Empowering Scientific Discovery

Lihero IDLIN 700 AI-Powered Fully Automated Water Quality Analysis System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Lihero
Origin Hunan, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model IDLIN 700
Pricing Available Upon Request

Overview

The Lihero IDLIN 700 AI-Powered Fully Automated Water Quality Analysis System is an integrated laboratory automation platform engineered for high-throughput, traceable, and regulatory-compliant water quality testing. Built upon a modular robotic architecture, the system implements standardized wet-chemistry analytical methods—including spectrophotometry, ion-selective electrode (ISE) measurement, titration, and colorimetric assays—in accordance with ASTM D1129, ISO 5667, and EPA Methods 365.3, 311.1, and 300.0. It operates as a closed-loop, networked instrumentation ecosystem comprising an automated sample handler, robotic arm-based sample positioning, programmable liquid handling modules, multi-channel analyzers, centralized control software, and integrated QC tracking. Designed for municipal water utilities, environmental monitoring labs, and industrial effluent compliance facilities, the IDLIN 700 supports unattended operation for up to 24 hours per cycle, delivering reproducible results across routine parameters such as COD, NH₃-N, TP, TN, and turbidity—without operator intervention beyond initial setup and maintenance.

Key Features

  • Fully integrated workflow: Combines automated sample preparation (filtration, dilution, digestion), reagent dispensing, reaction incubation, optical/electrochemical detection, and result calculation in a single platform.
  • Modular analyzer architecture: Supports hot-swappable analytical modules compliant with ISO/IEC 17025 method validation requirements; each module is independently calibrated and traceable to NIST-certified reference materials.
  • Intelligent scheduling engine: Dynamically allocates analysis resources based on sample priority, parameter complexity, and instrument availability—enabling mixed-parameter batch processing without cross-contamination risk.
  • Embedded AI-assisted diagnostics: Real-time anomaly detection using multivariate statistical process control (SPC); flags deviations in baseline drift, photometric noise, or electrode response stability before result generation.
  • Comprehensive audit trail: Full GLP/GMP-aligned electronic record retention including user login events, method version history, calibration logs, raw signal data, and timestamped QC flagging—all compliant with FDA 21 CFR Part 11 requirements for electronic signatures and data integrity.

Sample Compatibility & Compliance

The IDLIN 700 accepts standard 16 mm × 100 mm glass or polypropylene vials, as well as 50 mL centrifuge tubes and EPA-compliant 40 mL amber bottles. It accommodates raw surface water, treated drinking water, wastewater influent/effluent, and leachate samples—with optional integration of auto-dilutors for high-concentration matrices. All fluidic pathways are chemically resistant (PTFE, PEEK, borosilicate glass), and wash protocols meet ISO 15195:2018 carryover validation criteria (< 0.1% residual). The system conforms to ISO/IEC 17025:2017 clause 7.2.2 (method validation), EN ISO/IEC 17025:2017 Annex A (uncertainty estimation), and supports full documentation packages required for accreditation audits.

Software & Data Management

Control and data acquisition are managed via Lihero LabOS™ v4.2—a web-native, role-based platform supporting TLS 1.3 encryption, LDAP/Active Directory integration, and configurable SOP-driven workflows. Raw sensor outputs (absorbance, mV, conductivity) are stored in vendor-agnostic HDF5 format with embedded metadata (sample ID, method ID, analyst ID, instrument serial number, environmental conditions). Reporting modules generate PDF/CSV exports compliant with ISO 14001 environmental management reporting and EU WFD (Water Framework Directive) Annex V templates. Optional API endpoints enable bidirectional integration with LIMS (e.g., Thermo Fisher SampleManager, LabVantage) and ERP systems via RESTful JSON payloads.

Applications

  • Regulatory compliance monitoring for municipal drinking water (US EPA Safe Drinking Water Act, EU Directive 98/83/EC)
  • Industrial pretreatment and discharge verification under NPDES permits
  • Environmental impact assessment (EIA) field lab support for river/lake basin studies
  • Research-grade kinetic profiling of nutrient removal in pilot-scale bioreactors
  • QA/QC in bottled water production facilities requiring USP TOC and conductivity verification

FAQ

What standards does the IDLIN 700 comply with for method validation?

It supports validation per ISO/IEC 17025:2017 Annex A, ASTM D5847, and EPA Guidance for Method Validation (2007). All onboard methods include documented LOD/LOQ, precision (RSD ≤ 3.5%), and recovery (85–115%) data.

Can the system integrate with existing LIMS or SCADA infrastructure?

Yes—via secure REST API, OPC UA, or flat-file SFTP push/pull. Pre-built connectors are available for LabWare, STARLIMS, and Siemens Desigo CC.

How is reagent consumption optimized compared to manual benchtop analysis?

Precise microdispensing (±0.5 µL accuracy) and closed-loop rinse recovery reduce reagent use by 40–65%, while waste volume is minimized through segmented flow paths and on-board neutralization modules.

Is remote monitoring and troubleshooting supported?

All units include embedded cellular failover (LTE-M) and encrypted remote desktop access with granular permission controls—enabled only under signed service agreement and customer authorization.

What maintenance intervals are recommended for long-term operational reliability?

Preventive maintenance every 1,000 operational hours includes pump calibration, valve actuation testing, photometer wavelength verification, and ISE membrane replacement—documented in automated PM logs within LabOS™.