Empowering Scientific Discovery

Perten Instruments (PerkinElmer)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelDA7440
Instrument TypeOnline
PrincipleGrating Scanning
Wavelength Range950–1650 nm
Scan Speed30 subspectra/sec
Data Sampling IntervalUser-Configurable
Measurement ModeDiffuse Reflectance / Transflectance
Chemometrics SoftwareUnscrambler X, Percal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelIM 8800
Instrument TypePortable
Application FieldCereals & Oilseeds
Measurement PrincipleGrating-based diode array (non-scanning)
Wavelength Range850–1050 nm
Scan Time20 seconds
Data Sampling Interval5 nm
Measurement ModeTransmission
Chemometrics SoftwareUnscrambler®
GPS IntegrationYes
Power Supply12 V DC or internal rechargeable battery (2 h runtime)
ComplianceAACC Method 39-25
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginImported
ModelRVA 4500
Viscosity Range20–50,000 cP (at 80 rpm)
Measurement Time3 min (stirring value)
Sample Mass2–3 g
ComplianceGB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997)
SoftwareThermocline for Windows (TCW3)
Drive SystemBrushless DC motor
Temperature ControlProgrammable ramping and holding (4–130 °C)
Shear ControlVariable rotational speed (up to 160 rpm)
Data OutputTime-temperature-viscosity profiles with automated parameter extraction (onset, peak, breakdown, setback, final viscosity)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelDA7250
Instrument TypeLaboratory
PrincipleGrating-based non-scanning diode array spectrometry
Wavelength Range950–1650 nm
Scan Speed100 spectra/sec
Data Sampling Interval0.008 s
Measurement ModeDiffuse Reflectance
Chemometrics SoftwareUnscrambler
DetectorThermoelectrically Cooled InGaAs Diode Array
Optical ResolutionAdjustable from 0.1 nm to 10 nm
Spectral Bandwidth~7 nm
Wavelength Accuracy<0.05 nm
Wavelength Repeatability<0.02 nm (per measurement), <0.2 nm/year
Absorbance Range0–2.5 AU
Noise Level<20 µA (10 s continuous acquisition)
Light Source Lifetime>10,000 h
Operating Temperature0–40 °C
IP RatingIP65
Sample Weight Capacity0.5–300 g (solids), 2–100 mL (liquids)
Standard Sample Area154 cm² (large cup), 44 cm² (small cup)
Analysis Time≤6 s per sample
Measurement GeometryNon-contact rotating scan
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelFN1000
ComplianceASTM/ICC/AACC/ISO/GB Standards
Sample TypeWheat, Durum, Rye, Barley, Flour, and Other Cereal Grains
Measurement PrincipleViscosity-based enzymatic hydrolysis kinetics (Hagberg-Perten method)
Temperature ControlPrecise 100 °C water bath with auto-leveling system
Dispensing Accuracy25.0 ± 0.2 mL deionized water per test
Display5.7″ color touchscreen with multilingual UI (including Chinese)
ConnectivityUSB 2.0 + Ethernet (RJ45) for LIMS integration, barcode readers, and thermal printers
Altitude CompensationAutomatic correction above 610 m (2000 ft) ASL
Dual-Mode OperationStandard Falling Number (FN) and Fungal Falling Number (FFN) via firmware switch
Data ManagementSample ID registration, moisture-corrected reporting, audit-ready result logs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelLM120
Sample TypeHard, granular, and fibrous materials (e.g., cereals, feed, meat)
Feed Size40–80 mesh
Output Particle Size0.5–2.0 mm (standard sieve: 0.8 mm)
Batch Capacity≤300 g
Rotor Speed16,800 rpm
Grinding Time30–50 s per 300 g batch
Noise Level≤75 dB(A) with acoustic enclosure
Power Supply110–440 V, 1/3-phase, 50/60 Hz, 1.1 kW
Dimensions545 × 460 × 240 mm
Optional Accessories3170 Motorized Feeder
ComplianceDesigned for GLP-compliant laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginFinland
Model3310 and 3600
Sample TypeHard, low-fat grains (≤20% fat)
Feed Size40–80 mesh
Output Particle Size≥0.5 mm
Batch Capacity≤150 g
Grinding Disc Diameter75 mm (3310), 100 mm (3600)
Motor Power0.5 kW
Voltage/Frequency110/220/440 V, 50/60 Hz, single- or three-phase
Net Weight33 kg (3310), 34 kg (3600)
Dimensions (L×W×H)440×550×260 mm (3310), 560×445×220 mm (3600)
Disc Adjustment6-position gap setting
Disc TypesType I (standard, moisture analysis), Type II (fine, PSI testing), Type III (coarse, high-moisture oats/barley)
Optional Accessory3170 Motorized Feeder with rubber impeller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginImported (Sweden)
ModelRVA-TecMaster
Viscosity Range40–16,000 cP at 80 rpm
Sample Mass2–3 g
Measurement Time3 min (stirring value), 13 min (paste viscosity profile)
ComplianceGB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997)
SoftwareThermocline for Windows (TCW3), supports method upload and offline operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginImported
Manufacturer TypeAuthorized Distributor
ModeldoughLAB
Price RangeUSD 68,000 – 109,000
Torque Measurement Range0–25 N·m
Rotational Speed Range0 or 10–200 rpm
Temperature Control Range10–80 °C (standard), with ±0.2 °C stability at 30 °C
Water Dispensing Range1–300 mL
Sample Bowl Options50 g or 300 g
Dimensions (H×W×D)970 × 490 × 370 mm
Weight91 kg (with bowl), 70 kg (without bowl)
Ambient Operating Conditions5–40 °C, <80% RH at 31 °C
Data InterfaceRS-232 to USB converter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginUnited Kingdom
ModelSpectrum Two N
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform (Interferometric)
Wavelength Range680–4800 nm
Data Sampling Interval1/4 resolution or user-defined
Sample IntroductionDirect sampling
SoftwareSpectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelDA7430M
Instrument TypeOnline
PrincipleGrating Scanning NIR Spectrometer
Wavelength Range950–1650 nm
Scan Speed30 subspectra/second
Sampling IntervalUser-Configurable
Measurement ModeDiffuse Reflectance / Transflectance
Chemometrics SoftwareUnscrambler X, Percal
Ingress Protection RatingIP67
Optical Spot Diameter>10 cm
Light SourceLong-Life Xenon Lamp
Mounting CompatibilityChutes, Screw Conveyors, Belt Conveyors, Mixers, Scrapers
Communication ProtocolsOPC UA, Ethernet, Modbus TCP/IP, 4–20 mA Analog Output, Profibus
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelIM 9500plus
Instrument TypeLaboratory NIR Spectrometer
Application DomainCereal & Oilseed Analysis
PrincipleGrating Scanning Transmission NIR
Wavelength Range570–1100 nm
Scan Speed10 scans/min
Data Acquisition Interval6 s/scan
Measurement ModeTransmission
Chemometrics SoftwareUnscrambler X
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginImported
Manufacturer TypeAuthorized Distributor
ModelRVA4800
Voltage230/115 VAC, 5 A, 50/60 Hz
Dimensions (H×W×D)382 × 306 × 345 mm
Net Weight19 kg
Temperature Range0–140 °C
Heating/Cooling RateUp to 14 °C/min (adjustable)
Cooling RequirementTap water or recirculating chiller (1 L/min, 100–250 kPa)
Speed Range0, 20–2000 rpm (software-controlled)
Viscosity Range20–50,000 cP (at 80 rpm)
Viscosity Accuracy±2% at 5000 cP (calibrated against S2000 standard oil)
ComplianceISO 9000 / ISO/IEC 17025, GB/T 22427.7–2023, ICC, AACC, FDA 21 CFR Part 11 (ER/ES), GLP/GMP-ready audit trail in TCW3 software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginNetherlands
ModelLactoScope FT-B
Automation LevelSemi-Automatic
Analysis Speed60–80 samples/hour
Detection RangeFat: 0–40%
Protein0–15%
Lactose0–15%
Total Solids0–45%
Repeatability≤0.25% CV
Accuracy<1% CV
Operating SystemWindows-based GUI with localized Chinese interface
Calibration KitsPre-validated modules for raw milk, cream (up to 40% fat), whey, flavored milk, and yogurt
Data StorageSQL database architecture with backup/recovery support and external storage compatibility
Optical SystemDynascan™ interferometer-based FTIR with OpticsGuard™ desiccation and molecular sieve protection
ComplianceISO 9622 / IDF 141, AOAC 972.16, ICAR-certified
Sample Volume10 mL
Sample Temperature Range4–42 °C
Dimensions (W×D×H)49 × 70 × 49 cm
Weight86 kg
Power Supply100–120 V, 60 Hz or 220–240 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelGM2000
Gluten Washing Time5 min
Mixer Speed120 ± 5 rpm
Dough Mixing Time20 s
ComplianceAACC 38-12.02, ICC 155/158/137/1, ISO 21415-2 & -4, GB/T 5506.2 & 5506.4, IRAM 15864, CCAT Method 13
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLactoScope 300™ FT-IR
Detection ScopeRaw milk (cow, goat, sheep, camel), cream, whey, pasteurized milk, formulated milk, dairy beverages
Automation LevelSemi-automatic
Throughput60–80 samples/hour
Repeatability≤1.2% CV
Accuracy≤0.5% CV
Operating SystemWindows 10
Software InterfaceFully localized Chinese GUI with stepwise workflow navigation
Calibration ModulesPre-configured, ready-to-use calibration packs for raw milk, cream, whey, pasteurized milk, goat milk, sheep milk
Data StorageSQL-based database architecture with backup/restore capability and external storage support
Protein Range0–15% w/w
Measurement PrincipleFourier Transform Infrared Spectroscopy (FT-IR) with patented Dynascan™ interferometer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFT 9700
Instrument TypeLaboratory
Application DomainGeneral-purpose (Academic & Research)
Operating PrincipleFourier Transform (FT)
Wavelength Range700–2500 nm (14,300–4000 cm⁻¹)
Scan Speed<1 minute per spectrum
Data Sampling IntervalAdjustable
Sample Measurement ModesDiffuse Reflectance and Transflectance
Chemometrics SoftwarePerCal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginImported (Sweden)
ModelAM 5200
Heating MethodRadiofrequency (150 MHz)
Measurement PrincipleRF Dielectric Constant
Sample Volume700 mL
Analysis Time~10 s
Display5.7-inch color resistive touchscreen
CommunicationUSB port
Operating Temperature Range0–40 °C
Power Supply115/230 V, 50/60 Hz
Dimensions (W×D×H)415 × 424 × 353 mm
Net Weight18.3 kg
Measured ParametersMoisture content, bulk density, temperature
Sample TypesCereals, oilseeds, pulses (soybeans, lentils), dry beans, seeds, and other agricultural commodities
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginUSA
ModelDA 7350
Instrument TypeOnline
Wavelength Range950–1650 nm
Scan Speed>30 sub-spectra per second
Data Sampling IntervalUser-Configurable
Measurement ModesNear-Infrared Reflectance & Digital Color Imaging
Chemometrics SoftwarePerCAL
ComplianceDesigned for GLP/GMP environments
Communication ProtocolsOPC UA, PROFINET, Modbus TCP, Fieldbus
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelIM9520
Instrument TypeBenchtop Laboratory NIR Spectrometer
Application DomainCereal Grains & Milled Flour
Optical PrincipleGrating Scanning Transmission NIR
Wavelength Range570–1100 nm
Scan Speed10 scans/minute
Data Acquisition Interval6 seconds per measurement
Sample ModeTransmission
Chemometrics SoftwareUnscrambler®
Calibration FrameworkNIST-traceable wavelength calibration
ComplianceASTM D6341 (NIR for cereal analysis), ISO 12099:2017 (Animal feeding stuffs — General guidelines for the determination of chemical constituents by NIR spectroscopy), GLP-compliant data audit trail support via NetPlus™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelPaddyCheck™ PC 6800
ComplianceAACCI Method No. 61-10.01
PowerRechargeable battery (3 h analysis / 8 h standby)
DimensionsCompact, portable design
Sensor SuitePolarized light sensor, visible-light RGB sensor, precision force sensor (17 N max load)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginSweden
ModelLM3100
Grinding PrincipleHigh-Speed Hammer Mill with Pneumatic Feed & Cyclonic Separation
Maximum Batch Capacity≤300 g
Feed Size40–80 mesh
Output Particle Size≥0.5 mm (adjustable via stainless-steel sieve plates: 0.5–2.0 mm standard options)
Rotor Speed16,800 rpm
Grinding Time30–50 s for 300 g sample
Noise Level≤75 dB(A) with acoustic enclosure
Power Supply110–440 V, single- or three-phase, 50/60 Hz, 1.1 kW
Dimensions (LM3100)560 × 510 × 630 mm
ComplianceDesigned for GLP-compliant grain and feed analysis workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginNetherlands
ModelLactoScope FT-A
Automation LevelSemi-automatic
Analysis Speed100–120 samples/hour
Measurement RangeFat: 0–55%
Protein0–25% (including 0–15% for protein-specific quantification)
Lactose0–22%
Total Solids0–60%
Repeatability≤ 0.25% CV
Accuracy< 1% CV
Operating SystemWindows-based
Interface LanguageEnglish (localized UI available)
Calibration KitsPre-validated, ready-to-use modules for raw milk, cream, whey, flavored milk, and yogurt
Data StorageSQL database architecture with backup, restore, and external storage support
Optical TechnologyMid-infrared (MIR) Fourier Transform Infrared Spectroscopy
Measurement Time30–45 seconds per sample
InterferometerPatented Dynascan™ technology
Environmental ProtectionOpticsGuard™ desiccation system with molecular sieve
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerten
OriginUSA
ModelLactoScope™ FT-B
ApplicationLab & Online Alcoholic Beverage Analysis
Measurement Time45 s per sample
AnalytesEthanol, Total Acidity, Total Ester, Ethyl Hexanoate, Ethyl Acetate, Ethyl Lactate, Acetaldehyde, Methanol, Propanol, sec-Butanol, Acetal, Isobutanol, Butanol, Ethyl Butyrate, Isoamyl Alcohol
ComplianceDesigned for ISO 21563, AOAC Official Methods, and USP <1210> spectroscopic validation frameworks
SoftwarePerten WinISI III with GLP-compliant audit trail, 21 CFR Part 11 user authentication & electronic signature support
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0