Empowering Scientific Discovery

RWD 80099 Disposable Animal Surgical Drape Pad

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand RWD
Origin Shenzhen, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model 80099
Packaging 100 pieces per pack
Dimensions 40 cm × 50 cm (15.7 in × 19.7 in)
Price Upon Request

Overview

The RWD 80099 Disposable Animal Surgical Drape Pad is a purpose-engineered barrier solution designed for controlled laboratory environments where small- to medium-sized animal surgical procedures are performed. Unlike improvised alternatives such as newspaper, gauze, or generic absorbent pads, this three-layer drape pad provides functionally segmented protection based on fluid dynamics and contamination control principles. Its construction follows the fundamental requirements of biosafety and experimental reproducibility: preventing cross-contamination between specimens, safeguarding sensitive instrumentation from biofluid exposure, and maintaining surface integrity of stainless-steel surgical platforms and laminar flow hoods. The pad operates passively—requiring no power, calibration, or software integration—yet delivers consistent performance across diverse procedural durations and fluid volumes typical in rodent survival surgery, terminal procedures, and teaching-lab dissections.

Key Features

  • Triple-layer architecture: non-woven top layer for tactile stability and surface dryness, high-capacity cellulose/polymer composite core for rapid liquid uptake and lateral wicking suppression, and impermeable polyethylene bottom layer providing full barrier protection against penetration to underlying surfaces
  • Dimensionally stable under wet conditions—maintains structural integrity without curling, tearing, or delamination during prolonged exposure to saline, antiseptic solutions, blood, and excretory fluids
  • Latex-free and DEHP-free formulation compliant with ISO 10993-5 (cytotoxicity) and ISO 10993-10 (irritation/sensitization) standards for short-term biomedical contact
  • Pre-cut, ready-to-use format eliminates on-site cutting errors and reduces preparation time; each pad is individually stacked and sealed in sterile-compatible packaging for inventory control
  • Compatible with standard autoclave cycles (121°C, 15 psi, 20 min) when sterilization is required—though intended primarily for single-use applications in GLP-aligned facilities

Sample Compatibility & Compliance

The RWD 80099 pad supports a broad range of common laboratory animal models, including mice (C57BL/6, BALB/c), rats (Sprague-Dawley, Wistar), rabbits, and guinea pigs. Its 40 cm × 50 cm footprint accommodates stereotaxic frames, heating pads, and integrated anesthesia systems without overhang interference. While not classified as a medical device under FDA 21 CFR Part 820, the product adheres to ISO 13485-aligned manufacturing controls and is routinely validated in academic and contract research organizations (CROs) operating under AAALAC International accreditation requirements. Documentation packages—including material safety data sheets (MSDS), lot-specific test reports, and traceability logs—are available upon request to support audit readiness for IACUC protocols and institutional biosafety committee reviews.

Software & Data Management

As a passive consumable, the RWD 80099 requires no firmware, driver installation, or digital interface. However, its standardized dimensions, batch-coded packaging, and consistent absorption profile enable reliable integration into electronic lab notebook (ELN) workflows. Users may log usage per procedure (e.g., “1 × RWD 80099 used for bilateral ovariectomy in n = 6 C57BL/6 females”) to support retrospective analysis of consumable utilization rates, cost-per-procedure modeling, and environmental impact assessments (e.g., waste volume tracking per IACUC annual reporting). For facilities implementing LIMS-based inventory management, SKU-level barcode scanning (GS1-128) is supported via optional label customization.

Applications

  • Acute and chronic surgical interventions in rodent models, including craniotomy, laparotomy, catheter implantation, and orthopedic fixation
  • Teaching laboratories conducting hands-on anatomy, physiology, and pharmacology modules involving live animal demonstration
  • Non-surgical wet-bench applications requiring localized spill containment—e.g., placement beneath orbital shakers, multi-channel pipettors, centrifuge rotors, and electrophoresis rigs
  • Field-deployable veterinary triage stations where portable, lightweight, and rapidly deployable surface protection is critical
  • Supporting compliance with EU Directive 2010/63/EU Annex IV (housing and care standards) by minimizing environmental stressors associated with uncontrolled fluid dispersion

FAQ

Is the RWD 80099 pad suitable for use with volatile organic solvents such as ethanol or isopropanol?

The polyethylene backing exhibits limited resistance to prolonged exposure (>5 min) to undiluted alcohols; for routine disinfection, we recommend applying 70% ethanol *after* procedure completion and allowing full evaporation prior to disposal.
Can the pad be reused after surface decontamination?

No. The RWD 80099 is engineered for single-use only. Structural compromise and potential microbial retention in the absorbent core preclude safe reuse—even following UV irradiation or chemical wipe-down.
Does the product meet USP bacterial endotoxin limits?

Endotoxin testing is not routinely performed, as the pad is not intended for direct intravascular or intrathecal contact. For applications requiring low-endotoxin consumables, RWD offers separately validated alternatives under catalog number 80102.
What is the shelf life under ambient storage conditions?

Three years from date of manufacture when stored at 15–25°C and relative humidity <60%, protected from direct sunlight and ozone exposure.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0