Empowering Scientific Discovery

Peak Scientific Genius 3022 Nitrogen Generator for Thermo Scientific Q Exactive Mass Spectrometers

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PEAK
Origin United Kingdom
Manufacturer Type Direct Manufacturer
Import Status Imported
Model Genius 3022
Nitrogen Generation Principle Membrane Separation
Output Flow Rate 2 × 32 L/min
Output Pressure 116 psi (8.0 bar)
Nitrogen Purity Up to 99.5%
Dew Point –40 °C
Power Supply 230 V ±10% AC, 50/60 Hz, 12 A
Dimensions (H×W×D) 1322 × 600 × 850 mm
Weight 189 kg

Overview

The Peak Scientific Genius 3022 is an engineered nitrogen generator specifically co-developed with Thermo Scientific to meet the stringent gas supply requirements of the Q Exactive series of high-resolution hybrid quadrupole-Orbitrap mass spectrometers. Utilizing proprietary hollow-fiber membrane separation technology, the Genius 3022 extracts high-purity nitrogen from compressed ambient air—eliminating dependency on high-pressure cylinders or liquid nitrogen dewars. Its dual independent output channels each deliver a stable 32 L/min at 116 psi (8.0 bar), enabling simultaneous operation of two Q Exactive instruments without cross-contamination or pressure drop. Unlike traditional PSA-based systems, the membrane architecture ensures continuous, pulse-free flow with no adsorbent bed regeneration cycles—critical for maintaining baseline stability during long-duration LC-MS runs. The unit integrates a purpose-built, vibration-damped scroll compressor housed in an acoustically isolated chamber, minimizing mechanical interference with sensitive mass spectrometry instrumentation.

Key Features

  • Dual independent nitrogen outputs—each rated at 32 L/min and 116 psi—supporting concurrent operation of two Thermo Q Exactive systems
  • Membrane-based generation delivers consistent 99.5% nitrogen purity with a certified dew point of –40 °C, meeting ASTM D877 and ISO 8573-1 Class 2:2:2 specifications for instrument-grade gases
  • Integrated low-noise scroll compressor eliminates need for external compressed air infrastructure—reducing installation footprint and complexity
  • Intelligent runtime monitoring with predictive maintenance alerts based on compressor hours, filter saturation, and membrane performance metrics
  • On-demand gas delivery synchronized to instrument demand signals (optional analog/digital I/O interface available)
  • Full-height casters and ergonomic handle enable safe, lab-wide repositioning without disassembly or service interruption
  • 12-month comprehensive on-site warranty covering parts, labor, and preventive maintenance visits

Sample Compatibility & Compliance

The Genius 3022 is validated for use with Thermo Scientific Q Exactive HF-X, Q Exactive Plus, and Q Exactive GC mass spectrometers across all supported ionization modes (ESI, APCI, HESI). It complies with ISO/IEC 17025:2017 requirements for gas supply integrity in accredited testing laboratories. All internal wetted materials—including stainless steel manifolds, fluoropolymer-coated membranes, and EPDM-free filtration media—are compatible with LC-MS mobile phases and meet USP extractables criteria. The system supports GLP/GMP environments through optional audit-trail-enabled firmware (21 CFR Part 11 compliant data logging available upon configuration).

Software & Data Management

While the Genius 3022 operates as a standalone hardware platform, its embedded microcontroller logs operational parameters—including total runtime, filter life remaining, outlet pressure stability, and dew point trends—for export via USB or RS-232. Optional PeakLink™ software enables remote monitoring, threshold-based email/SNMP alerts, and integration into centralized lab infrastructure management systems (LIMS/ELN). All firmware updates are digitally signed and verified to ensure traceability and cybersecurity compliance per IEC 62443-3-3.

Applications

  • Continuous nitrogen supply for electrospray ionization (ESI) and heated electrospray ionization (HESI) sources in high-throughput proteomics and metabolomics workflows
  • Collision gas (CID) and auxiliary gas (sheath gas, sweep gas) for Q Exactive Orbitrap platforms in regulated bioanalysis (e.g., FDA/EMA-compliant PK/PD studies)
  • Backup or primary gas source in multi-instrument LC-MS labs seeking to reduce cylinder logistics, safety risks, and cost-per-liter variability
  • Support for method transfer between sites where gas consistency directly impacts retention time reproducibility and peak shape fidelity
  • Integration into automated sample preparation–LC–MS pipelines requiring uninterrupted gas availability over 72+ hour unattended runs

FAQ

Is the Genius 3022 compatible with non-Thermo mass spectrometers?
Yes—the dual 32 L/min / 116 psi outputs meet the gas specifications of most high-end LC-MS systems from Agilent, Waters, Sciex, and Bruker; however, application-specific validation is recommended.
Does the system require external compressed air?
No—it includes an integrated oil-free scroll compressor and only requires standard 230 V AC power.
How often do filters need replacement?
Pre-filters are rated for 6,000 hours; coalescing and activated carbon filters for 12,000 hours; membrane lifetime exceeds 20,000 hours under typical lab conditions.
Can output pressure be adjusted?
Yes—each channel features independent pressure regulators calibrated from 60 to 116 psi, with factory-set default at 116 psi for Q Exactive compatibility.
What certifications does the unit hold?
CE marked, UKCA compliant, RoHS 2011/65/EU, and tested to EN 61000-6-3 (EMC) and EN 61000-6-2 (immunity) standards.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare