Physical Property Testing Instruments
Filter
Showing 1531–1560 of 4494 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FID-100W |
| Pricing | Available Upon Request |
| Brand | KLA |
|---|---|
| Origin | USA |
| Manufacturer | Filmetrics (a KLA company) |
| Type | Benchtop Spectroscopic Reflectometry System |
| Model | F3-sX |
| Wavelength Options | 980 nm / 1310 nm / 1550 nm |
| Thickness Range | 15 nm – 3 mm (depending on configuration and film type) |
| Spot Size | 10 µm |
| Material Library | >130 preloaded optical constants |
| Software | FILMeasure 8 (local acquisition & analysis), FILMeasure Standalone (remote data processing) |
| Compliance | Designed for semiconductor fab, R&D, and QC environments supporting GLP/GMP traceability workflows |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | CMS2/STEP |
| Measurement Principle | Coulometric (Anodic Dissolution) per DIN EN ISO 2177 & ASTM B764-94 |
| Application Scope | Single/Multi-layer Metallic Coatings on Conductive or Non-conductive Substrates (e.g., Fe, Cu, ABS, PCB) |
| Thickness Range | 0.05–50 µm |
| Electrolytic Rate Selection | 0.1–10 µm/min |
| Measured Area | 0.6–3.2 mm² (via interchangeable O-rings) |
| STEP Function | Simultaneous Thickness & Potential Difference Measurement (Ni multilayer systems) |
| Display | High-resolution color LCD |
| Software Features | Graphical voltage curve display, statistical analysis, multi-language UI, configurable units |
| Compliance | DIN EN ISO 2177, ASTM B764-94, DIN 50022 |
| Accessories | V18 semi-automated stand with spherical support & rotating sample plate, 3-position electrolyte bottle holder (100 mL each) |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Models | PMP10, RMP30-S, MPO, FMP |
| Pricing | Available Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | ST30 |
| Instrument Type | Micro/Nano Scratch Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Load Range | 0.01–30 N |
| Load Resolution | 0.7 µN |
| Displacement Range | 100 mm |
| Displacement Resolution | 0.01 nm |
| Maximum Friction Force | 50 N |
| Indenter Type | Rockwell Indenter |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Aode305-11231 |
| Product Type | Intelligent |
| Display Interface | PC-based Software |
| Measurement Range | 0.20–50 µm |
| Repeatability | ±3% |
| Porosity Range | 0.25–0.95 |
| Inlet Gas Pressure | 3 kPa |
| Brand | FlowCam |
|---|---|
| Origin | Japan |
| Model | FlowCam 5000 |
| Particle Size Range | 3–300 µm |
| Camera Resolution | 1920 × 1200 pixels (color CMOS) |
| Frame Rate | up to 100 fps |
| Optical Configurations | 4X (300 µm depth), 10X (100 µm depth), 20X (50 µm depth) |
| Sample Flow Rate | 0.05–2 mL/min |
| Max Particle Concentration | 4 × 10⁶ particles/mL (at 3 µm) |
| Dimensions | 44 × 25 × 27 cm |
| Weight | 10 kg (operational), 24 kg (shipping) |
| Power Consumption | ≤92 W |
| Brand | Force |
|---|---|
| Origin | Denmark |
| Model | ERE 20 |
| Type | Embedded Half-Cell Reference Electrode |
| Electrode Material | Manganese Dioxide (MnO₂) |
| Electrolyte pH | ~13.5 |
| Housing | Stainless Steel (AISI 316) |
| Ionic Membrane | Cementitious Mortar |
| Input Impedance Requirement | >100 MΩ |
| Compliance | EN 12696:2016, ASTM C876, ISO 15663-2 |
| Installation | Embeddable in Fresh or Existing Concrete |
| Output Interface | Standard BNC or Screw-Terminal Voltage Output |
| Operating Temperature Range | −10 °C to +60 °C |
| Long-Term Drift | < ±2 mV/year (typical, under stable alkaline conditions) |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | FLUIDICAM |
| Viscosity Range | 0.1–200,000 cP |
| Shear Rate Range | 100–1.8×10⁵ s⁻¹ |
| Temperature Control Range | 4–80 °C |
| Compliance | Designed for GLP/GMP-relevant workflows with audit-trail-capable software logging |
| Brand | Formulaction (Microtrac Group) |
|---|---|
| Origin | France |
| Model | RHEOLASER MASTER |
| Light Source | 650 nm laser |
| Detection Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Detection Mode | Backscattered light |
| Detector | Dedicated CCD camera |
| Sample Cell | 20 mL standard glass vial (optional 4 mL) |
| Sample Capacity | 6-position automated sample tray |
| Temperature Control Range | +5 °C to 90 °C above ambient (optional up to 150 °C) |
| Temperature Stability | ±0.1 °C |
| Frequency Range (Viscoelastic Spectrum) | 10⁻⁴ Hz to 50 Hz (sample-dependent) |
| Measured Particle RMS Displacement Range | 0.1 nm – 100 nm |
| Compliance | Designed for GLP/GMP environments |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | Rheolaser Master |
| Instrument Type | Optical Microrheometer |
| Sample State | Liquid |
| Measurement Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Temperature Range | +5°C above ambient to 90°C (optional up to 150°C) |
| Frequency Range | 10⁻⁴ Hz to 10² Hz |
| RMS Particle Displacement Range | 0.1 nm – 100 nm |
| Minimum Detectable Particle Size | 50 nm |
| Maximum Solid Volume Concentration | 90% v/v |
| Torque Specifications | Not applicable (non-mechanical, optical measurement) |
| Data Acquisition | High-resolution CMOS camera-based speckle image analysis |
| Sample Holder | 20 mL borosilicate glass cuvette with 6-position sample carousel |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | Turbiscan AGS |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | up to 95% v/v |
| Temperature Control | 25–60 °C (±0.5 °C) |
| Sample Capacity | 54 positions (3 × 18-well thermostated modules) |
| Scan Resolution | 40 µm along 55 mm height |
| Scan Interval | as low as 20 s per scan |
| Light Source | Pulsed NIR LED (880 nm) |
| Detectors | Synchronized transmission and backscattering photodiodes |
| Compliance | ASTM D7809, ISO 13321, USP <729>, GLP-ready data audit trail |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Measurement Principle | Static Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Temp. Range | +5 °C above ambient to 60 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Detectors | Dual photodiode (transmission + backscattering) |
| Sample Cell | Cylindrical glass cell (Ø 27.5 mm × H 55 mm), threaded black cap with butyl/PTFE seal |
| Data Acquisition Modes | Full-height scanning (1 scan/20 s) or fixed-position kinetics (1 measurement/s) |
| Max. Scan Programs | 250 |
| Software Output | BS/T vs. time, layer thickness vs. time, particle migration velocity, hydrodynamic diameter (d), volume fraction (φ), mean free path, TSI Stability Index, dispersion index |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TMIX |
| Light Source | 880 nm NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Interval | 20 s |
| Compliance | Designed for GLP-compliant stability assessment |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Detection Principle | Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Sample Capacity | 6 positions |
| Temperature Range | 4–80 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm per data point |
| Scan Interval | ≥20 s (user-configurable) |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Measurement Modes | Transmission (T) and Backscattering (BS) |
| Software Compliance | FDA 21 CFR Part 11 ready, audit trail enabled, GLP/GMP-supportive workflows |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TRI-LAB |
| Light Source | 880 nm NIR LED |
| Sample Volume | 1.5–30 mL |
| Temperature Range | 20–60 °C |
| Sample Capacity | 1–3 positions |
| Concentration Range | 0.0001–95% v/v |
| Measurement Principle | Static Multiple Light Scattering (SMLS) |
| Detection Modes | Simultaneous Transmitted (T) and Backscattered (BS) Light |
| Output Metrics | Turbiscan Stability Index (TSI), Migration Rate, Phase Thickness, Kinetic Index, Mean Hydrodynamic Diameter, Dispersion Ratio, Redispersion Efficiency |
| Brand | FoShan TST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARC Series |
| Pricing | Available Upon Request |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Temperature Range | RT+100°C to 125°C |
| Humidity Range | 75–100% RH (saturated steam) |
| Temperature Uniformity | ±0.5°C |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±1% RH |
| Temperature Resolution | 0.1°C |
| Pressure Range | 0–2.5 kg/cm² (design burst pressure: 3.5 kg/cm²) |
| Pressure Fluctuation | ±0.02 kg/cm² |
| Pressurization Time | ≤45 min (to 1.04 kg/cm²) |
| Test Condition Reference | 121°C / 100% RH / 1.04 kg/cm² |
| Internal Chamber Dimensions | Φ240 mm × 440 mm (D) |
| Timer Range | 000–999 hours |
| Control System | Microprocessor-based controller with LED display |
| Heating/Cooling Medium | R404A refrigerant |
| Compressor | Tecumseh/Taikang hermetic scroll compressor |
| Noise Level | <60 dB(A) |
| Water Supply | Automatic tap-water filtration and replenishment system |
| Steam Generation | Distilled water recovery and reuse |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, GB/T 2423.3–1993 |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 18 |
| Voltage | 230 V, 1~ |
| Frequency | 50–60 Hz |
| Input Power | 480 W |
| Sieving Method | Dry Sieving |
| Sample Condition | Dry |
| Sieving Range (Dry) | 20 µm – 125 mm |
| Max. Sample Load | 6 kg |
| Sieving Time | 5–60 min |
| Dimensions (W×L×H) | 58 × 58 × 39 cm |
| Net Weight | 92 kg |
| Gross Weight | 129 kg |
| Motor Type | Two maintenance-free asymmetric motors |
| Motion Type | Simultaneous horizontal and vertical oscillation |
| Compliance | ISO 3310-1, ASTM E11-95, ISO 9000 traceable calibration |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 18 |
| Measurement Principle | Dry Mechanical Vibratory Sieving |
| Max. Sample Capacity | 15 kg (standard), up to 25 kg with optional large-diameter sieve stack |
| Sieve Aperture Range | 20 µm – 125 mm |
| Max. Sieve Diameter | 450 mm (18") |
| Sieving Time | 5–60 min |
| Drive System | Dual Asymmetric Counter-Rotating Motors |
| Compliance | ISO 2591-1, ISO 9276-1, ASTM E11, USP <786> |
| Software | AUTOSIEVE v5.x (FDA 21 CFR Part 11 compliant audit trail & user access control) |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 3 |
| Compliance | ISO 3310, ASTM E11, DIN 66165, EN 10204 3.1B |
| Measurement Range (Dry) | 32 µm – 63 mm |
| Measurement Range (Wet) | 20 µm – 10 mm |
| Measurement Range (Micro-fine) | 5 µm – 100 µm |
| Max Sieve Stack (50 mm) | 10 trays |
| Max Sieve Stack (25 mm) | 16 trays |
| Sample Capacity (Dry, <100 µm) | >100 kg |
| Sample Capacity (Dry, <25 mm) | >1 kg |
| Sample Capacity (Wet) | 20–100 g |
| Sample Capacity (Micro-fine) | 0.2–0.5 g |
| Sieving Duration (Dry) | 3–20 min |
| Sieving Duration (Wet) | 3–10 min |
| Sieving Duration (Micro-fine) | 30–60 min |
| Amplitude Display | Digital (mm) |
| Frequency Display | Digital (Hz) |
| Control Interface | RS232 |
| Software | AUTOSIEVE™ |
| IP Rating | IP65 |
| Tension Control | Electronic torque-controlled sieve clamping system |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 3 PRO |
| Dry Sieving Range | 32 µm – 63 mm |
| Wet Sieving Range | 20 µm – 10 mm |
| Micro Sieving Range | 5 µm – 100 µm |
| Sample Capacity (Dry) | <100 g (for <100 µm), <1 kg (for <25 mm) |
| Sample Capacity (Wet) | 20–100 g |
| Sample Capacity (Micro) | 0.2–0.5 g |
| Sieving Time (Dry) | 3–20 min |
| Sieving Time (Wet) | 3–10 min |
| Sieving Time (Micro) | 30–60 min |
| Max. Stackable Sieve Trays | 10 × 50 mm trays or 16 × 25 mm trays |
| Compliance | ISO 3310-1/-2, ASTM E11, DIN 66165, EN 10204 3.1B |
| Software Interface | AUTOSIEVE (PC-connected, GLP-compliant data logging) |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 3 SPARTAN |
| Dry Method Range | 32 µm – 63 mm |
| Wet Method Range | 20 µm – 10 mm |
| Sample Capacity (Dry) | up to 2 kg |
| Sample Capacity (Wet) | 20–100 g |
| Sieving Time (Dry) | 3–20 min |
| Sieving Time (Wet) | 3–10 min |
| Max. Stackable Sieve Trays | 10 × Ø50 mm or 16 × Ø25 mm |
| Sieve Compliance | ISO 3310-1 & ASTM E11 |
| Net Weight | 21 kg |
| Gross Weight | 26 kg |
| Brand | Froilabo |
|---|---|
| Model | Dragon |
| Origin | France |
| Temperature Range | -75 °C to +250 °C |
| Temperature Stability | ≤ 0.5 °C |
| Temperature Transition Rate | 0.03 °C/s to 15 °C/s (both heating and cooling) |
| Airflow Rate | 2.2 L/s to 8.4 L/s |
| Transition Time | -55 °C ↔ +125 °C in 7 s (hot-to-cold) / 14 s (cold-to-hot) |
| Temperature Control Accuracy | ±0.1 °C |
| Operating Modes | Manual, Automatic, Programmable |
| Programmable Steps | Up to 32 per profile |
| Compliance | MIL-STD-883 Method 1010 & 1051, MIL-STD-750 Method 1051, JESD22-A101D |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | ABD0031 |
| Application | Integrated with NBS-type smoke density chamber for aircraft cabin material qualification |
| Core Components | Vacuum chamber, vacuum pump, manual metering pump, gas analysis detector tubes |
| Compliance Context | Airbus ABD0031 specification, ASTM E662, ISO 5659-2, FAA AC 20-135, EN 45545-2 |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | FRP |
| Standards Compliance | EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253, GB/T 11785 |
| Radiation Source | Gas-fired flat-panel radiator inclined at 30° |
| Radiant Heat Flux Range | 1.1–10.9 kW/m² (extendable to 25.0 kW/m²) |
| Critical Radiant Flux Resolution | 0.1 kW/m² |
| Sample Orientation | Horizontal |
| Ignition | Pilot burner with stainless steel nozzle |
| Smoke Measurement | DIN 50055-compliant optical smoke density system mounted on exhaust duct |
| Dimensions (W×D×H) | 1900 × 750 × 1900 mm |
| Construction | Stainless steel hood, calibrated angular positioning plate, dual-access observation door with sliding platform |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | iCone |
| Compliance | ISO 5660-1 & -2, ASTM E1354, ASTM E1740, ASTM F1550, ASTM D5485, ASTM D6113, NFPA 271, NFPA 264, CAN/ULC-S135, BS 476-15, GB/T 16172 |
| Heat Flux Range | Up to 100 kW/m² |
| Sample Size | 100 mm × 100 mm (max thickness 50 mm) |
| Mass Loss Resolution | 0.01 g |
| Exhaust Flow Rate | 24 L/s |
| Oxygen Analysis | Paramagnetic or Zirconia-based O₂ sensor |
| Smoke Obscuration | He–Ne laser (0.5 mW), Si photodiode detector with ND filters (0.3 & 0.8) |
| Ignition Source | 10 kV spark igniter with auto-positioning and safety cutoff |
| Data Acquisition | Synchronized multi-channel, 100 Hz sampling rate |
| Software | ConeCalc v6.x (Windows-based, multilingual UI) |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | NBS |
| Compliance | ASTM E662, ASTM F814, ISO 5659-2, NFPA 258, BS 6401, GB/T 8323, IMO FTPC Part 2, NES 711 |
| Chamber Dimensions | 914 mm × 914 mm × 610 mm (L×H×W) |
| Radiant Heat Flux Range | 10–50 kW/m² (calibrated at 25 kW/m² ±1 kW/m²) |
| Optical System | 6.5 V Tungsten Lamp + S-4 Spectral Response Photomultiplier Tube (dark current <10⁻⁹ A) |
| Light Beam Transmission Accuracy | 0.01% |
| Optical Density Resolution | 0.01 |
| Mass Loss Measurement Accuracy | ±0.1% |
| Timer Resolution | 0.1 s |
| Cone Heater Power | 2600 W |
| Thermocouples | Dual K-type armored (Cu/Alumel) |
| Heat Flux Meter | Thermopile-based, calibrated to ±1 kW/m² at 25 & 50 kW/m² |
| Ignition | Horizontal single-flame burner (30 mm ±5 mm), spark-ignited without chamber opening |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | Oxygen Bomb Calorimeter |
| Standards Compliance | ISO 1716, ISO 1928, ASTM D240, ASTM D4809, ASTM D5468, ASTM D5865, ASTM E711 |
| Application Scope | Gross Calorific Value (GCV) determination of solid, liquid, and heterogeneous fuels and combustible materials |
| Configuration | Includes main calorimeter unit, high-pressure oxygen bomb assembly, oxygen charging station, calibration accessories (benzoic acid standard, ignition wire, crucibles), and installation kit |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Model | EVO Expert L/R/H |
| Viscosity Range | 20–106,000,000 cP (mPa·s) |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.01–200 rpm |
| Number of Speeds | 54 |
| Compliance | ASTM D1076, D1439, D2196, D2556, D2983, ISO 2555, BS 6075 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Interface | USB 2.0, Wi-Fi (optional), TFT color touchscreen, capacitive touch keypad |
| Data Output | Excel-compatible .csv/.xlsx via FDB software or built-in data logger |
| Calibration | User-accessible viscosity & temperature calibration with PT100 probe |
| Rotors | AISI 316 stainless steel, coded for rapid identification |
| Software | FDB Control Suite (Windows-based), GLP-compliant audit trail, multi-step program storage (up to 9), real-time graphing, shear rate/shear stress calculation (with coaxial rotor geometry) |