Physical Property Testing Instruments
Filter
Showing 4411–4440 of 4488 results
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | DKN313C |
| Instrument Type | Benchtop |
| Temperature Range | Ambient +10°C to 260°C |
| Temperature Uniformity | ±1.0°C (at setpoint) |
| Temperature Fluctuation | ±0.5°C |
| Heating Rate | ~60 min (from ambient to 210°C) |
| Chamber Volume | 27 L |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (Reference Only) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98% RH (optional: 5–98% RH) |
| Rapid TC Range | −45 °C to +85 °C or −20 °C to +85 °C |
| Ramp Rates | 5–25 °C/min (customizable) |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0% RH (at ≥75% RH) |
| Humidity Stability | ±2.5% RH |
| Interior Material | SUS#304 Stainless Steel |
| Refrigeration System | Hermetic Dual-Stage Compressor with Eco-Friendly Refrigerants (R404A/R23) |
| Controller | Touchscreen LCD with English/Chinese Interface |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CST-50 |
| Projection Screen Size | 200 × 200 mm (graduated scale etched on optical glass) |
| Stage Dimensions | Square stage 110 × 125 mm |
| Stage Travel | Longitudinal ±10 mm, Transverse ±10 mm, Vertical ±12 mm |
| Stage Rotation | 0–360° continuous |
| Total Optical Magnification | 50× (Objective: 2.5×, Projection Lens: 20×) |
| Illumination Source | 12 V / 100 W halogen tungsten lamp |
| Power Supply | 220 V AC, 50 Hz |
| Overall Dimensions | 515 × 224 × 603 mm |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.185 |
| Max. Load | 50 N (dead-weight type) |
| Temperature Range | Up to 200 °C |
| Parallel Plate Diameter | φ40 mm (optional: UL-compliant φ3/4″ or φ3/8″) |
| Thickness Displacement Measurement | Analog dial indicator (0.01 mm resolution, 10 mm max travel) |
| Specimen Support Configurations | 1-, 3-, or 5-station modular frame |
| Included Accessory | Radius R5 mm metal mandrel |
| Power Supply | AC 200 V, single-phase, 15–30 A, 50/60 Hz |
| Dimensions & Weight | 1-station: ~780 × 825 × 1800 mm (W×D×H), ~142 kg |
| 3-station | ~1250 × 1120 × 1800 mm, ~286 kg (benchtop height option: H = 952 mm) |
| Brand | YDWO (Yidian Woguang) |
|---|---|
| Model | WBL Series |
| Measurement Principle | Static Volumetric Nitrogen Physisorption at 77 K |
| Adsorption Gas | High-Purity N₂ (99.999%), optional He |
| P/P₀ Range | 1×10⁻⁶ to 0.998 |
| Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Size Analysis Range | 0.35–500 nm (3.5–5000 Å) |
| Pressure Sensors | 3–6 × high-accuracy absolute transducers (0–133 kPa, ±0.12% FS) |
| Temperature Sensor | PT-100 (±0.1 °C) |
| Cryostat | 2 L metal Dewar, >80 h hold time |
| Ultimate Vacuum | ≤1.0×10⁻⁴ Torr |
| Vacuum Pump | Imported dual-stage rotary vane pump |
| Sample Capacity | 1–3 stations (model-dependent) |
| Compliance | ISO 9277, ISO 15901, GB/T 119587 |
| Software | Integrated analysis suite for BET, Langmuir, BJH, t-plot, D-A, H-K, NLDFT, GCMC, and true density calculation |
| Output | Printable reports & Excel export (isotherms, surface area, pore volume/area distribution, cumulative metrics) |
| Brand | YDWO (Shanghai Instrumentation & Physical Optics) |
|---|---|
| Origin | Shanghai, China |
| Model | WJL-612 / WJL-616 / WJL-618 / WJL-622 / WJL-626 / WJL-628 |
| Measurement Range | 0.02–2000 µm (wet), 0.1–2000 µm (dry) |
| Repeatability | ≤ ±0.5% (D50, NIST-traceable standard reference materials) |
| Analysis Time | <60 s per sample |
| Dispersion Methods | Dry dispersion via pneumatic jet disperser |
| Compliance | ISO 13320:2020 (Laser diffraction methods for particle size analysis) |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (main unit) | 1000 × 330 × 300 mm |
| Weight | 40–50 kg |
| Brand | Yi Heng (Shanghai Yi Heng) |
|---|---|
| Origin | Shanghai, China |
| Model | BPH Series / BPHJ Series |
| Temperature Range | −20 °C to 130 °C (A), −40 °C to 130 °C (B), −60 °C to 130 °C (C) |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Refrigerant | R134a (non-ozone-depleting) |
| Internal Chamber Material | AISI 304 mirror-finish stainless steel |
| Control System | Microprocessor-based digital controller (BPH) or 7-inch color TFT touchscreen with programmable logic (BPHJ) |
| Programmability | Up to 120 programs × 99 segments × 999 cycles |
| Communication Interface | RS-232 / RS-485 standard |
| Safety Protections | Independent over-temperature cut-off, compressor overheat/overcurrent/overload protection, fan overheat protection, dual-stage temperature deviation alarms |
| Brand | YiHeng (Shanghai Yi Heng) |
|---|---|
| Origin | Shanghai, China |
| Model | BPHJS Series |
| Temperature Range | −60 °C to +130 °C |
| Humidity Range | 30–95 %RH |
| Temperature Uniformity | ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Fluctuation | ±3 %RH |
| Refrigerant | R134a (ozone-friendly) |
| Inner Chamber Material | AISI 304 mirror-finish stainless steel |
| Control System | Color TFT touchscreen with programmable logic (120 programs × 99 segments, up to 999 cycles) |
| Communication Interface | RS-232/RS-485, USB data export (SD card), optional 485 printer interface |
| Safety Protections | Independent over-temperature cutoff, compressor overheat/overcurrent/overload protection, fan overheat protection, low-water alarm |
| Power Supply | AC 380 V, 50 Hz (models with −40 °C or −60 °C capability) |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | LHS Series |
| Price Range | USD 3,300 – 10,500 (FOB Shanghai) |
| Instrument Type | Vertical Chamber |
| Temperature Range | Type I: −5 to 80°C |
| Type II | −10 to 70°C |
| Humidity Range | Type I: 40–85% RH |
| Type II | 40–95% RH |
| Temperature Uniformity | ±0.5°C (high-temp), ±1.0°C (low-temp) |
| Humidity Deviation | ±3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Internal Chamber Dimensions | See Technical Datasheet |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-371 |
| Detection Method | Automated Eddy Current Inspection |
| Form Factor | Benchtop |
| Frequency Range | 50 Hz – 10 MHz |
| Gain Adjustment | 0 dB – 99 dB (continuous) |
| Phase Rotation | 0° – 359° (continuous) |
| X/Y Gain Ratio | 0.1 – 10.0 |
| Phase Amplification Factor | 1 – 10 (patented) |
| Probe Drive Level | 1 – 8 (adjustable) |
| Probe Matching Level | 0 – 3 (adjustable) |
| Maximum Scan Speed | 10 m/s |
| Operating Temperature | −10 °C to +50 °C |
| Probe Operating Temperature | −20 °C to +50 °C |
| Enclosure | Sealed plastic housing with protective rubber boot |
| Weight (with battery) | 2.3 kg |
| Battery Runtime | Up to 6 hours |
| Charging Time | 2–4 hours (on-screen status indicator) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Power Consumption | 20 W |
| Dimensions | 240 mm × 150 mm × 70 mm |
| Data Management | Auto-save and auto-replay of inspection records |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-41 |
| Detection Method | Fully Automated Eddy Current Inspection |
| Eddy Current Signal Type | Multi-Frequency (Quad-Frequency) |
| Instrument Form Factor | Benchtop |
| Number of Channels | 4 |
| Maximum Inspection Speed | >200 m/min |
| Frequency Range | 50 Hz to 10 MHz (continuously adjustable) |
| Gain Range | 0–99.0 dB (continuously adjustable, 0.1 dB step) |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-66S |
| Detection Mode | Automated In-Line Inspection |
| Form Factor | Benchtop |
| Frequency Range | 50 Hz – 10 MHz |
| Gain Adjustment | 0–99 dB (wide-range, continuous) |
| Phase Rotation | 0°–359° (continuous) |
| X/Y Gain Ratio | 0.1–10.0 |
| Phase Amplification Factor | 1–10 (patented) |
| Probe Drive Level | 1–8 (adjustable) |
| Probe Matching Level | 0–3 (adjustable) |
| Maximum Scan Speed | 10 m/s |
| Operating Temperature (Probe) | −20 °C to +50 °C |
| Operating Temperature (Instrument) | −10 °C to +50 °C |
| Enclosure | Sealed Plastic Housing with Protective Sleeve |
| Weight (with battery) | 2.3 kg |
| Battery Runtime | Up to 6 hours |
| Charging Time | 2–4 hours (on-screen status indicator) |
| Power Supply | Universal AC 100–240 V, 50–60 Hz |
| Power Consumption | 20 W |
| Dimensions | 240 mm × 150 mm × 70 mm |
| Data Management | Auto-storage & playback capability |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1 µm – 500 µm |
| Reproducibility | < 0.5% RSD |
| Measurement Time | < 60 seconds per analysis (excluding sample dispersion) |
| Dispersion Method | Wet Dispersion |
| Laser Source | 635 nm semiconductor laser (3 mW output, >25,000 h lifetime) |
| Detection Channels | 76 independent photodiode elements |
| Ultrasonic Power | 50 W |
| Stirring Speed | 100–600 rpm (adjustable) |
| Sample Concentration Range | 0.05–1.0% w/v (dependent on particle density, size distribution, and refractive index) |
| Data Acquisition Rate | 2000 scans/sec |
| Interface | RS-232 serial port |
| Operating System Compatibility | Windows 95 or later |
| Power Supply | AC 220 V ±10%, 50/60 Hz, 200 W |
| Environmental Requirements | 5–35 °C ambient temperature, <85% relative humidity |
| Brand | Yoyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GDW-225L(A/B/C) |
| Temperature Range | A: −20 °C to 150 °C |
| B | −40 °C to 150 °C |
| C | −60 °C to 150 °C |
| Humidity Range | 20–98% RH |
| Humidity Deviation | ±3–5% RH |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Resolution | 0.1 °C |
| Heating Method | Nickel-Chromium Alloy Heater |
| Refrigeration System | Hermetic Imported Compressor with Eco-Friendly Refrigerant (R404A/R23) |
| Control System | TEMI PID-Based Intelligent Controller |
| Programmability | 100-Stage Multi-Segment Program |
| Power Supply | AC380V 50Hz |
| Internal Volume | 225 L |
| Internal Dimensions (W×D×H) | 600×500×750 mm |
| External Dimensions (W×D×H) | 1115×1085×1885 mm |
| Standard Accessories | 2 Fixed + 10 Adjustable 304 Stainless Steel Shelves, Left-Side Test Port, Triple-Layer Insulated Observation Window with Defrosting & Illumination, Silicone Door Seal, RS485/USB Interface (Optional) |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YP-3711 |
| Detection Method | Automatic Eddy Current Testing |
| Eddy Current Signal Type | Multi-Frequency |
| Instrument Form Factor | Benchtop |
| Number of Channels | 1–16 |
| Maximum Inspection Speed | >200 m/min |
| Frequency Selection Options | 1–4 independent frequencies |
| Gain Range | 0–90 dB (0.5 dB step) |
| Frequency Range | 50 Hz – 10 MHz |
| Phase Rotation | 0–360° (1° step) |
| High-Pass Filter | Off or 1–2 kHz |
| Low-Pass Filter | Off or 1–2 kHz |
| Digital Filter Points | 1–10 |
| End-Delay/Start-Delay | 0–65 s |
| Marking Delay Time | 0–120 s |
| Fixed-Length Marking Distance | 0–5 m |
| Clock Mode | Internal or External |
| Probe Excitation Amplitude | 1–8 (arbitrary units) |
| Hardware Alarm Outputs | 8 channels |
| Probe Impedance Matching | 0–3 (digital tuning steps) |
| Input Signal Types | TTL-level switch signals (alarm, A-scan trigger, encoder pulse) |
| Display Modes | Dot, Line, Blank, Crosshair Cursor |
| Dimensions | 459.8 × 442 × 179 mm (standard) / 459.8 × 442 × 220.7 mm (with extended module) |
| Brand | YSEI |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SHH-XXW-SD Series |
| Price Range | USD 28,000 – 70,000 (FOB) |
| Internal Dimensions (D×W×H) | Customizable per client specification |
| Temperature Range | 20–50 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Rate | 0.5 °C/min (customizable) |
| Humidity Range | 50–90 % RH |
| Humidity Uniformity | ±3 % RH |
| Power Supply | 220 V / 50 Hz |
| Data Storage | 64 MB internal cyclic memory + SD card export + optional real-time PC logging via RS485 |
| Remote Monitoring | Supported via Sims software over LAN/internet (up to 30 units per host) |
| Brand | YSEI |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SHH-XXW-SD Series |
| Price Range | USD 28,000 – 70,000 (FOB) |
| Internal Dimensions (D×W×H) | Custom-engineered per client specification |
| Temperature Range | 20–50 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Rate | 0.5 °C/min (adjustable per configuration) |
| Humidity Range | 50–90 % RH |
| Humidity Uniformity | ±3 % RH |
| Power Supply | 220 V / 50 Hz |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-2231 |
| Temperature Range (High/Low Zones) | +60°C to +200°C / −10°C to −70°C |
| Shock Transition Time (2-tank mode) | ≤5 min (RT to −65°C or RT to +150°C) |
| Temperature Uniformity | ±2.00°C |
| Internal Chamber Material | SUS#304 Stainless Steel |
| Refrigeration System | Dual-stage cascade refrigeration with eco-friendly refrigerant |
| Control System | OYO-8226 PID controller with 320×240 LCD interface |
| Programmable Cycles | Up to 9999 cycles |
| Data Interface | RS-232 with PC software support |
| Power Supply | AC 3φ 380 V, 50 Hz |
| Cooling Method | Water-cooled |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-DL-5000A |
| Short-Circuit Current | 5000 A |
| Enclosure Internal Dimensions | W1000 × H1000 × D1000 mm |
| External Dimensions | Approx. W1180 × H1680 × D1360 mm |
| Enclosure Construction | Integrated steel frame with control console |
| Outer Casing Material | Thickened cold-rolled steel (gray + blue powder coating) |
| Inner Chamber Material | Thickened stainless steel |
| Observation Window | Dual-layer tempered explosion-proof glass (350 × 400 mm) |
| Lighting | LED interior lighting |
| Ventilation | Forced-air exhaust system |
| Pressure Relief | Automatic pressure-relief port |
| Short-Circuit Mechanism | Vacuum arc interruption + high-current DC contactor |
| Contact Resistance | <5 mΩ (standard), configurable up to ≤20 mΩ |
| Mechanical Life | ≥500,000 cycles |
| Ambient Operating Temperature | Room temperature |
| Control Interface | PC-based software platform |
| Data Acquisition Channels | 5-channel synchronized sampling |
| Measured Parameters | Current (0–5000 A), Voltage (0–36 V), Temperature (0–1200 °C) |
| Measurement Accuracy | ±0.5% FS (current/voltage), ±1 °C (temperature) |
| Sampling Rate | ≥30 Hz per channel |
| Resolution | 0.01 A, 0.1 V, 0.1 °C |
| Data Export | CSV, Excel, and secure upload capability (customizable) |
| Optional Features | HD in-chamber video monitoring, integrated fire suppression, smoke extraction, real-time multi-parameter curve overlay (I-V-T-t) |
| Safety Protections | Leakage current detection, overtemperature cutoff, overvoltage/overcurrent shutdown, acoustic-optical alarm |
| Power Supply | AC 220 V / 380 V, 50 Hz |
| Brand | Yuhantest |
|---|---|
| Origin | Shanghai, China |
| Model | YH-FB4B |
| Max Load Capacity | 50 kN |
| Load Accuracy | ±0.5% of full scale |
| Effective Stroke | 800 mm |
| Test Width Range | 370–1000 mm (customizable) |
| Speed Range | 0.001–500 mm/min |
| Torque Measurement Range | 500 N·m |
| Max Torque Output | 5000 N·m |
| Torque Resolution | 1/300,000 full scale |
| Torsion Angle Range | 0–180° |
| Motor Power | 1500 W |
| Drive System | Panasonic servo motor + TBI ball screw |
| Control Interface | Color touchscreen + PC-based software with dual-mode operation |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | YT-321 |
| Price | USD 170 (FOB) |
| Measurement Principle | Pulse-Echo Ultrasonic |
| Range (Steel) | 0.75–350 mm |
| Standard Probe Range | 1–250 mm |
| Resolution | 0.1 mm |
| Sound Velocity Adjustment | 1000–9999 m/s |
| Operating Temp. | −10 to +60 °C |
| Accuracy | ±(1% H + 0.1) mm (H = actual thickness) |
| Power | Two AAA alkaline batteries |
| Battery Life | ~200 hours |
| Dimensions | 130 × 70 × 25 mm |
| Weight | 0.2 kg (instrument only) |
| Display | High-brightness LED backlight |
| Compliance | Designed per ISO 2400:2019 (Ultrasonic thickness measurement — Calibration and verification procedures) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-600A |
| Measurement Range | 2–500 mN/m |
| Accuracy | ±0.4 mN/m |
| Sensitivity | 0.1 mN/m |
| Detection Method | Du Noüy Ring Method |
| Power Supply | AC 220 V ±5%, 50 Hz ±2.5% |
| Power Consumption | 50 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Temperature Control | PID Auto-Tuning |
| Sample Capacity | 3 positions |
| Display | High-Resolution Color Touchscreen |
| Data Output | Auto-printing & Real-time Dynamic Tension Curve Visualization |
| Calibration | Single-Point Calibration Protocol |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-610 |
| Magnetization Modes | AC Circumferential (0–2000 A, continuously adjustable with phase-controlled power-off) |
| Longitudinal Magnetization Force | AC 0–24,000 AT, continuously adjustable with phase-controlled power-off |
| Magnetization Configurations | Circumferential, Longitudinal, or Composite |
| Powder Application Method | Dry Powder |
| Demagnetization Residual Field | ≤0.2 mT |
| Inspection Cycle Time | 6 seconds per component |
| Continuous Operating Duration | >4 hours |
| Structural Design | Hand-Carried Yoke Configuration |
| Primary Application Sector | Rail Transportation Infrastructure |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-610C |
| Magnetization Modes | Circumferential (AC 0–2000 A, phase-controlled cutoff), Longitudinal (AC 0–24,000 AT, phase-controlled cutoff), Composite |
| Configuration | Portable, Handheld Yoke System |
| Magnetization Method | Dry Powder MPI |
| Circumferential Magnetizing Current | AC 0–2000 A, continuously adjustable with phase-angle control for precise demagnetization timing |
| Longitudinal Magnetomotive Force | AC 0–24,000 AT, continuously adjustable with phase-angle control |
| Inspection Cycle Time | ≤6 seconds per component |
| Residual Field After Demagnetization | ≤0.2 mT |
| Continuous Operating Duration | >4 hours |
| Input Voltage | AC 220 V ±10% |
| Output Voltage | AC 36 V (safety-isolated) |
| Output Current | >10 A |
| Lifting Power | ≥5 kg (AC), ≥18 kg (DC for optional probes) |
| Duty Cycle | 50% |
| Sensitivity Verification | Clear indication of ASTM E1444-compliant A1-30/100 shim test piece |
| Dimensions (H×W×D) | 230 × 160 × 120 mm |
| Weight | 5 kg |
| Probe Compatibility | Standard A-type yoke (adjustable pole spacing 0–250 mm), optional E-type (cross-yoke), D-type (high-lift yoke), O-type (circular coil, Φ150 mm, 1800 TA) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-610C |
| Magnetization Modes | Circumferential (AC 0–2000 A, phase-controlled cutoff), Longitudinal (AC 0–24,000 AT, phase-controlled cutoff), Composite |
| Inspection Cycle Time | ≤6 s per part |
| Residual Field After Demagnetization | ≤0.2 mT |
| Continuous Operating Duration | >4 h |
| Input Voltage | AC 220 V ±10% |
| Output Voltage | AC 36 V |
| Output Current | >10 A |
| Lifting Force | ≥5 kgf |
| Duty Cycle | 50% |
| Sensitivity | Clear indication of ASTM E1444/E709 A1-30/100 shims |
| Probe Configurations | Electromagnetic Yoke (adjustable pole spacing: 0–250 mm), Horseshoe Probe (0–160 mm), Circular Coil (Φ150 mm, 1800 TA) |
| Dimensions (L×H×W) | 230×160×120 mm |
| Weight | 5 kg |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | YT-JNY |
| Price | USD 3,650 (approx.) |
| Measurement Range | 20–88 (arbitrary hardness units, calibrated per USP <1049> and Ph. Eur. 2.9.40 compliant soft capsule indentation scale) |
| Load Capacity Options | 50 N, 100 N, 500 N, or 1000 N |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Probe | Cylindrical, Ø10 mm or 10 mm² contact area |
| Upper Platen Parallelism | <0.025 mm |
| Lower Platen Diameter | 120 mm |
| Dimensions (W×D×H) | ~450 × 450 × 650 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | YT-TCD-101 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | 1–80 °C/min |
| Cooling Time | 15 min (from 1000 °C to 100 °C) |
| Balance Capacity | 1 mg–2 g (extendable to 30 g) |
| Balance Resolution | 0.1 µg |
| Isothermal Hold Duration | 0–300 min (user-configurable) |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Data Interface | RS-232 |
| Software | Integrated TGA analysis suite with automated curve recording, baseline correction, derivative (DTG) calculation, kinetic modeling (e.g., Kissinger, Ozawa), and GLP-compliant reporting |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Model | YT-UC750 |
| Measurement Range | 0.15–300 mm (steel) |
| Resolution | 0.001 mm (0.15–100 mm), 0.01 mm (100–300 mm) |
| Display | 128×64 LCD with LED backlight |
| Accuracy | ±0.005 mm (<5 mm), ±0.01 mm (5–20 mm), ±0.1 mm (20–300 mm) |
| Sound Velocity Range | 1000–9999 m/s |
| Operating Temperature | –10°C to +50°C (optional –20°C) |
| Power Supply | 2 × AA 1.5 V alkaline batteries (up to 200 h operation without backlight) |
| Auto-Shutdown | After 5 min inactivity |
| Data Storage | 500 readings |
| Probe Types | Single-crystal (e.g., 15 MHz), dual-element (5 MHz, 7 MHz), optional 4 mm single-crystal, 2 MHz high-penetration, and 7 MHz small-diameter probes |
| Coating-Tolerant Mode | Yes (echo-to-echo & pulse-echo) |
| Calibration Modes | Zero calibration on test block, sound velocity inversion (reverse calibration), single-point calibration |
| Units | mm / inch switchable |
| Alarms & Delta Mode | Configurable |
| Dimensions | 153 × 67 × 26 mm |
| Weight | 220 g |
| Brand | YXLON |
|---|---|
| Origin | Germany |
| Model | FF65 CL |
| Detector Type | Image Intensifier-Based Laminography Detector |
| Sample Diameter | 795 mm |
| Sample Height | 20 mm |
| Max Sample Weight | 2 kg |
| System Dimensions | 1760 × 2000 × 2000 mm |
| CT Mode | Super-High-Resolution Computed Laminography (CL) |
| Manipulation | Super-Precise Manipulator with Active Anti-Vibration System |
| Vacuum Sample Hold Mechanism | Integrated |
| Effective Detection Area | 510 × 610 mm |
| X-ray Source | Next-Generation Nanofocus Tube (≤ 300 nm focal spot) |
| Brand | YXLON |
|---|---|
| Origin | Germany |
| Model | FF70 CL |
| Detector Type | High-Sensitivity Image Intensifier with Nano-Focus X-ray Source |
| Max. Sample Diameter | 795 mm |
| Max. Sample Height | 150 mm |
| Max. Sample Weight | 2 kg |
| System Dimensions (W×D×H) | 1940 × 2605 × 2000 mm |
| CT Mode | Ultra-High-Resolution Computed Laminography (CL) |
| Manipulation | Ultra-Precise Active Anti-Vibration Manipulator |
| Minimum Resolvable Feature Size | <150 nm |
| Inspection Area | 510 × 610 mm |