Empowering Scientific Discovery

Jingyi Xingye Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEYELA
OriginJapan
ModelCVE-2000
Rotational Speed1400 rpm (fixed)
Temperature Control RangeAmbient +5°C to 80°C
Ultimate Vacuum (internal pump)3 kPa
Ultimate Vacuum (external pump)≤1.33 kPa
Chamber DimensionsØ160 mm × H105 mm
Rotor Capacity24 × 1.5 mL microtubes (Ø10.8 mm)
Chamber & Tubing MaterialChemically Resistant Polymer Alloy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
ModelCOND600
OriginUSA
Instrument TypePortable Conductivity/TDS/Temp Meter
IP RatingIP67
GLP ComplianceYes
Measurement PrinciplesTwo-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration
Key RangesConductivity 0–200.0 mS/cm (5-range auto-ranging)
Resolution0.01 µS/cm (low range) to 0.1 mS/cm (high range)
Accuracy±1% of full scale + 1 LSD (conductivity & TDS)
CalibrationUp to 4-point automatic or 5-point manual using standard KCl solutions
Temperature CompensationLinear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C
Electrode Constant Range0.010–10.000 cm⁻¹
Data Storage500 measurement sets with timestamp, temperature, and electrode ID
ConnectivityRS-232C serial port, IrDA infrared interface
Power4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA)
Dimensions (unit)18.3 × 9.5 × 5.7 cm
Weight (unit)460 g
Operating Environment0–50 °C, ≤95% RH non-condensing
Storage Environment−25–70 °C
DisplayBacklit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view
Auto-offConfigurable 2–30 min idle timeout
Auto-holdYes
CertificationsCE, RoHS, FCC Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelInMotion KF Flex / Pro
Heating MethodInfrared
Sample Capacity24 positions on 25 cm footprint
Gas Flow ControlDigital mass flow meter (air or lab-line gas)
Temperature ProgramTemperature ramping and isothermal scanning
ComplianceDesigned for GLP/GMP environments with audit-trail-ready operation (when paired with compatible titrators)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck
OriginGermany
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelElix Advantage
Price RangeUSD 6,500 – 13,000 (est.)
Water GradeASTM Type II / ISO 3696 Grade 2
Resistivity>5 MΩ·cm @ 25 °C
Heavy Metals & Soluble Silica<0.1 ppb
Total Organic Carbon (TOC)<30 ppb
Microbial Count<0.001 EU/mL
Particles (>0.1 µm)<1 particle/mL
Optional Tank Capacities30 L, 60 L, 100 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Instrument TypeVolumetric/Coulometric Karl Fischer Titrator
Titration ModeFully Automated
Measurement Resolution0.1 mV
Water Content Range10 ppm to 100% (V20S: volumetric
V30Scoulometric, down to 1 ppm)
Accuracy±0.3% (for samples containing >10 mg H₂O)
Minimum Dispensing Volume0.05 µL
Titration Control Precision20,000 steps
ComplianceDesigned for GLP/GMP environments with audit trail capability per FDA 21 CFR Part 11 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Model05628-00
Power Supply12–24 V AC/DC, 50/60 Hz
Display2-line × 16-character alphanumeric LCD with backlight
Relays2 × SPDT (5 A @ 250 V AC / 30 V DC)
Analog Output4–20 mA (non-isolated)
Pulse OutputEOB (End-of-Batch) for remote start/stop/resume
Input Frequency Range5–1000 Hz (optically isolated)
Operating Temperature–10 to 55 °C (14 to 131 °F)
Enclosure Dimensions89 mm × 89 mm × 89 mm (3.5" × 3.5" × 3.5")
MountingPanel-mount with included bracket and adhesive template
MemoryNon-volatile EEPROM for configuration retention during power loss
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
Model1634
Dimensions (W×D×H)1800 mm × 500 mm × 2115 mm
Import StatusImported
Distributor TypeAuthorized General Distributor
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model77111-80
PriceUpon Request
Drive TypePneumatic
Max. Fluid Viscosity10,000 cP
Speed Range35–321 rpm
Flow Rate (with BT-87 tubing)1.9–17.7 L/min
Flow Rate (with BT-91 tubing)4.0–37.0 L/min
Air Supply Requirement340 L/min at ≥2.7 bar
Motor Power Equivalent0.75 hp (560 W)
Enclosure RatingIP56
CertificationsCE, CUL, ATEX Zone 2 (EEx II 3Gc IIC T6), NEC Class I, Div. 2, Groups A,B,C,D,T6
Dimensions (L×W×H)68.6×40.0×38.4 cm
Standard TubingTygon LFL #91, 0.9 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelST5010-CV5030
Automation LevelFully Automatic
Instrument TypeRotary (Carousel-Based)
Throughput Capacity3 Slide Racks per Load
Design IntegrationSeamless Interface with Leica Autostainer XL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGC-2010 Pro
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-purpose
Oven Temperature RangeAmbient +4 °C to 450 °C
Oven Ramp Rate–250 to +250 °C/min (programmable)
Oven Cool-down Time≤3.4 min (450 °C → 50 °C)
Carrier Gas Flow Range & Control0–1250 mL/min (7-segment programming)
Carrier Gas Pressure Range & Control0–1035 kPa (7-segment programming)
Injector Maximum Temperature450 °C
Injector Pressure Setting Range0–1035 kPa
Injector Total Flow Setting Range0–1250 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelSalt6+
Measurement PrincipleConductivity-based salinity determination with automatic temperature compensation (ATC)
Salinity Range1.0–50.0 ppt / 0.1–5.00%
Salinity Resolution0.1 ppt / 0.01%
Salinity Accuracy±1% of full scale
Temperature Range−10.0 to 110.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
Temperature CompensationATC/MTC (0–50 °C)
Adjustable Temperature Coefficient0.0–3.0 %/°C
Reference Temperatures20.0 °C or 25.0 °C (selectable)
Cell Constant1.0 cm⁻¹
Data Hold FunctionYes
Auto Power-OffAfter 20 min of inactivity
Power Supply4 × 1.5 V AAA batteries
Dimensions (Instrument)14 × 17 × 3.5 cm
Weight (Instrument)200 g
Dimensions (Packaging)24 × 17 × 8 cm
Weight (Packaging)550 g
ComplianceDesigned for GLP-compliant field and lab use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCHI
OriginSwitzerland
ModelR-210 / R-215
Rotation Speed20–280 rpm
Bath Temperature Range+20°C to +180°C (B-491) or +20°C to +95°C (B-495)
Evaporation Flask Capacity50–4000 mL
Max. Flask Weight3 kg
DisplayBasic (R-210) / Steam Temperature & Rotation Speed (R-215)
Vacuum PumpV-700 (1.8 m³/h, <10 mbar final vacuum) or V-710
Vacuum ControllerV-850 (standard) / V-855 (advanced, with pressure gradient programming & EasyVac)
IP RatingIP21
Power Supply100–240 V, 50/60 Hz
Dimensions (L×H×D)550 × 575 × 415 mm
Weight16–18 kg (without bath)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelHistoCore PEARL
Enclosed Processing Capacity200 cassettes per cycle
Safety SystemTriple-stage exhaust management (integrated vacuum draw, external venting port, activated carbon filter)
User InterfaceXylene-resistant capacitive touchscreen with multilingual support (EN/DE/FR/ES/IT)
Data ManagementUSB-exportable audit-trail log files compliant with GLP documentation requirements
Reagent MonitoringIntegrated Reagent Management System (RMS) tracking usage by cassette count, cycle count, or elapsed days
Physical DimensionsCompact footprint optimized for space-constrained histology labs
Certified ComplianceCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEsco
OriginSingapore
Instrument TypeClass II Type A2 Biological Safety Cabinet
External Dimensions (L×W×H)1340 × 753 × 1400 mm
Internal Dimensions (L×W×H)1220 × 580 × 660 mm
Filter Efficiency≥99.999% for 0.1–0.3 µm particles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Model Numbers07575-10, 77975-20, 07575-82
Speed Range0.1–600 rpm
Speed Accuracy±0.1%
IP RatingIP66
Enclosure RatingNEMA 4X
Housing Material316 Stainless Steel
DisplayBacklit LCD showing flow rate, speed, dispensed volume (mL/L/gal), total dispensed volume, repeat count, and interval time
Flow Control Inputs0–20 mA, 4–20 mA, 0–10 V
Power Supply90–260 V AC, 1.1 A
Dimensions (L×W×H)30.5 × 22.9 × 23.6 cm
CertificationsETL, CE, ISO 9001:2000
Pump Tube CompatibilitySizes 13–36 (ID×OD×WT in mm), including high-pressure options (e.g., Size 36: 9.6×14.4×2.4 mm
Max Flow Rate (with Size 36 tube)0.57–3400 mL/min
Stacking CapacityUp to two pump heads per driver
Software/Control OptionsTouch-key interface with lock function, non-volatile memory for tube calibration data, bidirectional operation, programmable dispensing cycles (1–99,999 repeats), adjustable interval timing (up to 99 h 59 min 59 s)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelAQ3010
Measurement Principle90° Nephelometric Detection (ISO 7027 Compliant)
Light SourceInfrared LED
Measurement RangeAuto-ranging 0.01–1000 NTU
Resolution0.01 NTU (0.01–19.99), 0.1 NTU (20.0–99.9), 1 NTU (100–1000)
Accuracy±2% of reading +1 LSD (0–500 NTU)
Response Time<6 s
Sample Volume10 mL
Calibration Standards0.02, 20.0, 100, and 800 NTU EPA-compliant formazin equivalents
Sample Cell25 mm diameter, numbered vials
Protection RatingIP67
Power Supply4 × AAA alkaline batteries (≥3,000 measurements) or lithium (≥12,000 measurements)
Auto-power-offAfter 20 min idle
Operating Temperature0–50 °C (RH 0–90% at 30 °C)
CertificationsCE, TÜV 3-in-1 (CSA-US), FCC Part 15
Self-diagnostic FunctionYes, with error code display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelElix Intelligent Pure Water Module
Price RangeUSD 13,500 – 40,500 (est.)
Purified Water GradeASTM Type II / ISO 3696 Grade 2
Resistivity>10 MΩ·cm @ 25°C
Heavy Metals & Soluble Silica<0.1 ppb
Total Organic Carbon (TOC)<30 ppb (<10 ppb with optional UV-oxidation module)
Microbial Count<0.001 EU/mL
Particles (>0.1 µm)<1 particle/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC1
Temperature Range−150 to 700 °C (configurable low-end: −150, −100, −90, −70 or −35 °C)
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.02–300 K/min (heating), 0.02–50 K/min (cooling)
Heat Flow Sensitivity0.04 µW (FRS5 sensor), 0.01 µW (HSS8 sensor)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJiangsu, China
Distributor StatusAuthorized Distributor
ModelUVM-4020
Instrument TypeOnline Analyzer
Measurement PrincipleWeighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (UV-Vis)
Wavelengths243 nm, 254 nm, 265 nm, 275 nm, and 290 nm (simultaneous acquisition with spectral weighting)
Measurement Ranges0–400 SAC, 0–200 SAC, 0–80 SAC
Cycle TimeMinimum 1 minute
Power Supply220 V ±10 V, 50/60 Hz, ~100 VA
Operating Environment5–40 °C, ≤90% RH (non-condensing, non-freezing)
Sample Flow Rate1–2 L/min
Sample Pressure≤50 kPa
CalibrationAutomated zero/span calibration (optional reagent-free standard solutions)
Conversion FunctionsSimultaneous real-time calculation of COD, BOD, TOC, and SAC using 30 built-in empirical correlation models
CleaningScheduled internal tubing purge via user-defined intervals
InstallationIndoor wall- or rack-mounted configuration
ComplianceDesigned for continuous operation under ISO 5667-3, ASTM D5540, and EPA Method 415.3-aligned monitoring workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Model25750-60
Density Range0–3 g/cm³ (or SGU)
Density Resolution0.01 g/cm³ (or SGU)
Temperature Range0–40 °C
Temperature Resolution0.1 °C
Sample Volume2 mL
Dimensions14.0 × 13.6 × 2.5 cm
Power1.5 V AA battery
InterfaceInfrared output
Data Storage1024 readings
DisplayLarge LCD showing density, specific gravity, % concentration, and sample temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCole-Parmer
OriginUSA
Model05611-21
Flow Range0.26–8 GPM
Accuracy±0.5% of reading
Viscosity Range1–1000 cP
Operating Temperature−5 to 55 °C (23 to 131 °F)
Max Pressure1500 psi
Wetted MaterialsAcetal, aluminum, steel, nitrile
Power SupplyTwo AAA batteries
Battery Life2000 hours
Display6-digit LCD
Connection1/2" NPT(F)
Unitsgal, L, qt, pt
OutputLocal display only (no pulse or remote output)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China-manufactured)
ModelTAdvanced 96SG
Instrument TypeFast Thermal Cycler
Sample Capacity96-well format
Max Heating Rate8 °C/s
Temperature Accuracy±0.1 °C
Well-to-Well Uniformity±0.15 °C
Display7-inch color capacitive touchscreen
Gradient FunctionLinear temperature gradient across 12 columns (spanning up to 40 °C range)
Cooling MethodDual-zone Peltier with bottom intake / rear exhaust airflow
Compatible VesselsStandard 96-well plates, 0.2 mL tubes, and 8-tube strips
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ModelBioShake XP / iQ / 3000 elm / 3000-T
Temperature RangeAmbient to 99 °C
Temp. Accuracy±0.1 °C
Temp. Uniformity±0.5 °C
Heating Rate~7 °C/min (RT to 95 °C in ~10 min)
Orbital Speed (Microplate)200–3000 rpm
Orbital Speed (Tubes)200–1800 rpm
Amplitude2 mm
Speed Resolution50 rpm
Speed Accuracy±25 rpm
Timer Range1 min – 99 h
Timer Resolution1 min
Programmable Protocols2 stored methods, each with up to 3 steps
Dimensions (W×D×H)142 × 170 × 80 mm
Weight2.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
ModelMA100 Series Moisture Analyzer
Measurement Range0.05–100% moisture content
Readability0.001%
Weighing Precision0.1 mg
Heating OptionsCeramic IR heater, halogen lamp, quartz CQR heater
Heating ModesStandard, Rapid, Gentle, Step (3 stages × 0.1–999 min)
Analysis ModesFully automatic, semi-automatic, timed (3 × 0.1–999 min), timed + auto/semi-auto (2 × 0.1–999 min + auto)
Built-in Calibration WeightYes
Reproducibility Test Function (reproTEST)Yes
Programmable Methods30
Data Storage CapacityUp to 9,999 measurement records
ComplianceEC Type Approval Certificate, DIN/ISO-compliant automatic calibration and validation routines
InterfaceRS-232, optional barcode scanner support
FDA/HACCP CompatibilityRequires YDS03MA adapter kit
GLP/GMP-Ready Print OutputYes, user-configurable
Password ProtectionYes
Dust-Protected KeypadYes
Operating Temperature RangeAmbient to 180 °C (adjustable in 1 °C increments)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0