Empowering Scientific Discovery

Chengmeng NH100 Series High-Temperature Dry Block Thermostat

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Chengmeng
Model NH100 Series High-Temperature Dry Block Thermostat
Temperature Range RT+5°C to 160°C (NH100-1), RT+5°C to 130°C (NH100-2/NH100-4)
Temperature Accuracy ±0.5°C at 40°C, ±1.0°C at 120°C
Temperature Uniformity ±0.5°C
Display Resolution 0.1°C
Timer Range 1–99 h 59 min or continuous (∞)
Heating Time ≤15 min (25°C → 160°C), ≤20 min (25°C → 130°C)
Block Configuration 1-block (NH100-1), 2-block (NH100-2), 4-block (NH100-4)
Max Power 300 W / 500 W / 600 W
Input Voltage 220 V, 50/60 Hz
Dimensions (W×D×H) 260×220×100 mm (NH100-1), 360×220×100 mm (NH100-2/NH100-4)
Weight 5.0 kg / 5.5 kg / 8.0 kg

Overview

The Chengmeng NH100 Series High-Temperature Dry Block Thermostat is an engineered thermal management platform designed for precise, stable, and repeatable temperature control of samples in sealed tubes, vials, and microplates—without reliance on liquid baths. Utilizing Peltier-assisted resistive heating and high-efficiency aluminum alloy blocks with optimized thermal mass distribution, the NH100 delivers rapid thermal response and exceptional spatial uniformity across its active zone. Unlike water baths, dry block systems eliminate contamination risks, evaporation artifacts, and maintenance overhead associated with fluid media—making them ideal for applications requiring sterility, traceability, or operation in regulated environments such as clinical diagnostics, pharmaceutical QC labs, and academic research settings where ISO/IEC 17025-compliant thermal validation is required.

Key Features

  • Three configurable variants (NH100-1, NH100-2, NH100-4) supporting single-, dual-, or quad-block operation for parallel sample processing
  • Wide operational range: ambient +5°C to 160°C (NH100-1); ambient +5°C to 130°C (NH100-2/NH100-4), enabling enzyme inactivation, DNA denaturation, protein aggregation studies, and solvent evaporation protocols
  • High-resolution digital display (0.1°C resolution) with real-time feedback and intuitive keypad navigation
  • Programmable timer with continuous mode (∞) and precision countdown functionality (1 min to 99 h 59 min), supporting unattended overnight incubations
  • Robust aluminum heating blocks with interchangeable well inserts—compatible with standard 0.2 mL, 0.5 mL, 1.5 mL, and 2.0 mL tubes, as well as 96-well PCR plates
  • Thermal stability verified per ASTM E220-22 methodology; accuracy validated at multiple setpoints using NIST-traceable reference thermometers

Sample Compatibility & Compliance

The NH100 Series accommodates a broad spectrum of laboratory consumables—including polypropylene, glass, and metal vessels—without compromising thermal integrity. Its dry-block architecture inherently supports GLP/GMP workflows by eliminating cross-contamination pathways and enabling full auditability of thermal exposure history when paired with external data loggers. While the device itself does not include built-in 21 CFR Part 11 compliance features (e.g., electronic signatures or user-level access control), its stable thermal output and deterministic timing behavior make it suitable for use within validated processes under FDA-regulated quality systems—provided procedural controls (e.g., calibration logs, operator training records, and change control documentation) are maintained per SOP requirements.

Software & Data Management

The NH100 operates via embedded firmware without proprietary software dependencies. All configuration and monitoring occur locally through the front-panel interface. For laboratories requiring integration into centralized monitoring networks, optional RS-232 or USB-to-serial adapters (sold separately) enable connection to third-party SCADA or LIMS platforms. When used with compliant data acquisition tools, temperature profiles and timer events can be logged with timestamping, supporting retrospective analysis and regulatory reporting. Calibration certificates—traceable to national metrology institutes—are available upon request and include as-found/as-left data, uncertainty budgets, and environmental conditions during verification.

Applications

  • Thermal denaturation of nucleic acids and proteins in molecular biology workflows
  • Controlled drying of solvent-based extracts in analytical chemistry sample preparation
  • Stability testing of thermolabile reagents and reference standards
  • Pre-incubation of enzymatic reaction mixtures prior to kinetic assays
  • Standardization of thermal conditioning steps in ISO 10993 biocompatibility evaluations
  • Calibration support for thermocouples, RTDs, and infrared sensors in metrology labs

FAQ

What is the recommended calibration frequency for the NH100 Series?
Annual calibration is advised for routine use; however, labs operating under ISO/IEC 17025 or GxP frameworks should perform calibration prior to critical experiments and after any physical impact or extended non-use.
Can the NH100 be used for sub-zero temperatures?
No—the NH100 Series is strictly a high-temperature dry block system with minimum operating temperature set at ambient +5°C; it lacks active cooling capability.
Are custom well configurations available for non-standard tube formats?
Yes—Chengmeng offers OEM block customization services for specialized geometries (e.g., 0.1 mL strips, capillary tubes, or microfluidic cartridges), subject to minimum order quantities and lead time confirmation.
Does the device meet CE or RoHS directives?
All NH100 units shipped for export comply with EU Directive 2014/30/EU (EMC) and 2011/65/EU (RoHS), with conformity documented in the technical file and marked on the rear label.