- All
- Favorite
- Popular
- Most rated
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | CVE-2000 |
| Rotational Speed | 1400 rpm (fixed) |
| Temperature Control Range | Ambient +5°C to 80°C |
| Ultimate Vacuum (internal pump) | 3 kPa |
| Ultimate Vacuum (external pump) | ≤1.33 kPa |
| Chamber Dimensions | Ø160 mm × H105 mm |
| Rotor Capacity | 24 × 1.5 mL microtubes (Ø10.8 mm) |
| Chamber & Tubing Material | Chemically Resistant Polymer Alloy |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | COND600 |
| Origin | USA |
| Instrument Type | Portable Conductivity/TDS/Temp Meter |
| IP Rating | IP67 |
| GLP Compliance | Yes |
| Measurement Principles | Two-electrode AC conductivity, temperature-compensated TDS calculation (linear α coefficient), NIST-traceable calibration |
| Key Ranges | Conductivity 0–200.0 mS/cm (5-range auto-ranging) |
| Resolution | 0.01 µS/cm (low range) to 0.1 mS/cm (high range) |
| Accuracy | ±1% of full scale + 1 LSD (conductivity & TDS) |
| Calibration | Up to 4-point automatic or 5-point manual using standard KCl solutions |
| Temperature Compensation | Linear, user-selectable α (0.00 to 10.00 %/°C), default 2.00 %/°C |
| Electrode Constant Range | 0.010–10.000 cm⁻¹ |
| Data Storage | 500 measurement sets with timestamp, temperature, and electrode ID |
| Connectivity | RS-232C serial port, IrDA infrared interface |
| Power | 4×AA alkaline batteries (≥200 h operation) or optional 9 V DC adapter (500 mA) |
| Dimensions (unit) | 18.3 × 9.5 × 5.7 cm |
| Weight (unit) | 460 g |
| Operating Environment | 0–50 °C, ≤95% RH non-condensing |
| Storage Environment | −25–70 °C |
| Display | Backlit LCD (5.4 × 7.1 cm active area), multi-parameter real-time view |
| Auto-off | Configurable 2–30 min idle timeout |
| Auto-hold | Yes |
| Certifications | CE, RoHS, FCC Class B |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion KF Flex / Pro |
| Heating Method | Infrared |
| Sample Capacity | 24 positions on 25 cm footprint |
| Gas Flow Control | Digital mass flow meter (air or lab-line gas) |
| Temperature Program | Temperature ramping and isothermal scanning |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation (when paired with compatible titrators) |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Elix Advantage |
| Price Range | USD 6,500 – 13,000 (est.) |
| Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Optional Tank Capacities | 30 L, 60 L, 100 L |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric/Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (V20S: volumetric |
| V30S | coulometric, down to 1 ppm) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Control Precision | 20,000 steps |
| Compliance | Designed for GLP/GMP environments with audit trail capability per FDA 21 CFR Part 11 requirements |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 05628-00 |
| Power Supply | 12–24 V AC/DC, 50/60 Hz |
| Display | 2-line × 16-character alphanumeric LCD with backlight |
| Relays | 2 × SPDT (5 A @ 250 V AC / 30 V DC) |
| Analog Output | 4–20 mA (non-isolated) |
| Pulse Output | EOB (End-of-Batch) for remote start/stop/resume |
| Input Frequency Range | 5–1000 Hz (optically isolated) |
| Operating Temperature | –10 to 55 °C (14 to 131 °F) |
| Enclosure Dimensions | 89 mm × 89 mm × 89 mm (3.5" × 3.5" × 3.5") |
| Mounting | Panel-mount with included bracket and adhesive template |
| Memory | Non-volatile EEPROM for configuration retention during power loss |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | 1634 |
| Dimensions (W×D×H) | 1800 mm × 500 mm × 2115 mm |
| Import Status | Imported |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 77111-80 |
| Price | Upon Request |
| Drive Type | Pneumatic |
| Max. Fluid Viscosity | 10,000 cP |
| Speed Range | 35–321 rpm |
| Flow Rate (with BT-87 tubing) | 1.9–17.7 L/min |
| Flow Rate (with BT-91 tubing) | 4.0–37.0 L/min |
| Air Supply Requirement | 340 L/min at ≥2.7 bar |
| Motor Power Equivalent | 0.75 hp (560 W) |
| Enclosure Rating | IP56 |
| Certifications | CE, CUL, ATEX Zone 2 (EEx II 3Gc IIC T6), NEC Class I, Div. 2, Groups A,B,C,D,T6 |
| Dimensions (L×W×H) | 68.6×40.0×38.4 cm |
| Standard Tubing | Tygon LFL #91, 0.9 m |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | ST5010-CV5030 |
| Automation Level | Fully Automatic |
| Instrument Type | Rotary (Carousel-Based) |
| Throughput Capacity | 3 Slide Racks per Load |
| Design Integration | Seamless Interface with Leica Autostainer XL |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010 Pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | –250 to +250 °C/min (programmable) |
| Oven Cool-down Time | ≤3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (7-segment programming) |
| Carrier Gas Pressure Range & Control | 0–1035 kPa (7-segment programming) |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Salt6+ |
| Measurement Principle | Conductivity-based salinity determination with automatic temperature compensation (ATC) |
| Salinity Range | 1.0–50.0 ppt / 0.1–5.00% |
| Salinity Resolution | 0.1 ppt / 0.01% |
| Salinity Accuracy | ±1% of full scale |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | ATC/MTC (0–50 °C) |
| Adjustable Temperature Coefficient | 0.0–3.0 %/°C |
| Reference Temperatures | 20.0 °C or 25.0 °C (selectable) |
| Cell Constant | 1.0 cm⁻¹ |
| Data Hold Function | Yes |
| Auto Power-Off | After 20 min of inactivity |
| Power Supply | 4 × 1.5 V AAA batteries |
| Dimensions (Instrument) | 14 × 17 × 3.5 cm |
| Weight (Instrument) | 200 g |
| Dimensions (Packaging) | 24 × 17 × 8 cm |
| Weight (Packaging) | 550 g |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | R-210 / R-215 |
| Rotation Speed | 20–280 rpm |
| Bath Temperature Range | +20°C to +180°C (B-491) or +20°C to +95°C (B-495) |
| Evaporation Flask Capacity | 50–4000 mL |
| Max. Flask Weight | 3 kg |
| Display | Basic (R-210) / Steam Temperature & Rotation Speed (R-215) |
| Vacuum Pump | V-700 (1.8 m³/h, <10 mbar final vacuum) or V-710 |
| Vacuum Controller | V-850 (standard) / V-855 (advanced, with pressure gradient programming & EasyVac) |
| IP Rating | IP21 |
| Power Supply | 100–240 V, 50/60 Hz |
| Dimensions (L×H×D) | 550 × 575 × 415 mm |
| Weight | 16–18 kg (without bath) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | HistoCore PEARL |
| Enclosed Processing Capacity | 200 cassettes per cycle |
| Safety System | Triple-stage exhaust management (integrated vacuum draw, external venting port, activated carbon filter) |
| User Interface | Xylene-resistant capacitive touchscreen with multilingual support (EN/DE/FR/ES/IT) |
| Data Management | USB-exportable audit-trail log files compliant with GLP documentation requirements |
| Reagent Monitoring | Integrated Reagent Management System (RMS) tracking usage by cassette count, cycle count, or elapsed days |
| Physical Dimensions | Compact footprint optimized for space-constrained histology labs |
| Certified Compliance | CE-marked |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Instrument Type | Class II Type A2 Biological Safety Cabinet |
| External Dimensions (L×W×H) | 1340 × 753 × 1400 mm |
| Internal Dimensions (L×W×H) | 1220 × 580 × 660 mm |
| Filter Efficiency | ≥99.999% for 0.1–0.3 µm particles |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model Numbers | 07575-10, 77975-20, 07575-82 |
| Speed Range | 0.1–600 rpm |
| Speed Accuracy | ±0.1% |
| IP Rating | IP66 |
| Enclosure Rating | NEMA 4X |
| Housing Material | 316 Stainless Steel |
| Display | Backlit LCD showing flow rate, speed, dispensed volume (mL/L/gal), total dispensed volume, repeat count, and interval time |
| Flow Control Inputs | 0–20 mA, 4–20 mA, 0–10 V |
| Power Supply | 90–260 V AC, 1.1 A |
| Dimensions (L×W×H) | 30.5 × 22.9 × 23.6 cm |
| Certifications | ETL, CE, ISO 9001:2000 |
| Pump Tube Compatibility | Sizes 13–36 (ID×OD×WT in mm), including high-pressure options (e.g., Size 36: 9.6×14.4×2.4 mm |
| Max Flow Rate (with Size 36 tube) | 0.57–3400 mL/min |
| Stacking Capacity | Up to two pump heads per driver |
| Software/Control Options | Touch-key interface with lock function, non-volatile memory for tube calibration data, bidirectional operation, programmable dispensing cycles (1–99,999 repeats), adjustable interval timing (up to 99 h 59 min 59 s) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | AQ3010 |
| Measurement Principle | 90° Nephelometric Detection (ISO 7027 Compliant) |
| Light Source | Infrared LED |
| Measurement Range | Auto-ranging 0.01–1000 NTU |
| Resolution | 0.01 NTU (0.01–19.99), 0.1 NTU (20.0–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading +1 LSD (0–500 NTU) |
| Response Time | <6 s |
| Sample Volume | 10 mL |
| Calibration Standards | 0.02, 20.0, 100, and 800 NTU EPA-compliant formazin equivalents |
| Sample Cell | 25 mm diameter, numbered vials |
| Protection Rating | IP67 |
| Power Supply | 4 × AAA alkaline batteries (≥3,000 measurements) or lithium (≥12,000 measurements) |
| Auto-power-off | After 20 min idle |
| Operating Temperature | 0–50 °C (RH 0–90% at 30 °C) |
| Certifications | CE, TÜV 3-in-1 (CSA-US), FCC Part 15 |
| Self-diagnostic Function | Yes, with error code display |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Elix Intelligent Pure Water Module |
| Price Range | USD 13,500 – 40,500 (est.) |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >10 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb (<10 ppb with optional UV-oxidation module) |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1 |
| Temperature Range | −150 to 700 °C (configurable low-end: −150, −100, −90, −70 or −35 °C) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor), 0.01 µW (HSS8 sensor) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Distributor Status | Authorized Distributor |
| Model | UVM-4020 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Weighted Multi-Wavelength Ultraviolet Absorption Spectrophotometry (UV-Vis) |
| Wavelengths | 243 nm, 254 nm, 265 nm, 275 nm, and 290 nm (simultaneous acquisition with spectral weighting) |
| Measurement Ranges | 0–400 SAC, 0–200 SAC, 0–80 SAC |
| Cycle Time | Minimum 1 minute |
| Power Supply | 220 V ±10 V, 50/60 Hz, ~100 VA |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing, non-freezing) |
| Sample Flow Rate | 1–2 L/min |
| Sample Pressure | ≤50 kPa |
| Calibration | Automated zero/span calibration (optional reagent-free standard solutions) |
| Conversion Functions | Simultaneous real-time calculation of COD, BOD, TOC, and SAC using 30 built-in empirical correlation models |
| Cleaning | Scheduled internal tubing purge via user-defined intervals |
| Installation | Indoor wall- or rack-mounted configuration |
| Compliance | Designed for continuous operation under ISO 5667-3, ASTM D5540, and EPA Method 415.3-aligned monitoring workflows |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 25750-60 |
| Density Range | 0–3 g/cm³ (or SGU) |
| Density Resolution | 0.01 g/cm³ (or SGU) |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.1 °C |
| Sample Volume | 2 mL |
| Dimensions | 14.0 × 13.6 × 2.5 cm |
| Power | 1.5 V AA battery |
| Interface | Infrared output |
| Data Storage | 1024 readings |
| Display | Large LCD showing density, specific gravity, % concentration, and sample temperature |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 05611-21 |
| Flow Range | 0.26–8 GPM |
| Accuracy | ±0.5% of reading |
| Viscosity Range | 1–1000 cP |
| Operating Temperature | −5 to 55 °C (23 to 131 °F) |
| Max Pressure | 1500 psi |
| Wetted Materials | Acetal, aluminum, steel, nitrile |
| Power Supply | Two AAA batteries |
| Battery Life | 2000 hours |
| Display | 6-digit LCD |
| Connection | 1/2" NPT(F) |
| Units | gal, L, qt, pt |
| Output | Local display only (no pulse or remote output) |
| Brand | Analytik Jena |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | TAdvanced 96SG |
| Instrument Type | Fast Thermal Cycler |
| Sample Capacity | 96-well format |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Display | 7-inch color capacitive touchscreen |
| Gradient Function | Linear temperature gradient across 12 columns (spanning up to 40 °C range) |
| Cooling Method | Dual-zone Peltier with bottom intake / rear exhaust airflow |
| Compatible Vessels | Standard 96-well plates, 0.2 mL tubes, and 8-tube strips |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | BioShake XP / iQ / 3000 elm / 3000-T |
| Temperature Range | Ambient to 99 °C |
| Temp. Accuracy | ±0.1 °C |
| Temp. Uniformity | ±0.5 °C |
| Heating Rate | ~7 °C/min (RT to 95 °C in ~10 min) |
| Orbital Speed (Microplate) | 200–3000 rpm |
| Orbital Speed (Tubes) | 200–1800 rpm |
| Amplitude | 2 mm |
| Speed Resolution | 50 rpm |
| Speed Accuracy | ±25 rpm |
| Timer Range | 1 min – 99 h |
| Timer Resolution | 1 min |
| Programmable Protocols | 2 stored methods, each with up to 3 steps |
| Dimensions (W×D×H) | 142 × 170 × 80 mm |
| Weight | 2.7 kg |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | MA100 Series Moisture Analyzer |
| Measurement Range | 0.05–100% moisture content |
| Readability | 0.001% |
| Weighing Precision | 0.1 mg |
| Heating Options | Ceramic IR heater, halogen lamp, quartz CQR heater |
| Heating Modes | Standard, Rapid, Gentle, Step (3 stages × 0.1–999 min) |
| Analysis Modes | Fully automatic, semi-automatic, timed (3 × 0.1–999 min), timed + auto/semi-auto (2 × 0.1–999 min + auto) |
| Built-in Calibration Weight | Yes |
| Reproducibility Test Function (reproTEST) | Yes |
| Programmable Methods | 30 |
| Data Storage Capacity | Up to 9,999 measurement records |
| Compliance | EC Type Approval Certificate, DIN/ISO-compliant automatic calibration and validation routines |
| Interface | RS-232, optional barcode scanner support |
| FDA/HACCP Compatibility | Requires YDS03MA adapter kit |
| GLP/GMP-Ready Print Output | Yes, user-configurable |
| Password Protection | Yes |
| Dust-Protected Keypad | Yes |
| Operating Temperature Range | Ambient to 180 °C (adjustable in 1 °C increments) |
Show next