| Curve-Index Calculation | Built-in |
| Display | Backlit graphical LCD |
| Auto-Start/Stop Triggers | Time/date-based or temperature-threshold-based |
| Software | Ideal Finish™ (included) |