Physical Property Testing Instruments
Filter
Showing 841–870 of 4355 results
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | THERMOSEL |
| Pricing | Available Upon Request |
| Brand | TLS |
|---|---|
| Origin | Spain |
| Model | T-5333 |
| Application | Burst strength testing of paper and paperboard |
| Category | Physical property testing instrument / Tribological tester (burst-specific) |
| Import status | Imported |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ULA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ULA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Type | Newtonian Calibration Fluids |
| Variants | General-Purpose Silicone Oil Standards, High-Temperature Silicone Oil Standards, Hydrocarbon (Mineral Oil / Polybutene) Standards, CAP-Series Spindle-Specific Standards, KU-2 Krebs Units Standards, RST/RheoStress Coaxial & Cone Standards |
| Viscosity Range | 5–360,000 cP (mPa·s) at 25.0°C |
| Accuracy | ±1% of nominal viscosity |
| Temperature Stability | ≤±0.5% per °C (silicone oils) |
| Certified Traceability | NIST-traceable calibration documentation available upon request |
| Packaging | 600 mL glass or 1000 mL HDPE bottles |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | VTE |
| Instrument Type | In-line Viscometer |
| Viscosity Range | 10–10,000 cP |
| Output Signal | 4–20 mA (linear) |
| Accuracy | ±1% of full scale |
| Control Relay | 3 A solenoid-type |
| Enclosure Rating | NEMA 1 |
| Operating Environment | Ambient temperature |
| Compliance | Designed for continuous industrial process monitoring |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACOS |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | In-Line Laser Particle Size Analyzer |
| Measurement Range | Particle Size: 0.6 nm – 3 µm |
| Dynamic Concentration Range | 0.1 ppm – 40% (w/v) |
| Repeatability | Configurable per application protocol |
| Measurement Duration | User-Defined |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-200SM |
| Particle Size Range | 1 nm – 6 µm |
| Molecular Weight Range | 500 – 10⁹ Da |
| Hydrodynamic Size Range | 10 – 1000 nm |
| Scattering Angle Range | 8°–162°, ±0.01° |
| Temperature Control Range | −20 °C to 80 °C (optional −20 °C to 150 °C), ±0.1 °C |
| Laser Wavelength Options | 632.8 nm, 532 nm, 514.5 nm, 488 nm |
| Aperture Wheel Sizes | 100 µm, 200 µm, 400 µm, 1 mm, 2 mm, 3 mm |
| Correlator | TurboCorr digital photon correlator |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-870 |
| Measurement Range | 1–20 and 1–200 |
| Accuracy | ±2% |
| Repeatability & Linearity | ±0.2% |
| Max Sample Conductivity | 1 µS/cm (for range 1–20), 10 µS/cm (for range 1–200) |
| Minimum Sample Volume | 25 mL |
| Probe Material | Stainless Steel & PTFE |
| Excitation Signal | Low-distortion 10 kHz sine wave (7 Vrms for 1–20 range |
| Display | LCD |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-DCP / BI-XDC |
| Measurement Principle | Centrifugal & Gravitational Sedimentation |
| Repeatability | 1% |
| Accuracy | ±2% |
| Particle Size Range (BI-DCP) | 0.01–45 µm |
| Particle Size Range (BI-XDC) | 0.01–100 µm |
| Detection Method | Visible Light (BI-DCP) / X-ray (BI-XDC) |
| Sample Introduction | Layered (LIST mode) or Homogeneous (HOST mode) |
| Rotational Speed Range | 500–15,000 rpm (BI-DCP) |
| Speed Stability | ±0.01% |
| Disk Material | Standard PMMA or Corrosion-Resistant Alternative |
| Data Storage | Built-in extinction curve database (BI-DCP) |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | BI-MwA |
| Molecular Weight Range | 500–10⁹ Da |
| Hydrodynamic Size Range | 10–1000 nm |
| Scattering Volume | 20 nL |
| Sample Cell Volume | 100 µL |
| Maximum Back Pressure | 3.5 MPa (500 psi) |
| Detection Angles | 8 fixed angles (35°, 50°, 75°, 90°, 105°, 130°, 145° + reference angle) |
| Detector | High-Sensitivity CCD |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-ZTU |
| Pricing | Available Upon Request |
| pH Range | 2–12 |
| Sample Cell Option | Flow-Through Cell |
| Pump Tubing | 1 mm (0.04") ID, Compatible with Teflon®, PEEK®, and EPDM® |
| Included Accessories | Integrated pH Electrode + Four 100 mL Reagent Bottles |
| Drive System | Four Independent Peristaltic Pumps |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BioDLS |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Particle Size Range | 0.5 nm – 3 µm (sample-dependent) |
| Molecular Weight Range | 4 × 10² – 2 × 10⁷ Da (sample-dependent) |
| Concentration Range | 0.1 – 100 mg/mL (sample-dependent) |
| Sample Volume | 2 µL |
| Throughput | Up to 768 samples per run (2 × 384-well plates) |
| Temperature Control | Sample cell: 5–90 °C |
| Storage plate | Ambient to 4 °C |
| Laser Source | 35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm) |
| Scattering Angle | 90° |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s |
| Interface | USB 2.0 & 1.1 |
| Software | Windows XP/Vista compatible |
| Dimensions (w/d/h) | 300 × 510 × 630 mm (28 kg, no storage cooler) |
| Operating Environment | 10–75 °C, 0–95% RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOQELS |
| Pricing | Upon Request |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | 173Plus |
| Particle Size Range | 0.3 nm – 10 μm |
| Concentration Range | 0.1 ppm – 40% w/v |
| Typical Accuracy | ±1% |
| Sample Volume | 10–3000 μL (with 10 μL & 50 μL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Temperature Control | −5°C to 120°C (±0.1°C stability) |
| pH Range | 1–14 |
| Laser Source | 40 mW solid-state laser (optional 5 mW He-Ne) |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 4×10¹¹ linear channels, dual-channel cross-correlation support |
| Scattering Angles | 13°, 90°, and 173° (motorized, software-selectable) |
| Optional Modules | Micro-rheology, Zeta Potential, In-line Process Monitoring, Automated Titrator, Dielectric Constant Meter, Viscometer, 21 CFR Part 11 Compliant Software |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 173Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Size Analyzer |
| Measurement Range | 0.3 nm – 10 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 15°, 90°, 173° |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support |
| Sample Volume | 0.01–3 mL (with optional 50 µL and 10 µL micro-cells) |
| Molecular Weight Range | 342–2×10⁷ Da |
| pH Range | 1–14 |
| Software Compliance | 21 CFR Part 11 Ready |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 90Plus |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Sample Volume | 10–3000 µL |
| Laser Source | 40 mW Solid-State Laser |
| Detector | PMT or APD |
| Correlator | 4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support |
| Scattering Angles | 15° and 90° Options |
| Zeta Potential Option | Available |
| Software Compliance | 21 CFR Part 11 Audit Trail Mode |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90plus PALS |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Zeta Potential Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Scattering Angles | 15° and 90° |
| Laser Source | 40 mW Solid-State Laser (He-Ne Optional) |
| Detector | APD or PMT |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Sample Volume | 10 µL – 3 mL (with 10 µL & 50 µL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90Plus Zeta |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook Omni |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | <1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 13°, 90°, 173° |
| Zeta Potential Technique | Hardware-Based Phase Analysis Light Scattering (PALS) |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Sample Volume | 10 µL – 3 mL |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Optional Compliance | 21 CFR Part 11 Software Module |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPALS |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Electrophoretic Mobility Range | 1×10⁻¹¹ to 1×10⁻⁷ m²/V·s |
| Particle Size Range (optional DLS) | 0.001–100 µm |
| Sample Volume | 0.018–1.5 mL |
| Conductivity Range | 0–30 S/m |
| Electric Field Strength | 0–3.2 kV/m |
| Laser Source | 40 mW solid-state laser (wavelength & power customizable) |
| Detector | PMT or APD |
| Electrode Material | Palladium (corrosion-resistant open-cell capillary electrode optional) |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPlus |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Particle Size Range (Electrophoretic Mode) | 0.001–100 µm |
| Sample Volume | 0.18–1.5 mL |
| Conductivity Range | 0–20 S/m |
| Electrophoretic Mobility Range | 1×10⁻¹⁰ to 1×10⁻⁷ m²/V·s |
| Electric Field Strength | 0–3.2 kV/m |
| Electrode Material | Palladium (corrosion-resistant, open-cell design) |
| Laser Source | 35 mW solid-state laser (optional 5 mW He–Ne) |
| Detector | PMT or APD |
| Automated Trend Analysis | time-, temperature-, pH-, and conductivity-dependent |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDLS |
| Dispersion Method | Wet & Dry Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 0.5 nm – 3 µm (refractive index dependent) |
| Repeatability | ≤1% (typical) |
| Measurement Time | <10 s per acquisition (configurable) |
| Sample Volume | 2.5 µL |
| Max Operating Pressure | 400 bar (5,880 psi) |
| Concentration Range | 0.1–100 mg/mL |
| Temperature Control Range | 25–80 °C |
| Laser Source | 35 mW, 638 nm solid-state laser |
| Detector | Avalanche Photodiode (APD) |
| Scattering Angle | 90° |
| Interface | USB 2.0 & 1.1 |
| Data Output | Hydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots |
| Operation Mode | Auto-sampling or manual injection |
| Optional Integration | BI-MwA multi-angle static light scattering module for SEC-MALS coupling |
| Brand | Bruker |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hysitron TS 77 Select Nanoindenter |
| Instrument Type | Nanoindenter |
| Maximum Indentation Depth | µm |
| Effective Load Range | 100 nN – 10 mN |
| Load Resolution | <1 nN |
| Displacement Range | 1 nm – 10 µm |
| Displacement Resolution | <0.05 nm |
| Maximum Friction Force | 10 mN |
| Indenter Tip Geometry | Berkovich (triangular pyramid), Cube-corner, Flat-punch, and Custom trapezoidal tips |
| Thermal Drift | <0.05 nm/s |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SKYSCAN 1273 |
| X-ray Source Energy | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel, 3072 × 1944 pixels |
| Spatial Resolution | < 5 µm (3D) |
| Voxel Size | < 3 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm, up to 20 kg |
| Field of View | Ø250 mm × H250 mm |
| Image Matrix | up to 4800 × 4800 pixels |
| Detector Output Speed | High-frame-rate acquisition enabled |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |