Esco Labculture® LA2-A Class II Type A2 Biological Safety Cabinet

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Esco
Origin Singapore
Cabinet Type Class II, Type A2
Filter Efficiency 99.999% (ULPA, 0.1–0.3 µm)
Power Supply 220 VAC, 50 Hz
Compliance NSF/ANSI 49, EN 12469, YY 0569, JIS K 3800
Airflow Inflow 0.53 m/s (105 fpm), Downflow 0.35 m/s (70 fpm)
Construction Seamless stainless steel work area, ISOCIDE® antimicrobial powder coating
Control System Sentinel Gold™ microprocessor-based digital display with RS232 port
Ergonomics 10° front tilt, ADA-compliant angled control panel and display

Overview

The Esco Labculture® LA2-A is a Class II, Type A2 Biological Safety Cabinet engineered for rigorous containment of low-to-moderate risk biological agents (BSL-1 to BSL-2), while simultaneously protecting both personnel and product integrity. It operates on the principle of laminar airflow dynamics: inward-facing inflow (at ≥0.53 m/s) captures aerosols generated at the work surface, directing them through a pre-filter and then into a dual-stage filtration system; ~70% of recirculated air passes through two Minipleat ULPA filters (99.999% efficiency at 0.1–0.3 µm), while ~30% is exhausted externally via a dedicated ducted or thimble-connected system. This balanced airflow architecture ensures stable containment without compromising sample sterility—critical for cell culture, microbiological assays, and molecular biology workflows where cross-contamination must be eliminated. Designed and manufactured in Singapore under ISO 13485-certified quality systems, the LA2-A integrates decades of Esco’s biosafety engineering expertise with next-generation DC motor technology to deliver precise, quiet, and energy-efficient operation.

Key Features

  • Two Minipleat ULPA filters providing ≥99.999% particle capture efficiency for airborne contaminants down to 0.1 µm—exceeding HEPA performance and meeting IEST-RP-CC001.3 standards for filter longevity and integrity.
  • Seamless one-piece 304 stainless steel work chamber with zero weld seams, screws, or crevices—enabling rapid decontamination via vaporized hydrogen peroxide (VHP), formaldehyde fumigation, or liquid disinfectants.
  • Sentinel Gold™ digital control system featuring a large-format backlit LCD interface that displays real-time inflow/downflow velocities, filter life status, alarm history, and operational mode (e.g., normal, standby, sterilization).
  • 10° forward-tilted front sash and ergonomically angled control/display panel compliant with ADA accessibility guidelines—reducing operator fatigue during extended procedures.
  • ISOCIDE® antimicrobial powder coating applied to all external painted surfaces inhibits microbial colonization on cabinet exteriors, supporting long-term hygiene maintenance in high-traffic lab environments.
  • DC brushless motor drive system delivering consistent airflow stability across variable line voltage conditions, lower acoustic noise (<65 dBA), and up to 40% reduced energy consumption versus traditional AC motor cabinets.
  • RS232 serial communication port enabling integration with laboratory building management systems (BMS) or centralized monitoring platforms for audit-ready data logging.
  • High-efficiency air grilles and enhanced side-wall exhaust baffle design optimize uniformity of downward laminar flow and improve particulate entrapment at critical work zones.

Sample Compatibility & Compliance

The LA2-A accommodates standard benchtop workflows involving open vessels, Petri dishes, flasks, pipettes, and microcentrifuge tubes. Its certified airflow profile supports routine handling of recombinant DNA constructs, primary mammalian cells, bacterial cultures (including non-pathogenic strains of E. coli and Bacillus subtilis), and low-risk viral vectors. The cabinet conforms to international biosafety standards including NSF/ANSI 49 (USA), EN 12469 (EU), YY 0569 (China), and JIS K 3800 (Japan). All units undergo factory-certified performance validation—including smoke visualization, airflow velocity mapping, and microbial challenge testing per Annex D of NSF/ANSI 49—and are supplied with full traceability documentation suitable for GLP/GMP audits and institutional biosafety committee (IBC) review.

Software & Data Management

Sentinel Gold™ firmware supports configurable alarm thresholds, event-driven logging (e.g., sash position deviation, airflow loss, filter saturation), and timestamped parameter recording. Logged data—including date/time stamps, airflow values, and alarm triggers—is exportable via RS232 to CSV-compatible software for archival in electronic lab notebooks (ELN) or LIMS. While the LA2-A does not natively support FDA 21 CFR Part 11-compliant electronic signatures, its audit trail functionality meets foundational requirements for data integrity under ISO/IEC 17025 and CLIA regulations when paired with validated third-party data acquisition systems.

Applications

  • Cell culture maintenance and passaging in academic and pharmaceutical research laboratories.
  • Preparation of sterile media, reagents, and master cell banks under cGMP-aligned workflows.
  • Molecular cloning, plasmid purification, and transfection protocols requiring protection from environmental nucleases and aerosolized DNA.
  • Handling of diagnostic specimens classified as Risk Group 2 (RG2) pathogens under institutional biosafety protocols.
  • Quality control testing of biologics, vaccines, and sterile injectables in contract manufacturing organizations (CMOs).
  • Training environments where reproducible, visually verifiable airflow behavior supports biosafety education and SOP compliance verification.

FAQ

What certifications does the LA2-A hold for international use?
The LA2-A is independently certified to NSF/ANSI 49 (USA), EN 12469 (Europe), YY 0569 (China), and JIS K 3800 (Japan). Each unit ships with a Certificate of Conformance and test report from an accredited third-party laboratory.
Can the LA2-A operate in recirculating (non-ducted) mode?
No. As a Type A2 cabinet, it requires either hard-ducted exhaust to the outside or connection to a thimble canopy system. Recirculation-only operation is prohibited due to potential accumulation of trace gases and vapors.
Is the ULPA filter service life validated per industry standards?
Yes. Filter service intervals are calculated per IEST-RP-CC001.3, based on cumulative operating hours, ambient particulate load, and real-time pressure differential monitoring integrated into the Sentinel Gold™ system.
Does the cabinet support integration with facility-wide monitoring networks?
Yes—via its RS232 port, the LA2-A can transmit operational parameters to centralized dashboards using Modbus RTU or ASCII protocol, enabling remote health monitoring and predictive maintenance scheduling.
How is decontamination performed prior to filter replacement or maintenance?
Standard protocols include formaldehyde fumigation (using Esco-supplied plastic bags and catalysts) or vaporized hydrogen peroxide (VHP) cycles validated for compatibility with internal components and ULPA media integrity.