BEIYU CCL-100 Intelligent Chloride Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand BEIYU TECHNOLOGIES
Origin Shanghai, China
Model CCL-100
Instrument Type Online Chloride Analyzer
Measurement Range 0–3000 mg/L Cl⁻
Detection Limit ≤2% RSD (Relative Standard Deviation)
Response Time ≤10 min per sample
Measurement Accuracy ±0.02 mg/L (at low concentration range)
Compliance Fully aligned with GB/T 5750.5–2023 (Standard Methods for Examination of Drinking Water – Inorganic Nonmetallic Indicators – Chlorides)
Automation Features Auto-sampling, auto-dilution, auto-titration with AgNO₃, auto-calibration of silver nitrate standard, auto-rinsing of reaction cell, scheduled testing, real-time data upload via Modbus TCP/RS485

Overview

The BEIYU CCL-100 Intelligent Chloride Analyzer is a fully automated online analytical system engineered for precise, trace-level quantification of chloride ions (Cl⁻) in aqueous matrices using potentiometric titration with silver nitrate (AgNO₃). Based on the classical Mohr method—formally standardized in GB/T 5750.5–2023—the instrument implements a rigorously controlled endpoint detection protocol: chloride reacts stoichiometrically with Ag⁺ to form insoluble AgCl precipitate; excess Ag⁺ then couples with chromate indicator (K₂CrO₄) to yield brick-red Ag₂CrO₄, signaling titration completion. Unlike conventional benchtop titrators, the CCL-100 integrates fluidic automation, electrochemical endpoint recognition, and embedded process logic to deliver unattended, high-reproducibility chloride analysis across fluctuating sample loads. Its architecture supports continuous operation under ambient or controlled environmental conditions, making it suitable for integration into water treatment control loops, effluent monitoring stations, and centralized laboratory workflows.

Key Features

  • Fully compliant implementation of GB/T 5750.5–2023: Reagent composition, titrant delivery kinetics, and endpoint discrimination algorithms replicate manual silver nitrate volumetric procedures without deviation.
  • Online, unattended operation: Configurable sampling intervals (1–240 min), 7×24 h autonomous cycling, and integrated fault diagnostics ensure operational continuity with minimal human intervention.
  • Dynamic auto-dilution module: Detects high-concentration samples (>3000 mg/L Cl⁻) via preliminary conductivity screening and executes programmable serial dilution to maintain measurement linearity and precision.
  • Self-calibrating AgNO₃ delivery system: Onboard standard solution reservoir with gravimetric calibration traceability; automatic daily recalibration against certified KCl reference standards.
  • Reaction cell with ultrasonic-assisted cleaning: Prevents AgCl residue accumulation and cross-contamination between samples; validated for ≥500 consecutive analyses without manual maintenance.
  • Dual communication interface: Native support for Modbus TCP (Ethernet) and RS485 (RTU) protocols enables seamless integration with SCADA, DCS, or LIMS platforms.

Sample Compatibility & Compliance

The CCL-100 accepts raw, filtered, or clarified water samples—including drinking water, surface water, groundwater, industrial wastewater, irrigation return flow, and seawater-influenced brackish matrices—provided turbidity remains below 10 NTU and suspended solids are <5 mg/L. It is not intended for highly viscous, particulate-laden, or strongly oxidizing samples without pretreatment (e.g., filtration, centrifugation, or UV digestion where organic interference is suspected). All hardware, firmware, and data handling modules comply with ISO/IEC 17025:2017 general requirements for competence of testing and calibration laboratories. Data audit trails satisfy GLP and GMP documentation prerequisites, including timestamped event logging, user-access controls, and electronic signature support for FDA 21 CFR Part 11 readiness.

Software & Data Management

The embedded Linux-based controller runs BEIYU Analytical Suite v3.2—a validated application environment supporting method configuration, calibration history tracking, QC flagging (e.g., drift >0.5% over 24 h), and automatic report generation (PDF/CSV). Raw titration curves, equivalence point coordinates, and intermediate dilution factors are stored locally (8 GB internal eMMC) with optional cloud backup via TLS 1.2–secured MQTT. All exported datasets include metadata fields: sample ID, acquisition timestamp, operator ID, instrument serial number, reagent lot numbers, and compliance status against GB/T 5750.5–2023 acceptance criteria (e.g., RSD ≤2% for triplicate parallels).

Applications

  • Drinking water treatment plants: Real-time monitoring of post-chlorination residual chloride and desalination permeate quality control.
  • Industrial discharge compliance: Continuous verification of effluent chloride levels against local regulatory thresholds (e.g., EPA 40 CFR Part 423, EU WFD Annex V).
  • Agricultural water management: Assessment of irrigation water salinity risk (Cl⁻ contribution to SAR and EC calculations).
  • Academic and method validation labs: Reference-grade platform for interlaboratory comparison studies and titrimetric method development.
  • Pharmaceutical manufacturing: Monitoring chloride in purified water (PW) and water-for-injection (WFI) distribution loops per USP and EP 2.2.38.

FAQ

Does the CCL-100 require manual reagent preparation?

No. Pre-formulated, stabilized AgNO₃ titrant and K₂CrO₄ indicator solutions are supplied in sealed, light-protected cartridges with barcoded lot traceability. The system performs all dispensing, mixing, and waste handling autonomously.
Can the analyzer be validated for regulated environments?

Yes. IQ/OQ documentation packages—including as-delivered specifications, alarm response verification, and repeatability testing per ISO 5725–2—are available upon request. Full 21 CFR Part 11 configuration support is included in firmware v3.2.1+.
What maintenance intervals are recommended?

Daily: Visual inspection of fluidic lines and waste container level. Quarterly: Replacement of AgNO₃ cartridge, indicator cartridge, and reaction cell O-rings. Annually: Full metrological verification using NIST-traceable KCl standards.
Is remote troubleshooting supported?

Yes. Secure SSH access (disabled by default) and diagnostic telemetry streaming enable BEIYU Field Support Engineers to analyze real-time sensor health, pump duty cycles, and titration curve anomalies without onsite presence.