Physical Property Testing Instruments
Filter
Showing 3151–3180 of 4386 results
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Detection Method | Pulse-Echo Ultrasonic (Conventional & Phased Array) |
| Channel Capacity | Up to 4 Channels |
| Inspection Sensitivity | 0.5 mm × 0.5 mm Flat-Bottom Hole (FBH) Equivalent |
| Material Compatibility | Bearing Steel (e.g., GCr15, SUJ2), Alloy Steels, Hardened & Ground Surfaces |
| Automation Interface | Robotic Arm / Overhead Crane Integration with Machine Vision Guidance |
| Software Platform | Proprietary Real-Time UT Control & Analysis Suite |
| Compliance Framework | Supports ASTM E114, ISO 16847, EN 1330-4, and GLP/GMP-aligned audit trail requirements |
| Connectivity | OPC UA, RESTful API, MES/SCADA Integration Ready |
| Remote Operation | Web-based supervisory control with TLS-secured streaming |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | BondMaster 600 |
| Compliance | MIL-STD-810G, IP66, CE, FCC, IC, RoHS, RCM, KCC |
| Display | 5.7" VGA (640 × 480) color transflective LCD |
| Weight | 1.70 kg (with Li-ion battery) |
| Dimensions | 236 mm × 167 mm × 70 mm |
| Battery Life | Up to 9 hours |
| Operating Temperature | –10 °C to 50 °C |
| Storage Temperature | 0 °C to 50 °C (with battery) |
| Probe Interface | 11-pin Fischer |
| Gain Range | 0–100 dB (0.1/1 dB steps) |
| Frequency Ranges | RF/Pulse: 1–50 kHz |
| Sweep | 1–100 kHz |
| MIA | 2–50 kHz |
| Resonance | 1–500 kHz |
| Data Storage | 500 files (user-selectable preview) |
| Supported Probes | PowerLink-compatible transducers, standard dual-element probes, MIA-specific probes (B600M), resonance probes (B600M) |
| Software | BondMaster PC Software (included), supports report generation, data review, and GLP-compliant audit trail export |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom OEM System |
| Quotation | Upon Request |
| Application Field | Wind Power Component Quality Assurance |
| Channel Capacity | Up to 4 Channels |
| Inspection Method | Pulse-Echo Ultrasonic Testing with Equivalent Flaw Sizing (FBH Reference) |
| Minimum Detectable Flaw | 0.5 mm × 0.5 mm Flat-Bottom Hole (FBH) |
| Probe Compatibility | Conventional UT & Phased Array UT (PAUT) Probes |
| Automation Interface | Robotic Arm / Overhead Crane Integration with Machine Vision Guidance |
| Software Platform | Proprietary Real-Time UT Data Acquisition & Analysis Suite |
| Key Software Capabilities | Customizable UI, Zone-Based Defect Classification (Functional vs. Non-Functional Areas), Offline CAD-Based Path Planning, Automated Report Generation, Remote Supervisory Control, MES/ERP System Integration (OPC UA, REST API) |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Supplier Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | N/A |
| Pricing | Available Upon Request |
| Application Domain | Industrial NDT for Complex Geometries |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Product Type | Imported NDT Instrument |
| Model | DGS |
| Portability | Portable |
| Compatible Instruments | OmniScan MX2, OmniScan SX |
| Software Version | MXU v4.4 |
| Supported Probe Series | DGS1, Atlas A24 |
| Calibration Standard | DGS (Distance-Gain-Size) Method |
| Regulatory Compliance | ASTM E2700, ISO 16810, EN 13588, ASME BPVC Section V Article 4 |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Custom-Configured Dual-Arm UT System |
| Pricing | Upon Request |
| Application Domain | Composite Structural Integrity Assessment |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EP650 Integrated Robotic System |
| Pricing | Upon Request |
| Application Scope | Industrial NDT, Aerospace, Power Generation, Petrochemical, and Heavy Manufacturing |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 600 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN12668-1 |
| Weight | 1.68 kg |
| Display | Full VGA (640 × 480), Transflective LCD |
| PRF | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Pulse Width | 25–5000 ns (adjustable via PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 8 standard settings |
| Battery Life | ≥12 h (Li-ion) |
| IP Rating | IP66 (rotary encoder config) / IP67 (keypad config) |
| Operating Temperature | –10 °C to +50 °C |
| Data Storage | 50,000 onboard IDs + 2 GB microSD card |
| Interface | USB OTG, RS-232, VGA output, optional analog output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 650 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasound |
| Compliance | EN 12668-1:2010 |
| IP Rating | IP66 (rotary knob), IP67 (keypad) |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 1.6 kg (with Li-ion battery) |
| Display | Full VGA (640 × 480) transflective color LCD |
| Battery Life | >15 hours |
| PRF | 10–2000 Hz |
| Pulse Energy | 100–400 V |
| Pulse Width | 25 ns–5000 ns (PerfectSquare™) |
| Receiver Bandwidth | 0.2–26.5 MHz |
| Digital Filters | 30 standard, including 7 EN-compliant |
| Gain Range | 0–110 dB |
| Dynamic Range | 110 dB (DAC) |
| A-Scan Memory | 100,000 encoded records |
| Storage | Standard 2 GB microSD card |
| Interfaces | USB OTG, VGA, RS-232, analog output (optional), digital I/O, encoder input |
| Probe Connectors | Two BNC or LEMO No.1 |
| Certifications | MIL-STD-810F (shock/vibration/explosion-proof), NFPA 70 Class I, Div. 2, Group D |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LS |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Compliance Standard | NB/T 47013.3–2015 |
| IP Rating | IP65/IP67 |
| Operating Temperature | –10 °C to 50 °C |
| Weight | 890 g (with Li-ion battery) |
| Display | Full VGA (640 × 480), Transflective Color LCD |
| Battery Life | Up to 6 hours |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | Up to 400 V |
| Receiver Bandwidth | DC–26.5 MHz (–3 dB) |
| Digital Filters | 8 preset configurations |
| Gate Count | 2 independent measurement gates |
| DAC Points | Up to 50, 110 dB dynamic range |
| Data Storage | 100,000 waveforms with ID tags |
| Interface | Dual USB (Host + Client), Digital Video Output |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | EPOCH 6LT |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Compliance | EN 12668-1:2010 |
| Environmental Rating | IP65/IP67 |
| Weight | 890 g |
| Display | Full VGA (640 × 480) Transflective Color LCD |
| Battery Life | Up to 6 hours |
| Operating Temperature | –10 °C to 50 °C |
| PRF Range | 10–2000 Hz |
| Pulse Voltage | 100–400 V |
| Receiver Bandwidth | DC–26.5 MHz (standard), 0.2–26.5 MHz (EN-compliant) |
| Digital Filters | 8 standard settings |
| Data Storage | 100,000 IDs |
| Connectivity | USB 1.1 host, USB 2.0 client, optional Wi-Fi module |
| Software Compatibility | GageView Pro, Olympus Scientific Cloud |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | FOCUS PX / PC / SDK |
| Phased Array Channels | 16:64PR, 16:128PR, 32:128PR |
| Conventional UT Channels | 4 dedicated |
| Max Simultaneous Units | 4 |
| Data Throughput | up to 60 MB/s (4 units) |
| A-scan Rate | up to 20,000 @ 12-bit resolution (750 points/A-scan) |
| Pulse Voltage Range | PA: 4–115 V |
| UT | 50–190 V |
| Gain | PA: 80 dB (46 dB analog + 34 dB digital) |
| UT | 120 dB digital |
| Pulse Width | PA: 30–500 ns (2.5 ns step) |
| UT | 30–1000 ns (2.5 ns step) |
| Bandwidth (−3 dB) | PA: 0.6–17.8 MHz |
| UT | 0.25–28 MHz |
| Beam Count | up to 1024 |
| PRF | 1 Hz–20 kHz |
| Real-time Averaging | PA: 1–16 |
| UT | 1–64 |
| Gate Count | 4 detection + 1 encoder sync |
| Enclosure Rating | IP65 |
| Operating Temperature | up to 40 °C |
| Dimensions (with housing) | 30.7 × 13.5 × 23.6 cm |
| Weight (with housing) | 4.8 kg |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | FocusPX32128PR |
| Pricing | Upon Request |
| Application Domain | Non-Destructive Testing of Non-Ferrous Metal Components |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GYZJ-934-1 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBRV-187.5 |
| Type | Combined Brinell, Rockwell & Vickers Hardness Tester |
| Drive | Motorized Load Application |
| Compliance | ASTM E10, ASTM E18, ASTM E92, ISO 6506, ISO 6508, ISO 6507 |
| Application Scope | Ferrous & Non-ferrous Metals, Heat-Treated Surfaces, Thin Hardened Sheets, Cast Iron, Carbides, Annealed & Tempered Steels |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBS-3000 |
| Hardness Scale | HBW (Brinell, tungsten carbide ball indenter) |
| Test Force Range | 187.5 kgf to 3000 kgf (standard Brinell load range per ISO 6506-1) |
| Indenter | 10 mm hardened steel or tungsten carbide ball |
| Optical Measurement System | High-magnification eyepiece with calibrated scale or digital image capture (optional) |
| Display | Large LCD screen with real-time test parameter and result visualization |
| Data Output | RS-232 or USB interface for printer or PC connectivity |
| Compliance | Designed to meet ISO 6506-1, ASTM E10, and JIS Z 2243 requirements |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Custom-Configurable C-Scan Platform |
| Pricing | Upon Request |
| Application Domain | Industrial NDT of Metallic Bars and Tubes |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEEB140 |
| Hardness Scales | HL, HB, HRB, HRC, HV, HS |
| Display | Full Chinese LCD Menu Interface |
| Printer | Built-in High-Speed Thermal Printer |
| Environmental Rating | Vibration-Resistant, Shock-Resistant, EMI-Immune |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 16859, ASTM A956 (Leeb Method) |
| Data Traceability | On-device Printout with Timestamp & Sample ID Support |
| Power Supply | Rechargeable Li-ion Battery |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Leeb810A |
| Type | Shore A Hardness Tester |
| Display | Digital LCD |
| Application Scope | Rigid Plastics, Hard Rubbers, Coatings, and Polymer-Based Industrial Materials |
| Compliance | ASTM D2240, ISO 7619-1, ISO 868 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Magna-Mike 8600 |
| Measurement Principle | Magnetic Induction (Hall Effect) |
| Max Thickness Range | 25.4 mm |
| Display | Full-color VGA (640 × 480) LCD |
| Data Output | USB 2.0, RS-232, VGA |
| Environmental Rating | IP67 |
| Drop/Shock/Vibration Compliance | MIL-STD-810G |
| Battery Life | Up to 16 h (Li-ion) |
| Operating Temperature | –10 °C to 50 °C |
| Resolution | 0.0001 in (0.001 mm) |
| Probe Options | Straight (86PR-1), Right-Angle (86PR-2) |
| Wear Cap Types | Standard, Chisel, Enhanced |
| Target Options | 6 steel balls (1.58–6.35 mm), 2 discs, 1 steel wire (1.14 mm Ø) |
| Data Logger | File-based alphanumeric recorder with .txt/.csv export to MicroSD |
| Software Interface | WINXL for Excel/SPC integration |
| Calibration Modes | Single-point, multi-point, stored calibration recall |
| Reporting | Onboard report generation, statistical strip chart view |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | MHVSX-50 |
| Loading Method | Electromechanical Closed-Loop Force Control |
| Indentation Measurement | Dual-axis Encoder-equipped Eyepiece (D1/D2) |
| Display | 7-inch High-Sensitivity Touchscreen GUI |
| Optical System | High-Resolution Metallurgical Objective Lens with 10-Step Adjustable LED Illumination |
| Data Output | USB Export to Excel (.xlsx) |
| Hardness Conversion | Vickers (HV), Brinell (HB), Rockwell (HRB/HRC) |
| Compliance | ASTM E92, ISO 6507-1, JIS Z 2244 |
| Automation | Fully Automated Turret Positioning, Motorized Indenter/Objective Switching, Auto-Focus Optional |
| Software Interface | PC Communication via Optional RS-232/USB Protocol with Audit Trail Support |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | NORTEC 600 |
| Design | Portable |
| Frequency Range | 10 Hz to 12 MHz (standard operation at 60 kHz or 480 kHz for conductivity/coating applications) |
| Display | 5.7-inch VGA (640 × 480), color transflective LCD |
| IP Rating | IP66 |
| Operating Temperature | –10 °C to +50 °C |
| Battery Life | Up to 10 hours (standard mode), 6–8 hours (with rotary scanner) |
| Weight | 1.6 kg (with integrated wrist strap) |
| Compliance | EN 15548, CE, FCC, IC, RoHS, RCM, WEEE |
| Data Storage | 500 files (programs + data) |
| Interface | Dual probe ports — 16-pin LEMO (PowerLink-enabled) and BNC (auto-balancing) |
| Software | NORTEC PC (USB 2.0 connectivity, PDF report export, full-file preview, audit-ready file management) |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Custom-Integrated OmniScan MX2 Platform |
| Pricing | Upon Request |
| Application Domain | Pressure Vessel NDT, Composite & Thermoplastic Weld Integrity Assessment |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | OmniScan SX |
| Form Factor | Integrated Single-Channel PA/UT Instrument |
| Phased Array Configuration | 16:64 PR |
| UT Channels | 1 (Pulse-Echo, Pitch-Catch, TOFD) |
| Display | 8.4-inch Capacitive Touchscreen |
| Weight | ~3.2 kg (33% lighter than OmniScan MX2) |
| Dimensions | 270 × 195 × 105 mm (50% smaller volume than MX2) |
| Compliance | ASTM E2700, ISO 16810, ISO 2400, EN 12668-1, ASME BPVC Section V, API RP 2X, AWS D1.1/D1.5 |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | OmniScan X3 |
| Detection Principle | Phased Array Ultrasonics (PAUT), Total Focusing Method (TFM), Time-of-Flight Diffraction (TOFD) |
| Maximum Aperture Support | 128 elements (64-element PA probe + synthetic aperture for TFM) |
| Pulse Repetition Frequency (PRF) | Up to 3× higher than OmniScan MX2 |
| Dynamic Range | 800 dB (A-scan amplitude range) |
| Probe Compatibility | Dual-element linear and matrix arrays, encoded PA and TOFD probes |
| Software Platform | OmniPC-compatible, supports ASTM E2700, ISO 13588, EN 12668-1/3, ASME BPVC Section V Article 4 & 5 compliance workflows |
| Data Management | Onboard acquisition with full A/SA/B/C-scan export, GLP/GMP-compliant audit trail (via optional software license), FDA 21 CFR Part 11 ready |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PAUT-TOFD-CONE-S6 |
| Quotation | Available Upon Request |
| Application Domain | Aerospace Composite Structures, Hybrid Metal-Fiber Joints |
| Brand | Olympus |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Custom PAUT Retrofit Kit |
| Pricing | Available Upon Request |
| Application Domain | Railway Rolling Stock Maintenance & Manufacturing |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-150 |
| Type | Portable Shear-Pin Operated Brinell Hardness Tester |
| Force Application | Mechanical Screw-Driven & Hammer-Impact Dual Mode |
| Hardness Scale | HBW (Brinell Hardness Number, tungsten carbide ball indenter) |
| Indentation Measurement | Optical Readout via Integrated Eyepiece Microscope |
| Compliance | Designed per ISO 6506-1, ASTM E10, and JIS Z 2243 standards |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-750 |
| Applicable Standard | ASTM E110, GB/T 4285 |
| Test Force | 750 kgf (fixed) |
| Force Application Method | Manual lever-driven hydraulic system with pressure-relief control valve |
| Indentation Hold Equivalent | 10–15 s via 3–4 repeated pressure peaks to 750 kgf |
| Mounting Method | Permanent magnet base for ferromagnetic substrates |
| Brand | Olympus |
|---|---|
| Origin | Canada |
| Model | QMNISX-PA1664PR |
| Portability | Portable |
| Primary Application Domain | Aerospace |
| Regulatory Origin | Imported Instrument |
| Distribution Status | Authorized Distributor |