Brookfield BSC-800 Temperature and Humidity Controlled Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Brookfield
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model BSC-800
Instrument Type Upright Chamber
Humidity Range 50–90% RH
Temperature Fluctuation ±0.5°C
Humidity Deviation ±5% RH
Heating Rate 1–3°C/min
Temperature Control Range 0–60°C
Temperature Resolution 0.1°C
Temperature Uniformity ±1.5°C (at 37°C)
Input Power 3800 W
Timer Range 0–9999 min
Interior Dimensions (W×D×H) 1220 × 585 × 1123 mm
Exterior Dimensions (W×D×H) 1503 × 910 × 1820 mm
Shelf Capacity 6 adjustable stainless steel shelves
Refrigerant Eco-friendly non-CFC refrigerant
Cooling System Integrated patented refrigeration unit with auto-defrost
Humidification Fin-type electric heating humidifier with imported humidity sensor
Water Tank Large-capacity external reservoir
Control Interface LCD microprocessor controller with programmable cycles (30 segments, 99 cycles)
Communication RS-485 port for PC or data logger connectivity
Safety Mechanical door lock, over-temperature alarm, power-failure data retention & auto-recovery

Overview

The Brookfield BSC-800 Temperature and Humidity Controlled Chamber is an upright environmental test chamber engineered for precise, long-term simulation of controlled thermal and hygroscopic conditions. Based on dual-loop PID control architecture, it maintains stable setpoints across its operational range (0–60°C, 50–90% RH) using independent proportional-integral-derivative algorithms for temperature and humidity regulation. The chamber employs a high-efficiency, non-CFC refrigeration system integrated with a patented auto-defrost mechanism that eliminates thermal interruption during defrost cycles—ensuring uninterrupted stability critical for pharmaceutical stability testing per ICH Q1 guidelines. Its airflow system utilizes a centrifugal blower and proprietary duct design to achieve uniform air distribution, validated at ±1.5°C temperature uniformity (at 37°C) and ±5% RH deviation across the full working volume.

Key Features

  • Stainless steel mirror-finish interior with six adjustable, load-rated shelves; cold-rolled steel exterior with electrostatic powder coating for corrosion resistance
  • Microprocessor-based LCD controller supporting up to 30 programmable segments and 99 repeatable cycles, with real-time display of setpoint, actual values, elapsed time, and alarm status
  • Integrated safety architecture including mechanical door lock, over-temperature cut-off, and power-loss memory with automatic parameter recovery
  • Imported capacitive humidity sensor coupled with fin-type electric heating humidifier and large-capacity external water reservoir for continuous operation up to 72+ hours without manual refill
  • RS-485 communication interface compliant with Modbus RTU protocol, enabling integration into centralized lab monitoring systems or third-party data loggers
  • Eco-conscious design featuring R134a or R600a refrigerant (model-dependent), low-noise compressor, and energy-optimized thermal insulation (polyurethane foam, ≥100 mm thickness)

Sample Compatibility & Compliance

The BSC-800 accommodates diverse sample formats—including Petri dishes, vials, blister packs, textile swatches, polymer specimens, and packaged food units—within its 1220 × 585 × 1123 mm working chamber. Dual 60 mm OD / 30 mm ID access ports (left and right side) allow for passive or active in-chamber monitoring (e.g., fiber-optic probes, thermocouple feeds) without compromising environmental integrity. The chamber meets structural and performance requirements aligned with ISO 16770:2017 (environmental testing—general principles), ASTM E145-22 (standard specification for gravity-convection and forced-ventilation ovens), and supports validation protocols required under FDA 21 CFR Part 11 when paired with compliant software and audit-trail-enabled data acquisition systems. It is routinely deployed in GLP-compliant laboratories for stability studies per ICH Q5C and packaging validation per ASTM D4332.

Software & Data Management

While the BSC-800 operates autonomously via its embedded controller, its RS-485 interface enables bidirectional communication with external platforms. When connected to Brookfield’s optional LabLink™ Environmental Suite (v3.2+), users gain real-time remote monitoring, configurable alarm escalation (email/SMS via GPRS add-on), automated report generation (PDF/CSV), and electronic signature–enabled audit trails compliant with 21 CFR Part 11 Annex 11 requirements. All logged data—including temperature, humidity, cycle phase, and event timestamps—is stored with immutable metadata (operator ID, instrument serial, calibration status). Optional thermal printer support provides hard-copy traceability of trend curves and pass/fail summaries for QA documentation.

Applications

  • Pharmaceutical stability testing (accelerated and long-term conditions per ICH Q1A–Q1E)
  • Accelerated aging of medical device packaging per ISO 11607-1
  • Textile moisture regain and dimensional stability assessment (ISO 139, AATCC 20A)
  • Food product shelf-life modeling under controlled humidity stress (ISO 21807)
  • Electronics component preconditioning prior to reliability testing (JEDEC JESD22-A101)
  • Biological reagent storage qualification and excipient compatibility screening
  • Adhesive and coating cure profiling under variable T/RH regimes

FAQ

What is the maximum allowable ambient temperature for continuous operation?
The BSC-800 is rated for installation in rooms maintained at ≤30°C ambient with adequate ventilation (minimum 0.5 m clearance on all sides and rear). Operation above 32°C ambient may reduce cooling capacity and extend stabilization time.
Can the chamber be validated for GMP use?
Yes—the BSC-800 supports IQ/OQ/PQ execution with documented calibration certificates (NIST-traceable temperature/humidity probes), mapping reports (16-point sensor grid), and change-control records. Full validation packages are available upon request.
Is humidity control possible below 50% RH?
No—the standard configuration is optimized for 50–90% RH. Sub-50% operation requires optional dehumidification module (BSC-DH-01), which extends range down to 20% RH using desiccant-assisted condensation.
How often does the humidifier require maintenance?
The fin-type humidifier and external water tank are designed for low-maintenance operation. Descaling is recommended every 3 months in hard-water areas; routine inspection of the water level sensor and overflow protection circuit is advised quarterly.
Does the unit comply with electromagnetic compatibility (EMC) standards?
Yes—it conforms to EN 61326-1:2013 (industrial EMC requirements) and EN 61000-6-3:2011 (emission limits), verified via third-party testing at accredited laboratories.