Physical Property Testing Instruments
Filter
Showing 61–90 of 4353 results
| Brand | AcroEdge |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Syclus |
| Instrument Category | Compact Vibration-Based Fatigue Tester |
| Frequency Range | 1–20 Hz |
| Maximum Displacement Amplitude | ±600 µm |
| Load Capacity | ±25 N (±0.5% nonlinearity) |
| Sample Dimensions | Length 25–35 mm |
| Geometry | Films, Fibers, Thin Specimens |
| Control Interface | USB-connected PC with Dedicated Software |
| Sampling Rate | Up to 2000 pts/sec |
| Data Storage Modes | Linear (N cycles per T minutes) or Logarithmic (10, 100, 1000, …, 10ⁿ cycles) |
| Failure Detection | Programmable load threshold trigger with pre-failure cycle preservation (3 cycles prior to failure) |
| System Dimensions (Tester) | L100 × W100 × H500 mm (vertical orientation) |
| Controller Dimensions | L250 × W250 × H150 mm |
| Tester Mass | ~3 kg |
| Controller Mass | ~5 kg |
| Power Supply | 100 V, 10 A |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 32 |
| Maximum Penetration Depth | 3 m (concrete-dependent) |
| Maximum Coverage Area | 10 × 10 m |
| Frame Rate | 25 Hz (2D), 2 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485-2019, DB32/T 3754-2020, DB34/T 5072-2017, DB37/T 5106-2018, DG/TJ 08-2252-2018, DB13(J)/T 8327-2019, DBJ/T-199-2020 |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA 3D Pro |
| Frequency Bandwidth | 10–100 kHz |
| Parallel DAQ Channels | 64 |
| Maximum Penetration Depth | 4 m (concrete-dependent) |
| Maximum Scanning Area | 10 × 10 m |
| Frame Rate | 12 Hz (2D), 0.3 Hz (3D) |
| Battery Life | Up to 10 h per charge |
| Sensor Configuration | 4 × 16 or 8 × 8 A-DPC® array (expandable) |
| Compliance | T/CECS XXX-202X, JGJ/T 485–2019, DB32/T 3754–2020, DB34/T 5072–2017, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DBJ/T–199–2020 |
| Brand | ACS |
|---|---|
| Origin | Hong Kong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A1052 MultiSONIC |
| Price Range | USD 1–2 (Unit Price Indicative |
| Channels | 32-channel pulser-receiver array |
| Connectivity | Integrated Wi-Fi interface (IEEE 802.11 b/g/n, 2.4 GHz) |
| Power Supply | Rechargeable Li-ion battery (operational autonomy ≥ 6 h) |
| Excitation | Bipolar pulse burst with user-defined frequency, half-cycle duration, and number of half-cycles |
| Compatible Transducers | All ACS dry-point contact ultrasonic transducers (e.g., A101x series, 20–500 kHz nominal bandwidth) |
| Encoding Support | Golay complementary sequence excitation (length up to 64 bits) |
| Software | MATHILDA32 (free demonstration version included) |
| Operating Modes | Pulse-echo, through-transmission, pitch-catch |
| Compliance | CE, RoHS, FCC Part 15 Subpart B |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1410 Pulsar |
| Price | USD 6,800 (FOB Italy) |
| Brand | ACS |
|---|---|
| Temperature Range Options | 0°C to +150°C (Model B) |
| Internal Volume | 80 L, 150 L, 225 L, 408 L, 800 L, or 1000 L |
| Temperature Uniformity | ±1.5°C |
| Temperature Stability | ±0.5°C |
| Humidity Range | 20–98% RH |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2% RH |
| Heating Rate (non-linear, no-load) | ~3°C/min |
| Cooling Rate (non-linear, no-load) | ~1°C/min |
| Construction | AISI 304 stainless steel interior & exterior |
| Insulation | Rigid polyurethane foam + glass wool |
| Refrigeration System | Hermetic scroll compressors (Tecumseh or Copeland), eco-friendly refrigerant (R404A/R507) |
| Controller | TEMI880 color touchscreen programmable climate controller (English/Chinese UI) |
| Air Circulation | Wide-band vertical airflow (top-out, bottom-in) |
| Condensation Management | Automatic drain system with digital pressure monitoring |
| Compliance | Designed for ISO 16750-4, IEC 60068-2-14, MIL-STD-810H, JIS Z 8701, and ASTM D4332 environmental stress testing |
| Brand | ACS |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A1040 MIRA |
| Pricing | Upon Request |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Model | SU250 |
| Instrument Type | Upright Chamber |
| Temperature Range | −40 °C to +180 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity | ≤ ±0.5 °C |
| Humidity Uniformity | ≤ ±3 % RH (at >75 % RH) / ≤ ±5 % RH (at ≤75 % RH) |
| Heating Rate | 3 °C/min |
| Internal Dimensions (W×D×H) | 600 × 600 × 700 mm |
| Compliance | IEC 60068-3-5, IEC 60068-3-6, EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-30 |
| Brand | AcuiTik |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Line | NS-Micro Series |
| Wavelength Range | 190–1000 nm |
| Thickness Measurement Range | 1–100 µm |
| Measurement Accuracy | ±1 nm or ±0.2% (whichever is greater) |
| Measurement Precision | 0.02 nm (1σ, 100 measurements on 500 nm SiO₂ reference) |
| Stability | 0.05 nm (2σ mean drift over 20 operational days) |
| Measurement Speed | <1 s per static point |
| Objective Options | 5×, 10×, 15×, 20×, 50×, 100× |
| Spot Size Range | 1–100 µm |
| Sample Diameter Capacity | 1 mm to ≥300 mm |
| Light Source | Deuterium + Tungsten-Halogen Lamp |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NS-20 |
| Price Range | USD 7,000 – 35,000 |
| Wavelength Range | 190–1700 nm (configurable UV/VIS/NIR variants) |
| Thickness Measurement Range | 1 nm – 250 µm (dependent on optical configuration) |
| Accuracy | ±1 nm or ±0.2% (UV variant) |
| Precision (repeatability) | 0.02 nm (UV/VIS), 0.1 nm (NIR) |
| Stability (8-hour drift) | ≤0.05 nm (UV/VIS), ≤0.12 nm (NIR) |
| Spot Size | 1.5 mm diameter |
| Measurement Speed | <1 s per single-point acquisition |
| Light Source | Tungsten-halogen + Deuterium lamp (UV), Tungsten-halogen only (VIS/NIR) |
| Sample Diameter Compatibility | 1 mm – 300 mm (custom larger stages available) |
| Brand | AcuiTik |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS-20 Pro |
| Price | Upon Request |
| Wavelength Range | 400–700 nm (non-UV, non-actinic) |
| Measurement Range | 15 nm – 1.5 mm |
| Measurement Precision | < 0.02 nm (static repeatability) |
| Spot Size | Standard 0.2 mm (optional micro-spot configuration available) |
| Configuration Options | Benchtop, Portable, and In-Line Integration Capable |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | NS-30 |
| Wavelength Range | 190–1700 nm (configurable UV/VIS/NIR variants) |
| Thickness Measurement Range | 1 nm – 250 µm |
| Accuracy | ±1 nm or ±0.2% (UV variant) |
| Precision | 0.02 nm (UV/VIS), 0.1 nm (NIR) |
| Stability | ≤0.05 nm (UV/VIS), ≤0.12 nm (NIR) |
| Spot Size | 1.5 mm |
| Single-Measurement Time | <1 s |
| Sample Diameter Capacity | 1 mm – 300+ mm |
| Automated Stage Travel | Up to 450 mm × 450 mm |
| Stress & Bow Measurement | Yes |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | NS-OEM |
| Wavelength Range | 190–1100 nm |
| Thickness Measurement Range | 1 nm – 1 mm |
| Accuracy | ±2 nm or ±0.2% |
| Static Repeatability | ±0.02 nm |
| Spot Size | 1.5 mm |
| Measurement Speed | <1 s per acquisition |
| Light Source | Tungsten-Halogen Lamp (with optional Deuterium lamp) |
| Probe-to-Host Interface | Fiber Optic (standard length 1.3 m, up to 20 m configurable) |
| Probe Dimensions | Ø19 mm × 86 mm |
| Power Supply | 90–264 VAC, 47–63 Hz |
| Brand | AcuiTik |
|---|---|
| Origin | China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | NS-Touch |
| Wavelength Range | 190–1700 nm |
| Thickness Measurement Range | 0.02 µm – 250 µm |
| Thickness Accuracy | ±0.01 µm or ±0.2% (whichever is greater) |
| Brand | AcuiTik |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | NS-Vista |
| Wavelength Range | 190–1700 nm |
| Thickness Measurement Range | 1 nm – 250 µm |
| Accuracy | ±1 nm or ±0.2% (UV configuration) |
| Precision | 0.02 nm (UV/Vis), 0.1 nm (NIR) |
| Stability | 0.05 nm (UV/Vis), 0.12 nm (NIR) |
| Spot Size | Adjustable from 0.2 mm to 1.5 mm |
| Measurement Speed | <1 s per acquisition |
| Light Source | Tungsten-halogen + Deuterium lamp (UV), Tungsten-halogen (Vis/NIR) |
| Sample Diameter Compatibility | 1 mm – 300 mm (or larger) |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | ST10 |
| Compliance | ASTM D4740 |
| Operating Temperature | Filter Paper 100 °C ±0.2 °C, Fuel Sample 93 °C ±0.2 °C |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Up to 100,000 test records with full image metadata |
| Connectivity | RJ45 Ethernet port, 4× USB 2.0 ports |
| Dimensions (W×D×H) | 420 × 350 × 222 mm |
| Weight | 9 kg |
| Power Supply | 230 V AC, 2 A, 50 Hz |
| Sample Handling | Manual droplet deposition via supplied micro-pipette |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | F-CAL |
| Measurement Principle | Heat Flow Method |
| Thermal Resistance Range | 1×10⁻⁵ m²·K/W |
| Repeatability | <2% fluctuation |
| Test Atmosphere | Ambient air |
| Hot-Side Temperature Setting | 50°C |
| Sample Geometry | Square, 25 mm or 40 mm edge length, thickness 1–5 mm |
| Instrument Type | Steady-State Thermal Resistance Analyzer |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | F-PEM |
| Operating Atmosphere | Ambient Air |
| Temperature Range | Room Temperature to 600 °C (Heating Zone) |
| Sample Size | Square, 40 mm × 40 mm × (5–30) mm Thickness |
| Power Supply | AC200V, 5 kW (Main Unit) |
| Dimensions | W600 × D600 × H1700 mm |
| Weight | ~120 kg |
| Contact Force | Up to 160 kgf (via Constant-Pressure Spring Mechanism) |
| Measured Parameters | Maximum Output Power (P<sub>max</sub>), Heat Flow Rate (Q), Thermoelectric Conversion Efficiency (η) |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | HT-RTA59HD |
| Heating Method | High-Power Focused Halogen Lamp |
| Max Temperature | 1800 °C (achieved in ≤10 s for □15 mm samples) |
| Sample Chamber Atmosphere | Dual-gas inlet (N₂ and Ar), quartz tube encapsulation |
| Cooling | Forced-air cooling for lamp assembly |
| Form Factor | Benchtop, manual slide-rail sample loading |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Advance Riko |
| Pricing | Available Upon Request |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | Mini-PEM |
| Operating Temperature Range (Hot Side) | 50–500 °C |
| Sample Dimensions | 2–10 mm × 1–20 mm (square/rectangular bulk) |
| Atmosphere | Vacuum-compatible |
| Measured Parameters | Thermoelectric conversion efficiency (η), electrical power output, heat flux |
| Measurement Principle | Simultaneous four-probe electrical characterization + calibrated heat flux sensor (thermopile-based) |
| Compliance | Designed for ASTM E3049–22 (Standard Practice for Measuring Thermoelectric Module Efficiency) and ISO 14405-1:2016 (Geometrical product specifications) alignment |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | Peltier Evaluation System |
| Measurement Atmosphere | Vacuum |
| Temperature Range | 27–80 °C |
| Sample Dimensions | Square, 10–25 mm side length, thickness ≤ 3 mm |
| Measured Parameters | ΔTₘₐₓ (maximum temperature difference), Qc,ₘₐₓ (maximum cooling power), COP (coefficient of performance) |
| Compliance | Designed for thermoelectric module characterization per ISO 14405-1 and ASTM D5470 practices |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | PEM-2 |
| Maximum Temperature Gradient | 500 °C (up to 800 °C heating surface) |
| Sample Geometry | Square, 20/30/40 mm × 5–30 mm thickness |
| Contact Pressure | 2 MPa (at 30 mm square sample) |
| Atmosphere | Inert gas compatible |
| Measurement Method | One-dimensional heat flux input method |
| Measured Parameters | Thermoelectric conversion efficiency (η), electrical power output (P), thermal input flux (Q) |
| Heating System | High-precision infrared gold-mirror furnace |
| Cooling System | Integrated water-cooled lower stage |
| Load Control | Automated variable resistive load adjustment |
| Software | Fully integrated control with thermal stability detection, real-time data logging, and automated test sequencing |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model Series | PS, PSS |
| Heating Zone Width (PS) | 40 mm |
| Heating Zone Width (PSS) | 20 mm |
| Compatible Substrate Diameter | 50–300 mm |
| Application Scope | Rapid thermal processing (RTP), wafer annealing, solar cell sintering, FPD substrate heating, thin-metal foil annealing |
| Configuration | Modular assembly for extended heating zones |
| Compliance | Designed for integration into Class 100–1000 cleanroom-compatible production lines |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | RHL-E Series |
| Heating Principle | Radiative heating via high-intensity near-infrared lamp array with water-cooled gold-coated elliptical reflector |
| Max Operating Temperature (E-type) | Up to 1200°C |
| Lamp Spectral Peak | ~1.15 µm |
| Reflector Material | Precision-polished aluminum substrate with vacuum-deposited Au coating |
| Cooling | Integrated water-circulation jacket for reflector and chamber housing |
| Sample Geometry Compatibility | Cylindrical/rod-shaped specimens |
| Reflective Geometry | Elliptical (E-series) |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super LIX-R |
| Price | Upon Request |
| Temperature Range (°C) | 0–50 |
| Heating/Cooling Rate (°C/min) | 0.01–1.5 |
| Temperature Accuracy (°C) | ±0.1 |
| Sample Diameter (mm) | Φ5 ±0.5 |
| Sample Length (mm) | 12–20 |
| Measurement Range (µm) | 20 |
| Resolution (nm) | <0.2 |
| CTE Detection Limit | 5 × 10⁻⁹ K⁻¹ |
| Thermal Stability | <±0.001 °C/min at 0.1 °C/min ramp |
| Atmosphere | Low-pressure He (100 Pa) |
| Sensor | PT-100 Platinum RTD (JIS C 1604-1997 Class A) |
| Laser | He-Ne, 632.8 nm, 5 mW (IEC 60825-1 Class 3B) |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | TC-1200RH |
| Measurement Principle | Laser Flash Method (LFM) |
| Temperature Range | RT to 1150 °C (up to 1200 °C short-term) |
| Thermal Conductivity Range | 0.1–2000 W/m·K |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Dimensions | Ø10 mm × 1–3 mm (thickness), measured through-thickness |
| Atmosphere | Vacuum (standard) |
| Heating Rate | 10 °C/min (to 100 °C), 20 °C/min (to 300 °C), 50 °C/min (to 1150 °C) |
| Dimensions (W×D×H) | 900 × 1050 × 1700 mm |
| Weight | ~350 kg |
| Power Supply | AC200 V, single-phase, 8 kVA (main unit) |
| Cooling Water | ≥5 L/min, pressure ≥0.15 MPa |
| Compliance | JIS R 1611, JIS R 1650-3, JIS H 7801, ISO 13826, ASTM E1461 |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | TCN-2ω |
| Measurement Principle | 2ω Lock-in Thermography (Frequency-Domain Modulated Joule Heating) |
| Test Temperature | Ambient (23 ± 2 °C) |
| Sample Dimensions | 10–20 mm (L) × 10 mm (W) × 0.3–1 mm (total thickness, including substrate) |
| Substrate Materials | Si (recommended), Ge, Al₂O₃ |
| Metal Transducer Film | Au (100 nm, 1.7 mm × 15 mm) |
| Thermal Conductivity Range | 0.1–10 W·m⁻¹·K⁻¹ |
| Atmosphere | Ambient air |
| Compliance | ISO/IEC 17025-aligned methodology, compatible with GLP documentation workflows |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Model | WET-1200 |
| Temperature Range (Static Drop) | Ambient to 1500 °C |
| Temperature Range (Extrusion Drop, optional) | Ambient to 1200 °C |
| Sample Substrate | Ø10 mm × 2 mm |
| Measurement Atmospheres | Vacuum, Controlled Gas Flow, Ambient Air |
| Measurement Methods | Static Drop Method, Optional Extrusion Drop Method |
| Application Scope | High-temperature wettability analysis of molten metals, alloys, glasses, and ceramics against solid substrates |
| Brand | Advance Riko |
|---|---|
| Origin | Japan |
| Model | ZEM-3 |
| Temperature Range | 50–800 °C (ZEM-3M8) / 50–1000 °C (ZEM-3M10) |
| Sample Geometry | Square (2–4 mm × 6–22 mm L) or Circular (Ø2–4 mm × 6–22 mm L) |
| Heating Method | Infrared gold-coated furnace with micro-heater for ΔT control |
| Max. Sample ΔT | 50 °C |
| Atmosphere | Ultra-high-purity helium (99.999%) |
| Automation | Fully computer-controlled measurement with background EMF compensation |
| Contact Verification | Real-time V–I curve analysis for ohmic contact validation |
| Optional Accessories | Thin-film adapter, cryogenic module (−100 to 200 °C), high-resistivity kit (up to 10 MΩ) |