- All
- Favorite
- Popular
- Most rated
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Water Environment Integrated Monitoring & Regulatory Platform |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Model | LFSZ-2008 |
| Mounting Platform | Vehicle-integrated mobile laboratory |
| Configuration | Modular, fully automated water analysis system |
| Compliance Framework | Designed for ISO/IEC 17025-aligned operational workflows, supports GLP/GMP traceability requirements (audit trail, sample ID logging, QC event recording) |
| Data Transmission | Real-time secure telemetry to central emergency command platforms via 4G/LTE and optional satellite uplink |
| Analytical Scope | >100 water quality parameters including but not limited to pH, conductivity, turbidity, DO, COD, NH₃-N, TN, TP, heavy metals (As, Cd, Pb, Hg, Cr⁶⁺), organic micropollutants (via onboard GC-MS or UV-Vis spectrophotometric modules), and microbial indicators (ATP-based rapid enumeration) |
| Brand | LiheRO |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Atmospheric Pollution Grid-Based Monitoring and Decision Support System |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Model | LFS-2002 (NO₂) |
| Measurement Principle | N-(1-Naphthyl)ethylenediamine Dihydrochloride Spectrophotometry (ISO 6775, APHA 4500-NO₂⁻ B) |
| Wavelength | 540 nm ± 2 nm |
| Detection Range | 0–1.0 mg/L NO₂⁻-N (extendable to 0–5.0 mg/L with dilution) |
| Detection Limit | ≤ 0.005 mg/L NO₂⁻-N |
| Accuracy | ±5% of reading or ±0.01 mg/L (whichever is greater) |
| Repeatability | RSD ≤ 3% |
| Sample Volume | 10–50 mL |
| Digestion | High-temperature (120°C), high-pressure sealed digestion module |
| Turbidity & Color Compensation | Real-time dual-wavelength optical correction |
| Calibration Modes | Zero check, span check, standard verification, curve auto-calibration, spike recovery test |
| Data Logging | Internal SD card + RS485/Modbus RTU + optional 4G/ETH remote upload |
| Operating System | Embedded Linux (real-time kernel) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| IP Rating | IP65 (enclosure) |
| Compliance | GB/T 32203–2015, HJ 537–2009, ISO 6775:1984, APHA Standard Methods 4500-NO₂⁻ B |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VOCs Mobile Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LFJCC-2010 |
| Power Supply | Dual-mode solar/battery hybrid (24 V DC) |
| Operating Temperature | −10 °C to +50 °C |
| IP Rating | IP68 (submersible enclosure) |
| Communication | 4G LTE + GPS + SMS alert |
| Data Transmission | MQTT/HTTP over cellular network |
| Modular Sensor Capacity | Up to 12 configurable analytical modules |
| Compliance | GB/T 35273–2020 (China National Standard for Environmental Monitoring Equipment), ISO 5667-16:2009 (Water quality — Sampling — Part 16: Guidance on biologically sensitive sampling) |
| Brand | Lihero |
|---|---|
| Model | LFS-2002 (CODMn) |
| Type | Online Analyzer |
| Detection Principle | Potassium Permanganate Oxidation Titration (Acidic & Alkaline Methods) |
| Endpoint Detection | Photometric & Potentiometric Titration |
| Chloride Interference Compensation | Automatic Method Switching (Acidic vs. Alkaline) |
| Self-Diagnosis | Integrated Sensor Health Monitoring, Optical Path Auto-Balancing, Reagent Level & Sample Flow Monitoring |
| Calibration & QA/QC | Automated Zero/Span/Standard Verification, Curve Auto-Calibration, Spike Recovery Test |
| Compliance Support | Designed for ISO 8467, ASTM D1253, and GB/T 5750.7–2006 alignment |
| Remote Operation | Modbus TCP, RS485, and Optional OPC UA Integration |
| Operating System | Embedded Real-Time OS |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Water Environment Automatic Monitoring System O&M Service |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Model | LIS-2013(TA) |
| Measurement Principle | Colorimetric Spectrophotometry or Acid-Base Titration |
| Display | Embedded OS with 7-inch TFT Touchscreen (Chinese UI) |
| Sample Inlet | Positive-Pressure Auto-Sampling System |
| Reagent Consumption | ≤2.5 mL per analysis |
| Reagent Storage | Sealed Cartridge Design, Shelf Life Extended by >40% vs. Open Bottles |
| Data Storage | Internal Flash Memory ≥16 GB (≥12 months of 5-min interval data) |
| Sampling Channels | Up to 4 independent inlets with flow monitoring and dry-run alarm |
| Compliance | Designed for ISO 9001-certified manufacturing |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Enclosure Rating | IP65 |
| Operating Temperature | 5–40 °C |
| Dimensions (W×D×H) | 483 × 450 × 220 mm |
| Weight | 18.5 kg |
| Brand | Lihero |
|---|---|
| Model | LFTOX-B2010 |
| Type | Portable Toxicity Analyzer |
| Measurement Principle | Bioluminescent Bacterial Assay (ISO 11348-3) |
| Microorganism | Freeze-dried *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Reconstitution Time | <5 min |
| Shelf Life (lyophilized) | ≥6 months at ≤−20 °C |
| Working Stability (reconstituted) | 7–10 days at 2–8 °C |
| Detection Range | EC50 from 0.1% to 100% sample dilution (equivalent to broad-spectrum toxicity index) |
| Compliance | ISO 11348-3:2022, DIN 38412-30, EPA 600/R-95/125 |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ART 700 |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Model | NaAl3000 |
| Origin | Hunan, China |
| Instrument Type | Online Process Analytical System for Sodium Aluminate Solutions |
| Application Domain | Bayer Process Monitoring in Alumina Refineries |
| Configuration | Integrated Sampling Subsystem + Analyzer Cabinet with Dilution, Measurement, and Data Acquisition Modules |
| Compliance Context | Designed for continuous operation in Class 1 Div 2 hazardous areas (per NEC/IECEx guidelines) |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | IM Series |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Model | LFGCMS-100 VOCs |
| Origin | Hunan, China |
| Instrument Type | Online GC-MS Analyzer |
| Target Analytes | 116 Speciated Volatile Organic Compounds (VOCs) |
| Regulatory Compliance | HJ 1010–2018 (China) |
| Configuration | Integrated GC-MS with Dual-Stage Differential Turbo-Molecular Pump Vacuum System |
| User Interface | Graphical GUI with Bilingual (Chinese/English) Support |
| Intended Use | Continuous Ambient Air VOC Monitoring |
| Brand | Lihero |
|---|---|
| Model | LIS-2013(HD) |
| Measurement Principle | Colorimetric Spectrophotometry (with optional titrimetric module) |
| Detection Range | 0–500 mg/L as CaCO₃ (configurable) |
| Accuracy | ±5% FS |
| Repeatability | ≤3% RSD |
| Sample Flow Rate | 10–30 mL/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Output Interface | 4–20 mA, RS485 (Modbus RTU), Ethernet |
| Compliance | GB/T 5750.4–2023, ISO 9963-1:1994, ASTM D1126–22 |
| Brand | Lihero |
|---|---|
| Model | LFAQMS-2012 |
| Measurement Principle | UV Absorption (SO₂, O₃), Chemiluminescence (NO₂), Non-Dispersive Infrared (CO) |
| Compliance | HJ 654–2013 |
| Output Channels | 8 configurable alarm relay outputs |
| Data Tagging | Embedded validity flags per measurement record |
| Interface Options | RS232/RS485, Ethernet, Modbus TCP, analog 4–20 mA |
| Calibration Mode | Automated zero/span calibration with manual override capability |
| Brand | Lihero |
|---|---|
| Model | LFS-2002(TP) |
| Type | Online Analyzer |
| Measurement Principle | Peroxysulfate Digestion + Ascorbic Acid-Molybdate Colorimetry |
| Detection Method | Photometric Absorption at 700 nm |
| Compliance | HJ/T 212–2017, GB 11893–1989 |
| Power Supply Insulation Resistance | ≥20 MΩ |
| Communication Interfaces | RS-232 / RS-485 / RJ-45 |
| Operating System | Embedded Linux |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Roadside Mobile Source Monitoring Station |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | LFWAMS-2010 |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | IBOT 500 |
| Pricing | Available Upon Request |
| Capacity | ≥500 mL |
| Communication | Dual-mode (NFC + Cellular/LTE-M) |
| Sensor Integration | Integrated water-level, temperature, conductivity, and valve-status sensors |
| Sampling Modes | Timed, Event-Triggered (depth/conductivity), Remote-Initiated |
| Data Logging | Timestamped lid actuation, valve operation, environmental temperature, GPS trajectory, battery voltage |
| Compliance | Designed for field-deployable environmental monitoring per ISO 5667-1, ASTM D3370, and EPA Method 1664B workflows |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Model | LFMC-2014 |
| Detection Modules | UV-Vis Spectrophotometry (Continuous Spectrum), Electrochemical Sensors, Gas-Phase Colorimetry (Purge-and-Colorimetric), Ion-Selective Electrodes (ISE) |
| Measurement Modes | Simultaneous, Sequential, and Continuous Monitoring |
| Parameter Coverage | ≥32 Parameters per EPA 1600/ISO 5667 & China’s Surface Water Environmental Quality Standard (GB 3838–2002) |
| Sample Introduction | Dual-Path Auto-Sampling with Standard Reference Verification |
| Automation Level | Fully Automated via Robotic Reagent Handler |
| Compliance Support | GLP/GMP-aligned Audit Trail, ISO/IEC 17025 Traceability Framework, USP <621> Chromatographic System Suitability Principles (adapted for wet chemistry platforms) |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Pre-Treatment Unit |
| Pricing | Available Upon Request |
| Brand | Lihero |
|---|---|
| Origin | Hunan, China |
| Model | LFWGC-2012 |
| Instrument Type | Online Water Quality Analyzer for Volatile Organic Compounds (VOCs) |
| Detection Principle | Gas Chromatography with Purge-and-Trap Preconcentration |
| Detectors | FID (Field-Deployable Flame Ionization Detector), ECD |
| Target Analytes | >30 VOCs including halogenated hydrocarbons, BTEX, aldehydes |
| Sample Volume | 10 mL per analysis |
| Calibration | Integrated Automated Calibration Module |
| Compliance | Designed to meet GB 3838–2002 (China Surface Water Environmental Quality Standards), EPA Method 524.2 & 8260D equivalency |
| Remote Control | Yes |
| Data Logging | Full Process Audit Trail with Event Timestamping |
| Brand | Lihero |
|---|---|
| Model | LFS-2002 (LAS) |
| Measurement Principle | Methylene Blue Active Substances (MBAS) Spectrophotometric Method |
| Wavelength | 650 nm ± 2 nm |
| Optical Path | 10 mm quartz cuvette or flow cell |
| Detection Range | 0.05–2.00 mg/L LAS (as MBAS) |
| Resolution | 0.01 mg/L |
| Repeatability | ≤ ±2.0% RSD |
| Calibration | Automatic 2-point calibration with standard reference solutions |
| Cleaning | Programmable automatic rinsing cycle using deionized water |
| Communication Interfaces | RS-232, RS-458, RJ-45 Ethernet |
| Operating System | Real-time embedded Linux |
| Compliance | GB/T 7494–1987, ISO 7875-2:1987, ASTM D2330–18 |