Physical Property Testing Instruments
Filter
Showing 4291–4320 of 12427 results
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO3-W |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measuring Distance | 200 mm |
| Measurement Range | Water & Emulsion Residue (0.1–500 mg/m²) |
| Accuracy | ±5% of reading (typical, dependent on surface uniformity and substrate emissivity) |
| Repeatability | <±2 mg/m² |
| Sampling Frequency | Up to 120 Hz |
| Standoff Tolerance | ±20 mm vertical deviation |
| Operating Temperature | 0 °C to +55 °C |
| Enclosure Rating | IP65 |
| Dimensions (L×W×H) | 519 × 264 × 100 mm |
| Weight | 8 kg |
| Substrate Compatibility | Ferrous & non-ferrous metals, ceramic-coated strips |
| Output Interface | Analog 4–20 mA, RS-485, Ethernet (Modbus TCP / optional OPC UA) |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGO3-WATER |
| Price Range | USD 65,000 – 130,000 |
| Brand | Innovatest |
|---|---|
| Country of Origin | Netherlands |
| Manufacturer | Innovatest B.V. |
| Type | Rockwell Hardness Tester |
| Measurement Range | 10–100 HR |
| Total Test Force | 187.5 kgf |
| Test Space | 650 mm (H) × 175 mm (D) |
| Nose Extension Length | 170 mm |
| Test Table Dimensions | 425 mm × 370 mm (with hardened zone & T-slots) |
| Preload Forces | 3 kgf, 10 kgf |
| Main Load Range | 15–150 kgf |
| Loading System | Fully Automatic, Load Cell-Based Closed-Loop Control |
| Guidance System | Full-Height Linear Rails + Precision Ball-Screw Drive |
| Display | 6.5″ Industrial Touchscreen |
| Software | I-TOUCH™ Hardness Control Suite |
| Data Storage | Internal Memory (up to 150 readings) |
| Interface | USB |
| Illumination | Integrated LED Surface Lighting |
| Base Enclosure | Interchangeable ABS Protective Housing |
| Brand | INNOVATEST |
|---|---|
| Origin | Netherlands |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | NEXUS 3001XLM-IMP |
| Test Force Range | 30 kgf to 3000 kgf |
| Z-Axis Travel | 345 mm |
| Specimen Height Clearance | 335 mm |
| Depth Clearance | 220 mm |
| Turret | 2-position (indenter + Brinell objective with annular LED illumination) |
| Imaging System | 5 MP full-HD camera with motorized zoom and auto-focus |
| Control Interface | IMPRESSIONS™ software on 15″ industrial touchscreen |
| Measurement Method | Automated video-based indent diameter analysis per ISO 6506-1 and ASTM E10 |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | YND-OM4 |
| Temperature Range | RT to 500 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Up to 8 samples per run (configurable for 4/6/8) |
| DSC Range | 0 to ±500 mW |
| DSC Resolution | 0.01 mW |
| DSC Sensitivity | 0.01 mW |
| Gas Control | Dual-channel mass flow control (N₂/O₂), 0–200 mL/min, accuracy ±0.2 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Interface | Integrated USB 2.0 |
| Display | 7-inch color capacitive touchscreen |
| Compliance | GB/T 19466.3–2009 / ISO 11357-3:1999 (OIT determination) |
| Brand | INPROCESS-LSP |
|---|---|
| Origin | Netherlands |
| Model | NanoFlowsizer |
| Particle Size Range | 10–1000 nm |
| Size Reproducibility | ±2 nm |
| Temperature Range | −10 to 125 °C |
| Temperature Control Accuracy | ±0.5 °C (−10 to 85 °C), ±2.0 °C (85 to 125 °C) |
| Optical Signal Frequency | 76 Hz |
| Measurement Principle | Spatially Resolved Dynamic Light Scattering (SR-DLS) |
| Sample Concentration Range | Unrestricted |
| Minimum Sample Volume | ≥100 µL |
| Zeta Potential Range | Not applicable (dedicated particle sizing only) |
| Measurement Time | <10 s per acquisition |
| Brand | Insment |
|---|---|
| Model | KS-118D |
| Origin | Shanghai, China |
| Radiation Source Power | 500 W |
| Radiation Surface Diameter | Φ100 mm ± 5 mm |
| Sample Holder Inner Diameter | 118 mm (stainless steel ring) |
| Stainless Steel Mesh | Wire diameter 0.70 mm, aperture 2.10 mm |
| Sample Dimensions | 70 mm × 70 mm, max thickness 13 mm |
| Drip Catcher Diameter | Φ118 mm, depth 12 mm |
| Distance from Sample Upper Surface to Radiant Source | 30 mm |
| Distance from Sample Holder to Drip Catcher (cotton pad) | 300 mm |
| Heat Flux Meter Range | 10 W/cm² |
| Overall Dimensions | 1120 mm (W) × 580 mm (D) × 1350 mm (H) |
| Exhaust Port Diameter | Φ100 mm |
| Power Supply | AC 220 V, 50 Hz, ≤1000 W |
| Compliance | UN ECE Regulation No. 118, Annex 7 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | InspectIR |
| Pricing | Available Upon Request |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS302 |
| Temperature Range | −190 °C to 400 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C at 100 °C |
| Max Heating Rate | +100 °C/min at 100 °C |
| Max Cooling Rate | −100 °C/min at 100 °C |
| Min Working Distance | 3.3 mm (outer window removed) |
| Operating Working Distance | 5.6 mm |
| Condenser Distance | 10.0 mm |
| Sample Area | 38 mm × 50 mm |
| Chamber Height | 2.0–12.5 mm (with optional spacers) |
| Viewing Aperture Options | 2 / 5 / 8 / 10 mm |
| Optional X-Y Micropositioner | 10 µm resolution |
| Temperature Sensor | 100 Ω Platinum RTD |
| Control Method | Switching PID (LVDC PID optional) |
| Frame Capacity | 1,000 kN |
|---|---|
| Test Speed | 100 mm/min |
| Actuator Stroke | 254 mm |
| Crosshead Adjusting Speed | 300 mm/min |
| Compression Opening | 0–1000 mm |
| Horizontal Opening (Between Columns) | 741 mm |
| Test Space Configuration | Dual-Space (Tension & Compression) |
| Jaw Interface | Hydraulic Open-Front & Manual Closed-Pocket Crossheads |
| Specimen Flexibility | Multi-size Coverage with Minimal Jaw Face Set |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 2340 Series |
| Load Capacity Options | 2 kN (2344) / 5 kN (2345) |
| Vertical Test Space | 1123 mm (standard), up to 1383 mm (high-rise variant) |
| Load Accuracy | ±0.5% of indicated load |
| Force Resolution | Down to 1/200 of full-scale capacity without loss of accuracy |
| Data Acquisition Rate | 500 Hz |
| Compliance | CE-marked |
| Control & Software | Fully software-controlled with automatic transducer recognition |
| Fixture Compatibility | Extensive library of standardized and application-specific grips and tooling |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 2360 Series |
| Load Capacity Options | 5 kN, 10 kN, 30 kN, 50 kN |
| Load Accuracy | ±0.5% of indicated load |
| Force Resolution | 1/200 to full scale without loss of accuracy |
| Data Acquisition Rate | 500 Hz |
| Vertical Test Space | 1193 mm (47 in) across all models |
| Maximum Crosshead Speed | 1000 mm/min (2365 model), 500 mm/min (2366/2367/2369 models) |
| Compliance | CE-marked |
| Sensor Recognition | Automatic |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 2380 |
| Type | Electromechanical Tensile and Compression Testing Machine |
| Load Capacity | Up to 100 kN (22,500 lbf) |
| Load Accuracy | ±0.5% of indicated load |
| Force Resolution | 1/200 to full scale without accuracy loss |
| Data Acquisition Rate | 500 Hz |
| Crosshead Speed Range | Up to 500 mm/min (20 in/min) |
| Vertical Test Space | 1323 mm (51.3 in) |
| Compliance | CE-marked |
| Software | Bluehill Universal (fully integrated, sensor auto-recognition enabled) |
| Fixture Compatibility | Extensive catalog of ASTM-, ISO-, and ISO 17025-aligned grips and tooling |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 2380 Series |
| Load Capacity | 100 kN (2382) / 300 kN (2386) |
| Load Accuracy | ±0.5% of indicated load |
| Force Resolution | 1/200 to full scale without accuracy loss |
| Data Acquisition Rate | 500 Hz |
| Crosshead Speed | up to 500 mm/min (20 in/min) |
| Vertical Test Space | 1323 mm (2382) / 1282 mm (2386) |
| Compliance | CE-marked |
| Sensor Recognition | Automatic |
| Software Control | Fully integrated via Bluehill Universal |
| Fixture Compatibility | Thousands of standardized and custom test fixtures available |
| Instrument Type | Electromechanical Tensile and Compression Testing System |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 3300 Series |
| Load Capacity Options | 5 kN, 10 kN, 30 kN, 50 kN |
| Load Accuracy | ±0.5% of reading (down to 2% of full scale) |
| Strain Accuracy | ±0.5% of reading (down to 2% of extensometer full scale) |
| Crosshead Speed Range | 0.005–1000 mm/min |
| Speed Accuracy | ±0.2% of set speed |
| Drive System | High-torque DC motor with digital closed-loop position control |
| Screw Type | Preloaded recirculating ball screw with anti-backlash design |
| Column Configuration | Dual-column with T-slot equipped column shrouds |
| Software | Bluehill Lite (multi-language, including Chinese UI) |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 3340 |
| Load Capacity Options | 0.5 kN, 1 kN, 2 kN, 5 kN |
| Vertical Test Space | 651–1383 mm |
| Force Accuracy | ±0.5% of indicated load |
| Force Resolution | 100:1 (down to 1.0% of sensor capacity without loss of accuracy) |
| Data Acquisition Rate | 500 Hz (with Bluehill 3 or Bluehill LE software) |
| Compliance | CE-marked |
| Sensor Recognition | Automatic |
| Software Control | Full PC-based control with optional cyclic testing capability |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 3340 |
| Load Capacity | 0.5–5 kN |
| Vertical Test Space | 651–1383 mm |
| Load Accuracy | ±0.5% of reading |
| Force Resolution | 100:1 range (down to 1.0% of sensor capacity without loss of accuracy) |
| Data Acquisition Rate | 500 Hz |
| Compliance | CE-certified |
| Instrument Type | Electromechanical Universal Testing Machine |
| Software | Bluehill® 3 and Bluehill LE |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3360 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 5 kN / 10 kN / 30 kN / 50 kN |
| Maximum Crosshead Speed | 500–1000 mm/min |
| Vertical Test Space | 1193 mm |
| Load Accuracy | ±0.5% of indicated load |
| Force Resolution | 100:1 force range (down to 1.0% of sensor capacity without loss of accuracy) |
| Data Acquisition Rate | 500 Hz (Bluehill® 3), 100 Hz (Bluehill & Bluehill LE) |
| Compliance | CE-certified |
| Warranty | 12-month comprehensive service coverage (parts and labor) |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 3360 Dual-Column Universal Testing System |
| Load Capacity Options | 5 kN, 10 kN, 30 kN, 50 kN |
| Force Accuracy | ±0.5% of reading |
| Force Resolution Ratio | 100:1 (down to 1.0% of sensor capacity without loss of accuracy) |
| Data Acquisition Rate | 500 Hz (BlueHill® 3), 100 Hz (BlueHill & BlueHill LE) |
| Vertical Test Space | 1193 mm (47 in) |
| Crosshead Speed Range | Up to 1000 mm/min (3365 model) or 500 mm/min (3366/3367/3369 models) |
| Compliance | CE-compliant |
| Software | BlueHill® Suite with optional cyclic testing, automatic sensor recognition, and self-diagnostics |
| Warranty | 12-month comprehensive service coverage (parts and labor) |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Product Type | Electromechanical Universal Testing Machine |
| Model Numbers | 34TM-5 / 34TM-10 / 34TM-30 / 34TM-50 / 34TM-100 |
| Maximum Load Capacity | 5 kN, 10 kN, 30 kN, 50 kN, or 100 kN |
| Load Accuracy Class | ISO 7500-1 Class 0.5 and Class 1 |
| Data Acquisition Rate | Up to 1 kHz (simultaneous force, displacement, and strain channels) |
| Displacement Accuracy | ±0.02 mm or ±0.15% of reading (whichever is greater) |
| Speed Accuracy | ±0.2% of set speed (at zero or constant load) |
| Power Supply | 100–240 VAC ±10%, 47–63 Hz (single-phase) |
| Operating Temperature | +5 °C to +40 °C |
| IP Rating | IP2X |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Product Type | Electromechanical Universal Testing Machine |
| Model | 34FM-100 / 34FM-300 |
| Load Capacity | 100 kN / 300 kN |
| Load Accuracy | ±0.5% of reading (full scale to 1/250 FS), ±1.0% of reading (1/250 FS to 1/500 FS) |
| Displacement Accuracy | ±0.02 mm or ±0.15% of reading (whichever is greater) |
| Data Acquisition Rate | Up to 1 kHz (synchronized force, displacement, strain) |
| Power Supply | Single-phase 208–240 VAC ±10%, 47–63 Hz |
| Operating Temperature | +5°C to +40°C |
| IP Rating | IP2X |
| Compliance | CE-marked, compliant with applicable EN, ISO 7500-1, ASTM E4, ASTM E83, ISO 9001, and GLP/GMP-relevant traceability requirements |
| Brand | INSTRON |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | 34SC-05 / 34SC-1 / 34SC-2 / 34SC-5 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | Up to 5 kN |
| Force Measurement Accuracy | ±0.5% of reading from 0.4% to 100% FS |
| Displacement Accuracy | ±0.02 mm or ±0.15% of reading (whichever is greater) |
| Speed Accuracy | ±0.2% of set speed (at zero or constant load) |
| Data Acquisition Rate | Synchronized force, displacement, and strain channels up to 1 kHz |
| Motor Type | Brushless AC Servo Motor |
| Operating Temperature | 5–40°C |
| IP Rating | IP2X |
| Compliance | ASTM, ISO, GB, USP, FDA 21 CFR Part 11 (via Bluehill Universal software) |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Model | 34TM-100 |
| Load Capacity | 100 kN |
| Load Accuracy | ±0.5% of reading (down to 1/250 FS), ±1% of reading (down to 1/500 FS) |
| Crosshead Travel | 1097 mm (E1), 1582 mm (E2) |
| Vertical Test Space | 1168 mm (E1), 1672 mm (E2) |
| Horizontal Test Space | 420 mm |
| Speed Range | 0.05–508 mm/min |
| Position Resolution | 16.78 nm |
| Frame Axial Stiffness | 180 kN/mm |
| Data Acquisition Rate | Up to 1 kHz (synchronized force, displacement, strain) |
| Power Supply | 100–240 VAC ±10%, 47–63 Hz |
| Operating Temperature | 5–40°C |
| IP Rating | IP2X |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3621 |
| Pricing | Upon Request |
| Brand | Instron |
|---|---|
| Origin | USA |
| Model | 5960 Series |
| Load Capacity Range | 5 kN to 50 kN (5965–5969 models) |
| Type | Electromechanical Universal Testing Machine |
| Compliance | ASTM E4, E8, E9, E21, ISO 6892-1, ISO 527, ISO 178, USP <1041>, FDA 21 CFR Part 11 (with Bluehill software configuration) |
| Control Interface | Integrated Ethernet (10/100/1000BASE-T) |
| Data Acquisition Rate | Up to 5 kHz (standard), configurable higher with optional modules |
| Speed Range | 0.001–2500 mm/min (model-dependent) |
| Return Speed | Up to 2500 mm/min |
| Sensor Channels | Up to 4 built-in analog input channels for load, strain, displacement, and environmental sensors |
| Software Platform | Bluehill Universal v4.x or later |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Product Type | Electromechanical Universal Testing System |
| Load Capacity Options | 400 kN (5988) / 600 kN (5989) |
| Vertical Test Space | 2050 mm (5988) / 2000 mm (5989) |
| Control Architecture | Digital Closed-Loop Servo-Controlled |
| Compliance Standards | ASTM E4, E8, E9, E21, ISO 7500-1, ISO 5893, USP <1041>, FDA 21 CFR Part 11 (with Bluehill software configuration) |
| Data Acquisition Rate | Up to 10 kHz |
| Speed Range | 0.001–1000 mm/min (programmable in 0.001 mm/min increments) |
| Position Resolution | ≤ 0.1 µm |
| Load Cell Options | 1 N to 600 kN full-scale, interchangeable via Auto-ID recognition |
| Integrated Interfaces | Gigabit Ethernet, USB 3.0, Analog I/O (up to 4 channels), Digital I/O |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Product Type | Electromechanical Universal Testing Machine |
| Model Numbers | 68TM-5, 68TM-10, 68TM-30, 68TM-50, 68TM-100 |
| Maximum Load Capacity | 5 kN, 10 kN, 30 kN, 50 kN, or 100 kN |
| Load Accuracy Class | 0.5 or 1 (per ISO 7500-1 / ASTM E4) |
| Data Acquisition Rate | Up to 5 kHz (simultaneous force, displacement, strain) |
| Force Measurement Accuracy | ±0.5% of reading from 0.1% to 100% FS (with 2580 series load cells + Advanced Performance option) |
| Displacement Accuracy | ±0.01 mm or ±0.05% of reading (whichever is greater) |
| Strain Measurement Compliance | ASTM E83, ISO 9513, EN 10002-4, BS 3846 |
| Speed Accuracy | ±0.1% of set speed (under zero or constant load) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP2X |
| Power Supply | 100–240 VAC ±10%, 47–63 Hz |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 68FM-100 / 68FM-300 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 100 kN, 300 kN |
| Load Accuracy | Class 0.5 per ISO 7500-1 and ASTM E4 |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 68FM-100 / 68FM-300 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | Up to 300 kN |
| Software Platform | Bluehill® Universal |
| Compliance | ASTM, ISO, GB Standards |
| Drive System | Brushless AC Servo Motor |
| Continuous Operation Capability | Up to 10 days (cyclic, creep, relaxation) |
| Base Construction | 12 mm Thick Wear-Resistant Coated Steel Table |
| Safety Architecture | Patented Operator Protection System with Workflow-Governed State Control |
| Positioning | Automated Gauge Length Recall & Collision-Avoidance Beam Stop |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Product Type | Electromechanical Universal Testing Machine |
| Model Variants | 68SC-05 / 68SC-1 / 68SC-2 / 68SC-5 |
| Load Capacity | Up to 5 kN |
| Compliance | ASTM, ISO, GB, USP, FDA 21 CFR Part 11 (via Bluehill® Universal), GLP/GMP-ready |
| Data Acquisition Rate | Up to 5 kHz (force, displacement, strain synchronized) |
| Force Accuracy | ±0.5% of reading from 0.1% to 100% FS (with 2580 series load cells, Advanced Performance option) |
| Displacement Accuracy | ±0.01 mm or 0.05% of reading (whichever is greater) |
| Strain Accuracy | Compliant with ASTM E83, ISO 9513, EN 10002-4, BS 3846 |
| Operating Temperature | 5–40°C |
| Power Supply | 100–240 VAC ±10%, 47–63 Hz |
| IP Rating | IP2X |