| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MSC-1500GSP |
| Voltage | AC 380 V, 50 Hz |
| Temperature Range | 0–65 °C (unlit) / 10–50 °C (lit) |
| Humidity Range | 40–95 % RH |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | ±3 % RH |
| Illuminance Control | 0–6000 lx (digital sensor feedback) |
| Chamber Volume | 1500 L |
| Power Consumption | 7200 W |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MSC-1500SP |
| Temperature Range | 0–65 °C (unlit) / 10–50 °C (lit) |
| Humidity Range | 40–95 %RH |
| Illumination Range | 0–6000 lx |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | ±3 %RH |
| Power Supply | AC 380 V, 50 Hz |
| Nominal Volume | 1500 L |
| Internal Dimensions (W×D×H) | 1410×800×1500 mm |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | QGMC-250VS-II |
| Temperature Range | 0–65 °C |
| Temperature Uniformity | ±1.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 30–95 %RH (customizable to 20–98 %RH) |
| Humidity Deviation | ±3–5 %RH |
| Illuminance Range | 0–30,000 lx (vertical LED illumination, digitally adjustable) |
| Control Interface | 7-inch color touchscreen (dual-language: English/Chinese) |
| Programmability | 999 programs × 100 segments each |
| Data Logging | Timestamped U disk export (CSV/Excel), audit-trail compliant |
| Communication | RS485 Modbus interface |
| Safety | Dual independent temperature protection, triple fault-safety shutdown (overheat/overload/leakage), auto-recovery after power loss |
| Construction | 304 stainless steel interior, electrostatically sprayed exterior, silicone door gasket |
| Compliance | Designed per ICH Q1A(R3), USP <1151>, 2015 Chinese Pharmacopoeia Stability Guidance, GB/T 10586–2006 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | STA-Tri-250S-II |
| Price Range | USD 7,000 – 12,500 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | STA-Vert-150S-II |
| Price Range | USD 6,300 – 13,400 |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XGMC-150 |
| Temperature Control Range | 0–65°C |
| Temperature Uniformity | ±1.5°C |
| Temperature Fluctuation | ±0.5°C |
| Humidity Control Range | 30–95% RH (customizable to 20–98% RH) |
| Humidity Deviation | ±3–5% RH |
| Illuminance Range | 0–25,000 lx |
| Light Spectrum Configuration | UV (320–400 nm), Visible (400–760 nm), IR (760–1000 nm) |
| Light Distribution | Triple-side LED illumination |
| Internal Volume | 150 L |
| Internal Dimensions (W×D×H) | 500 × 400 × 750 mm |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2.2 kW |
| Compressor Configuration | Single or dual (II-type optional) |
| Standard Interfaces | RS485 (Modbus), 25 mm test port |
| Data Logging | USB-exportable CSV/Excel with timestamps, audit trail, alarm events |
| Compliance | Designed for ICH Q1–Q5, USP <1151>, EP 2.9.40, and Chinese Pharmacopoeia 2015 Edition stability testing requirements |
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XGMC-500S-II |
| Price Range | USD 7,000 – 10,500 |
| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK672 |
| Temperature Control Range (Dark) | 0–65°C |
| Temperature Control Range (Illuminated) | 10–50°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Humidity Range | 40–95% RH |
| Humidity Deviation | ±3% RH |
| Illuminance Range | 0–6000 lx (adjustable) |
| Illuminance Accuracy | ≤±500 lx |
| Timer Range per Segment | 1–99 h |
| Cooling System | Dual Independent Hermetic Compressors (Auto-Switching) |
| Controller | Programmable LCD Controller |
| Sensors | Pt100 Platinum Resistance Thermometer, Capacitive Humidity Sensor |
| Internal Volume | 250 L |
| Interior Dimensions (W×D×H) | 600×500×830 mm |
| Exterior Dimensions (W×D×H) | 740×890×1680 mm |
| Standard Shelves | 3 pcs |
| Integrated Thermal Printer | Standard |
| Safety Protections | Compressor Overheat, Fan Overheat, Overtemperature, High-Pressure Cut-off, Overload, Low-Water Detection |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 2600 W |
| Ambient Operating Temperature | RT+5 to 30°C |
| Lighting Method | Stepless Dimming |
| Built-in Top-Mount Illuminators | Standard |
| Light Meter | Included |
| Brand | ERWEKA |
|---|---|
| Origin | Germany |
| Model | ZT730 |
| Test Stations | 1 (ZT731) or 2 (ZT732) |
| Touchscreen | 7-inch capacitive LCD |
| Memory Capacity | 200 product/method profiles + ~4 GB for ≥1,000,000 test results |
| Stroke Speed | 30 ± 1 mm/min |
| Stroke Height | 55 ± 2 mm |
| Heating | Integrated flow-through heater with PT100 temperature sensor |
| Temperature Control Range | Compliant with USP <701> and Ph. Eur. 2.9.1 (typically 37.0 ± 0.5 °C) |
| AirBasket Types | Type A (6 tubes) or Type B (3 tubes + disc holder) |
| Power Supply | 230 VAC ±10%, 50–60 Hz / 115 VAC ±10%, 50–60 Hz |
| Max. Power Consumption | 1750 W |
| Interfaces | USB-A, USB-B, Ethernet (LAN) |
| Printer Support | Oki/HP PCL-compatible laser printers |
| Dimensions (W×D×H) | 397 × 365 × 667 mm |
| Weight | 30–35 kg |
| Brand | Forerunner |
|---|---|
| Model | WBS-100 |
| Origin | Beijing, China |
| Temperature Control Range | Room Temp to 60 °C |
| Temp. Accuracy | ±0.1 °C |
| Temp. Uniformity | ±0.3 °C |
| Heating Rate | 1.5 °C/min |
| Detection Cycle | 25 s per 40 cuvettes |
| Potency Calculation Time | <0.1 s |
| Absorbance Detection Precision | 0.001 A |
| Absorbance Repeatability | ±0.001 A |
| Potency Reproducibility | ≤0.5% |
| Multi-wavelength Light Source | Optional |
| UV Sterilization Lamp | Integrated |
| Audit Trail | Yes |
| User Access Control | Role-based authentication with password and RFID key |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Model | ZY-500 |
| Compliance | 21 CFR Part 11, JJF 1614–2017, USP <81>, EP 2.6.6, CP 2020 Vol II, AOAC 997.03, GB/T 5009.95–2003, SN/T 3979–2014 |
| Imaging Principle | Dual-source transmissive LED scanning with 12-line matrix CCD |
| Algorithm | AI-powered k-nearest neighbors (k-NN) image classification |
| Authentication | Fingerprint-based biometric user verification (up to 3 fingerprints per operator) |
| Security Architecture | Role-based three-tier access control, immutable audit trail, electronic signature, full data backup/recovery, write-once-read-many (WORM) raw data storage |
| Brand | Forerunner |
|---|---|
| Model | ZY-800KB |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Pricing | Available Upon Request |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN AGS |
| Light Source | 880 nm pulsed near-infrared LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Maximum Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5°C to 60°C |
| Temperature Accuracy | ±0.5°C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Scan Interval | As low as 20 s per scan |
| Programmable Scan Sequences | Up to 250 |
| Sample Capacity | 54 positions |
| Dimensions (W×D×H) | 145 × 75 × 85 cm |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Light Source | 880 nm pulsed near-infrared LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.01–1000 µm |
| Maximum Volume Concentration | up to 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Temperature Accuracy | ±0.5 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Modes | Full-height scanning (every 20 µm) or fixed-position kinetic monitoring |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Light Source | 880 nm pulsed NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.01–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | 4–80 °C |
| Temp. Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Scan Frequency | 1 scan per 20 s (at ambient) |
| Temp. Regulation Interval | Every 30 s |
| Max. Programmable Scan Steps | 250 |
| Sample Capacity | 6 positions |
| Dimensions (W×D×H) | 35 × 45 × 90 cm |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TRI-LAB |
| Light Source | 880 nm NIR LED |
| Sample Volume | 1.5–30 mL |
| Temperature Range | 20–60 °C |
| Sample Positions | 1–3 |
| Concentration Range | 0.0001–95% v/v |
| Detection Principle | Synchronized Transmittance (T) and Backscattering (BS) Profiling |
| Measurement Mode | Non-invasive, label-free, no dilution required |
| Compliance | Designed for GLP/GMP-aligned pharmaceutical stability assessment |
| Brand | Genphon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GF-WSW-3 |
| Filter Membrane Diameter | Φ47 mm or Φ50 mm |
| Effective Filtration Area | 40 mm diameter |
| Filter Cup Capacity | 150 mL (250 mL optional) |
| Number of Filtration Heads | 1 / 3 / 6 units |
| Detection Method | Membrane Filtration |
| Vacuum Source | External Vacuum Pump Required |
| Filtration Rate | 100 mL per 15 s (with membrane installed) |
| Sterilization Methods | Autoclavable (moist heat, 121°C, 30 min) and flame-sterilizable |
| Filtration Head Design | Modular, fully detachable and reassemblable |
| Brand | Glatt |
|---|---|
| Origin | Germany |
| Model | TMG |
| Working Vessel Gross Volume | 1–6 dm³ |
| Working Volume Range | 0.3–4.5 dm³ |
| Rotor Diameter | 170–230 mm |
| Rotor Speed (infinitely variable) | 50–1000 rpm |
| Chopper Speed (infinitely variable) | 300–3000 rpm |
| Motor Power | 1.1 kW |
| Dimensions (L×W×H) | 900 × 515 × 675 mm |
| Weight (empty unit) | ~140 kg |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Model | CD14 |
| Instrument Type | Offline Dissolution Tester |
| Vessel Capacity | 14 vessels |
| Temperature Range | 25.0–50.0 °C |
| Temperature Accuracy | ±0.1 °C (at 37 °C) |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Display Resolution | 0.1 rpm |
| Compliance | USP <711>, <724>, EP 2.9.3, JP XVII, ChP, ASTM E2503, FDA Mechanical Calibration Guidance, 21 CFR Part 11 |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flodex |
| Pricing | Available Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | G2 Autoplus / G2 Autofill |
| Instrument Type | Online Integrated Sampler & Collector |
| Compliance | FDA 21 CFR Part 11, USP <711>, <724>, ISO 9001, CE, CSA, RoHS |
| Sampling Channels | 6 or 8 (Autoplus) |
| Sampling Accuracy | ±1% |
| Minimum Sampling Interval | 2 min (down to 1 min under controlled conditions) |
| Maximum Sample Points per Run | 50 |
| Syringe Volumes | 5 mL or 10 mL (inert fluid path) |
| Valve Configuration | 4-channel solenoid manifold (expandable to 16- or 24-position dissolution systems) |
| Control Interface | Full-color capacitive touchscreen |
| Program Storage | Up to 100 user-defined dissolution methods |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Regulatory Features | Audit trail, electronic signatures, calibration/ maintenance prompts, solvent replenishment & auto-rinse protocols |
| Rack Compatibility | 16×100 mm UV cuvette racks, 12×32 mm HPLC vials, 12×32 mm UPLC vials, 6×8 multi-position trays |
| Integrated Filtration | In-line sterile-grade filtration module |
| Software Architecture | 32-bit embedded control firmware with deterministic real-time sampling logic |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PHOENIX DB-6 |
| Pricing | Available Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PHOENIX RDS |
| Pricing | Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Model | Vision G2 Elite 8 / Vision G2 Classic 6 |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 or 8 |
| Temperature Range | 25–55 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Basket/Paddle Wobble | 0 mm |
| Bath Volume | 11.4 L (Classic 6) / 18.9 L (Elite 8) |
| Compliance | Fully compliant with 21 CFR Part 11 |
| Data Interface | RS232, USB, LAN |
| Onboard Storage | Up to 100 programmable dissolution methods |
| Power Supply | 220 V AC, 50–60 Hz, 65 W |
| Brand | HU CHUAN / HC |
|---|---|
| Origin | Jiangsu, China |
| Model | HCN-48 |
| Temperature Control Range | Ambient +5°C to 160°C |
| Temperature Accuracy | ±0.5°C (@40°C), ±1°C (@120°C) |
| Temperature Uniformity | ±0.5°C |
| Display Resolution | 0.1°C |
| Timer Range | 1–99 h 59 min or continuous (∞) |
| Heating Time | ≤15 min (25°C → 160°C) |
| Block Configuration | Dual 24-well modules (total 48 wells) |
| Rated Power | 500 W |
| Voltage | 220 V, 50/60 Hz |
| Dimensions | 260 × 220 × 100 mm |
| Weight | 5.0 kg |
| Brand | Heguan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HGK-81 |
| Pricing Range | USD 9,500 – 15,200 (FOB Shanghai) |
| Product Type | Intelligent Automated SO₂ Distillation Analyzer |
| Detection Limit | RSD ≤ 5% (repeatability), Parallel Difference ≤ 10% (with 5 mL standard alkali consumption) |
| Detection Range | 0–50 mg SO₂ per sample |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | HM-KSS |
| Price | USD 1,100 (FOB Qingdao) |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-STY1 |
| Price | USD 4,500 (FOB) |
| Measurement Principle | Cryoscopic Depression of Freezing Point |
| Compliance | JJG 1089–2013, Chinese Pharmacopoeia 2025, ISO 17511 (traceability framework), USP <785> |
| Detection Speed | Up to 50 samples/h |
| Range | 0–3000 mOsmol/kg |
| Sample Volume | 50–100 µL |
| Resolution | 0.005 mOsmol/kg |
| Accuracy | ±6 mOsmol/kg (≤400) or ±1.5% (>400) |
| Repeatability | ≤2 mOsmol/kg (≤400) or CV ≤0.75% (>400) |
| Stability | ≤2 mOsmol/kg (at 300 mOsmol/kg, 8-h drift) |
| Cooling Time | ≤5 min |
| Operating Environment | 5–35°C, 5–80% RH (non-condensing), <2000 m altitude |
| Dimensions (D×W×H) | 360 × 300 × 240 mm |
| Weight | 7 kg |
| Data Interface | USB 2.0, 10/100 Mbps Ethernet, Wi-Fi 802.11 b/g/n, optional 4G LTE |
| Onboard Printer | Thermal, 57 mm paper roll |
| Power Input | 100–277 VAC, 50/60 Hz, 220 W max |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HM-YNQ2 |
| Price | USD 10,800 (FOB Qingdao) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter 0613 |
| Display | 7-inch industrial-grade color TFT touchscreen (Chinese UI) |
| Control System | Industrial PLC |
| Cooling Range | Ambient to –90 °C (with optional low-temp bath) |
| Heating Range | Up to +90 °C |
| Temperature Resolution | 0.1 °C |
| Sensor Type | High-accuracy platinum RTD (Pt100) with built-in calibration offset correction |
| Bath Configuration | Dual independent test ports in single thermostatic bath |
| Stirring Mechanism | Motor-driven mechanical stirrer, 60 cycles/min, synchronized with phase transition detection |
| Bath Media Compatibility | Water, ethylene glycol antifreeze, ethanol, or other low-viscosity, non-corrosive thermal fluids |
| Data Output | Integrated thermal line printer (fast, smudge-resistant) |
| Data Storage | Internal memory for ≥1,000 test records with timestamp, sample ID, and full cooling curve metadata |
| Operating Environment | 5–30 °C, 30–70% RH |
| Construction | Vacuum-insulated Dewar-style bath vessel (borosilicate glass inner, stainless steel outer jacket) |
| Brand | Herolab |
|---|---|
| Origin | Germany |
| Model | PM-200 |
| Detection Principle | Light Obscuration (LO) |
| Particle Size Range | 1–200 µm or 2–400 µm (user-selectable) |
| Concentration Range | 0–70,000 particles/mL |
| Minimum Sample Volume | 100 µL |
| Measurement Accuracy | >95% |
| Compliance | USP <787>, <788>, <789>, <1787>, <1788> |
| Software | SW-CA with Audit Trail, Electronic Signatures, and Secure Data Management |
| Syringe Compatibility | 1 mL, 5 mL, 10 mL, 25 mL (interchangeable) |
| Interface | USB |