GreenPrima Aqualysis 800A Total Alkalinity Analyzer
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered externally/flow-synchronized |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
Overview
The GreenPrima Aqualysis 800A Total Alkalinity Analyzer is an industrial-grade, fully automated online analyzer engineered for continuous or interval-based quantification of total alkalinity in aqueous process streams. It operates on the principle of titrimetric colorimetry—where a standardized acid titrant is precisely dosed into the sample until a pH-sensitive indicator undergoes a stoichiometric color transition, detected by a high-stability photometric sensor. This method conforms to established titration-based alkalinity standards including ISO 9963-1, ASTM D1067, and APHA Standard Method 2320 B. Designed for deployment in demanding utility and pharmaceutical water systems, the Aqualysis 800A delivers traceable, reproducible measurements without operator intervention—enabling real-time feedback for lime softening, ion exchange regeneration, and boiler feedwater conditioning control loops.
Key Features
- Robust titrimetric colorimetric measurement architecture with dual-wavelength photometric detection for enhanced interference rejection
- Automatic calibration and system diagnostics—including reagent depletion alerts, pump stroke validation, and optical path integrity checks
- Compact footprint (400 × 300 × 180 mm) and lightweight design (4 kg) optimized for panel mounting or skid integration
- Low operational cost profile: minimal reagent consumption (6 months between maintenance cycles)
- Flexible operation modes: continuous monitoring or programmable interval analysis (1–360 minutes), plus external trigger capability via digital input or flow-pulse synchronization
- Configurable rinse protocol (15–1800 seconds) to prevent cross-contamination and maintain long-term baseline stability
- Four programmable relay outputs supporting alarm staging, pump control, or softener backwash initiation; one isolated 4–20 mA analog output for PLC/HMI integration
- Comprehensive local data logging—including measurement history, fault timestamps, calibration records, and diagnostic event logs—with non-volatile memory retention
Sample Compatibility & Compliance
The Aqualysis 800A is validated for use with low-turbidity, non-oily water matrices meeting specified chemical and physical constraints: pH 4–10, dissolved iron < 3 ppm, copper < 0.2 ppm, aluminum < 0.1 ppm, and manganese < 0.2 ppm. It supports operation across a pressure range of 0.2–5 bar (recommended 1–2 bar) and accommodates sample temperatures from 5–40 °C. The analyzer meets IP65 ingress protection for dust- and water-resistant enclosure performance, enabling installation in mechanical rooms, utility corridors, and outdoor instrument shelters. Its firmware architecture supports audit-trail generation and user-access-level configuration—facilitating alignment with GMP Annex 11, FDA 21 CFR Part 11 (when paired with compliant SCADA), and ISO/IEC 17025 quality management requirements.
Software & Data Management
The embedded controller features a menu-driven color LCD interface with multilingual support (English, German, French, Spanish). All configuration parameters—including measurement units (°dH, °f, ppm CaCO₃, mmol/L), sampling frequency, rinse duration, alarm thresholds, and relay logic—are accessible locally or remotely via Modbus RTU over RS485. Data export is supported through ASCII-formatted serial dumps or periodic register polling. Internal storage retains ≥30 days of high-resolution measurement data (1-minute intervals) and full diagnostic logs. Optional integration with GreenPrima’s MCS-series multi-channel selector enables centralized monitoring of up to eight independent sample points—ideal for cooling tower arrays or multi-boiler plant configurations.
Applications
- Real-time alkalinity control in industrial boiler feedwater systems to prevent caustic embrittlement and scale formation
- Monitoring softener effluent quality during sodium cycle regeneration and hardness breakthrough detection
- Process assurance in pharmaceutical purified water (PW) and water-for-injection (WFI) distribution loops per USP and EU GMP Annex 1
- Performance verification of lime-soda ash softening units in municipal and industrial pretreatment plants
- Trend analysis and early warning of carbonate system imbalance in recirculating cooling water systems (per CTI Guidelines and ASHRAE 12–2022)
- Regulatory compliance reporting for EPA NPDES discharge permits requiring alkalinity monitoring
FAQ
What measurement principle does the Aqualysis 800A employ?
It uses titrimetric colorimetry based on acid–base neutralization with a bromocresol green–methyl red indicator system, detecting the endpoint photometrically.
Can the analyzer operate unattended for extended periods?
Yes—designed for >6 months of uninterrupted operation with scheduled reagent replacement and annual verification per ISO/IEC 17025 guidelines.
Is remote configuration and data retrieval supported?
Yes, via Modbus RTU over RS485; no proprietary software required for basic parameter access or log extraction.
How does the unit handle sample interferences such as turbidity or metal ions?
Pre-filtration (5 µm recommended) and adherence to specified metal concentration limits ensure photometric accuracy; built-in blank correction compensates for minor background absorbance.
What certifications apply to the Aqualysis 800A for regulated environments?
CE-marked per EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU; documentation package includes Declaration of Conformity, Factory Calibration Certificate, and IQ/OQ-ready test protocols.