Physical Property Testing Instruments
Filter
Showing 4411–4440 of 12427 results
| Brand | inTEST- Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-505 |
| Temperature Shock Range | −20°C to +225°C |
| Temperature Stability | ±1.0°C |
| Heating Rate | 0°C to +125°C in <3 min |
| Cooling Rate | +125°C to 0°C in <4 min |
| Humidity Range | 0–60% RH (45% RH nominal) |
| Temperature Resolution | ±0.1°C |
| Temperature Accuracy | ±1.0°C (NIST-traceable calibration) |
| Supply Air Temperature | +20°C to +28°C (nominal +23°C) |
| Supply Pressure | 5.6–7.0 kg/cm² (80–90 PSIG) |
| Power | 200–250 VAC, 50/60 Hz, 10 A, Single-phase |
| Interface | IEEE-488 & RS-232 |
| Software Support | LabVIEW™ Driver |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-545 |
| High-Temperature Range (°C) | 0 to +225 (50 Hz) |
| Low-Temperature Range (°C) | −75 to 0 (50 Hz) |
| Thermal Shock Range (°C) | −75 to +225 (50 Hz) |
| Temperature Stability | Excellent |
| Ramp Rate (°C/min) | ~10 s for −55 °C to +125 °C |
| Ramp Rate (°C/min) | ~10 s for +125 °C to −55 °C |
| Airflow Output | 4–18 scfm (1.9–8.5 L/s) |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | ±0.1 °C |
| Sensor Type | T- or K-type thermocouple |
| Refrigeration | Auto-cascade, non-ozone-depleting refrigerant, LN₂-free |
| ESD Protection | Integrated patented design |
| Operating Noise | <65 dBA |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ThermoStream ATS-545-M |
| Temperature Range | –80 °C to +225 °C |
| Cooling/Heating Medium | Dry, Filtered Compressed Air |
| Control Interface | Rotary Knob Panel with Real-Time Sensor Feedback |
| Safety Protection | Dual-Stage Over-Temperature Cut-Off (Factory-Set at +230 °C, User-Configurable Limits) |
| Form Factor | Mobile Benchtop Unit Compatible with Robotic Handler Integration |
| Compliance | Designed for ASTM F1876, Telcordia GR-468-CORE, IEC 61300-2-22, and JEDEC JESD22-A104 thermal cycling protocols |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710-M |
| High Temp Range | +225 °C |
| Low Temp Range | −80 °C |
| Thermal Shock Range | −80 °C to +225 °C |
| Temperature Stability | ±1 °C |
| Ramp Rate | ~10 s from −55 °C to +125 °C (or reverse) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Temp Display Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interfaces | IEEE-488, RS232, Ethernet |
| Compliance | NIST-traceable calibration, fluorocarbon-free refrigerant, GLP/GMP-ready data logging |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | inTEST ATS-730E |
| Temperature Range | −85 °C to +225 °C (50 Hz) / −90 °C to +225 °C (60 Hz) |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Transition Rate | −55 °C to +125 °C in ≈10 s |
| Temperature Accuracy | ±1 °C (NIST-traceable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488, RS232, Ethernet |
| Compliance | CE, RoHS, CFC-free |
| Dimensions (W×D×H) | 61.0 × 72.4 × 108.0 cm |
| Net Weight | 236 kg |
| Optional Configurations | Robotic arm, turntable, height-adjustable stand, heated lid, handheld thermal probe |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor (Imported) |
| Model | ATS-750 |
| Price Range | USD 28,000 – 70,000 (FOB) |
| Temperature Range | −85 °C to +300 °C (50 Hz) / −90 °C to +300 °C (60 Hz) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Transition Rate | −55 °C → +125 °C in ~10 s |
| Temperature Stability | ±0.01 °C |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488 (GPIB), RS-232, Ethernet |
| Operating Modes | Air Mode & DUT Mode |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (via optional audit trail software), GLP/GMP-ready |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-560 |
| High Temperature Range | +200 °C |
| Low Temperature Range | −60 °C |
| Thermal Shock Range | −60 °C to +200 °C |
| Frequency | 50/60 Hz |
| Temperature Stability | ±0.01 °C |
| Ramp Rate (Heating) | −40 °C to +150 °C in <15 s |
| Ramp Rate (Cooling) | +125 °C to −40 °C in <35 s |
| Airflow Output | 4–18 SCFM (1.9–8.5 L/s) |
| Temperature Display Resolution | ±0.1 °C |
| Temperature Accuracy | ±1.0 °C (NIST-traceable calibration) |
| DUT Temperature Control | Proprietary closed-loop algorithm with direct DUT sensing |
| Thermocouple Inputs | Type T & K |
| Power Supply | 200–250 VAC, 50/60 Hz, 30 A (1-phase, 230 V nominal) |
| Operating Ambient | 20–28 °C (23 °C nominal), 0–60% RH (45% rated) |
| Dimensions (W×D×H) | 46.4 × 66.7 × 142.2 cm |
| Weight (Unit) | 181 kg |
| Weight (Packed) | 227 kg |
| Acoustic Noise | <57 dBA |
| Brand | inTEST- Temptronic |
|---|---|
| Origin | USA |
| Model | ECO-710 |
| Temperature Range (°C) | -80 to +225 |
| Temperature Stability (°C) | ±0.01 |
| Transition Time (°C) | +125 to −55°C in ~10 s |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Temperature Accuracy | ±1°C |
| Temperature Resolution | 0.1°C |
| Noise Level | ≤56 dBA |
| Input Power | 20 A |
| Refrigerant | Non-ozone-depleting, non-flammable HFC blend |
| Compliance | RoHS, CE, UL 61010-1, IEC 61000-6-3 |
| Brand | inTEST-Temptronic |
|---|---|
| Origin | USA |
| Model | ATS-710-M |
| Temperature Range | -80 °C to +225 °C |
| Ramp Rate | Up to 18 °C/s |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Operating Modes | Air Mode & DUT Mode |
| Compliance | NIST-traceable calibration, supports GLP/GMP-relevant audit trails |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IEC 60529, ISO 20653, SAE J575, GB/T 4208 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Origin Region | Netherlands |
| Model | IP2000 |
| Pricing | Upon Request |
| Standards Compliance | ISO 6272, ASTM D2794 |
| Optional Accessories | 1 kg and 2 kg Additional Weights |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| IP Rating Coverage | IPX5, IPX6, IPX7 |
| Compliance Standards | IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810H Method 506.7, GJB 150.8A, IEC 60068-2-68, GB/T 2423.38, IEC 60034-5, GB/T 4942.1 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IPHTA |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Brinell Hardness Tester |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IPHTq |
| Price | USD 300 |
| Instrument Type | Shore/Barcol Hardness Tester |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IPX5, IPX6 per IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810G Method 512.6, ASTM D7706 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,500 (FOB) |
| Compliance Standards | IEC 60529, ISO 20653, GB/T 4208, GJB 150.8, IEC 60068-2-68, GB 2423.38 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR 400KA |
| Pricing | Available Upon Request |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | IR-2 |
| Pricing | Available Upon Request |
| Measurement Bands | 3–5 µm, 8–14 µm, 1–22 µm |
| Emissivity Range | 0.100–0.990 |
| NEΔε (Noise-Equivalent Emissivity Change) | 0.001 |
| Accuracy | ±0.02 (for ε > 0.50) |
| Repeatability | ±0.01 |
| Sample Temp. Range | Ambient to 300 °C (optional heated stage) |
| Max. Sample Diameter | 50 mm |
| Measurement Time | < 3 s after trigger |
| Display Resolution | 0.001 (LED) |
| Power Supply | AC 220 V, 50 Hz |
| Interface | RS-232 serial port |
| Optical Method | Normal-incidence reflectance-based emissivity derivation using calibrated blackbody source |
| Brand | IREA TECH |
|---|---|
| Origin | USA |
| Model | IREA TECH - HAST |
| Chamber Type | Upright |
| Certification | KOSHA Pressure Vessel Safety Approval |
| Compliance | Meets requirements for JEDEC JESD22-A110 and JESD22-A108 accelerated reliability testing |
| Humidity Range | 85–100% RH (at elevated temperature/pressure) |
| Temperature Range | 100–130°C (saturated steam environment) |
| Test Acceleration Factor | ≥10× vs. conventional THB (Temperature-Humidity-Bias) testing |
| Water Supply | Integrated auto-fill system with dual-level water detection |
| Chamber Construction | Stainless steel 316 inner chamber, reinforced pressure-rated enclosure |
| Optional Features | Anti-fog heated viewing window, internal LED lighting, pass-through ports (50 mm standard, up to 100 mm available), internal access door |
| Brand | Irian |
|---|---|
| Origin | France |
| Model | J2 |
| Pressure Range | 0–14,500 psi |
| Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Pressure Uncertainty | ±1.5 psi |
| Cell Volume | 1.24 mL |
| Optical Imaging | Integrated HD Digital Camera |
| Actuation | Embedded Electromechanical Piston Pump with Automatic Valving |
| Gas Flow Control | Micro-Flow Regulating Valve |
| Cell Tilt | 0–45° |
| Dimensions | 610 mm × 559 mm × 203 mm (L×W×H) |
| Cooling | High-Capacity Forced-Air System |
| Agitation | Electromagnetic Vibration Module |
| Temperature Range | -125–1200°C |
|---|---|
| Heating Rate | 0.1–40°C/min |
| Max Sample Mass | 0.4 g |
| Balance Resolution | 0.1 µg |
| Temperature Range | –125 to 1500 °C |
|---|---|
| Heating Rate | 0.1–40 °C/min |
| Max Sample Mass | 0.4 g |
| Balance Resolution | 0.1 µg |
| Furnace Options | 650 °C / 1200 °C / 1500 °C |
| DSC/DTA Mode | Yes |
| Gas Control | Dual- or Quad-channel purge system |
| Software | Infinity Pro Thermal Analysis Suite |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | STA 650 |
| Temperature Range | –125 to 650 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 400 mg |
| Balance Resolution | 0.1 µg |
| Software | Infinity Pro Thermal Analysis Suite |
| Brand | ISI |
|---|---|
| Origin | USA |
| Model | TMA 800 |
| Temperature Range | -90°C to 800°C |
| Temperature Accuracy | ±1°C |
| Temperature Precision | ±1°C |
| Cooling Options | Mechanical refrigeration, water cooling |
| Test Modes | Expansion, Compression, Tension, Penetration, 3-Point Bending |
| Maximum Load Force | 2 N |
| Displacement Sensor | High-sensitivity LVDT |
| Furnace Design | All-metal, vertical inline architecture with Archimedes suspension system |
| Sample Height Range | Micrometer-scale to >10 mm |
| Uniform Temperature Zone Height | 40 mm |
| [Brand | Isida |
|---|---|
| Origin | Guangdong, China |
| Model | XK22 |
| Resolution | 0.70–5.20 µm/pixel |
| Optical Magnification | 1.4×–9× (continuously adjustable) |
| Electronic Magnification | 50× |
| Light Source | Adjustable LED ring light + red laser diode (LD) positioning |
| CCD | High-sensitivity color CCD |
| Maximum PCB width | 780 mm (30") |
| Field of View | 3.4 mm × 2.5 mm to 0.53 mm × 0.4 mm |
| Repeatability | ±1 µm |
| Dimensions (L×W×H, instrument only) | 960 mm × 700 mm × 1220 mm |
| Weight (instrument only) | 145 kg |
| Power | 220 V ±10%, 50 Hz, 10 A |
| Operating Temperature | 0–40 °C] |
| Brand | MOTIS |
|---|---|
| Model | 5659-2 |
| Conical Heater Heat Flux Range | 10–70 kW/m² |
| Shield Shutter | Motorized Radiation Blocker for Pre-Test Isolation |
| Compliance | ISO 5659-2 (Fire Tests — Reaction to Fire Tests — Part 2: Room/Corner Test) |
| Origin | Jiangsu, China |
| Distribution Type | Authorized Distributor |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ISO 9150 |
| Pricing | Available Upon Request |