| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BP-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Print Output | Bilingual (English/Chinese), including test parameters, results, and pressure decay curves |
| Environmental Operating Conditions | 0–50 °C, 10–80% RH |
| Test Duration | Bubble point: 2 ± 2 min |
| Diffusion flow | 7 ± 2 min |
| Water intrusion | 7 ± 2 min |
| System leak check | 3 ± 1 min |
| Communication Interface | RS232/USB for PC connectivity and remote supervision via proprietary software |
| Compliance Support | Fully compatible with FDA 21 CFR Part 11 audit trail requirements, EU Annex 1, USP <1207>, ISO 13408-2, and GMP Annex 15 integrity testing protocols |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BQS |
| Price Range | USD 1,400 – 2,800 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 9000 mbar (145 psi) |
| Min Inlet Pressure | 4000 mbar (58 psi) |
| Dimensions | 400 × 380 × 335 mm (W × D × H) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Accuracy | Net Volume Test ±4% |
| Environmental Conditions | 15–35 °C |
| Test Duration | Net Volume Test 5±2 min |
| Water Intrusion Test | Set Time + 5±2 min |
| Display | 5.7″ backlit monochrome LCD |
| Data Interface | RS232 serial port |
| Language Options | English / Chinese |
| Storage Capacity | 500 test records (incl. curves) |
| Print Output | Dot-matrix printer (Chinese/English), full parameter + result + curve |
| Sample Compatibility | Disc membranes Φ25–Φ300 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar (sensor customizable) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal, ≥1 million test records |
| Print Output | Thermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 Series |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Test Duration (Diffusion Flow / Water Intrusion) | 7 ± 2 min |
| System Leak Test Time | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Data Storage | 32 GB (≥1 million records) |
| Interface | RS232/USB/Ethernet for PC connectivity |
| Compliance Support | FDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready |
| Language Options | English & Chinese |
| Dimensions | 500 × 200 × 180 mm (L×W×H) |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-19+ |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤100 W |
| Max Operating Pressure | 9999 mbar |
| Min Inlet Pressure | 4000 mbar |
| Pressure Range for Testing | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Test Accuracy | ±4% |
| Test Duration (Bubble Point) | 15 ± 2 min |
| Test Duration (Enhanced Bubble Point) | 20 ± 2 min |
| Test Duration (Diffusion Flow) | 10 ± 2 min |
| Display | 5.7" monochrome TFT LCD |
| Interface | RS232 serial port |
| Data Storage | 500 test records (configurable extension via PC connection) |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Dimensions (W × D × H1 × H2) | 400 × 380 × 100 × 235 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BQS-40 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Maximum Operating Pressure | 7999 mbar |
| Inlet Gas Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Compliance | CE certified, FDA 21 CFR Part 11 compliant architecture, GMP-aligned audit trail |
| Enclosure Rating | IP54 |
| Supported Test Methods | Bubble Point, Diffusion Flow, Pressure Hold (Decay), Water Intrusion |
| Brand | All Precision Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | S-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal flash memory (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet for PC connectivity and remote supervision |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11 (audit trail ready), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | D1200 PRO |
| Instrument Type | Online Sampling Dissolution System |
| Vessels | 12 |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Model | D1200 |
| Instrument Type | Online Dissolution System |
| Vessel Capacity | 12 vessels |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter <0931> Dissolution and Release Testing |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | D1200 PRO Immersion Cell |
| Instrument Type | Online Dissolution Sampling System |
| Dissolution Vessels | 12-position |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | R3000 PRO |
| Instrument Type | Offline Dissolution System |
| Vessel Configuration | 7-position × 6-row cylinder rack |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | R7000 PRO |
| Instrument Type | Offline Sampling System |
| Vessel Configuration | 7-position × 6-row dissolution cups |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T1200 PRO |
| Pricing | Available Upon Request |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T1200 |
| Pricing | Available Upon Request |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | T2400 PRO |
| Pricing | Available Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-39S |
| Measurement Principle | Refractive Index (RI) |
| Range | 0.0–50.0% w/w H₂O₂ |
| Resolution | 0.002% |
| Accuracy | ±0.6% |
| ATC Range | 10–40°C |
| IP Rating | IP65 |
| Weight | 100 g |
| Dimensions | 5.5 × 3.1 × 10.9 cm |
| Sample Volume | ~0.5 mL |
| Measurement Time | ~3 seconds |
| Zeroing Method | Distilled Water Calibration |
| E.L.I. (External Light Interference) Technology | Yes |
| Portability | Handheld, Hook-Mounted Design |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME2 |
| Price | USD 198,000 (FOB) |
| Number of dissolution vessels | 7 |
|---|---|
| Rotational speed range | 25–250 rpm |
| Speed resolution | 1 rpm |
| Speed accuracy | ±2% |
| Water bath temperature range | Ambient +5°C to 60°C |
| Temperature control accuracy | ±0.1°C |
| Maximum cumulative timing | 99 h 59 min |
| Number of programmable sampling intervals | 10 |
| Maximum interval duration | 9 h 59 min |
| Auto power-on/off timer range | 99 h 59 min |
| Power consumption | 1300 W |
| Input voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 670 × 470 × 420 mm |
| Net weight | ~42 kg |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Housing | TO-39 metal can |
| Spectral Range | 2–16 µm |
| Emissivity | >0.95 (blackbody-like) |
| Modulation Speed | Up to 100 Hz (electrical, chopper-free) |
| Power Consumption | <150 mW (typ.) |
| Lifetime | >50,000 h (at rated operating conditions) |
| MEMS Qualification | IEC 60749-21 / IEC 61340-5-1 / IEC 60068-2 series compliant |
| Optional Windows | Sapphire, CaF₂, BaF₂, Ge |
| Mounting | Standard TO-39 footprint with solderable leads |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS1-19 |
| Price | USD 2,500 (FOB Beijing) |
| Brand | Beiguang Jingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (PRC-Made) |
| Model | BQ19 |
| Price | USD 3,500 (approx.) |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar |
| Min Inlet Pressure | 3000 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±75 mbar |
| Operating Temperature | +5 °C to +35 °C |
| Relative Humidity | 10–80 % RH |
| Test Duration (Rapid Bubble Point) | 9 ±2 min |
| Test Duration (Bubble Point Scan) | 20 ±2 min |
| Data Storage Capacity | 20 test records |
| Display | 73 × 39 mm monochrome LCD |
| Language Support | English, Chinese |
| Compliance | Designed for ASTM F838-22, ISO 13408-2, USP <1207>, EU GMP Annex 1, and FDA 21 CFR Part 11–ready data logging architecture |
| Brand | Beiguang Jingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-9 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Test Pressure Range | 500–6900 mbar |
| Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Ambient Operating Conditions | 0–50 °C, 10–80% RH |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Diffusion Flow Test | 7 ± 2 min |
| Water Intrusion Test | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Language Options | English & Chinese |
| Data Storage | 32 GB (≥1,000,000 records) |
| Printing | Integrated thermal printer (bilingual output of test parameters, results, and pressure curves) |
| Communication Interface | RS232/USB for PC connectivity and remote control via proprietary software |
| Compliance Support | Designed to support GLP/GMP workflows with user-level access control, audit trail-ready operation, and FDA 21 CFR Part 11–compatible data handling (when used with validated software configuration) |
| Key | Brand: Beijing Guangjing / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BQS19 |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Basic Bubble Point Test Duration | 2 ± 2 min |
| Diffusion Flow Test Duration | 7 ± 2 min |
| Water Intrusion Test Duration | 7 ± 2 min |
| System Leak Test Duration | 3 ± 1 min |
| Disc Membrane Compatibility | Φ25 mm to Φ300 mm |
| Cartridge Length Range | 2.5″ to 40″ |
| Cartridge Core Count | 1–9 cores |
| Capsule & Mini-Cartridge Support | Yes |
| Air Filter Testing Capability | Yes |
| Display | 5.7″ 32-bit touchscreen |
| Language Options | English / Chinese |
| Data Storage | 32 GB (≥1 million test records) |
| Interface | RS232 / USB / Ethernet (for PC connectivity and remote control) |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Dimensions (L×W×H) | 500 × 200 × 180 mm |
| Printing | Thermal printer with bilingual (EN/CN) output of test conditions, results, and real-time curves |
| Brand | Beijing North Guang Precision Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color TFT touchscreen, 256-color, bilingual (English/Chinese) interface |
| Storage Capacity | 32 GB (≥1 million test records) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Test Duration (typical) | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11 (audit trail enabled), ISO 13408-2, ASTM F838, USP <1207> |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | BF-II |
| Price | USD 740 (approx.) |
| Max Instantaneous Flow Rate | 300 L/min |
| Flow Measurement Range | 20–250 L/min |
| Vital Capacity (VC) Range | 0–10 L |
| Tidal Volume (VT) Range | 0.10–2.00 L |
| MVV Range | 0–200 L/min |
| FEV₁ Range | 0–5 L |
| Accuracy | ≤ ±5% FS |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Power Supply | AC 220 V or Rechargeable Internal Battery |
| Power Consumption | ≤6 W |
| Brand | Charles River |
|---|---|
| Origin | USA |
| Manufacturer | BioTek Instruments, Inc. |
| Type | Imported |
| Model | BioTek® ELx808IU |
| Pricing | Available upon Request |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Quotation | Upon Request |
| Temperature Range (Dark) | 0–70°C |
| Temperature Range (Illuminated) | 10–70°C |
| Humidity Range (Dark) | 30–95% RH |
| Humidity Range (Illuminated) | 40–95% RH |
| Temperature Uniformity | ±1.0°C (≤1050 L) / ±1.5°C (1050 L model) |
| Humidity Uniformity | ±5% RH |
| Temperature Fluctuation | ≤±0.5°C |
| Humidity Fluctuation | ≤±3% RH |
| Illuminance Control (ZYP models) | 0–10,000 lux (adjustable), ±500 lux tolerance |
| UV Spectrum (Optional) | 320–400 nm |
| UV Irradiance (Optional) | 0–2 W/m² |
| Internal Volume | 100–1050 L |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Compliance | ICH Q1A(R3), Q1B, USP <1151>, Chinese Pharmacopoeia (2020 Ed.), GMP Annex 11, ISO 9001 |
| Brand | Boante |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | Upon Request |
| Temperature Range (Dark) | 0–70°C |
| Temperature Range (Illuminated) | 10–70°C |
| Humidity Range (Dark) | 30–95% RH |
| Humidity Range (Illuminated) | 40–95% RH |
| Temperature Uniformity | ±1.0–±1.5°C |
| Humidity Uniformity | ±5% RH |
| Illuminance Control | 0–10,000 lux (LED, continuously adjustable) |
| Illuminance Accuracy | ±500 lux |
| UV Spectrum Option | 320–400 nm (optional) |
| UV Irradiance | 0–2 W/m² (optional) |
| Compliance | ICH Q1A(R3), Q1B, USP <1151>, Chinese Pharmacopoeia (2020 Ed.), GMP Annex 11, ISO 9001, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | BONAPACE |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | INCAP |
| Pricing | Available Upon Request |
| Brand | Boxun |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BXBY-** |
| Price Range | USD 14,000 – 21,000 |
| Temperature Range | 10–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity (at 25 °C) | ≤ ±1.5 °C |
| Temperature Fluctuation (at 25 °C) | ≤ ±0.5 °C |
| Humidity Range | 40–95 %RH |
| Humidity Resolution | 0.1 %RH |
| Humidity Fluctuation | ≤ ±3 %RH |
| Construction | Cold-rolled steel exterior with PVC-coated finish |
| Interior chamber | SUS304 stainless steel |
| Floor | Anti-slip aluminum tread plate with reinforced stainless steel substructure |
| Shelving | Adjustable SUS304 hooks-mounted racks |
| Control System | BRIGHT II adaptive PID controller with auto-compensation logic |
| Data Management | Onboard logging with U盘 export (immutable .csv/.pdf), event log (date/time/event/description), audit trail support |
| Security | Three-level password protection, fingerprint-enabled electronic door lock, mechanical anti-lock outer door |
| Environmental Monitoring | Dual-channel (T/RH) standard sensor suite |
| Refrigeration | Twin inverter-driven compressors (N+1 redundancy) |
| Humidification | External surface-evaporation system (N+1 redundancy), integrated water softener |
| Compliance | GB/T 10586–2006, ICH Q1A(R3), ChP 2020 Stability Guidance, USP <1151>, ISO 14644-1 Class 8 (optional cleanroom integration) |