Empowering Scientific Discovery

DHG-9101-0SA Constant-Temperature Forced-Air Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Jiangsu, China
Manufacturer Type Authorized Distributor
Origin Category Domestic (PRC)
Model DHG-9101-0SA
Chamber Dimensions (W×D×H) 350 × 350 × 350 mm
Temperature Range 50–300 °C
Temperature Uniformity ±1 °C
Power Rating 0.5 kW
Construction Stainless Steel Interior
Control System Microprocessor-Based Digital PID Controller
Air Circulation Low-Noise Axial Fan with Optimized Duct Design
Compliance Meets GB/T 5170.2–2017 (IEC 60068-2-2 Equivalent) for Temperature Stability and Uniformity Testing

Overview

The DHG-9101-0SA Constant-Temperature Forced-Air Drying Oven is an entry-level yet rigorously engineered laboratory drying system designed for routine thermal processing tasks in quality control laboratories, academic research facilities, and industrial R&D environments. It operates on the principle of convective heat transfer, utilizing a precisely regulated forced-air circulation mechanism to maintain stable and uniform thermal conditions across the entire working chamber. Unlike natural-convection ovens, this model integrates a low-noise axial fan and an aerodynamically optimized internal duct structure to minimize thermal gradients—ensuring temperature deviations remain within ±1 °C across the specified 350 × 350 × 350 mm workspace. Its operational range spans from 50 °C to 300 °C, covering common applications including moisture removal from polymer samples, pre-weighing desiccation of analytical standards, post-extraction solvent evaporation, and low-temperature sterilization of glassware and non-critical tools.

Key Features

  • Robust Thermal Architecture: Welded carbon steel outer casing with high-emissivity stainless steel interior chamber; all internal corners formed as smooth radii (R ≥ 15 mm) to prevent particulate accumulation and simplify cleaning under GLP-compliant protocols.
  • Precision Temperature Control: Microprocessor-based digital PID controller with real-time display (0.1 °C resolution), programmable ramp/soak profiles, and over-temperature cut-off protection (independent mechanical thermostat at 320 °C).
  • Uniform Air Distribution: Strategically positioned rear-mounted fan and perforated top baffle ensure laminar airflow patterns—validated per GB/T 5170.2–2017 test methodology for spatial temperature consistency.
  • Energy-Efficient Operation: Insulated double-wall construction (70 mm mineral wool) combined with low thermal mass chamber design reduces power consumption to 0.5 kW while sustaining thermal stability during extended dwell cycles.
  • Modular Sizing Options: Standard chamber volume (42.9 L) supports ISO/IEC 17025 traceable calibration; optional larger configurations (e.g., 350 × 450 × 450 mm, 550 × 450 × 550 mm, and 600 × 500 × 750 mm) accommodate bulk sample trays or stacked petri dish racks without compromising uniformity.

Sample Compatibility & Compliance

The DHG-9101-0SA accommodates a broad spectrum of non-volatile and thermally stable materials—including ceramic powders, metal oxide catalysts, pharmaceutical excipients, soil aggregates, and dried biological matrices—provided their decomposition onset exceeds 300 °C. It is not suitable for flammable solvents, volatile organic compounds, or pyrophoric substances. The unit conforms to national standard GB/T 5170.2–2017 (equivalent to IEC 60068-2-2 Ed. 5.0), which defines performance criteria for temperature deviation, uniformity, and recovery time following door opening. While not certified to UL 61010-1 or EN 61010-1 out-of-the-box, its electrical architecture supports third-party safety validation for integration into ISO 9001-certified manufacturing workflows.

Software & Data Management

This model features a standalone front-panel interface with no embedded data logging or network connectivity. All operational parameters—including setpoint, actual chamber temperature, elapsed time, and fault codes—are displayed in real time via a 4-digit LED readout. For regulatory environments requiring audit trails (e.g., FDA 21 CFR Part 11 or EU Annex 11), external USB-connected temperature data loggers (e.g., Testo 176 T4 or Omega OM-EL-USB-TC) may be deployed alongside the oven to record time-stamped thermal profiles. Calibration verification is performed using NIST-traceable Class A PT100 probes placed at geometric center and three corner positions per ISO/IEC 17025 clause 6.4.3.

Applications

  • Drying of gravimetric samples prior to ash content analysis (ASTM D2974, ISO 1171)
  • Baking of filter papers and crucibles in environmental testing labs (EPA Method 1664)
  • Melting point determination support via pre-conditioning of capillary tubes
  • Low-temperature sterilization of reusable labware where autoclaving is impractical
  • Accelerated aging studies of packaging materials under controlled thermal stress (ISO 11607-1)
  • Pre-heating of substrates prior to thin-film deposition or coating processes

FAQ

Is the DHG-9101-0SA compliant with FDA 21 CFR Part 11?
No—this model lacks electronic signature capability, audit trail generation, or user access controls required for Part 11 compliance. Integration with validated external data loggers is necessary for regulated documentation.
Can it be used for sterilization of surgical instruments?
No—it does not meet the minimum requirements for dry-heat sterilization (e.g., 160 °C for 120 minutes per ISO 17665-1), nor does it provide cycle validation or load monitoring features.
What is the recommended recalibration interval?
Per ISO/IEC 17025 guidance, annual calibration against NIST-traceable references is advised; more frequent checks are required if used in critical QC release testing.
Does the oven include a timer function?
Yes—the microprocessor controller supports programmable dwell time (0–999 minutes) with automatic shutdown upon completion.
Are replacement shelves and trays available?
Standard stainless steel wire shelves (350 × 350 mm) and reinforced enamel-coated trays are available as optional accessories through authorized distributors.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0