Physical Property Testing Instruments
Filter
Showing 3211–3240 of 12188 results
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HD-E708 Rapid Temperature Change Chamber |
| Temperature Range | −70 °C to +150 °C |
| Refrigeration Method | Compressor-based |
| Explosion-Proof | Standard (Non-Explosion-Proof) |
| Temperature Fluctuation | ≤ ±0.5 °C (unloaded) |
| Temperature Deviation | ≤ 2 °C (unloaded) |
| Temperature Uniformity | ≤ 2 °C (unloaded, 15-point measurement) |
| Heating Rate | ≥ 3 °C/min (average, unloaded) |
| Cooling Rate | ≥ 10 °C/min (70 °C → −10 °C, average, unloaded, at outlet) |
| Internal Chamber Dimensions | 1700 × 1700 × 2500 mm (W × D × H) |
| Chamber Volume | 7 m³ |
| Airflow Capacity | ≥ 17,500 CFM |
| Maximum Thermal Load | 500 kg aluminum mass (13 kW heat dissipation) |
| Floor Load Capacity | ≥ 1000 kg/m² (uniformly distributed) |
| Insulation | ≥ 100 mm rigid polyurethane foam |
| Interior Material | SUS#304 stainless steel (≥1.0 mm thickness) |
| Exterior Material | SUS#304 stainless steel or galvanized steel with dual-side paint (≥1.0 mm thickness) |
| Temperature Overshoot | ≤ 5 °C (15-point measurement) |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HD-E804-45 |
| Heating Method | Electric Forced-Air with Vacuum Capability |
| Chamber Dimensions (W×D×H) | 300 × 300 × 276 mm |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | Cold-Rolled Steel with Powder-Coated Finish |
| Temperature Range | Ambient +10°C to 250°C |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±1°C |
| Vacuum Level | ≤133 Pa (mechanical vacuum gauge) |
| Power Supply | AC 220 V, 50 Hz |
| Input Power | 2100 W |
| Working Environment | 5–40°C |
| Standard Compliance | JB/T 5520–1991, JB/T 20033–2004, JB/T 9505–1999 |
| Accessories | 2 adjustable stainless steel shelves, silicone door gasket, PID digital temperature controller with data logging interface |
| Brand | Haida International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HD-E805 Muffle Furnace / Ashing Furnace |
| Power | 2.5 kW (HD-E805), up to 12 kW (HD-E805-5) |
| Max Temperature | 1000 °C (standard), 1200 °C (high-temp variants) |
| Internal Chamber Dimensions (H×W×D) | 80×120×200 mm (HD-E805), up to 200×300×500 mm (HD-E805-5) |
| Voltage | 220 V or 380 V AC, 50/60 Hz |
| Controller Options | C6, C6D, or S27 programmable process controllers |
| Construction | Stainless steel outer casing with ceramic fiber insulation (vacuum-formed modules), refractory lining, rear ventilation ports for optional catalytic exhaust or forced-air cooling |
| Safety | Ground-fault circuit interrupter (GFCI) integrated, viewing window in door |
| Brand | HAIDA International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | HD-E808-90AT |
| Spray Mode | Adjustable Continuous/Cyclic/Programmable |
| Salt Spray Deposition Rate | 1.0–2.0 mL/h/80 cm² (averaged over ≥16 h) |
| Nozzle Pressure | 1.00 ± 0.01 kgf/cm² |
| Test Chamber Temperature Range | RT to 70 °C |
| Saturated Air Tank Temperature Range | RT+5 °C to 70 °C |
| Humidity Range | 30–98 %RH |
| Internal Dimensions (W×D×H) | 900 × 600 × 600 mm |
| Nominal Volume | 324 L |
| Power Supply | 3-phase AC 380 V, 10 kW |
| Safety Protections | Overtemperature, Low-Water, Phase-Loss, Ground-Fault |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-U801 Bridge-Type Automated 2.5D Vision Measuring System |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HAIDA Leather Colorfastness Tester |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HAIDA Leather Flexing Tester |
| Pricing | Available Upon Request |
| Brand | HAIDA International |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA Shoe Sole Adhesion Tester |
| Pricing | Upon Request |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HAIDA UV Sterilization Chamber |
| Pricing | Available Upon Request |
| Brand | Haiyin Equipment |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | COK7193 |
| Price Range | USD 12,000 – 39,500 (FOB) |
| High-Temperature Range | +180 °C |
| Low-Temperature Range | −70 °C |
| Thermal Shock Range | −55 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Temperature Transition Time | ≤5–15 s (−55 °C ↔ +150 °C) |
| Brand | Haiyin Equipment |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HW-100L |
| Temperature Range | −70 °C to +150 °C |
| Cooling Method | Compressor-Based Refrigeration |
| Explosion-Proof Design | Standard (Non-Explosion-Proof) |
| Temperature Fluctuation | ±2.0 °C |
| Temperature Deviation | ±1.5 °C |
| Temperature Uniformity | 2.0 °C |
| Heating Rate | 3–5 °C/min |
| Cooling Rate | 1.0–1.2 °C/min |
| Internal Chamber Dimensions | 30 × 25 × 30 cm (L × W × H) |
| Brand | Haiyin Equipment |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromagnetic Vibration Shaker |
| Rated Thrust | 22 kN |
| Frequency Range | 0.5–600 Hz |
| Maximum Load Capacity | 100 kg |
| Tabletop Dimensions | 500 × 500 × 550 mm |
| Acceleration Range | 0–22 g |
| Brand | Haiyin Equipment |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromagnetic Vibration Shaker |
| Model | HY-0428Z |
| Rated Thrust | 22 kN |
| Frequency Range | 0.5–600 Hz |
| Max. Test Load | 100 kg |
| Tabletop Dimensions | 500 × 500 × 550 mm |
| Acceleration Range | 0–22 g |
| Control Modes | Fixed-frequency, Sweep, Logarithmic, 1-octave/decade, Random PSD, Sine Broadband, Programmable Sequencing |
| Compliance Standards | ISO 2247, ISO 13355, IEC 60068, ASTM D999/D4728/D3580, GB/T 4857, GB/T 2423 |
| Brand | Haiyin Equipment |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromagnetic Vibration Shaker |
| Rated Thrust | 22 kN |
| Frequency Range | 0.5–600 Hz |
| Maximum Test Load | 100 kg |
| Table Dimensions | 500 × 500 × 550 mm (W × D × H) |
| Acceleration Range | 0–22 g (load-dependent) |
| Waveform Modes | Sine, Random, Swept Sine, Programmable, Octave, Logarithmic, Fixed-Amplitude/Fixed-Acceleration |
| Vibration Axes | Independent or simultaneous X/Y/Z (6-DOF capable) |
| Table Material | Anodized Aluminum with 28 × M10 threaded mounting holes, 24 × strap-through slots, 4 × fixture-mounting M5 holes |
| Magnetic Leakage Reduction | Integrated 30 cm perimeter magnetic shunt (reduces stray flux by 50–70%) |
| Displacement Range | 0–5.0 mm peak-to-peak (load-dependent) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SFT-A3 |
| Pricing | Available Upon Request |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Data Acquisition Rate | Up to 23 Hz |
| Zeroing | One-Touch Automatic Calibration |
| Operating System | 7-inch Full-Color WinCE Embedded Interface |
| Data Export | USB 2.0 Flash Drive Support |
| Peripheral Compatibility | External Mouse Supported |
| Stage Vertical Travel | 0–50 mm |
| Stage Repeatability | ±0.5 µm |
| Stage Speed Control | Programmable & Variable During Test |
| Actuation Interface | USB-Controlled Precision Lead Screw (Low-Noise, High-Stability) |
| Temperature Sensing Accuracy | ±0.01 °C |
| Temperature Readout | Software-Integrated, Independent Display |
| Test Methods | Wilhelmy Plate Method, du Noüy Ring Method |
| Automation Level | Fully Automated Surface/Interfacial Tension Measurement with Manual Override Mode |
| Liquid Level Detection | Real-Time Electronic Sensor-Based Meniscus Recognition |
| Data Management | On-Screen Real-Time Plotting, Local Database Storage, Historical Query, Export to Origin-Compatible Format (.opj/.txt) |
| Dimensions (L×W×H) | 450 × 350 × 580 mm |
| Weight | 20 kg |
| Power Supply | 220 V AC, 3 A |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | C7942CA-22 |
| Pixel Array | 2400 × 2400 |
| Pixel Size | 50 µm × 50 µm |
| Active Area | 120 mm × 120 mm |
| Scintillator | CsI (Thallium-doped) |
| Bit Depth | 12-bit digital output |
| Frame Rate | 2 fps (full resolution), 9 fps (4×4 binning) |
| Dynamic Range | 2000:1 (typical) |
| X-ray Resolution | 8 lp/mm (typical, at 25 °C) |
| Output Interface | RS-422 |
| Noise Performance | Low-noise architecture with high signal-to-noise ratio (SNR) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | S8658-01 / S8658-01F |
| Frame Rate (typ.) | 15 fps |
| Active Image Area (per chip) | 73.728 mm × 6.144 mm |
| Pixel Pitch | 48 µm |
| Total Pixels | 4608 × 128 (3 × 1536 × 128) |
| Pixel Size | 48 µm × 48 µm |
| Fill Factor | 100% |
| Scintillator | CsI(Tl) + Fiber Optic Plate (FOP) (S8658-01) / FOP only, no scintillator (S8658-01F) |
| Package | Ceramic |
| TDI Mode | Supported |
| Dynamic Range | Wide |
| Dark Current | Low |
| Operation Mode | MPP (Multi-Pinned Phase) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI 8751 / HI 8757 |
| Temperature Range (HI 8751) | –40.0 to +150.0 °C |
| Temperature Range (HI 8757) | –50.0 to +199.0 °C and +200 to +1350 °C |
| Sensor Type | HI 8751 — Precision Silicon RTD Probe (HI765PW) |
| Accuracy (HI 8751) | ±0.2 °C (–10.0 to +80.0 °C) |
| Accuracy (HI 8757) | ±1.0 °C or ±0.75% of reading (whichever is greater) |
| Resolution | 0.1 °C (–50.0 to +999.9 °C), 1 °C above 1000 °C |
| Power | 9 V alkaline battery (included) |
| Housing | ABS plastic (HI 8751), IP65-rated ABS with stainless steel probe (HI 8757) |
| Compliance | CE, RoHS, EN 61326-1 (EMC for laboratory equipment) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI9060 |
| Instrument Type | Portable Temperature Meter |
| Enclosure Rating | IP67 (waterproof) |
| Power Supply | 4 × 1.5 V AA batteries |
| Probe Interface | Standard BNC or mini-DIN (model-dependent) |
| Memory Capacity | Up to 100 data points |
| Operating Temperature Range | 0 to 50 °C |
| Storage Temperature Range | -20 to 70 °C |
| Relative Humidity Limit | Up to 95 % RH non-condensing |
| Calibration Points | Single-point or multi-point via calibration standards (e.g., HI765-18C, HI765000C, HI765070C) |
| Probe Compatibility | HI765BL (1 m thermistor probe), HI765L/10 (10 m thermistor probe), HI766C (penetration thermocouple probe), HI2602 carrying case |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI 146-00 / HI 151-00 |
| Instrument Type | Wall-Mounted Digital Thermohygrometer |
| Probe Type | Stainless Steel Needle Probe (HI 146-00) |
| Display | LCD |
| Power | 1 × 1.5 V AAA battery |
| Calibration Verification | Built-in self-test mode (READ/TEST switch) |
| Compliance | Designed for HACCP, ISO 22000, and FDA Food Code-compliant environments |
| Sample Contact | Air, gases, liquids, semi-solids, frozen foods |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP360 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.3 °C |
| Capillary Dimensions | ID 0.9–1.1 mm, Wall Thickness 0.10–0.15 mm (optional 1.6 mm OD) |
| Sample Capacity | 3 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal |
| Video Storage | ~10,000 minutes (H.264 encoded) |
| Compliance | FDA 21 CFR Part 11, ASTM D3104, GB/T 24892–2010, GB/T 12766–2008, SN/T 0801.5–1999 |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Calibration | Multi-point temperature calibration |
| User Management | Role-based access control with audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP420 |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Data Storage | 16 GB internal (expandable via USB) |
| Compliance | FDA 21 CFR Part 11 (audit trail, user permission tiers, password policy, electronic signature support) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP430 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Camera | 720p HD, 8× optical zoom |
| Display | 8-inch capacitive TFT touchscreen running Android OS |
| Data Storage | Up to 128 GB (supports USB backup/restore) |
| Connectivity | Wi-Fi, USB ×3, RS-232, RJ45 |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready user management & electronic signature support |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP450 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 128 GB internal (≥40,000 min video archive) |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Cooling | Ambient to 50 °C in ≤7 min |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP470 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | ID 1.0 mm × OD 1.4 mm |
| Sample Capacity | 4 samples per run |
| Dual TFT Color Displays | 5.6″ + 3.5″ |
| Video Magnification | 7× |
| Data Storage | Up to 1000 test records, 16 GB SD card support |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, user-level access control), GLP-ready architecture |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP470 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Data Storage | Up to 128 GB (≥40,000 min video archive) |
| Connectivity | USB ×3, RS232, Wi-Fi, RJ45 |
| Video | 720p, 8× optical zoom, real-time watermarking (timestamp + temperature), synchronized thermal profile playback |
| Calibration | Up to 6-point certified reference material calibration |
| Compliance | FDA 21 CFR Part 11 audit trail, user role-based access control (Admin/Supervisor/Operator/IT), password aging & complexity policies, screen lock timeout |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | MP490 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.01 °C |
| Data Storage | 128 GB internal (≥40,000 min video capacity) |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Brand | HPM HANSA PRESS- und MASCHINENBAU GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VKA 110 |
| Price Range | USD 13,500 – 68,000 |
| Instrument Type | Four-Ball Friction and Wear Tester |
| Maximum Friction Load | 12,000 N |
| Friction Force Resolution | 0.1 N |
| Maximum Test Temperature | 150 °C |
| Rotational Speed Range | 10–5800 rpm |
| Loading Method | Dead-weight (mass-based) |
| Temperature Range | −30 to +150 °C |
| Contact Geometry | Point contact (ball-on-ball) |
| Measured Parameters | Friction torque, specimen temperature, transition resistance, rotational cap diameter |
| Compliance Standards | DIN 51350-1 to -6, VW PV 1444, VW PV 1454, ASTM D2783, D2266, D4172, IP 239/85 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | DC-1006N |
| Temperature Range | −10 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Circulation Flow Rate | 6 L/min |
| Bath Opening Diameter | φ90 mm |
| External Dimensions (L×W×H) | 610×370×460 mm |
| Circulation Type | Internal Only |
| Construction | Stainless Steel Interior and Work Surface |
| Control System | Microprocessor-Based PID with Digital Display and Setpoint Programming |
| Refrigeration | Hermetically Sealed Compressor with Overheat and Overcurrent Protection |