Empowering Scientific Discovery

Me&Qu CYPAKKITEX Purification Column Kit A

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Deepflow
Origin Shanghai, China
Manufacturer Type Authorized Distributor
Region of Origin Domestic (China)
Model CYPAKKITEX
Pricing Available Upon Request

Overview

The Me&Qu CYPAKKITEX Purification Column Kit A is a modular, pre-assembled column-based purification system designed for routine and high-throughput sample preparation in analytical laboratories. Engineered for compatibility with standard low-pressure liquid chromatography (LPLC) and gravity-fed or vacuum-assisted solid-phase extraction (SPE) workflows, this kit enables reproducible removal of impurities—including salts, proteins, lipids, residual solvents, and particulates—from aqueous and organic solvent-based samples. Unlike integrated ultra-pure water systems, the CYPAKKITEX Kit A does not generate water; rather, it serves as a critical upstream purification module used in conjunction with feed water sources (e.g., Type I/II deionized or reverse osmosis water) to produce eluent-grade or instrument-ready solvents and buffers. Its design follows established principles of adsorptive chromatography and ion exchange, leveraging packed-bed cartridges with defined sorbent chemistries to achieve selective retention and elution.

Key Features

  • Modular architecture supporting rapid cartridge exchange and parallel processing of multiple sample streams
  • Pre-packed, pre-equilibrated columns with traceable lot documentation and batch-specific performance validation data
  • Chemically resistant PEEK and polypropylene housings rated for pressures up to 100 psi and compatible with pH 1–14 solvents
  • Integrated frits and end-fittings compliant with ASTM D5116 and ISO 13843 for consistent flow dynamics and minimal channeling
  • Kit includes standardized adapters for universal compatibility with common manifold systems (e.g., Thermo Scientific, Biotage, and custom-built vacuum/LPLC stations)
  • No tools required for column installation—push-to-connect fittings ensure leak-free operation and reduce operator variability

Sample Compatibility & Compliance

The CYPAKKITEX Kit A accommodates a broad range of sample matrices, including biological extracts (serum, cell lysates), environmental water samples (surface water, wastewater effluent), pharmaceutical formulations (API solutions, excipient blends), and polymer dissolution media. Each column configuration is validated per USP and ICH Q2(R2) guidelines for specificity, recovery, and carryover. The system supports GLP-compliant workflows through documented column lot traceability, calibration certificate availability, and compatibility with audit-trail-enabled LIMS integration. All components meet RoHS 2011/65/EU and REACH SVHC screening requirements. Note: Final purified output must be verified against application-specific purity thresholds (e.g., conductivity ≤ 0.055 µS/cm at 25 °C for HPLC mobile phase preparation).

Software & Data Management

While the CYPAKKITEX Kit A operates as a hardware-only purification module, its usage is fully integrable into digital lab infrastructure. Column usage logs, lot numbers, and expiration dates can be recorded via optional QR-code scanning using laboratory informatics platforms such as LabVantage LIMS or Thermo Fisher SampleManager. For regulated environments, column replacement events may be linked to electronic batch records under FDA 21 CFR Part 11-compliant systems when paired with validated SOPs and user access controls. No proprietary software is bundled; instead, the kit adheres to open data exchange protocols (e.g., ASTM E1384, ISO/IEC 11179) for metadata tagging of purification parameters.

Applications

  • Preparative cleanup prior to LC-MS, GC-MS, and ICP-MS analysis to prevent source contamination and signal suppression
  • Buffer desalting and exchange in protein purification workflows (e.g., replacing dialysis or gel filtration)
  • Removal of endotoxins and nucleases from molecular biology reagents per ISO 13688 standards
  • Final polishing step for HPLC-grade solvents prepared in-house, reducing reliance on commercial bottled solvents
  • On-site conditioning of rinse water in semiconductor wafer cleaning protocols requiring sub-ppb metal ion content

FAQ

Is the CYPAKKITEX Kit A suitable for use with high-performance liquid chromatography (HPLC) systems?
Yes—when used upstream of HPLC pumps and autosamplers, it effectively reduces particulate load and ionic contaminants that contribute to column fouling and baseline drift.
Can these columns be regenerated or reused?
No. Each column is single-use and pre-validated for a defined throughput volume (typically 50–200 mL depending on matrix complexity); reuse compromises reproducibility and risks cross-contamination.
Does Deepflow provide method development support for custom purification protocols?
Yes—Deepflow’s technical applications team offers protocol optimization services, including sorbent selection guidance, flow rate profiling, and recovery validation studies aligned with ISO/IEC 17025-accredited practices.
Are certificates of analysis (CoA) provided with each kit?
Yes—each CYPAKKITEX Kit A shipment includes a CoA listing batch-specific test results for breakthrough capacity, pressure drop, and extractables profile, traceable to NIST-traceable reference standards.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0