Showing 181–210 of 578 results
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YMJ-S |
| Width Range | 0–155 mm |
| Length Range | 0–2000 mm |
| Scanning Area | 220 × 300 mm |
| Optical Resolution | 4800 dpi |
| Area Resolution | 0.001 cm² |
| Length/Width Resolution | 0.01 cm |
| Operating System Compatibility | Windows 7 or later (Windows 10 recommended) |
| Data Export | Excel (.xlsx), CSV, Cloud Platform (charting: bar, line |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Range | 0–4.99 MPa (0–49.9 bar) |
| Accuracy | ±0.01 MPa |
| Display | 4.3″ Color LCD Touchscreen |
| Pressure Chamber Volume | 4 L, Rated Pressure: 12 MPa |
| Data Storage | Up to 9,999 records |
| Power Supply | Rechargeable Battery (24 h @ max brightness) |
| Dimensions (Instrument Box) | 520 × 330 × 206 mm |
| Dimensions (Pressure Chamber Box) | 530 × 420 × 206 mm |
| Net Weight | ~12 kg per box |
| Units | MPa / bar selectable |
| Compliance | Designed for GLP-aligned field and lab use |
| Origin | Czech Republic |
|---|---|
| Type | Imported Instrument |
| Manufacturer Role | Authorized Distributor |
| Model | TL Series (TL200/PMT, TL300/HT, TL400/LT) |
| Temperature Range | –90 °C to +190 °C (model-dependent) |
| Light Source | 8× high-intensity LEDs (λₘₐₓ = 625–630 nm), flash intensity ≥150,000 μmol(photon)·m⁻²·s⁻¹, pulse width 5–10 μs |
| Detection Range | 300–900 nm (PMT-based) |
| Sampling Interval | 100 ms (minimum) |
| Control Precision | ±0.1 °C |
| Software | FluorWin 3.6 |
| Interface | USB |
| Brand | Delta-T Devices |
|---|---|
| Origin | United Kingdom |
| Model | AP4 |
| Measurement Principle | Steady-state diffusion-based porometry |
| Weight | 3.0 kg (main unit), 130 g (sensor head) |
| Operating Time | Up to 20 h on internal rechargeable battery |
| Data Storage | 1500 readings |
| Interface | RS232 (9600 baud) |
| Compliance | Designed for GLP-aligned field and lab use |
| Software | Windows-compatible CSV export utility |
| Brand | Delta-T Devices |
|---|---|
| Origin | United Kingdom |
| Model | SunScan SS1 |
| Type | Portable PAR-based Canopy Analyzer |
| Sensor | BF5 Diffuse/Global PAR Sensor |
| Data Interface | Wired (SS1-COM) or Wireless (SS1-COM-R4, up to 200 m range) |
| Software | SunData v3.x |
| Compliance | Designed for field-deployable GLP-aligned ecological and agronomic research |
| Brand | Delta-T |
|---|---|
| Origin | United Kingdom |
| Model | EQ3 Equitensiometer |
| Measurement Range | 0 to −1000 kPa (0 to −10 bar) |
| Accuracy | ±10 kPa (0 to −100 kPa) or ±10% of reading (−100 to −1000 kPa) |
| Temperature Accuracy | ±0.5 °C (0–40 °C), ±0.75 °C (−20 to +60 °C) |
| Output | 0–1.0 V (non-linear), thermistor resistance 5.8 Ω to 28 kΩ |
| Power Supply | 5–14 V DC, 18 mA/s |
| IP Rating | IP68 |
| Probe Dimensions | 181 mm × 40.5 mm dia |
| Weight | 0.3 kg |
| Calibration | Individual sensor calibration provided |
| Brand | Delta-T |
|---|---|
| Origin | United Kingdom |
| Model | SM150T |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Soil Moisture Range | 0–0.7 m³·m⁻³ (standard), extendable to 0–1.0 m³·m⁻³ |
| Soil Moisture Accuracy | ±0.03 m³·m⁻³ (±3% vol.) |
| Soil Temperature Range | −20 to +60 °C |
| Temp. Accuracy | ±0.5 °C (0–40 °C), ±0.75 °C (−20 to +60 °C) |
| Electrical Conductivity Tolerance | 50–500 mS·m⁻¹ |
| EC-Induced Error | < ±0.035 m³·m⁻³ (for θ = 0.05–0.4 m³·m⁻³) |
| Output Signal | 0–1.0 V analog |
| Power Supply | 5–14 VDC, 18 mA @ 1 s sampling interval |
| IP Rating | IP68 |
| Operating Temperature | −40 to +70 °C |
| Sensing Volume | Ø70 mm × 55 mm cylinder |
| Probe Dimensions | 51 mm × Ø2.5 mm |
| Mass | 0.1 kg |
| Compatible Loggers | Delta-T GP1, GP2, DL2e, DL6 |
| Brand | METER |
|---|---|
| Origin | Germany (Manufactured by METER Group, formerly UMS) |
| Model | Dendrometer D1 |
| Type | Portable Mechanical Dendrometer |
| Measuring Principle | Linear Circumferential Displacement via Precision Spring-Loaded Band |
| Measurement Range | 10–66 cm stem diameter (extendable via tandem band configuration) |
| Band Material | Astralon® polymer |
| Thermal Expansion Coefficient | 75 × 10⁻⁶ / K |
| Operating Temperature | −30 °C to +60 °C |
| Band Dimensions | 2100 mm × 15 mm × 0.5 mm |
| Tensile Strength | 64 N/mm² |
| Static Friction Coefficient (on dry bark) | 0.5 |
| Band Mass | 16 g |
| Spring Mass | 7 g (short), 14 g (long) |
| Resolution | 0.02 mm (via vernier scale) |
| Compliance | Designed for long-term field deployment in GLP-aligned ecological monitoring |
| Brand | EcoTech |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dualex |
| Pricing | Upon Request |
| Brand | Zealquest |
|---|---|
| Origin | Austria |
| Model | DUALEX |
| Measurement Parameters | Chlorophyll Content (CHL, µg/cm²), Flavonol Index (FLAV), Nitrogen Balance Index (NBI) |
| Measurement Principle | Dual-wavelength transmittance (for CHL) and flavonol-modulated chlorophyll fluorescence shielding (for FLAV) |
| Accuracy | ±5% |
| Reproducibility | 4.5% (CHL), 3.5% (FLAV) |
| Repeatability | 1.3% (CHL), 2% (FLAV) |
| Measurement Area | 19.6 mm² |
| Max Leaf Thickness | 1.5 mm |
| Measurement Time | <1 s |
| Display | LCD with audible feedback |
| GPS | Built-in, positional accuracy <2.5 m |
| Data Storage | 10,000 measurements |
| Output Format | CSV |
| Interface | USB cable |
| Operating Temperature | 5–45 °C |
| Battery | Rechargeable Li-ion, 6 h runtime |
| Weight | 220 g |
| Dimensions | 205 × 65 × 55 mm |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | DEX |
| Measurement Principle | Resistive Strain-Bridge Displacement Sensing with Integrated Temperature Compensation |
| Operating Temperature Range | –10 to 50 °C |
| Accuracy | ±0.050 mm (for ΔT > 20 °C) |
| Temperature Stability | 0.0025 mm/°C |
| Output Signal | Analog ±5 mV or ±2.5 mV (model-dependent) |
| Sensitivity | 0.05–0.5 mV/mm |
| Linearity Error | ±0.004 to ±0.01 mV/mm |
| Electrical Noise | ±0.01 mV |
| Compatible Data Loggers | Supports up to 8 or 32 sensors per system |
| IP-Rated Enclosure | Sealed Electronics for Outdoor & Field Deployment |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | EXO-Skin™ |
| Sensor Type | Heat-Balance-Based Wrap-Around Sap Flow Sensor |
| Diameter Range | 9.5–25 mm |
| Height | 70–120 mm |
| Input Voltage | 4.5 V DC |
| Typical Power Consumption | 0.13–0.48 W |
| Thermocouple Pairs | 2 per unit |
| Enclosure | PTFE-Composite Vapor-Permeable Waterproof Membrane |
| Mounting | Velstretch® Elastic Nylon Band (Breathable, Hydrophobic, Growth-Accommodating) |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | FLGS-TDP |
| Data Logger Memory | 4 MB standard (expandable to 16 GB microSD) |
| Storage Capacity | 400 days at 1-hour interval |
| Input Channels | 32 differential analog inputs |
| Max Probe Support | 128 × TDP10/30/50, 64 × TDP80, or 40 × TDP100 |
| Temperature Accuracy | ±0.03 °C |
| Temperature Resolution | 0.0083 °C |
| AVRD Voltage Regulation | 4 channels (1.5–10 V, 5 A each) |
| System Dimensions | 45 × 35 × 16 cm |
| Weight | 11.5 kg |
| Power Supply | Dual-voltage AC adapter (110–220 V, 50–60 Hz, 4.5 A) |
| Standard Cable Length | 3 m (extendable to 22.8 m) |
| Compliance | Designed for long-term field deployment under GLP-aligned environmental monitoring protocols |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flow32-1K |
| Pricing | Upon Request |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | Flow32-1K |
| Power Supply | 12 V rechargeable lead-acid battery (7 Ah) |
| Data Storage | 4 MB internal (expandable to 16 GB via microSD) |
| Channel Capacity | Up to 32 differential analog input channels |
| Sensor Compatibility | 14 sizes of Dynagage wrap-around stem flow sensors (stem diameter range: 2.1–165 mm) |
| Voltage Regulation | Dual AVRD modules, 1.5–10 V adjustable, 5 A per channel |
| Input Resolution | 0.05–0.88 µV |
| Input Range | ±200–5000 mV |
| Communication | Micro-B USB, Ethernet |
| Enclosure | Fiberglass weatherproof cabinet (43 × 35 × 16 cm), 11.5 kg |
| Operating Mode | AVRD adaptive power-saving mode with automatic Ksh zero-point recalibration |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HCFM-XP Gen3 |
| Measurement Diameter Range | 1–36 mm |
| Flow Rate Range | 0.01–350 g/h (5 selectable ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 3.5×10⁻⁴ kg·s⁻¹·MPa⁻¹ |
| Pressure Output Resolution | 0.1 kPa |
| Max Operating Pressure | 620 kPa |
| Deaerated Water Reservoir Capacity | 0.7 L |
| Compressed Gas Cylinder Capacity | 170 L (at STP), CGA-580 valve |
| Data Acquisition | 1 reading per 2 s |
| A/D Conversion | 24-bit dual analog/digital |
| Dimensions (L×W×H) | 61×48×23 cm |
| Weight | 15 kg |
| Power & Interface | USB-powered, integrated data logging |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HPFM-Gen3 |
| Pressure Range | 0–630 kPa |
| Flow Rate Range | 0.7–2500 g/h (6 full-scale ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 2.2×10⁻³ kg·s⁻¹·MPa⁻¹ |
| Sampling Interval | 1 reading per 2 s |
| A/D Resolution | 24-bit dual analog-to-digital conversion |
| Dimensions | 33 × 31 × 52 cm |
| Weight | 12 kg (excluding pressure vessel) |
| Deaerated Water Capacity | 8 L |
| Power & Interface | USB-powered, no external power supply required |
| Operating Systems | Windows XP, Vista, Windows 7 |
| Compliance | NIST-traceable calibration, GLP-compliant data acquisition architecture |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP Monitoring Network |
| Node-to-Node Range | 300–500 m |
| Onboard Storage | 30,000 Records per Node |
| Compliance | Designed for Field-Deployable Ecophysiological Research under GLP-Aligned Data Integrity Practices |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SGDC |
| Type | Heat Balance-Based Stem Flow Sensor |
| Compliance | Validated per USDA-ARS protocols (Lascano et al., 2016, *Agric. Sci.*) |
| Channel Requirement | 2 differential analog inputs (temperature + heater voltage/current) |
| Stem Diameter Range | 7–25 mm (model-dependent) |
| Enclosure Design | EXO-Skin conformal wrap |
| Heater Architecture | Molded, low-thermal-mass resistive element |
| Environmental Protection | IP67-rated moisture barrier |
| Calibration Traceability | NIST-traceable thermistor and voltage references |
| Brand | DianJiang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ECA-YLS01 |
| Price Range | USD 7,000 – 14,000 |
| Light Source | 470 nm Blue LED |
| Photosynthetic Photon Flux Density (PPFD) | 0–5000 μmol·m⁻²·s⁻¹ (adjustable) |
| Minimum Sampling Interval | 2 μs |
| Data Acquisition Rate | Up to 500,000 points per second |
| Onboard Storage | 4 GB microSD card |
| Interface | USB 2.0 |
| Display | 128 × 64 monochrome LCD |
| Power Supply | Rechargeable Li-ion battery (7.6 V, 2.6 Ah) |
| Weight | 400 g |
| Dimensions | 12.5 × 8.0 × 3.3 cm |
| Dark Adaptation Clip | Integrated, leaf-compatible design |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EcoDrone UAS |
| Price | USD 15,280 (converted from ¥108,261.13 |
| note | original figure appears to contain typographical error — “万” implies ×10⁴, but ¥108 million is inconsistent with market pricing for UAS platforms |
| Platform | Octocopter |
| Max Payload | 4 kg |
| Endurance (multi-spectral config) | 20 min |
| Max Speed | 10 m/s |
| GNSS | GPS/GLONASS/BeiDou/Galileo |
| Imaging | GoPro HERO4 Black (4K@30fps, 12MP), C3-UAV 5-band prism-based multispectral camera (RGB + Red Edge + NIR), optional C5-UAV, sCMOS-UAV, hyperspectral, thermal (640×512, 7.5–13.5 µm), radiometric calibration support |
| Ground Station | GIS-integrated flight planning (Google/Bing/AMap), real-time telemetry, geotagged data logging, Follow-Me mode |
| Operating Temp | −5°C to +40°C (airframe), −20°C to +50°C (sensors) |
| Compliance | CE, FCC, RoHS |
| Software | ECO-Flight Suite v4.2 (supports NDVI, NDRE, GNDVI, PRI, SAVI, LAI derivation |
| Brand | Ecomatik |
|---|---|
| Origin | Germany |
| Model | DF1 / DF2 / DF3 |
| Measurement Principle | High-Resolution Linear Displacement Transduction via Spring-Loaded Contact Probe |
| Sensor Range | 15 mm (DF1), 25.4 mm (DF2), 50.8 mm (DF3) |
| Full-Scale Diameter Monitoring Range | 0–110 mm (expandable) |
| Accuracy | ±2 µm (DF1), ±3.3 µm (DF2), ±6.6 µm (with CR1000 Logger) |
| Resolution | 0.04% of reading + 6–20 µm (logger-dependent) |
| Temperature Coefficient | <0.2 µm/°C |
| Operating Temperature | −25 to +70 °C |
| Relative Humidity | 0–100% RH |
| Weight | 15 g (DF1), 26 g (DF2), 37 g (DF3) |
| Power | Internal battery, >2 years continuous logging (with DL10 datalogger) |
| Data Storage | Up to 1,900,000 records (4 sensors, 1-min interval, 1-year capacity) |
| Interface | Analog voltage output (0–2.5 V or 0–5 V), compatible with Campbell Scientific CR1000/CR6, Delta-T Devices GP2, DataTaker DT80/DT85, and other standard analog-input loggers |
| IP Rating | IP67 (fully weatherproof) |
| Brand | Ecomatik |
|---|---|
| Origin | Germany |
| Model | SF-G |
| Measurement Principle | Granier Thermal Dissipation Method |
| Probe Configuration | Dual-needle, Constant Current Heating |
| Output Signal | 0–1000 µV differential voltage |
| Power Consumption | 0.2 W ±5% (84 mA @ 12 VDC) |
| Operating Temperature | –25 to +50 °C |
| Cable Length | Standard 5 m (extendable to 20 m) |
| Suitable Stem Diameter | >5 cm |
| Probe Variants | SF-G33 (33 mm needle / 20 mm heater), SF-G43 (43 mm / 20 mm), SF-G63 (63 mm / 20 mm) |
| Compliance | Compatible with ISO 17025-accredited data acquisition systems and GLP/GMP environmental monitoring workflows |
| Brand | Ecomatik |
|---|---|
| Origin | Germany |
| Model | SF-L |
| Probe Type | TDP-based Thermal Dissipation Probe (4-pin, dual-pair configuration) |
| Probe Length | 33 mm (heated) / 20 mm (reference) |
| Minimum Stem Diameter | >20 cm |
| Power Consumption | 0.2 W (84 mA DC) |
| Output Signal | –100 to +1000 µV differential |
| Cable Length | 5 m (extendable up to 20 m) |
| Compatible Data Logger | Campbell Scientific CR1000 (32 differential channels, expandable to 128 via AM16/32 multiplexer) |
| Power Supply | SF30 Constant-Current Source (supports 3 SF-L probes simultaneously) |
| Compliance | Designed for long-term field deployment under ISO 17025-aligned environmental monitoring practices |
| Software | PC-based acquisition and calibration suite with zero-point correction algorithms |
| Accessories Included | SF60 extension cable, SF40 installation kit, weatherproof enclosure, power supply, user manual |
| Brand | Ecomatik |
|---|---|
| Origin | Germany |
| Model | SF-L |
| Probe Type | SF-L33 (4-pin TDP thermal dissipation probe) |
| Probe Length | 33 mm (heated) / 20 mm (reference) |
| Cable Length | 5 m (extendable to 20 m) |
| Minimum Stem Diameter | >20 cm |
| Power Consumption | 0.2 W (84 mA DC) |
| Output Signal | –100 to +1000 µV differential |
| Excitation | Constant-current source (SF30 power supply, supports up to 3 probes) |
| Data Logger Compatibility | Campbell Scientific CR1000 (32 differential inputs, expandable to 128 channels via AM16/32 multiplexer) |
| Internal Memory | 2 MB (~100,000 records, ~200 days at 30-min interval) |
| Communication Interface | RS-232 (9-pin) |
| Brand | EcoTech |
|---|---|
| Origin | Austria |
| Model | AC-21 |
| Camera Resolution | 8 MP (3280 × 2464) |
| Optical Resolution | 2500 dpi |
| Image Capture Time | <1 s per frame |
| Root Tube Dimensions | OD 70 mm, ID 64 mm |
| Field of View | 40 mm × 30 mm (full), 20 mm × 20 mm (cropped) |
| Illumination | Dual-row COB LED (3 W each, 330 lm @ 6500 K, adjustable) |
| Power Supply | 24 V DC, max 72 W, standby <1 W |
| System Weight | 4–5 kg |
| Software | MR Editor + In-situ Root Morphology Analysis Suite |
| Brand | EcoTech |
|---|---|
| Origin | United Kingdom |
| Model | AM400 |
| Measurement Parameters | Leaf area, maximum length, maximum width, perimeter, mean area, cumulative area, aspect ratio & shape factor |
| Units | mm or cm |
| Scanner | Integrated contact image sensor array with tunable RGB illumination (single or combined color modes) |
| Scan Speed | up to 20 mm/sec |
| Max Scan Width | 183 mm |
| Max Scan Length | 3 m |
| Accuracy/Repeatability | Linear ±1%, Area ±2%, Perimeter ±5% |
| Resolution | 0.016 mm² |
| Memory | 256 KB RAM (~2000 measurements) |
| Data Interface | USB-C |
| Battery Life | Up to 3,000 measurements per full charge |
| Dimensions | Scanner 216 × 115 × 70 mm |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Digital Plant Factory |
| Pricing | Available Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | ET-LEDIF |
| Measurement Principle | Active LED-induced chlorophyll fluorescence spectroscopy & multispectral reflectance imaging |
| Instrument Type | Field-deployable fixed or mobile monitoring system |
| Spectral Range (fluorescence) | 650–800 nm |
| Excitation Wavelength | 450 nm |
| Fluorescence Parameters | Fs, F690, F740, F735, F700, F690/F740, F735/F700, Rfd, QY, Kautsky kinetics |
| Reflectance Bands | 650–1000 nm (FWHM 2.2 nm @ 25 µm slit) |
| Vegetation Indices | NDVI, NIRv, CI, WBI, FRI, DCNI, SIF |
| Air Temp/Humidity | –40–60 °C / 0–100 % RH (±0.1 °C / ±2 % RH) |
| PAR Sensor | 400–700 nm, 10.0 mV/(µmol·m⁻²·s⁻¹) |
| Canopy IR Thermometer | –20–65 °C (±0.2 °C), 8–14 µm, FOV 18° |
| Soil Moisture (TDR) | 5–50 % vol (±3 %), Resolution 0.05 % |
| Soil Temp | –10–70 °C (±0.5 °C), Resolution 0.02 °C |
| Optional Modules | Leaf-scale fluorescence unit (OJIP, PI, Fv/Fm, ABS/RC), stem flow (SHB/THB), stem/growth/fruit sensors, leaf surface temperature, net radiometer, anemometer, rain gauge |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ET-PSI |
| Pricing | Available Upon Request |