- All
- Favorite
- Popular
- Most rated
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | X-8S |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Stray Light | ≤0.03%T |
| Display | 10-inch capacitive touchscreen (1024 × 600 resolution) |
| Data Interfaces | USB, Bluetooth, Wi-Fi (optional) |
| Compliance | GLP/GMP-ready software architecture |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SPH Series |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Cavity Rating | Industrial-Grade |
| Batch Capacity | 6 samples per run |
| Microwave Source | Single Magnetron (for paired MWD systems) |
| Max Operating Temperature | 250 °C / 300 °C (SPH-1/SPH-2 vs. SPH-3) |
| Max Pressure Tolerance (of compatible vessels) | 6 MPa |
| Heating Surface Coating | PFA (Perfluoroalkoxy) |
| Temperature Control | AI-enhanced PID with ramp/soak programming |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.5 °C |
| Power Input | 1.6–2.0 kW |
| Weight | 13–39 kg |
| Power Supply | AC 220 V ±10% |
| Compatible Main Systems | MWD-500/520, MWD-630/Trump, MWD-700/750, MWD-800/850 |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV-6000PC |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T |
| Display | 6-inch full-color LED LCD |
| Data Interface | USB port |
| Software | PC-based analytical software with GLP/GMP-compliant audit trail |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Q-5S |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.1–5.0 nm (continuously adjustable in 0.1 nm increments) |
| Stray Light | ≤0.01% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0003 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Q-8S |
| Optical Design | Dual-Beam with Dual Monochromator (Hybrid Czerny-Turner) |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm (extendable to 185 nm) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ≤0.05 nm |
| Spectral Bandwidth | 0.1–5.0 nm (continuously adjustable in 0.1 nm increments) |
| Stray Light | ≤0.00005% T |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.1% T |
| Baseline Drift | ≤0.0001 Abs/h |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TOC-1700 |
| Instrument Type | Online & Offline TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.5 ppm |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 0.05 ppb |
| Repeatability | ≤3% RSD |
| Display | 7-inch Color Touchscreen |
| Data Storage | 8 GB Internal Flash Memory |
| Analysis Time | ≤3 minutes per sample |
| Compliance | CP2025 General Chapter <0901>, USP <643>, FDA 21 CFR Part 11 (Audit Trail & User Authentication) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Absorption Method |
| Spectral Resolution | 0.1 nm |
| Sensitivity (Cu) | 0.02 µg/mL per 1% absorption |
| Detection Limit (Cu) | 0.002 µg/mL |
| Precision (RSD) | ≤1.0% |
| Wavelength Range | 190–900 nm |
| Grating Grooves | 1800 lines/mm |
| Spectral Bandwidths | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Drift | 0.003 A/30 min |
| Background Correction Capacity (D₂) | >30× at 1 A |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | X-9DS |
| Optical System | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 4.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.01%T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | TOC-1500 |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Measurement Range | 0.001–1.5 ppm (as C) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 ppb |
| Detection Limit | 1 ppb (as C) |
| Repeatability | ≤3% RSD |
| Display | 7-inch color touchscreen |
| Data Storage | 8 GB internal flash memory |
| Analysis Time | ≤3 minutes per sample |
| Compliance | USP <643>, CP 2025 Appendix IX Q, FDA 21 CFR Part 11 (audit trail & user authentication enabled) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV-9000 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Configuration | Dual-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–900 nm (extendable to 1100 nm with optional tungsten-halogen source) |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.01% T (at 220 nm and 340 nm) |
| Wavelength Scanning Mode | Motorized automatic wavelength drive |
| Display | 6-inch full-color LED TFT LCD |
| Data Interface | USB 2.0 |
| Software Compliance | GLP/GMP-ready with user authentication, audit trail, electronic signature support (21 CFR Part 11 compatible configuration available) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TOC-5000 RN |
| Instrument Type | Laboratory Benchtop TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (680–900 °C) |
| Measurement Range | 0–1000 mg/L as C |
| Accuracy | ≤5% of reading |
| Resolution | 0.01 ppb (as C) |
| Detection Limits | TC: 50 µg/L |
| IC | 20 µg/L |
| Repeatability | ≤3% RSD |
| Sample Form | Aqueous liquid only |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MWD-630 |
| Price Range | USD 28,000 – 42,500 |
| Cavity Class | Industrial-Grade |
| Batch Capacity | 1–12 samples |
| Microwave Source | Single Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 15 MPa |
| Temperature Control | Non-contact mid-infrared scanning |
| Pressure Control | Multi-fiber optic non-contact scanning |
| Inner Vessel Volume | 100 mL |
| Vessel Material | TFM fluoropolymer inner vessel |
| Microwave Power Output | 0–1000 W continuous |
| Display | 7-inch capacitive touchscreen |
| Dimensions (W×D×H) | 490 × 560 × 630 mm |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MWD-500 |
| Chamber Class | Industrial-Grade |
| Sample Capacity | 6/8/10 positions |
| Microwave Source | Single Magnetron |
| Max Temperature | 250 °C / 300 °C |
| Max Pressure | 6 MPa |
| Temperature Sensing | High-Accuracy Platinum Resistance (Pt100) |
| Pressure Sensing | Non-Contact Multi-Channel Optical Fiber Scanning System |
| Vessel Volume | 100 mL |
| Microwave Power Output | 0–1000 W |
| Control Interface | 7-inch Capacitive Touchscreen |
| Dimensions (W×D×H) | 490 × 560 × 533 mm |
| Vessel Construction | Inner Vessel — TFM (ASTM D4894-compliant fluoroelastomer) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | X-6DS |
| Optical System | Dual-beam |
| Detector | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized |
| Spectral Bandwidth | 0.8 / 1.8 / 4.0 / 5.0 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05%T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV-9000S |
| Optical System | Dual-beam |
| Detector Type | Photocell |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | Selectable (0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 4.0 nm) |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Stray Light | ≤0.05% T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | V-5600(PC) |
| Instrument Architecture | Dual-Beam Ratio-Monitoring Optical System |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Automation Level | Automatic Wavelength Scanning & Calibration |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | X-6 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.3% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A) |
| Photometric Repeatability | ≤0.15% T (0–100% T), ≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1.0 A) |
| Baseline Drift | ±0.001 A/h at 500 nm |
| Baseline Flatness | ±0.002 A |
| Noise Level | ≤0.4% T |
| Photometric Range | 0–200% T, –3.0 to +3.0 A, 0–9999 C |
| Data Interfaces | USB port, USB flash drive support, optional Bluetooth module, A4 inkjet printer interface |
| Display | 7-inch high-resolution capacitive touchscreen |
| Light Sources | Imported long-life tungsten lamp and deuterium lamp |
| Dimensions | 505 × 375 × 190 mm |
| Weight | 15.5 kg |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | C6080R |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–30,000 rpm (max. 18,000 rpm) |
| Function | Refrigerated centrifugation |
| Configuration | Horizontal rotor system |
| Max. Capacity | 4 × 250 mL |
| Max. RCF | 28,978 × g |
| Dimensions | 650 × 520 × 800 mm (L×W×H) |
| Noise Level | ≤58 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R-134a |
| Motor | AC brushless frequency-converter motor |
| Acceleration Steps | 9 |
| Deceleration Steps | 10 |
| Programmable Methods | 30 user-defined protocols |
| Display | Color LCD |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz, 1800 VA |
| Net Weight | 100 kg |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | TOC-5000 RD |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–1000 mg/L (expandable to 100,000 mg/L) |
| Accuracy | ≤5% |
| Resolution | 0.01 ppb |
| Detection Limits | TC: 50 µg/L |
| IC | 20 µg/L |
| Repeatability | ≤3% |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV-5100 |
| Optical System | Single-beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤0.5 nm |
| Spectral Bandwidth | 2 nm or 4 nm (selectable) |
| Stray Light | ≤0.1% T |
| Wavelength Scanning Mode | Automatic |
| Data Storage Capacity | 200 measurement sets + 200 calibration curves |
| Display | 128 × 64 dot-matrix LCD |
| Lamp Configuration | Plug-in deuterium and tungsten lamps with flange-mount base |
| Interface | USB data output port + parallel printer port |
| Software Option | Metash Quantitative Analysis Software (optional) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Resolution | <0.03 nm |
| Sensitivity | Cu 1 ppm → Absorbance >0.01 A |
| Precision (RSD) | ≤0.05% (Flame mode, optimized conditions) |
| Detection Limits | Cu ≤ 0.006 µg/mL (Flame), Cd ≤ 1.0 × 10⁻¹² g (Graphite Furnace) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | X-7 |
| Optical System | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T |
| Photometric Range | 0–200% Transmittance, –4.0 to +4.0 Absorbance, 0–9999 Concentration Units |
| Display | 10-inch capacitive multi-touch TFT LCD |
| Data Interface | USB 2.0 (for printer, flash drive, and PC connectivity) |
| Lamp Source | Imported long-life tungsten and deuterium lamps |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam Proportional Monitoring |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T at 220 nm and 360 nm |
| Display | 128 × 64 dot-matrix LCD |
| Data Interface | USB |
| Software Compatibility | Optional Metash UV-Vis Spectral Analysis Suite (GLP/GMP-compliant) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | UV-8000 |
| Optical System | Dual-beam |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.05% T |
| Display | 6-inch full-color LED touchscreen |
| Data Interface | USB port for PC connectivity |
| Software | GLP/GMP-compliant PC application with audit trail, user management, and report generation |
Show next