MKN DTH-100 Dry Block Heater
| Brand | MKN |
|---|---|
| Model | DTH-100 |
| Type | Dry Block Heater (Heating Only) |
| Control | Microprocessor-Based PID Temperature Control |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability @100°C | ≤±0.5°C |
| Block Uniformity @40°C | ≤±0.3°C |
| Display Resolution | 0.1°C |
| Ramp Time | ≤15 min (20°C → 100°C) |
| Max Timer Setting | 99 h 59 min |
| Power Consumption | 150 W |
| Net Weight | 2.2 kg |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Interchangeable Aluminum Heating Blocks | A–L Standard Modules Available |
| Safety Features | Over-Temperature Protection, Auto Fault Detection with Audible Alert, Built-in Temperature Calibration Offset Adjustment |
Overview
The MKN DTH-100 Dry Block Heater is a microprocessor-controlled, solid-state thermal incubation system engineered for precise, reproducible, and contamination-free temperature regulation of samples in sealed tubes or microplates. Unlike water baths—whose open liquid medium poses risks of cross-contamination, evaporation, and microbial growth—the DTH-100 utilizes a thermally optimized aluminum heating block to deliver rapid, uniform conductive heating across multiple sample formats. Its design adheres to fundamental principles of thermal mass transfer and PID-controlled resistive heating, ensuring minimal thermal lag and high repeatability across daily laboratory workflows. The unit operates exclusively in heating mode and is intended for applications requiring stable, non-volatile thermal environments—from nucleic acid denaturation and enzyme reaction incubation to serum coagulation and reagent pre-warming.
Key Features
- High-contrast blue LCD interface with dual independent settings for time and temperature; real-time display of current block temperature and countdown timer
- Rapid thermal response: reaches 100°C from ambient (20°C) in ≤15 minutes, enabled by low-thermal-mass aluminum block architecture and optimized 150 W heating element
- PID-based temperature control with stability of ≤±0.5°C at 100°C and block uniformity of ≤±0.3°C at 40°C—validated per ISO/IEC 17025 traceable protocols
- Built-in temperature calibration offset function, allowing users to adjust displayed values against NIST-traceable reference thermometers without hardware modification
- Integrated safety systems: hardware-level over-temperature cutoff, automatic fault detection with audible alarm, and thermal fuse redundancy
- Compact footprint (270 × 190 × 170 mm) and lightweight construction (2.2 kg) support benchtop integration in space-constrained QC labs, clinical diagnostics suites, and academic teaching laboratories
- Modular block system compatible with 13 standardized configurations (A–L), supporting common consumables including 0.2 mL PCR strips, 1.5/2.0 mL microcentrifuge tubes, 96-well PCR plates, and 15/50 mL conical tubes—with all blocks rated for continuous operation up to 100°C
Sample Compatibility & Compliance
The DTH-100 accommodates a broad spectrum of primary labware via its interchangeable aluminum blocks, eliminating the need for tube adapters or secondary containment. Each block is CNC-machined to exacting tolerances and anodized for chemical resistance and ease of decontamination (autoclavable up to 121°C for non-electronic components). The heater complies with IEC 61010-1:2010 for electrical safety in laboratory equipment and meets RoHS Directive 2011/65/EU for hazardous substance restrictions. While not certified for use in FDA-regulated GMP manufacturing environments as a standalone device, its programmable timer, temperature logging capability (via optional RS232/USB interface), and audit-ready parameter settings align with GLP documentation requirements for method validation and routine QC testing. It supports workflows referenced in USP , CLSI EP05-A3, and ISO 15197:2013 where controlled thermal incubation is specified.
Software & Data Management
The DTH-100 operates as a stand-alone instrument with no embedded operating system or cloud connectivity. All configuration and operation occur through the front-panel interface. For laboratories requiring electronic record retention, optional serial (RS232) or USB-to-serial adapters enable connection to validated third-party data acquisition software compliant with 21 CFR Part 11—supporting user-defined metadata tagging, timestamped temperature logs, and exportable CSV reports. Firmware supports firmware version identification and allows for future updates via manufacturer-provided utility tools. No proprietary drivers or cloud accounts are required; communication follows standard ASCII command protocols compatible with LabVIEW, Python (pySerial), and MATLAB instrumentation toolboxes.
Applications
- DNA denaturation and hot-start PCR setup (pre-incubation at 95°C for Taq polymerase activation)
- Enzyme kinetics assays requiring precise thermal equilibration prior to substrate addition
- Serum clotting studies (37°C incubation for coagulation cascade analysis)
- Cell lysis buffer pre-warming to minimize cold-shock artifacts
- Standard curve preparation in ELISA and immunoassay workflows
- Reagent thawing and stabilization prior to HPLC or GC injection
- Quality control testing of temperature-sensitive diagnostic kits under ISO 13485 environmental controls
FAQ
Is the DTH-100 suitable for regulated GMP environments?
It is not supplied with 21 CFR Part 11-compliant software out-of-the-box, but when integrated with validated third-party data acquisition systems and properly documented SOPs, it may be deployed in GMP-adjacent QC labs for non-critical thermal steps.
Can I use custom-designed blocks with this unit?
Yes—Module “M” is designated for customer-specified geometries; dimensional drawings and thermal load specifications must be submitted for engineering review prior to fabrication.
Does the unit support cooling functionality?
No. The DTH-100 is a heating-only dry block heater. For combined heating/cooling applications, refer to the companion MKN DTC-100 model.
What is the recommended maintenance interval?
Visual inspection and cleaning of block wells with isopropyl alcohol every 30 days; annual verification of temperature accuracy using a calibrated NIST-traceable probe is advised.
Are replacement blocks and fuses available as spare parts?
Yes—all standard modules (A–L), thermal fuses, and LCD ribbon cables are stocked and shipped globally with OEM part numbers and full traceability documentation.