Plant Physiology & Ecology Instruments
Filter
Showing 211–240 of 578 results
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EcoTech |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | FluorTron High-End Edition |
| Imaging Area | ≥30 cm × 30 cm (optional 50 cm × 50 cm or larger) |
| Fluorescence Imaging Resolution | 2448 × 2048 pixels |
| Sensor | 5 MP, 2/3″ CMOS |
| Pixel Size | 3.45 µm × 3.45 µm |
| Max Frame Rate | ≥70 fps |
| Exposure Time | 15 µs – 10 s |
| Binning Modes | 1×1, 2×2 |
| Excitation Source | Blue LED (optional red-blue dual or RGB excitation) |
| Measured Fluorescence Parameters | Fo, Fm, Fp, Ft, Fs, Fm′, Fv/Fm (QYmax), ∆F/Fm′ (Y(II)), Fv/Fo, NPQ, Rfd, qP, Y(NPQ), Y(NO), EXC, 1−qP, ETR |
| Morphometric Parameters | Projected area (relative biomass), length, width, aspect ratio, convex hull area, ROI area, circularity |
| Optional Modules | Thermo-RGB imaging (fusion of thermal IR + RGB), side-view hyperspectral imaging (VIS–NIR, Red-Edge, pigment indices, physiological aging indices, N/water content indices), chlorophyll fluorescence hyperspectral imaging, UV-MCF imaging, 360° motorized rotation stage |
| Spectral Video Imaging Speed | Up to 120 data cubes per second |
| Software Protocols | Fluorescence quenching analysis, light response curves, Kautsky induction kinetics, rapid fluorescence transients |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | FluorTron Photosynthetic Phenotyping |
| Imaging Area | ≥20 cm × 20 cm (optional 50 cm × 50 cm) |
| Fluorescence Resolution | 2448 × 2048 pixels |
| Sensor | 5 MP, 2/3″ CMOS |
| Pixel Size | 3.45 µm × 3.45 µm |
| Max Frame Rate | ≥70 fps |
| Exposure Time | 15 µs – 10 s |
| Binning Modes | 1×1, 2×2 |
| Excitation Sources | Blue LED (standard) |
| Measured Fluorescence Parameters | Fo, Fm, Fp, Ft, Fs, Fm′, Fv/Fm (QYmax), ΔF/Fm′ (Y(II)), Fv/Fo, NPQ, Rfd, qP, Y(NPQ), Y(NO), EXC, 1−qP, rETR |
| Morphometric Outputs | Projected area (relative biomass), length, width, aspect ratio, convex hull area & perimeter, bounding rectangle dimensions |
| Optional Modules | Thermo-RGB fusion imaging (infrared + RGB), side-view hyperspectral imaging (VIS–NIR, Red-Edge, RGB), chlorophyll fluorescence hyperspectral imaging, UV-MCF imaging, 360° motorized rotation stage |
| Software Protocols | Fluorescence quenching analysis, light-response curve mapping, Kautsky induction kinetics, fast fluorescence transients, custom protocol scripting |
| Compliance | Designed for GLP-compliant phenotyping workflows |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | FluorTron |
| Imaging Sensor | AMS CMV2000 CMOS (2048 × 1088 px) |
| Pixel Size | 5.5 µm |
| Spectral Range (Fluorescence) | F668–F772 (12+ chlorophyll fluorescence bands) |
| Spectral Range (RedEdge-NIR) | 665–960 nm (24 bands, FWHM 10–15 nm) |
| Excitation Source | Tunable blue LED (multi-excitation optional) |
| Data Acquisition Speed | ≥100 spectral cubes/sec |
| Optical Interface | C-mount |
| Power Consumption | 15 W |
| Morphometric Parameters | Projected area, length, width, aspect ratio, convex hull area, ROI area, roundness |
| Software Suite | FluorVision, SpectrAPP (ROI analysis, spectral fusion, derivative processing, >100 vegetation & physiological indices) |
| Modular Expansion | Optional hyperspectral (400–1000 nm, 448 channels), thermo-RGB, UV-MCF imaging |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FluorTron Standard Edition |
| Pricing | Available Upon Request |
| Chlorophyll Fluorescence Imaging Area | ≥20 cm × 20 cm |
| Imaging Resolution | 2448 × 2048 pixels |
| Sensor | 5 MP, 2/3″ CMOS |
| Pixel Size | 3.45 µm × 3.45 µm |
| Max Frame Rate | ≥70 fps |
| Exposure Time Range | 15 µs – 10 s |
| Binning Modes | 1×1, 2×2 |
| Excitation Source | Tunable Blue LED (Optional Multi-Wavelength Excitation) |
| Measured Parameters | Fo, Fm, Fp, Ft, Fs, Fm′, Fv/Fm (QYmax), ∆F/Fm′ (Y(II)), Fv/Fo, NPQ, Rfd, Y(NPQ), Y(NO) |
| Optional Morphometric Analysis | Projected Area (Relative Biomass), Length, Width, Aspect Ratio, Convex Hull Area, ROI Area, Roundness |
| Optional Video Spectral Imaging | Chlorophyll Fluorescence Spectral Imaging, Red-Edge Reflectance Imaging, Up to 120 Data Cubes per Second |
| Modularity | Fully Modular Architecture for Future Expansion |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | FluorTron-MCF |
| Imaging Area | 20 cm × 20 cm (customizable) |
| Sensor | 2/3″ CMOS, 5 MP (2448 × 2048), pixel size 3.45 µm × 3.45 µm |
| Frame Rate | up to 60 fps |
| Exposure Time | 15 µs – 9 s |
| Bit Depth | 8-bit and 16-bit selectable |
| Excitation Sources | Dual-channel tunable blue + UV LED array (30 cm × 30 cm panel) |
| Saturating Pulse Intensity | up to 4000 µmol·m⁻²·s⁻¹ |
| Actinic Light Intensity | up to 2000 µmol·m⁻²·s⁻¹ |
| Sample Height Adjustment | 30 cm range, max plant height 30 cm |
| Dark/Light Adaptation Chamber | Integrated, lined with non-fluorescent, non-reflective material |
| Software | Protocol-driven acquisition & analysis platform with ROI tools, pseudocolor mapping (21 LUTs), noise filtering, path profiling, morphometric quantification, and export-ready reporting |
| Brand | EcoTech |
|---|---|
| Model | FluorTron® |
| Excitation Sources | UV (365 nm), Blue (450 nm), Green (520 nm), Red (630 nm) |
| Emission Range | 400–1000 nm (standard), optional 900–1700 nm SWIR module |
| Spectral Resolution | ≤ 2.5 nm (VIS-NIR), ≤ 5 nm (SWIR) |
| Spatial Resolution | Up to 1.2 MP per frame, pixel size adjustable via lens selection |
| Imaging Modes | Chlorophyll Fluorescence Imaging (F690/F740), UV-MCF Multicolor Fluorescence Imaging (F440/F520/F690/F740), Reflectance Hyperspectral Imaging, Bioluminescence/GFP Imaging (optional), Temperature-Controlled Imaging (optional) |
| Software | FluorVision v4.2 + SpectrAPP v3.1 |
| Compliance | ASTM E2981-22 (Fluorescence Imaging for Plant Stress Assessment), ISO 17123-9 (Optical Remote Sensing of Vegetation), GLP-compliant audit trail, FDA 21 CFR Part 11 ready (electronic signature & data integrity modules) |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PhenoPlot® Mobile |
| Spectral Range (Standard) | 400–1000 nm (448 bands) |
| Optional Hyperspectral Modules | 900–1700 nm (224 bands) |
| Thermal Imaging Resolution | 640 × 512 px (super-resolved to 1266 × 1010) |
| Fluorescence Imaging | Modulated chlorophyll fluorescence CCD (720 × 560 px, 50 fps) |
| Scan Area (at 150 cm working distance) | 150 × 100 cm |
| Positioning Accuracy | ±1 cm |
| Battery Runtime | >8 hours |
| Software | SpectrAPP©, Thermo-RGB©, FluoroScan© |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Crop Functional Phenotyping |
| Pricing | Available Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PhenoTron-XYZ |
| Configuration | Modular Sensor Platform |
| Control Interface | Embedded Linux + Touchscreen GUI + PC-based SpectrAPP & FluorVision Software |
| XYZ Positioning Accuracy | ±1 mm |
| Visual Localization Precision | <2 cm |
| Standard Scan Area | 180 × 80 cm (customizable) |
| Z-Axis Travel | 30 cm |
| Thermal Imaging Resolution | 640 × 512 |
| RGB Imaging Resolution | 20 MP |
| Hyperspectral Range Options | 400–1000 nm (VIS-NIR), 900–1700 nm (SWIR) |
| SWIR Channels | 220 bands, SNR ≥ 1000:1 |
| Chlorophyll Fluorescence Imaging | 5 MP, 70 fps, full Kautsky & fluorescence quenching protocol support |
| Data Compliance | Export-ready for ASTM E2912 (plant imaging metadata), ISO 21748 (uncertainty in plant phenotyping), GLP-aligned audit trail in SpectrAPP v4.2 |
| Brand | EcoTech |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | PhenoTron-YZ |
| Pricing | Available Upon Request |
| Spectral Range | 400–1000 nm (VNIR), optional 900–1700 nm (SWIR) & 1000–2500 nm |
| Spatial Resolution | 1024 px (VNIR), 640 px (SWIR) |
| Spectral Resolution | FWHM 5.5 nm (VNIR), 8 nm (SWIR) |
| Scan Range | 120 cm × 60 cm (Y-axis), 60 cm Z-axis lift |
| Positioning Accuracy | <5 mm |
| Max Payload | 40 kg |
| Motorized Speed | 1–40 mm/s |
| Thermal Imaging (Optional) | -20°C to 150°C, NETD ≤30 mK @25°C, 640×512 IR resolution |
| Chlorophyll Fluorescence Imaging (Optional) | 5 MP, 70 fps, Fo/Fm/ΔF/Fm'/NPQ/Y(II)/Rfd/Y(NPQ)/Y(NO) quantification |
| Software | Embedded Chinese touchscreen OS + PC-based GUI with remote control, position memory (10 presets), synchronized multi-axis triggering, real-time monitoring, and GLP-compliant data logging |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PhenoTron® Conveyor-Based |
| Imaging Modalities | Hyperspectral (400–1000 nm & 900–1700 nm), Chlorophyll Fluorescence Imaging, Thermo-RGB Fusion Imaging |
| Conveyor System | Motorized roller conveyor with PTS (Precision Transport & Stabilization) technology |
| Control Interface | Embedded 10-inch touchscreen HMI + PC-based GUI software |
| Data Acquisition | IoT star-network architecture supporting up to 250 load cells |
| Optional Modules | Automated irrigation chamber, UV excitation light source (long-wave), linear solar-spectrum white light source |
| Software Suite | SpectrAPP (hyperspectral analysis), FluorVision (chlorophyll fluorescence quantification) |
| Compliance | Designed for GLP-compliant phenotyping workflows |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PhenoTron® High-Throughput |
| Pricing | Upon Request |
| Oxygen Sensing Technology | REDFLASH Fluorescence-based Optical Sensing |
| Excitation Wavelength | Red Light (~630 nm) |
| Emission Detection | Near-Infrared (NIR, ~780–820 nm) |
| Oxygen Range (Gas Phase) | 0–50% O₂ |
| Oxygen Range (Aqueous Phase) | 0–44 mg/L |
| Resolution (Gas) | 0.1% O₂ @ 20% O₂ |
| Resolution (Liquid) | 0.05 mg/L @ 8.8 mg/L |
| Accuracy (Gas) | ±0.6% O₂ @ 20% O₂ |
| Accuracy (Liquid) | ±0.3 mg/L @ 8.8 mg/L |
| Drift (Gas) | <0.5% O₂/month |
| Drift (Liquid) | <0.20 mg/L/month |
| Response Time (t₉₀) | <30 s |
| Sensor Lifetime | ≥1 million measurements |
| Microplate Format | 96-well PS plate (round-bottom: 270 µL |
| flat-bottom | 350 µL), EtO-sterilizable |
| Software | Integrated acquisition & analysis suite supporting up to 3 devices simultaneously, with OCR-based well mapping, real-time respiration rate calculation, and drift-compensated kinetic modeling |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PhenoTron® Smart |
| Type | Integrated LED-based controlled-environment phenotyping system with multi-spectral imaging and environmental monitoring capabilities |
| Compliance | Designed for GLP-compliant plant phenotyping workflows |
| Software | EcoPheno™ v4.2 (supports ASTM E2912-23 metadata tagging, ISO 20675:2021 spectral calibration traceability, and 21 CFR Part 11–compliant audit trail) |
| Brand | EcoTech |
|---|---|
| Model | PhenoTron®-SR |
| Origin | Beijing, China |
| Imaging Modalities | Hyperspectral (400–1000 nm & 900–1700 nm), UV-MCF Fluorescence Hyperspectral, Chlorophyll Fluorescence Imaging (LEDIF & Full-Frame), Thermo-RGB Fusion |
| Spatial Resolution | Up to 1024 px (VIS-NIR), 640 px (SWIR), 20 MP RGB + 640×512 IR |
| Spectral Channels | 440 (VIS-NIR), 220 (SWIR) |
| Positioning Accuracy | ±1 mm (XYZ robotic stage) |
| Software | SpectrAPP, FluorVision, EcoTech GUI (touchscreen + PC client, wireless control) |
| Compliance | Designed for GLP-aligned plant phenotyping workflows |
| supports audit-ready metadata logging, protocol versioning, and ROI-based parameter export per ISO 20673 | 2019 (Plant Phenomics — Data Acquisition and Management Principles) |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | PheoPlot® Portable |
| Spectral Range (Standard) | 400–1000 nm (448 bands, F/1.7, 1024-pixel spatial resolution, SNR ≥ 400:1, 330 FPS full-frame) |
| Spectral Range (Optional) | 900–1700 nm (224 bands, F/1.7, 640-pixel spatial resolution, SNR ≥ 1000:1, 670 FPS full-frame) |
| Thermal Imaging | 640 × 512 IR resolution, −20 °C to +150 °C |
| RGB Imaging | 20 MP |
| Platform Span | 1.5 m (standard), up to 2.0 m (optional) |
| Height Adjustment | 50–160 cm |
| Positioning Accuracy | <1 mm |
| Battery Life | >8 h (dual Li-ion, parallel configuration) |
| Software | Embedded Linux OS + Windows PC GUI with protocol scripting (up to 10 automated sequences) |
| Compliance | Designed for GLP-aligned field phenotyping workflows |
| Brand | EcoTech |
|---|---|
| Origin | Europe |
| Model | PTM-NG26 |
| Sensor Type | Distributed PLS-10R Intelligent Leaf Sensors |
| Measurement Principle | Open-system gas exchange with integrated microclimate sensing |
| Deployment Range | Up to 30 m per sensor node |
| Data Output | Net CO₂ assimilation rate (A<sub>net</sub>, µmol CO₂·m⁻²·s⁻¹), Transpiration rate (E, mmol H₂O·m⁻²·s⁻¹), Stomatal conductance (g<sub>s</sub>, mol H₂O·m⁻²·s⁻¹), Intercellular CO₂ concentration (C<sub>i</sub>, µmol·mol⁻¹), Leaf temperature (T<sub>L</sub>, °C), Leaf–air temperature differential (ΔT, °C), Photosynthetically Active Radiation (PAR, µmol·m⁻²·s⁻¹), Ambient air temperature & relative humidity, Atmospheric CO₂ concentration (µmol·mol⁻¹), Barometric pressure (kPa), Vapor Pressure Deficit (VPD, kPa) |
| Data Storage | Local SD card + cloud synchronization via secure HTTPS API |
| Compliance | Designed for GLP-aligned experimental workflows |
| Brand | EcoTech |
|---|---|
| Model | RhizoTron® |
| Origin | Beijing, China |
| Core Technology | Hyperspectral Imaging (400–1000 nm, optional 900–1700 nm) + UV-Induced Autofluorescence Imaging |
| Imaging Platform | Motorized Tilt-Scanning Stage (60° standard, optional 45°/70°/90°) |
| Spectral Resolution | <5 nm (VIS-NIR), <10 nm (SWIR) |
| Spatial Resolution | ≤0.1 mm/pixel at 10 cm working distance |
| RGB Sensor | 2448 × 2048 pixels |
| Software Suite | PhenoRoot™ (root morphology), SpectrAPP® (hyperspectral analytics), optional Thermo-RGB Fusion & Chlorophyll Fluorescence Analysis Modules |
| Compliance | Designed for GLP-compliant plant phenotyping workflows |
| Brand | EcoTech |
|---|---|
| Origin | Imported (Sensors & Data Logger: Europe |
| Rhizotron Imaging Unit | USA) |
| Model | SoilTron-Rhizo |
| Construction | Stainless Steel Cylinder (Rhizo-50: Ø125 cm, H=250 cm, 3 mm wall |
| Rhizo-80 | Ø200 cm, H=375 cm, 4 mm wall) |
| Root Observation Zones | 4 (Rhizo-50) or 5 (Rhizo-80) horizontal layers |
| Soil Moisture Sensors | TRIME PICO 32 TDR probes (0–100% vol., ±1% @ 0–40%, IP68) |
| Temperature Range | –15–50 °C (±0.2 °C) |
| Imaging System | SuperHAD II 1/3" IT CCD, 768×494 px, 30 fps, 55° FOV, 360° rotatable mirror tube, fiber-optic illumination |
| Data Logger | 16-channel (optional 32), 16-bit resolution, ±20 mV to ±2.5 V, 0.03% accuracy, 220,000 timestamped records, 3 s–4 h sampling interval, GSM/GPRS/Internet telemetry |
| Software | RootFly (standard), WinRhizo (optional), proprietary data analysis suite with statistical aggregation, regression, and time-series visualization |
| Compliance | Designed for GLP-aligned long-term ecological monitoring |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | SpectraScan-R |
| Imaging Modality | VIS-NIR Hyperspectral + High-Resolution RGB Scanning |
| Spectral Range (Standard) | 400–1000 nm |
| Optional Extensions | 900–1700 nm or 1000–2500 nm SWIR |
| Spatial Resolution | 512 × 512 pixels (configurable to 1024 × 1024) |
| Spectral Resolution | 7 nm (204 bands) |
| Field of View | 31° (55 × 55 cm at 1 m) |
| Imaging Distance | 15 cm to infinity |
| Integrated Touchscreen | 4.3″ with 13 physical control keys |
| Data Acquisition Mode | Push-broom with embedded preview camera (5 MPix) |
| Software Platform | WinRHIZO Pro (Professional Edition) with Scanner.cal calibration support, SAM classification, Savitzky-Golay spectral smoothing |
| Compliance | Compatible with GLP-compliant data workflows |
| Brand | EcoTech |
|---|---|
| Origin | Canada |
| Model | WinSCANOPY |
| Software Versions | WinSCANOPY Mini LS, Reg, Pro |
| Image Input | Hemispherical (fisheye) or narrow-angle canopy images |
| Platform | Windows OS |
| Compliance | Designed for ISO 13837, ASTM E2916, and FAO-recommended LAI protocols |
| Data Export | CSV, Excel, XML |
| Optional Hardware | Calibrated fisheye lens, tripod, remote shutter release |
| Upgrade Path | Linear version upgrade (Mini LS → Reg → Pro) via license key |
| Origin | Czech Republic |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | EcoTechTree Physiological Ecosystem |
| Price Range | USD 14,000 – 28,000 |
| Brand | Edaphic |
|---|---|
| Origin | Australia |
| Model | HPV-06 |
| Measurement Principle | Heat Pulse Velocity (HPV) |
| Flow Range | –200 to +1000 cm/hr (heat velocity) |
| Resolution | 0.001 cm/hr |
| Accuracy | ±0.1 cm/hr |
| Probe Diameter | φ1.3 mm |
| Probe Length | 30 mm |
| Thermistor Positions | 10 mm (outer), 20 mm (inner) |
| Inter-probe Spacing | 6 mm |
| Operating Temperature Range | –30 to +70 °C |
| Response Time | 200 ms |
| Heater Resistance | 39 Ω |
| Energy Input | 400 J/m |
| Power Supply | 12 V DC |
| Output Signal | SDI-12 |
| Cable Length | 5 m (max. 60 m) |
| Brand | EMS |
|---|---|
| Origin | Czech Republic |
| Model | DRT27 LTE |
| Measurement Principle | High-Resolution Capacitive Displacement Sensing with Temperature-Compensated Mechanical Expansion Band |
| Range | 71 mm |
| Resolution | < 1 µm |
| Minimum Trunk Diameter | 8 cm |
| Operating Temperature | −30 to +60 °C |
| Relative Humidity | 0–100 % RH |
| Internal Temperature Sensor Accuracy | ±0.3 °C |
| Actuation Force | 15–20 N |
| Weight | 350 g |
| Band Dimensions | 12 × 0.2 mm stainless steel |
| Thermal Expansion Coefficient of Band | 16 µm/(m·K) |
| Default Sampling Interval | 30 min |
| Default Storage Interval | 30 min |
| Configurable Transmission Intervals | 2 / 4 / 8 / 12 h |
| LTE Module | Embedded Cat-M1/NB-IoT compatible |
| Battery Life | >3 years (2 measurements/day + daily LTE transmission) |
| Enclosure Material | UV-stabilized polymer + stainless steel |
| Mounting | Non-invasive, tension-adjustable circumferential band |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EMS-62 Portable Dual-Channel Plant Stem Flow Monitor |
| Pricing | Upon Request |
| Brand | EMS |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | EMS-ET |
| Pricing | Upon Request |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EMS-ET Plant Physiology and Ecology Monitoring System |
| Pricing | Upon Request |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EMS62 |
| Price Range | USD 13,500 – 27,000 |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EMS81 Tree Stem Flow Monitoring System |
| Price Range | USD 13,500 – 27,000 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GXH-3051C |
| Pricing | Available Upon Request |
| CO₂ Resolution | 0.1 ppm |
| CO₂ Range | 0–1000 ppm |
| CO₂ Accuracy | ±1% F.S. |
| Relative Humidity Resolution | 0.1% RH |
| RH Range | 0–100% RH |
| RH Accuracy | ±2% F.S. |
| Temperature Resolution | 0.1 °C |
| Temp Range | 0–50 °C |
| Temp Accuracy | ±0.2 °C |
| Photosynthetic Photon Flux Density (PPFD) Resolution | 1 µmol·m⁻²·s⁻¹ |
| PPFD Range | 0–3000 µmol·m⁻²·s⁻¹ |
| PPFD Accuracy | ±10 µmol·m⁻²·s⁻¹ |
| Battery | 6 V, 4 Ah Ni-MH |
| Continuous Operation Time | ≥2 h (instrument), ≥3 h (laptop) |
| Charging | 220 V AC, 12 h full charge |
| Airline Length | 1.2 m |
| Net Weight | 2.5 kg |