| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Models | RC-6D, RC-8D, RC-806 |
| Pricing | Upon Request |
| Key | Stirring Speed Range: 20–250 rpm |
| Key | Speed Accuracy: ±2 rpm (RC-6D/8D), ±4% stability (RC-806) |
| Key | Temperature Control Range: 5.0–45.0 °C |
| Key | Temp Accuracy: ±0.3 °C |
| Key | Timer Range: 1–999 min (9-point programmable) or up to 24 h 59 min (RC-806, 12-point sampling) |
| Key | Basket Wobble: ≤±1 mm |
| Key | Paddle Wobble: ≤±0.5 mm |
| Key | Shaft-Cup Coaxiality: ≤2.0 mm (RC-806) |
| Key | Data Storage: Internal SD card with GLP-compliant audit trail |
| Key | Compliance: USP <711>, ChP 2020 Edition, ASTM D8141-21, ISO 16862:2022 |
| Brand | HJ |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | RC-1 / RC-3 / RC-6 / RC-8 |
| Drive Mechanism | Rotating Basket (USP Apparatus 1) & Paddle (USP Apparatus 2) |
| Temperature Control Range | Ambient to 45.0 °C |
| Temp. Accuracy | ±0.3 °C |
| Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Timer Range | 5–999 min (RC-1: up to 900 min |
| RC-3/6/8 | up to 999 min) |
| Timer Accuracy | ±0.1% |
| Basket Wobble | ±1 mm |
| Paddle Shaft Runout | ±0.5 mm |
| Shaft Eccentricity | ±2.0 mm |
| Heating Power | 500 W (RC-1/RC-3), 1000 W (RC-6/RC-8) |
| Total Power Consumption | 600 W (RC-1/RC-3), 1200 W (RC-6/RC-8) |
| Continuous Operation | >24 h |
| Power Supply | 220 V / 50 Hz |
| Construction Material | Electropolished SUS316L Stainless Steel (Baskets, Paddles, Shafts, Vessel Holders) |
| Fluid Circulation | Magnetic-drive or Micro-peristaltic Pump System |
| Compliance | Chinese Pharmacopoeia (ChP) 2015 Edition |
| Data Display | Dual-line LCD showing setpoints and real-time values |
| Automation Level | Fully Automated Parameter Control (Temp, Speed, Time), Self-Diagnosis, Fault Alerting, Audible Timing Alerts |
| Brand | HJ (Hujing Purification) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | TP-6 |
| Price | Upon Request |
| Diffusion Cell Count | 6 |
| Receiver Compartment Volume | 15 mL (vertical configuration, standard) |
| Temperature Control Range | 30–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Stirring Speed Range | 100–800 rpm |
| Speed Accuracy | ±5% |
| Power Supply | 220 V ±10%, 50 Hz, 360 W |
| Brand | HJ (Hujing Purification) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WD-2A |
| Pricing | Upon Request |
| Temperature Range | Ambient to 80 °C ±1 °C |
| Humidity Range | 10–100% RH ±4% |
| Dual Humidity Monitoring | Two Honeywell (USA) RH Sensors for Simultaneous 75% RH and 92.5% RH Measurement |
| Illuminance Range | 0–7,000 lx (with Three Adjustable Slit Lamps) |
| Chamber Dimensions | 51 × 40 × 38 cm (Stainless Steel Interior, Two-Tier Configuration) |
| Operating Noise Level | <50 dB(A) |
| Brand | HJ |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Wit-V4.0 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 6000 mbar |
| Minimum Inlet Pressure | 200 mbar |
| Dimensions (W×D×H) | 40 × 30 × 25 cm |
| Forward Flow Range | 0.1–200 mL/min |
| Water Intrusion Flow Range | 0.05–50 mL/min |
| Bubble Point Range | 700–6000 mbar |
| Accuracy | ±3% or ±5‰ F.S. (whichever is greater) |
| Sensitivity | Forward Flow: 0.1 mL/min |
| Water Intrusion | 0.01 mL/min |
| Bubble Point | 50 mbar |
| Repeatability Error | ≤3% |
| Test Duration (typical) | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Display | 7-inch color touchscreen (256-color), Windows CE 6.0 OS |
| Controller | ARM11 embedded processor |
| Data Storage | 32 GB internal flash memory (≥1 million test records) |
| Printing | Integrated thermal printer for test conditions, results, and real-time curves |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Compliance | Meets requirements of Chinese Pharmacopoeia (2020 Edition), supports 21 CFR Part 11-compliant electronic signatures, audit trail, and role-based user access control |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YB-2 / YB-3 |
| Power Consumption | 20 W (YB-2) / 22 W (YB-3) |
| Light Source | 20 W A-grade pharmaceutical-grade tri-phosphor fluorescent lamp with electronic ballast |
| Illuminance Range | 1000–6000 lx |
| Timing Range | 1–99 s (adjustable) |
| Dimensions (YB-2) | 703 mm × 175 mm × 513 mm |
| Dimensions (YB-3) | 703 mm × 345 mm × 513 mm |
| Weight (YB-3) | ~25 kg |
| Compliance | Designed for USP <790>, EP 2.9.20, and ChP Appendix XIX F (Clarity of Solutions) |
| Control System | Integrated microcontroller-based digital control |
| Illuminance Calibration | User-accessible calibration via external standard lux meter |
| Detection Surface | Extended white diffusing plate (dual-side illumination for YB-3) |
| Visual Ergonomics | Flicker-free optical path, adjustable illuminance, integrated audio-visual alarm |
| Display | Digital lux readout with real-time stability indication |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YD-1 / YD-2 / YD-35 |
| Test Range (YD-1) | 0–20 kg (0–196.2 N) |
| Test Range (YD-2) | 2–200 N (0.2–20 kg) |
| Test Range (YD-35) | 1–350 N |
| Resolution | 0.1 N (YD-2/YD-35), 0.01 kg |
| Accuracy | ±0.03 kg or ±0.5% FS (full scale), whichever is greater |
| Tablet Diameter Range | 2.0–40.0 mm (YD-2), 2.0–30.0 mm (YD-35) |
| Diameter Accuracy | ±0.01 mm (YD-35) |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 10 W (YD-1), 40 W (YD-2), not specified (YD-35) |
| Dimensions (YD-2) | 400 × 240 × 140 mm (L×W×H) |
| Display | LED (YD-1), LCD with bilingual interface (YD-2/YD-35) |
| Measurement Modes | Manual single-tablet, automatic batch testing (up to 100 tablets for YD-2 |
| Data Output | Auto-lock, auto-reset, statistical analysis, time-stamped reporting, calibration traceability, unit conversion (N/kg/Sc, mm/inch) |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | MFS-3-PRO |
| Vacuum Pump Type | Integrated High-Vacuum Silent Diaphragm Pump |
| Filtration Capacity | Up to 3 Independent Channels |
| Data Storage | 6400 Sets of Sampling Records |
| Sterilization Compatibility | 121 °C Autoclavable (Stainless Steel Filter Cups & Holders) |
| Display | HD Touchscreen LCD |
| Language Interface | English & Chinese |
| Compliance | GB 8538–2016, GB/T 5750.12–2006, GB/T 18204.5–2013, GB/T 19298–2014, ChP 2020 Microbial Limits Test |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-06S |
| Measurement Range | 1–500 µm |
| Channel Options | ≥5, ≥8, ≥10, ≥12, ≥25, ≥100 µm (customizable) |
| Pharmacopoeia-Compliant Channels | ≥10 µm, ≥25 µm |
| Sample Volume Range | 0.1–1000 mL |
| Minimum Sample Volume | ≥0.1 mL |
| Volume Accuracy | < ±0.5% |
| Counting Range | 0–9,999,999 particles |
| Particle Concentration Range | 0–10,000 particles/mL |
| RSD | ≤2% (for standard particles ≥1000 particles/mL) |
| Sampling Time | <8 s for 5 mL |
| Time Accuracy | ±5% of set value |
| Channel Resolution | ≥95% (≥10 µm channel) |
| Stirring Speed | 0–2000 rpm, continuously adjustable |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤90 W |
| Dimensions | 360 × 330 × 415 mm |
| Brand | Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-10 |
| Pricing | Available Upon Request |
| Material | Medical-Grade Silicone |
| Customization | Fully Configurable to ISO/USP/Ph. Eur.-Compliant Inhaler Interfaces |
| Compliance | Designed in Accordance with Chinese Pharmacopoeia (2020 Edition), USP <601>, and ISO 27427 |
| Brand | Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-CER05 |
| Price | Upon Request |
| Cabinet Structure | Vertical Upright |
| Internal Dimensions (D×W×H) | 660 × 500 × 550 mm |
| External Dimensions (D×W×H) | ~1260 × 600 × 800 mm |
| Temperature Range (No Load) | 0–10 °C |
| Temperature Uniformity (No Load) | ≤ ±2 °C |
| Temperature Stability (No Load) | ±0.5 °C |
| Heating Rate (No Load, Average) | 1–4 °C/min |
| Total Power Consumption | ~1.8 kW |
| Power Supply | AC 220 V / 50 Hz |
| Regulatory Reference | Chinese Pharmacopoeia (2020 Edition), Chapter <0901> Aerosols, Sprays and Inhalers |
| Brand | Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-Inhalation |
| Pricing | Available Upon Request |
| Cascade Impactor Compatibility | Next Generation Impactor (NGI) & Andersen Cascade Impactor (ACI) |
| Test Chamber Volumes | 1 L (for nasal aerosols), 2 L (for nasal sprays), 5 L (for high-velocity nasal sprays) |
| Regulatory Alignment | FDA Guidance for Industry (2002, 2003), Ph. Eur. 10.5 Monograph 0676 |
| Brand | Huironghe |
|---|---|
| Model | HRH-WS300 |
| Temperature Range | 15–40 °C |
| Temp. Accuracy | ±2 °C (unloaded) |
| Humidity Range | 15–90 % RH |
| Humidity Accuracy | ±5 % RH (unloaded) |
| Internal Chamber Dimensions | 950 × 380 × 520 mm (W×D×H, min.) |
| Overall Dimensions | 1450 × 800 × 1100 mm (W×D×H, max.) |
| Power Consumption | ~5.5 kW |
| Voltage | 220 V AC, 16 A |
| Electrostatic Minimization System | Standard |
| Illumination | Integrated LED Lighting |
| Control Interface | Touchscreen |
| Timed Start/Stop Function | Standard |
| Compliance | USP <601>, Ph. Eur. 2.9.18, ISO 15378:2017 (environmental control clauses) |
| Key | Brand: Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-XP2020 |
| Dimensions (W×D×H) | 77 × 20 × 19 cm |
| Weight | 7 kg |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 60 W |
| Maximum Tilt Angle | ±20° |
| Angular Velocity | up to 20°/s |
| Positional Accuracy | ±1° |
| Maximum Operational Cycles | 30,000 |
| Compliance | Designed for NGI-compatible plate handling in USP <601> and ISO 27427-compliant aerodynamic particle size distribution (APSD) workflows |
| Brand | Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-ZJQ160 |
| Pricing | Upon Request |
| Compliance | USP <601>, Ph. Eur. 2.9.18, ChP 2020 Vol. IV <0951> |
| Stage Configuration | 7-Stage Andersen-type with Micro-Orifice Collector (MOC) |
| Flow Rates Supported | 15–100 L/min |
| Nozzle Tolerances | ±0.01–±0.05 mm |
| MOC Effective Cut-Point | ≤0.07 µm at 100 L/min |
| Brand | HRH |
|---|---|
| Model | HRH-ZY200 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Dimensions (W×D×H) | 415 × 615 × 285 mm |
| Weight | 35 kg |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 440 W |
| Oscillation Frequency Range | 20–200 cycles/min |
| Rolling Speed Range | 10–20 rpm |
| Maximum Continuous Operation Time | 500 h |
| Operating Modes | Oscillation Only, Rolling Only, Combined Oscillation + Rolling |
| Touchscreen Interface | Yes |
| Compatibility | Pressurized Metered-Dose Inhaler (pMDI) Sampling Tubes, Dry Powder Inhaler (DPI) Sampling Tubes, DPI Test Tubes with Pressure Port |
| Brand | Huiron |
|---|---|
| Model | HRH-BRM-2100 |
| Origin | Beijing, China |
| Tidal Volume Range | 0–1000 mL |
| Accuracy | ±5% of full scale or ±1 mL (whichever is greater) |
| Power Supply | 220 V, 50 Hz |
| Dimensions | 70 × 35 × 62 cm |
| Weight | 35 kg |
| Compliance | USP <601>, Ph. Eur. 2.9.43, ChP 2020 Vol. IV <0951> |
| Predefined Breathing Profiles | Adult / Pediatric / Infant / Neonatal |
| Customizable Parameters | Tidal Volume, Breathing Frequency, I:E Ratio, Flow Profile Shape, Cycle Count |
| Real-time Output | Flow Rate Curve, Tidal Volume Curve, Respiratory Parameter Summary |
| Brand | Huironhe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRH-MDI10 |
| Power Supply | 220 V, 50 Hz, 10 A |
| Dimensions (Basic) | 220 mm × 230 mm × 320 mm |
| Dimensions (Shaking Version) | 415 mm × 300 mm × 525 mm |
| Weight (Basic) | ~10 kg |
| Weight (Shaking Version) | ~20 kg |
| Max Actuation Frequency | 2 actuations/s |
| Simultaneous Actuations per Cycle | 2 units |
| Carousel Capacity | 10 MDI canisters |
| Shaking Frequency (optional) | 5–600 rpm |
| Shaking Amplitude (optional) | 40 mm |
| Key | Brand: Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Autotab-200 |
| Max Compression Force | 40 kN |
| Max Tablet Diameter | Φ16 mm (IPT/TSM-B) / Φ23 mm (IPT/TSM-D) |
| Fill Depth | ≈18 mm |
| Tooling Standard | IPT/TSM-B or D |
| Cycle Time | 12–20 sec/tablet |
| Motor Power | 0.8 kW |
| Voltage | 100/110 V or 200/220 V |
| Weight | 180 kg |
| Dimensions (W×D×H) | 400 × 500 × 1540 mm |
| Hopper Capacity | 100 mL |
| Compliance | IPT, TSM, EU standard tooling compatible |
| Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Autotab-200TR |
| Maximum Compression Force | 40 kN |
| Max Tablet Diameter | Φ16 mm (IPT/TSM-B) / Φ23 mm (IPT/TSM-D) |
| Fill Depth | ~18 mm |
| Tooling Standard | IPT/TSM-B or D |
| Cycle Time | 30–60 sec per tablet |
| Motor Power | 0.8 kW |
| Voltage | 100/110 V or 200/220 V |
| Weight | 240 kg |
| Dimensions (W×D×H) | 600 × 500 × 1540 mm |
| Hopper Capacity | 70 mL × 3 |
| Safety Interlock | Three-side mechanically and programmatically interlocked doors |
| Data Export | USB interface with proprietary PC software for compression force, ejection force, and cycle log export |
| [Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Autotab-200W |
| Max Compression Force | 40 kN |
| Max Tablet Diameter | Φ16 mm (IPT/TSM-B) or Φ23 mm (IPT/TSM-D) |
| Fill Depth | ~18 mm |
| Tooling Standard | IPT/TSM-B or D |
| Cycle Time | 20 sec/tablet |
| Motor Power | 0.8 kW |
| Voltage | 100/110 V or 200/220 V |
| Weight | 220 kg |
| Dimensions (W×D×H) | 500 × 500 × 1540 mm |
| Hopper Capacity | 2 × 70 mL |
| Compliance | IPT, TSM, EU tooling compatible |
| Data Export | USB interface with proprietary software] |
| Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | AUTOTAB-R2000 / AUTOTAB-R2000W |
| Max Compression Force | Pre-compression 12 kN / Main compression 40 kN |
| Max Tablet Diameter | 20 mm (R2000), 16 mm (R2000W) |
| Max Fill Depth | 18 mm (single-layer), 8 mm (second-layer for R2000W) |
| Max Output | 12,600–16,200 tablets/hour |
| Turret Speed | up to 30 rpm |
| Punch Standard | TSM/IPT (EU-B: 7 stations, EU-D: 9 stations) |
| Control Interface | 10-inch industrial touchscreen HMI |
| Weight | 580–600 kg |
| Dimensions (W×D×H) | 620 × 870 × 1930 mm |
| Power Supply | 3-phase 380 V AC |
| Motor Rating | 2.2 kW |
| Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Autotab-R2000W |
| Maximum Compression Force | 12 kN (pre-compression) / 40 kN (main compression) |
| Max. Tablet Diameter | 20 mm (Layer 1), 16 mm (Layer 2) |
| Max. Fill Depth | 18 mm (Layer 1), 8 mm (Layer 2) |
| Max. Production Speed | 16,200 tablets/hour |
| Turret Diameter | 200 mm |
| Punch Standard | TSM/IPT (EU-D & EU-B) |
| Control Interface | 10-inch touchscreen HMI |
| Weight | 600 kg |
| Dimensions (W×D×H) | 620 × 870 × 1930 mm |
| Motor Power | 2.2 kW |
| Voltage | 3-phase 380 V |
| Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | Handtab-100 / Handtab-100R |
| Maximum Compression Force | 30 kN (3 tf) |
| Max Tablet Diameter | 23 mm (Handtab-100), 16 mm (Handtab-100R) |
| Max Fill Depth | 18 mm |
| Punch Type | TSM IPT-B/D Standard |
| Machine Weight | 17 kg (main unit) + 3.5 kg (hydraulic pump) |
| Dimensions (W×D×H) | 200 × 200 × 680 mm |
| Pressure Indication | Analog Hydraulic Pressure Gauge |
| Compliance | Designed for GLP-aligned lab environments, compatible with USP <1059>, ISO 8536-1, and ASTM D6117 (pharmaceutical tablet mechanical testing) |
| Brand | Ichihashi Seiki |
|---|---|
| Origin | Japan |
| Model | HANDTAB-100T15 |
| Max Compression Force | 150 kN (15 tf) |
| Max Tablet Diameter | 50 mm |
| Max Fill Depth | 46 mm |
| Upper/Lower Punch Stroke | Adjustable |
| Pressure Display | Analog Gauge (optional digital pressure sensor available) |
| Construction | Stainless Steel with Optional Electroless Nickel Plating |
| Dimensions (H×W×D) | 620 × 200 × 200 mm |
| Weight | 35.5 kg (main unit), 10 kg (hydraulic pump) |
| Punch Compatibility | TSM Standard (IPT-B/D), interchangeable |
| Safety Design | Dual-hand operation interlock, pressure relief valve, mechanical stop limit |
| Brand | Huironghe |
|---|---|
| Model | HRH-20 |
| Origin | Beijing, China |
| Type | In Vitro–In Vivo Correlation (IVIVC) Simulation System for Orally Inhaled Products (OIPs) |
| Airflow Range | 0–100 L/min |
| Peak Inspiratory Flow Rate Simulation | 0–100 L/min |
| Flow Acceleration Rate | 0–15 L/s² |
| Respiratory Waveform Customization | Yes |
| Compliance Reference | Good Cascade Impactor Practices (GCIP), AIM & EDA Guidelines for Orally Inhaled Products (2013) |
| Intended Use | IVIVC development, aerodynamic particle size distribution (APSD) testing, delivered dose uniformity (DDU) assessment |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | INNOTEG Syringe Filters |
| Pricing | Available Upon Request |
| Membrane Materials | Nylon 66, Hydrophobic PTFE, Hydrophilic PTFE, Polyethersulfone (PES), Polyvinylidene Fluoride (PVDF), Mixed Cellulose Ester (MCE) |
| Pore Sizes | 0.22 µm and 0.45 µm |
| Diameters | 13 mm and 25 mm |
| Connector Type | Luer Lock / Luer Slip Compatible |
| Packaging | 100 units per canister |
| Brand | Innuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPT-C2 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | V4.0 |
| Price | USD 5,300 (FOB Beijing) |
| Power Supply | 100–240 V AC, 50/60 Hz, 110 W |
| Operating Pressure Range | 500–6900 mbar |
| Low Inlet Pressure Threshold | 3000 mbar |
| Dimensions (W × D × H₁ × H₂) | 400 × 380 × 100 × 235 mm |
| Test Accuracy | Net Volume ±4% |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Test Duration | Water Intrusion Test = preset time + 5 min ±2 min |
| Data Storage | 500 test records (expandable to 1000), including full pressure/flow curves |
| Display | 5.7" monochrome TFT LCD with backlight |
| Communication Interface | RS232 serial port |
| Language Support | English, Chinese |
| Compliance | Designed to support ASTM F838-22, ISO 13408-2, USP <1207>, and EU Annex 1 requirements for filter validation and integrity testing |
| [Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Integtest™ v4.0 |
| Price | USD 5,300 (FOB Beijing)] |