Pharmaceutical Testing Specialized Instruments
Filter
Showing 121–150 of 364 results
| Brand | Hinds Instruments |
|---|---|
| Origin | Shanghai, China |
| Model Variants | YP-SD150, YP-SD250, YP-SD500, YP-SD1000, YP-SDP150, YP-SDP250, YP-SDP500, YP-GSP150, YP-GSP250, YP-GSP500 |
| Capacity | 150 L / 250 L / 500 L / 1000 L |
| Temperature Range | 0–65°C (dark), 10–65°C (with illumination) |
| Temperature Uniformity | ±0.5°C |
| Humidity Range | 30–95% RH |
| Humidity Uniformity | ±0.5% RH |
| Illuminance Range | 0–6000 lx (adjustable) |
| Illuminance Accuracy | ≤ ±500 lx |
| Control Resolution | 0.1°C / 0.1% RH |
| Refrigeration System | Hermetic Danfoss compressor (R404A/R23 refrigerant) |
| Cooling Capacity | 90–150 W @ −25°C to +55°C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Safety Protections | Compressor overheat, overload, water shortage, overtemperature, electrical short-circuit |
| Compliance | Chinese Pharmacopoeia (2010 Edition) Stability Guidelines, GB/T 10586–2018 Environmental Test Equipment General Specifications |
| Construction | Mirror-finish SUS304B interior, arc-shaped cabinet design, double-glazed vacuum-insulated observation window |
| Air Circulation | Optimized ducted convection system for high spatial uniformity |
| Standard Accessories | 2 adjustable stainless-steel shelves, left-side test lead port, PID-tuned Fuji controller with touchscreen interface |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-06S |
| Measurement Range | 1–500 µm |
| Channel Options | ≥5, ≥8, ≥10, ≥12, ≥25, ≥100 µm (customizable) |
| Pharmacopoeia-Compliant Channels | ≥10 µm, ≥25 µm |
| Sample Volume Range | 0.1–1000 mL |
| Minimum Sample Volume | ≥0.1 mL |
| Volume Accuracy | < ±0.5% |
| Counting Range | 0–9,999,999 particles |
| Particle Concentration Range | 0–10,000 particles/mL |
| RSD | ≤2% (for standard particles ≥1000 particles/mL) |
| Sampling Time | <8 s for 5 mL |
| Time Accuracy | ±5% of set value |
| Channel Resolution | ≥95% (≥10 µm channel) |
| Stirring Speed | 0–2000 rpm, continuously adjustable |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤90 W |
| Dimensions | 360 × 330 × 415 mm |
| Brand | Huiron |
|---|---|
| Model | HRH-BRM-2100 |
| Origin | Beijing, China |
| Tidal Volume Range | 0–1000 mL |
| Accuracy | ±5% of full scale or ±1 mL (whichever is greater) |
| Power Supply | 220 V, 50 Hz |
| Dimensions | 70 × 35 × 62 cm |
| Weight | 35 kg |
| Compliance | USP <601>, Ph. Eur. 2.9.43, ChP 2020 Vol. IV <0951> |
| Predefined Breathing Profiles | Adult / Pediatric / Infant / Neonatal |
| Customizable Parameters | Tidal Volume, Breathing Frequency, I:E Ratio, Flow Profile Shape, Cycle Count |
| Real-time Output | Flow Rate Curve, Tidal Volume Curve, Respiratory Parameter Summary |
| Brand | Huironghe |
|---|---|
| Model | HRH-20 |
| Origin | Beijing, China |
| Type | In Vitro–In Vivo Correlation (IVIVC) Simulation System for Orally Inhaled Products (OIPs) |
| Airflow Range | 0–100 L/min |
| Peak Inspiratory Flow Rate Simulation | 0–100 L/min |
| Flow Acceleration Rate | 0–15 L/s² |
| Respiratory Waveform Customization | Yes |
| Compliance Reference | Good Cascade Impactor Practices (GCIP), AIM & EDA Guidelines for Orally Inhaled Products (2013) |
| Intended Use | IVIVC development, aerodynamic particle size distribution (APSD) testing, delivered dose uniformity (DDU) assessment |
| Brand | Innuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPT-C2 |
| Pricing | Available Upon Request |
| Brand | IRM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MST260 |
| Pricing | Available Upon Request |
| Internal Volume | 305 L |
| Internal Dimensions (W×D×H) | 640 × 450 × 1060 mm |
| External Dimensions (W×D×H) | 780 × 790 × 1600 mm |
| Temperature Range | 0–80 °C (dark), 10–80 °C (with illumination) |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ≤ ±0.1 °C |
| Humidity Range | 20–98 %RH |
| Humidity Uniformity | ≤ ±1 %RH |
| Illumination Intensity | 0–6000 lx (±300 lx accuracy) |
| Refrigerant | R134a or R22 |
| Heating & Humidification Power | 2.0 kW |
| Cooling Capacity | 280 W |
| Power Supply | AC 220 V, 2.2 kW |
| Water Tank Capacity | 20 L |
| Standard Shelves | 2 (up to 20 configurable) |
| Weight | ~193 kg |
| Test Port | Two Ø50 mm ports (left/right) |
| Control Interface | 7-inch capacitive touchscreen |
| Operating Modes | Constant, Timer, Programmable (1–30 segments) |
| Data Logging | Event log, alarm history, real-time trend curves |
| Data Export | USB flash drive |
| Safety Protections | Leakage protection circuit breaker, independent over-temperature cutoff, water-level monitoring (low-level & overflow), compressor high-pressure/overheat protection, fan overheat protection, door-open alarm, power-failure alarm, sensor fault detection |
| Compliance Features | Audit trail, electronic signature support, 3-tier user permission system (Operator/Supervisor/Administrator), operation log with timestamp and user ID |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AIpol-JHD50 |
| Price | Upon Request |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rate | 0.1–20 °C/min (200-step continuous adjustment) |
| Accuracy | ±0.2 °C (<250 °C), ±0.4 °C (>250 °C) |
| Repeatability | ±0.1 °C at 0.1 °C/min |
| Sample Capacity | 2 parallel channels (2 drop point cups: 2.8 mm orifice |
| 2 softening point cups | 6.35 mm orifice) |
| Optical Magnification | Standard 9×, adjustable |
| Display | 10.4″ FTF color touchscreen |
| Data Storage | 64 GB internal |
| Method Library | 600 preloaded, user-lockable |
| User Management | 4-tier permission control |
| Audit Trail | Compliant with FDA 21 CFR Part 11 |
| Electronic Signature | Enabled |
| Data Export Formats | PDF, Excel |
| Connectivity | USB, RS232, SD card, Wi-Fi, RJ45, U-disk interface |
| Barcode Scanner Support | Yes |
| Power Supply | 110–230 V AC, 50/60 Hz, 120 W |
| Dimensions (W×D×H) | 430 × 320 × 370 mm |
| Net Weight | 6.5 kg |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JH-D2102 |
| Price Range | USD 1,400 – 2,800 |
| Measurement Principle | Ring-and-Ball Method (ASTM D36 / ISO 4625 / ChP 2020 General Chapter 2102 / USP <741>) |
| Temperature Range | 5–80 °C (water bath) / 32–162 °C (glycerol bath) |
| Temp. Resolution | 0.1 °C |
| Heating Rate | 1.0–1.5 °C/min (linear ramp, PID-controlled) |
| Sample Capacity | 2 specimens simultaneously |
| Stirring | Adjustable magnetic stirrer (infinitely variable speed) |
| Detection Method | Dual-channel laser beam interruption detection |
| Data Storage | 200 test records (CSV export via USB) |
| Compliance | Fully compliant with ChP 2020 Edition General Chapter 2102, supports audit trail per FDA 21 CFR Part 11 requirements |
| Interface | RS-485 (Modbus RTU) |
| Dimensions (L×W×H) | 390 × 300 × 575 mm |
| Weight | 12.0 kg |
| Power Supply | 220 ±10% VAC, 50 Hz |
| Max. Power Consumption | ≤800 W |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JHD50 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±0.2 °C (≤250 °C), ±0.5 °C (>250 °C) |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | 2 samples per run |
| Display | Dual-screen — 5.6″ + 4.3″ color TFT LCD |
| User Accounts | Up to 15 |
| Predefined Methods | 100 stored protocols |
| Data Interfaces | USB, RS-232, Ethernet |
| GLP Compliance | Yes |
| Power Supply | 220 V, 50 Hz, 120 W |
| Standards Compliance | ASTM D3204, D3461, D3104, D3954, D6090 |
| ISO 2176 | 1972, 4625:2 |
| Brand | JIAXINHAI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BJ-1 |
| Temperature Set Range | 20–50°C |
| Temperature Resolution | 0.1°C |
| Temperature Control Accuracy | ±0.3°C |
| Timer Set Range | 1–900 min |
| Timing Accuracy | ±0.5 min |
| Noise Level | <60 dB(A) |
| Basket Lift Frequency | 30–31 cycles/min |
| Basket Stroke | (55 ± 1) mm |
| Distance from Sieve to Beaker Bottom | (25 ± 2) mm |
| Standard Sieve Aperture | 2 mm |
| Optional Sieve Apertures | 0.425 mm, 1 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 600 W |
| Dimensions (L×W×H) | 260 × 300 × 440 mm |
| Brand | JIAXINHAI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CS-2 |
| Rotation Speed | 25 rpm ±1 rpm |
| Drum Quantity | 2 |
| Drum Internal Diameter | 286 mm |
| Drum Depth | 39 mm |
| Drop Height | 156 mm |
| Pre-set Revolution Count | 100 revolutions (downward counting) |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 20 W |
| Dimensions (L×W×H) | 370 mm × 300 mm × 340 mm |
| Display | LCD with simultaneous preset/real-time value display |
| Drum Material | High-transparency optical-grade acrylic |
| Control System | Microcontroller-based intelligent control |
| Compliance | Meets requirements of ChP (Chinese Pharmacopoeia), USP <1216>, and EP 2.9.7 |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RBY-4B |
| Price | USD 1,880 (FOB Tianjin) |
| Brand | JIAXINHAI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YB-2A Stainless Steel |
| Power | 20 W |
| Lamp | 20 W Tri-phosphor Fluorescent Tube with Electronic Ballast |
| Illuminance Range | 1000–6000 lx |
| Timing Range | 1–99 s (adjustable) |
| Dimensions | 703 mm × 175 mm × 513 mm |
| Background | Black遮光板 + White Inspection Plate |
| Compliance | Chinese Pharmacopoeia (ChP) General Chapter <0902> |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ZPJ-2 |
| Price | USD 1,500 (approx.) |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZPJ-4 |
| Price | USD 2,200 (FOB Tianjin) |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CQD-2A |
| Measurement Principle | 90° Nephelometric Scattering |
| Light Source | 860 nm LED |
| Range | 0–10 NTU / 10–100 NTU / 100–1000 NTU (Auto-ranging) |
| Resolution | 0.01 NTU (0–10), 0.1 NTU (10–100), 1 NTU (100–1000) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% F.S. |
| Calibration Points | 1–5-point automated calibration |
| Interface | USB |
| Operating Temperature | Ambient to 65°C |
| Power Supply | 220 V, 50 Hz |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RBY-4 |
| Pricing | Upon Request |
| Temperature Control Accuracy | 37 °C ± 0.3 °C |
| Temperature Set Range | 30–40 °C |
| Cylinder Dimensions | Ø52 mm × 60 mm |
| Metal Rack Dimensions | Ø50 mm, Aperture Ø4 mm, Plate Spacing 30 mm |
| Disintegration Time Programs | P1 (30 min, rack inversion every 10 min), P2 (60 min, rack inversion every 10 min), P3 (30 min, no inversion) |
| Beaker Capacity | 5 L (3 standard beakers included) |
| Heating Power | 1300 W |
| Power Supply | 220 V ± 10 %, 50 Hz |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | KB-1 |
| Price Range | USD 495 – 705 |
| Disintegration Basket | Stainless Steel, 30 mm Length, 13 mm Inner Diameter, 710 µm Aperture |
| Stroke Frequency | 30 cycles/min |
| Vertical Travel Distance | 10 mm ± 1 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | RBY-4B |
| Number of Test Stations | 3 |
| Cylinder Height | 60 mm |
| Cylinder Inner Diameter | 52 mm |
| Stainless Steel Mesh Disk Diameter | 50 mm |
| Mesh Hole Count per Disk | 39 |
| Mesh Hole Diameter | 4 mm |
| Timer Range | 10–900 min |
| Timer Accuracy | ±0.5 min |
| Temperature Control Range | 20–45 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Water Bath Capacity | 5 L × 3 |
| Power Supply | 220 V / 50 Hz / 1000 W |
| Circulation System | Magnetic Drive Pump with Uniform Thermal Distribution |
| Operation Modes | P1 (30 min, flip every 10 min), P2 (60 min, flip every 10 min), P3 (30 min, no flip) |
| Dual-Mode Head Actuation | Motorized Vertical Lift + Manual Flip Mechanism |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | RTQ-A Solvent Degassing System |
| Vacuum Range | −95 kPa to −98 kPa |
| Membrane Pore Size | 0.01 µm – 0.2 µm |
| Membrane Surface Area | 15 m² |
| Degassing Efficiency | ≥85% (single-stage), ≥95% (dual-stage optional) |
| Flow Rate | 1 L/min |
| Outlet Temperature Range | Ambient to 50 °C |
| pH Compatibility | 1–14 |
| Max. Total Throughput | 50,000 L |
| Temp. Resolution | 0.01 °C |
| Flow Resolution | 0.001 L |
| Vacuum Resolution | 1 kPa |
| User Access Levels | 3-tier, 7-user |
| Audit Trail Capacity | 128 entries × 366 days |
| Interface Options | RS-232 |
| Power Input | 2000 W, 220 V AC, 10 A socket compatible |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YD-35 |
| Hardness Range | 1–350 N |
| Resolution | 0.1 N |
| Accuracy | ±0.03 kg (equivalent to ±0.3 N) |
| Diameter Measurement Range | 2.0–30.0 mm |
| Diameter Accuracy | ±0.01 mm |
| Units | N / kg / Sc (hardness), mm / inch (diameter) |
| Measurement Modes | Manual single-tablet, automatic batch (up to 160 tablets) |
| Display | LCD, 4×8 Chinese or 8×16 English |
| Data Output | Statistical analysis, timestamped reporting, calibration logging, self-diagnosis, auto-save parameters |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ZKT-18F |
| Temperature Control Range | 37–45 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Vacuum Control Range | 0.02–0.05 MPa |
| Vacuum Resolution | 0.01 MPa |
| Sample Volume Capacity | 7 L or 21 L (selectable internal reservoir configuration) |
| Heating Power | 1500 W |
| Integrated Vacuum Pump | Yes |
| UV Sterilization Module | Included |
| Compliance | Meets requirements of Chinese Pharmacopoeia 2020 Edition (General Chapter <0931> “Dissolution Testing” and <0632> “Degassing of Solvents”) |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | ZKT-25 |
| Price | Upon Request |
| Temperature Range | 37–45 °C, Resolution: 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Vacuum Range | 0.02–0.05 MPa, Resolution: 0.01 MPa |
| Max. Volume Capacity | 25 L |
| Liquid Transfer Precision | ±0.1 L |
| Heating Power | 1500 W |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 5–40 °C, RH ≤80% |
| UV Sterilization | Integrated |
| User Account Management | Multi-user login with audit trail |
| Compliance | Meets Chinese Pharmacopoeia requirements for degassing of non-volatile dissolution media |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZPJ-2 |
| Pricing | Available Upon Request |
| Drum Quantity | 2 |
| Drum Internal Diameter | 286 mm |
| Drum Depth | 39 mm |
| Drop Height | 156 mm |
| Drum Rotation Speed | (25 ± 1) rpm |
| Total Rotations | (100 ± 1) cycles |
| Hardness Measurement Range | 2–199 N (±1 N accuracy) |
| Tablet Diameter Compatibility | 3–40 mm |
| Power Supply | 220 V / 50 Hz / 600 W |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | ZPJ-6 |
| Dissolution Vessels | 6 |
| Temperature Control Range | 20–40 °C ±0.3 °C |
| Rotation Speed (Paddle/Basket) | 20–200 rpm ±2 rpm |
| Timing Range | 1–900 min ±0.5 min |
| Paddle Shaft Wobble | ±0.5 mm |
| Basket Wobble | ±1.0 mm |
| Disintegration Baskets | 2 |
| Reciprocating Frequency | 30–32 cycles/min |
| Stroke Distance | 55 mm ±2 mm |
| Friability Drums | 2 |
| Drum Inner Diameter | 286 mm |
| Drum Depth | 39 mm |
| Drop Height | 156 mm |
| Drum Rotational Speed | 25 rpm ±1 rpm |
| Drum Revolutions | 100 ±1 cycles |
| Hardness Measurement Range | 2–199 N ±1 N |
| Tablet Diameter Compatibility | 3–40 mm |
| Power Supply | 220 V / 50 Hz / 600 W |
| Dimensions (W×D×H) | 52×58×47 cm³ |
| Brand | Josvok |
|---|---|
| Origin | Tianjin, China |
| Model | YD-35 |
| Hardness Range | 1–350 N (Resolution: 0.1 N, Accuracy: ±0.03 kg) |
| Diameter Range | 2.0–30.0 mm (Accuracy: ±0.01 mm) |
| Units | N / kg / Sc (hardness), mm / inch (diameter) |
| Measurement Modes | Manual single-tablet, Automatic batch (up to 160 tablets) |
| Display | LCD, 4×8 Chinese or 8×16 English |
| Data Output | Statistical analysis, timestamped reporting, calibration logging, self-diagnostic alerts |
| Compliance | Designed for pharmacopeial compliance per USP <1217>, EP 2.9.8, and ChP IV |
| Brand | Josvok |
|---|---|
| Origin | Tianjin, China |
| Model | ZB-1D |
| Temperature Range | 5.0 °C (or ambient) to 40.0 °C (0.1 °C resolution) |
| Temperature Accuracy | ±0.5 °C |
| Timing Range | 0–600 minutes (1-minute resolution) |
| Basket Stroke Frequency | 30–32 cycles/min |
| Basket Stroke Amplitude | 55 mm ±1 mm |
| Distance from Sieve to Beaker Bottom | 25 mm ±2 mm |
| Sieve Aperture Options | 2.0 mm and 0.425 mm |
| Brand | Josvok |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZPJ-4 |
| Price | USD 2,050 (FOB Tianjin) |
| Temperature Control Range | 20–40 °C ±0.3 °C |
| Speed Adjustment Range | 20–200 rpm ±2 rpm |
| Timing Range | 1–900 min ±0.5 min |
| Paddle Wobble | ±0.5 mm |
| Basket Wobble | ±1.0 mm |
| Disintegration Stations | 2 |
| Reciprocating Frequency | 30–32 cycles/min |
| Stroke Distance | 55 mm ±2 mm |
| Friability Drum | 1 unit, internal diameter 286 mm, depth 39 mm, drop height 156 mm, rotation speed 25 rpm ±1 rpm, total revolutions 100 ±1 |
| Hardness Measurement Range | 2–199 N ±1 N |
| Tablet Diameter Compatibility | 3–40 mm |
| Power Supply | 220 V / 50 Hz / 600 W |
| Dimensions (W×D×H) | 520 × 380 × 470 mm |
| Brand | Josvok |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZSO2-3000A |
| Detection Limit | 1 µg |
| Detection Range | 1–1000 µg |
| Instrument Type | Benchtop Dedicated Analyzer |
| Heating Method | Infrared Ceramic Heating (Flameless) |
| Display | LCD Touchscreen Interface |
| Cooling Option | External or Optional Built-in Recirculating Chiller |
| Nitrogen Flow Control | Precision Mass Flow Regulator |
| Power Control | Adjustable Independent Heating Zones with Countdown Timer and Audible Alert |
| Brand | JTONE |
|---|---|
| Origin | Beijing, China |
| Model | SO2-3000 |
| Detection Target | Sulfur Dioxide (SO₂) |
| Detection Range | Ammonia Nitrogen, Volatile Phenols |
| Detection Principle | Acid Distillation–Iodometric Titration (Standard Pharmacopoeia Method) |
| Distillation Units | 3 |
| Heating Temperature Control Range | Up to 200 °C |
| Heating Method | Sealed Infrared Ceramic Heater |
| Cooling System | External Recirculating Chiller (Optional Internal Chiller) |
| Nitrogen Flow Control | Individual Precision Mass Flow Meters per Channel |
| Power Rating | 1850 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Dimensions (L×W×H) | 800 × 520 × 850 mm |
| Safety Features | Leakage Protection, Dry-Run Prevention |
| Standard Flask Configuration | 1000 mL Distillation Flasks × 3, 100 mL Conical Receivers × 3 |
| Display | LCD Touchscreen Interface |
| Compliance | Designed for Chinese Pharmacopoeia (ChP) 2020 Edition Method II (SO₂ Residue Determination), Compatible with USP <231>, EP 2.4.24, and ISO 5840:2016 (SO₂ in Herbal Materials) |