Process Control System
Filter
Showing all 19 results
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JAR-2 |
| Pricing | Available Upon Request |
| Control System | Microprocessor-Based CPU Control |
| Cycle Start Delay | 1–999 minutes |
| Cycle Termination Time | 1–999 minutes |
| Maximum Cycle Count | 99 cycles |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 05627-71 (85–264 VAC, 50–60 Hz), 05627-73 (12–24 VDC ±10%) |
| I/O Capacity | Up to 6 input modules, 2 relay cards (4 relays total), 1 dual-channel analog output card (4–20 mA / 0–5 V / 0–10 V), optional RS-232 communication card |
| Display | Dual-line, 16-character alphanumeric backlit LCD |
| Units | 30 built-in engineering units (flow, pressure, level, volume, pH, ORP, conductivity) |
| Accumulation | Resettable and non-resettable flow totalizers |
| Programming | Front-panel 4-button keypad |
| Compliance | CE-marked |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 05628-00 |
| Power Supply | 12–24 V AC/DC, 50/60 Hz |
| Display | 2-line × 16-character alphanumeric LCD with backlight |
| Relays | 2 × SPDT (5 A @ 250 V AC / 30 V DC) |
| Analog Output | 4–20 mA (non-isolated) |
| Pulse Output | EOB (End-of-Batch) for remote start/stop/resume |
| Input Frequency Range | 5–1000 Hz (optically isolated) |
| Operating Temperature | –10 to 55 °C (14 to 131 °F) |
| Enclosure Dimensions | 89 mm × 89 mm × 89 mm (3.5" × 3.5" × 3.5") |
| Mounting | Panel-mount with included bracket and adhesive template |
| Memory | Non-volatile EEPROM for configuration retention during power loss |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model Numbers | 32708-00, 32708-22, 32708-32 |
| Flow Range | 0–50 sccm (32708-00) |
| Accuracy | ±1.5% of Full Scale (FS), including linearity |
| Repeatability | ±0.5% FS |
| Response Time | ≤2 sec (to ±2% of setpoint, 25–100% FS step) |
| Operating Pressure | 5–40 psia (inlet) |
| Max system pressure | 150 psi |
| Temperature Range | 10–50°C ambient |
| Gas temp | 18–25°C nominal |
| Input/Output | 0–5 VDC analog control signal (input for valve actuation |
| Wetted Materials | Anodized aluminum, 316 stainless steel, brass, PTFE, acetal |
| Display | 3½-digit LCD (tiltable up to 90°), optional on models 32708-2x and 32708-3x |
| Gas Selection | DIP-switch configurable for Air, He, or Ar (factory-calibrated) |
| Power/IO Cable | Integrated 3-in-1 cable (power + 0–5 V input + 0–5 V output) |
| Pressure Drop | ≤15 psi at full scale flow |
| Compliance | Designed for use in general industrial process control environments |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model Numbers | 33114-00, 33114-06, 33114-16 |
| Input Type | Pulse Input (33114-00) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.1% of reading ±1 digit |
| Display | 6-digit, 1/2-inch red LED |
| Input Signal | Pulse (max 28 VDC) |
| Power Supply | 85–265 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X |
| Dimensions | 101.6 mm W × 52.4 mm H × 98.4 mm D |
| Output Options | Dual relay, RS-485 digital output, 4–20 mA analog output |
| Linearization | 15-point user-defined linearization and square-root extraction for non-linear flow sensors |
| Batch Functionality | Single- or dual-valve batch control with auto-reset totalizer and cycle counter |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 160100 |
| Pricing | Available Upon Request |
| Material | CuSn Bronze Body |
| Operating Temperature | −200 °C to +120 °C |
| Size Range | DN8–DN50 |
| Pressure Rating | PN10–PN40 |
| End Connections | Threaded (Standard), Socket Weld / Flanged / Butt Weld (Optional) |
| Seal Type | Reusable Soft Seat with Bubble-Tight Shutoff Verified per ISO 5208 |
| Cryogenic Stem Extension | Stainless Steel Extended Bonnet & Stem |
| Compliance | Designed for ASME B16.34, EN 1515-1, ISO 5208, and PED 2014/68/EU |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 160800 |
| Body Material | ASTM A351 CF3M (304L SS) |
| Connection Type | Butt-Weld (BW) Standard |
| Optional Ends | Socket-Weld (SW) or Flanged |
| Nominal Size Range | DN8–DN32 |
| Pressure Rating | PN10–PN50 |
| Temperature Range | –220 °C to +120 °C |
| Seal Type | Reusable Soft Seat with Bubble-Tight Shutoff per ISO 5208 Class VI |
| Bonnet Design | Extended Low-Temperature Bonnet with Stainless Steel Extension Sleeve |
| Stem & Bonnet Material | ASTM A182 F304L (Low-Temp Grade) |
| Fire-Safe Compliant | Optional per API RP 520 / ISO 10497 |
| Actuation | Manual (Lockable Handwheel) or Pneumatic/Electric Actuator (Fail-Open / Fail-Close) |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 170300 |
| Material | ASTM B209 Grade 5083 Aluminum Alloy |
| Connection Type | Butt-Weld (Body), External Thread + Yoke (Bonnet) |
| Operating Temperature Range | −220 °C to +200 °C |
| Pressure Rating | PN10 to PN50 |
| Nominal Diameter | DN10 to DN400 |
| Seal Type | Reusable Metal Seat + Soft Seal Disc |
| Bonnet Extension | Bolted, Extended Design |
| Packing Box | Cryogenically Optimized, Straight-Through Configuration |
| Compliance | Suitable for ASME B16.34, ISO 2852, and EN 1515-2 (Low-Temperature Service) |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 180700 |
| Pricing | Upon Request |
| Material | ASTM A351 CF3M (304L) Body & Bonnet |
| End Connections | Butt-Weld (BW) Standard |
| Seat | Integral Seat with Reusable Soft Seal |
| Leakage Class | ISO 5208 Class A (Bubble-Tight) |
| Packing Box | Cryo-Optimized, Direct-Through Configuration |
| Temperature Range | −220 °C to +200 °C |
| Pressure Rating | PN16 to PN100 |
| Nominal Size Range | DN15 to DN200 |
| Compliance | EN 1515-1, EN 10222-4, PED 2014/68/EU, ISO 15848-1 (Low Emission) |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Model | SS-800 |
| Input Voltage | ±1.0 V |
| Threshold Setting Range | 1–99 mV |
| Delay Time Adjustment | 1–99 sec |
| Indicator Lights | POWER / PASSAGE / RECOVERY |
| Dimensions (W×H×D) | 227 × 48.5 × 140 mm |
| Power Supply | AC 85–132 V, 200 VA |
| Weight | 0.9 kg |
| Compatible Systems | All JAI preparative HPLC systems |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | PTUx |
| Form Factor | PCI board or standalone USB device |
| Timing Jitter | ≤ 0.05 ns |
| Firmware | Internally stored, model-optimized |
| Compatibility | Fully integrated with DaVis software |
| Trigger Outputs | Multiple synchronized TTL/CMOS outputs |
| Application Scope | Multi-camera synchronization, laser pulse sequencing, PIV-dt scans, hypersampling, phase-resolved imaging |
| Brand | Leichi |
|---|---|
| Model | PHGF Series |
| Type | pH and ORP Transmitter |
| Mounting Options | Submersible or Flow-Through |
| Integrated Pre-Amplifier Board | Yes (PHGF-27B, PHGF-28B, PHGF-43), No (PHGF-46) |
| Cable Length | 20 m (PHGF-27B, PHGF-28B, PHGF-43), 10 m (PHGF-46) |
| Operating Temperature Range | 5–60 °C or 20–90 °C (selectable for PHGF-27B & PHGF-28B), 5–45 °C (PHGF-43), 5–55 °C (PHGF-46) |
| Compatible Electrodes | FG-990 (pH), ORP-1 (ORP), FG-991 (pH), FG-991A (pH), FG-990T-819-A (high-temp pH) |
| Brand | Leichi |
|---|---|
| Model | PHGF Series |
| Type | pH and ORP Transmitter |
| Mounting Options | Submersible (PHGF-27B, PHGF-28B, PHGF-43) / Flow-Through (PHGF-28B, PHGF-46) |
| Integrated Pre-amplifier Board | Yes (PHGF-27B, PHGF-28B, PHGF-43) / No (PHGF-46) |
| Cable Length | 20 m (PHGF-27B, PHGF-28B, PHGF-43) / 10 m (PHGF-46) |
| Operating Temperature Range | 5–60 °C or 20–90 °C (selectable, PHGF-27B & PHGF-28B) / 5–45 °C (PHGF-43) / 5–55 °C (PHGF-46) |
| Compatible Electrodes | FG-990 (pH), ORP-1 (ORP) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | ACM500 |
| Pricing | Available Upon Request |
| Enclosure | Stainless Steel, IP66 Rated |
| Hazardous Area Certifications | UL/cUL Class I, II, III Div 1 Groups A–G (Entity) |
| Communication Interfaces | Fiber Optic, Intrinsically Safe Current Loop, Ethernet (10/100BASE-T), RS-232/RS-485 (expandable via COM3 option board) |
| I/O Expansion | Up to 12 digital inputs & 18 digital outputs (with ARM100 + COM3) |
| Dimensions | 210 × 265 × 106 mm (8.3 × 10.4 × 4.2 in.) |
| Power Supply | 100–240 VAC, 50/60 Hz, 250 mA |
| Brand | METTLER TOLEDO |
|---|---|
| Model | AWS-ZRCD30 |
| Type | Integrated Curved-Plate WIM Sensor System |
| Compliance | Designed for ASTM E1318, ISO 12098, and EN 1430–1432 Class C compatible deployment |
| Output Interface | RS-485, Ethernet (TCP/IP), Modbus RTU/TCP |
| Dynamic Accuracy | ≤ ±2.5% of reading (per axle, compliant with OIML R134 Class C requirements under controlled traffic conditions) |
| Operating Temperature Range | –30 °C to +70 °C |
| IP Rating | IP68 (sensor plate), IP54 (enclosure) |
| Fatigue Life | ≥3 million axle passes (validated per ISO 14224) |
| Overload Capacity | ≥150% F.S. (static), ≥200% F.S. (impact transient) |
| Detection Capabilities | Axle weight, gross vehicle weight (GVW), axle spacing, axle count, vehicle speed, wheel configuration, vehicle class (up to 6 axle groups), direction of travel |
| Anti-Cheating Features | Dual-sensor interleaved layout, real-time dynamic waveform analysis, S-curve & edge-pressure anomaly detection, synchronized dual-channel AxlemateD signal processing |
| Brand | METTLER TOLEDO |
|---|---|
| Model | ICS429/439 |
| Protection Rating | IP68/IP69K |
| Display | LCD dot-matrix |
| Data Display Modes | 3 configurable formats |
| Hygienic Design Compliance | EHEDG, NSF |
| Built-in Smart Counter | Yes |
| Certification Status Indication | On-screen dynamic marking |
| Sealing | Dual-layer waterproof sealing |
| Mounting Flexibility | Compact t-/f-/s- mounting variants |
| Special Functions | Animal Weighing, MinWeigh |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 160700 |
| Body Material | 304L Stainless Steel (standard), optional 316L |
| Connection | Butt-Weld (standard), optional Flanged |
| Design Temperature Range | −220 °C to +200 °C |
| Size Range | DN8–DN50 |
| Pressure Rating | PN10–PN100 |
| Bonnet Type | Extended Bolted Bonnet |
| Seat Integration | Integral Seat with Reusable Soft Seal Disc |
| Fire-Safe Design | Compliant with ISO 10497 |
| External Surface | Copper-Free Construction |
| Stem & Bonnet Extension | Cryogenic-Optimized Stainless Steel |
| Packing | Enhanced Graphite-Based Packing with Reinforced Gland Assembly |
| Actuation Options | Pneumatic or Electric Actuator (FO/FC), Manual Handwheel with Locking Device |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 160700HP |
| Body Material | 316L Stainless Steel |
| End Connection | Butt-Weld (Standard) |
| Operating Temperature | –220 °C to +200 °C |
| Pressure Rating | PN150–PN630 |
| Nominal Size | DN8–DN50 |
| Seat Material | Stellite™ Hardfaced |
| Stem & Bonnet Extension | Low-Temperature Stainless Steel (304L/316L) |
| Packing | Dynamic-Load Graphite |
| Optional | Throttling Plug, PCTFE (Kel-F™)-Seated Plug, Socket-Weld or Flanged Ends, Lockable Handwheel, Pneumatic Actuator (FO/FC) |
| Brand | IRELAND |
|---|---|
| Origin | France |
| Model | 190700 |
| Body Material | 304L Stainless Steel |
| End Connection | Butt-Weld (BW) |
| Seat Design | Integral Seat with Reusable Soft Seal Disc |
| Temperature Range | –220 °C to +200 °C |
| Pressure Rating | PN16 to PN100 |
| Nominal Size | DN15 to DN200 |
| Cryogenic Extension | Extended Bonnet with Bolted Construction |
| Vacuum Jacket Compatibility | Disc-Integrated Welding Pad on Upper Stem |
| Compliance | Designed for ASME B16.34, EN 1515-1, ISO 15848-1 (fugitive emissions), and applicable cryogenic service standards |
