| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SDC-6 |
| Configuration | Water-jacketed horizontal diffusion cell system |
| Temperature Control | Dual-zone independent heating (each zone controls 3 diffusion cells) |
| Cell Orientation | Horizontal |
| Primary Application | In vitro permeation testing (IVPT) of ophthalmic solutions, lotions, washes, and topical formulations |
| Compliance Context | Designed to support USP <724> and OECD TG 428 guidelines |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 4000 |
| Instrument Type | Online Flow-Through Dissolution System |
| Temperature Range | Ambient to 45 °C |
| Temperature Accuracy | ±0.1 °C |
| Flow Rate Control Modes | Constant Flow or Pulsed Flow (user-selectable) |
| Flow Cell Options | 12 mm, 22.6 mm, Powder Cell, Suppository Cell, Granule Cell |
| Number of Parallel Flow Channels | 8 |
| Bath Volume | 20 L |
| Bath Temperature Resolution | 0.1 °C |
| Shaft Wobble Tolerance (Paddle/Rotating Basket) | ≤1 mm |
| Motor Speed | 500 rpm (50 Hz), 600 rpm (60 Hz) |
| Compliance | Fully compliant with USP <4>, USP <711>, and FDA 21 CFR Part 11 requirements for audit trail, electronic signature, and data integrity |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL |
| Instrument Type | Online Dissolution Testing System |
| Dissolution Vessels | 8-position |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL-12 |
| Instrument Type | Online Dissolution Tester |
| Vessel Positions | 8 or 12 |
| Temperature Range | Ambient to 45 °C ±0.1 °C |
| Rotation Speed Range | 25–250 rpm ±0.1 rpm |
| Pump Configuration | 12-channel syringe pump (12 × 10 mL) |
| Compliance | USP <711>, <724>, <723>, <725>, <731> |
| Integrated Modules | UDT-812A-12 dissolution apparatus, SCR-160L sample collector, SYP-6L 12-channel syringe pump, DSC-800D sampling controller |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DLA |
| Instrument Type | Online Dissolution System |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 860CDL |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 30 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYSTEM 860CDL |
| Instrument Type | Online Dissolution System |
| Dissolution Vessels | 12 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 30 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYSTEM 860DL |
| Instrument Type | Online Dissolution System |
| Number of Vessels | 12 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 30 L |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail and role-based access control |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 860DL |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 30 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 860DLA |
| Instrument Type | Online Dissolution Sampling System |
| Vessel Capacity | 12-position |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, Role-Based Access Control) |
| Modular Configuration | UDT-818A Dissolution Apparatus, SCR-DL Sample Collector, SYP-12L-10mL Precision Syringe Pump, DSC-800 System Controller |
| Temperature Monitoring | 12 independent RTD probes per vessel |
| Filtration | Dual-stage inline filtration (pre- and post-sampling) |
| Fluid Handling | Auto-replenishment, isothermal media replacement, sample filtration, and volume compensation |
| Integration Capabilities | UV/Vis spectrophotometers, HPLC autosamplers, fiber-optic probes, dilution modules, and permeation systems (e.g., PAMPA, Caco-2) |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 913A-12 |
| Configuration | Dual-FDC-6TA + SCR-DL + SYP-12L-10mL + DSC-800 Controller |
| Sample Capacity | 12 stations |
| Temperature Control | Dual-zone water-jacketed heating |
| Compliance | FDA 21 CFR Part 11 (audit trail, 3-tier user permissions) |
| Automation | Auto-degassing interface optional |
| Sampling | Programmable syringe pump (10 mL), auto-bubble purge, timed sequential sampling |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SYSTEM 914-12 |
| Pricing | Upon Request |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 918-12 |
| Configuration | Dual DHC-6TD dry-heated diffusion stations + SCR-DL sample collector + SYP-12L-10mL precision syringe pump + DSC-800 system controller |
| Sample Capacity | 12 parallel diffusion cells |
| Heating Method | Dry-heated (Peltier-based thermal control) |
| Temperature Monitoring | Real-time acceptor medium temperature sensing |
| Compliance | FDA 21 CFR Part 11 compliant with audit trail and three-tier user access control |
| Optional Accessories | Epidermal surface temperature probe, variable-speed magnetic stirrer modules, in-line solvent degassing unit |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 918-12 |
| Configuration | Dual DHC-6TD dry-heated diffusion stations + SCR-DL sample collector + SYP-12L-10mL precision syringe pump + DSC-800 system controller |
| Compliance | FDA 21 CFR Part 11 (audit trail, 3-tier user permissions) |
| Heating Method | Dry-heated (Peltier or resistive, contactless thermal regulation) |
| Capacity | 12 simultaneous diffusion cells |
| Sample Volume Control | Interchangeable silicone gaskets for precise dosing |
| Temperature Monitoring | Real-time acceptor medium temperature sensing per cell |
| Optional Modules | Epidermal surface temperature probe, variable-speed magnetic stirring, in-line solvent degassing unit |
| Regulatory Alignment | Designed to support GLP-compliant transdermal permeation studies per USP <724>, ASTM E2757, and ICH Q5C guidelines |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM ADIS 1200 |
| Instrument Type | Online Dissolution Analyzer |
| Configuration | 12-Position Fully Automated System |
| Compliance | Designed for USP <711>, <724>, <1092>, and FDA Guidance on Dissolution Testing |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM ADR III-7 |
| Instrument Type | Online Dissolution Testing System |
| Dissolution Vessels | 8 vessels per rack × 6 racks (48 total) or 12 vessels per rack × 12 racks (144 total) |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 28 L |
| Compliance | USP <711>, <724>, <725>, EP 2.9.3, JP 17 |
| Data Integrity | 21 CFR Part 11-compliant audit trail, role-based user access control, electronic signatures |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM ADR III-7 |
| Instrument Type | Online Dissolution Testing System |
| Vessel Configuration | 8 vessels/row × 6 rows or 12 vessels/row × 12 rows |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Bath Temperature Range | Ambient to 45°C |
| Bath Temperature Resolution | 0.1°C |
| Bath Volume | 28 L |
| Compliance | USP <711>, <724>, EP 2.9.3, JP 17 |
| Data Integrity | 21 CFR Part 11, GLP/GMP Audit Trail, Role-Based Access Control, Electronic Signatures |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM UV 1900-12 |
| Instrument Type | Online Dissolution Analyzer |
| Configuration | Modular, Fully Automated 12-Station System |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, Role-Based Access Control) |
| Detection Method | UV-Vis Spectrophotometry (Fixed-Wavelength or Scanning Mode) |
| Sampling Mechanism | High-Precision Peristaltic/Injection Pump (SYP-1200 Series) |
| Temperature Monitoring | 12 Independent RTD Probes per Vessel |
| Flow Cell Pathlengths | 2 mm, 5 mm, 10 mm (Standardized to USP <711>, <724>, <731>) |
| Filtration | Dual-Stage In-Line Filtration (0.45 µm + 0.22 µm) |
| Regulatory Alignment | USP, Ph. Eur., JP, ISO 16850, ASTM E2503 |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-812A-12 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-812A-8 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-818A-12 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 12 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | UDT-818A-8 |
| Instrument Type | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | MATHIS |
|---|---|
| Origin | Canada |
| Model | ESP™ |
| Application Domain | In-line blend uniformity monitoring for solid dosage forms |
| Measurement Principle | Differential thermal sensing (calorimetric-based mixing signature analysis) |
| Sample Forms | Dry powders, granules, semi-solids, suspensions, waxy matrices |
| Compliance Context | Designed to support FDA Process Analytical Technology (PAT) initiative, aligned with ICH Q8(R2), Q9, and Q10 |
| Brand | ProteinSimple |
|---|---|
| Origin | USA |
| Model | Maurice |
| CE-SDS Mode | UV Detection, Reduced & Non-reduced Conditions |
| iCIEF Mode | Full-Column Imaging Capillary Isoelectric Focusing |
| Cartridge Type | Pre-assembled, Plug-and-Play Capillary Cartridges |
| Run Time (CE-SDS) | 5–7 h for 12 injections |
| Run Time (iCIEF) | 6–10 min per injection |
| Precision (iCIEF pI RSD) | <0.1% over 100 runs |
| Precision (CE-SDS Peak Area RSD) | <1% over 24 consecutive runs |
| Compliance | Designed for USP <1054>, ICH Q5E, Q5B, ASTM D8294-20, and aligned with FDA 21 CFR Part 11 data integrity requirements |
| Brand | Topo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RD-2 |
| Pricing | Upon Request |
| Control Mode | Intelligent Manual Operation |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Model | CTC 256 / TTC 256 |
| Temperature Range (dry) | −42 °C to +190 °C |
| Temperature Range (humidified) | +10 °C to +95 °C |
| Humidity Range | 10 %rh to 98 %rh |
| Cooling Rate | 80 min (180 °C → −40 °C) |
| Heating Rate | 20 min (−40 °C → 180 °C) |
| Insulation | Triple-layer aerospace-grade vacuum-insulated walls |
| Refrigeration | Dual parallel compressors with electronic refrigerant metering |
| Defrost | Automatic cyclic defrost system |
| Evaporator | Stainless steel |
| Noise Level | <60 dB(A) |
| Compliance | DIN EN 60068-2-1, -2-2, -2-3 |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Type | Imported |
| Model | HPP1060eco |
| Pricing | Upon Request |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Type | Import |
| Model | HPP110eco |
| Pricing | Upon Request |
| Brand | Memmert |
|---|---|
| Origin | Germany |
| Manufacturer | Memmert GmbH & Co. KG |
| Type | Import |
| Model | HPP1400eco |
| Pricing | Upon Request |