Empowering Scientific Discovery

Schmidt+Haensch Polartronic N/M TOUCH Polarimeter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Schmidt+Haensch
Origin Germany
Model Polartronic N/M TOUCH
Measurement Range ±360° / ±259°Z (N) and ±360° / ±259°Z (M)
Resolution 0.01° / 0.05°Z (N), 0.001° / 0.01°Z (M)
Accuracy ±0.01° / ±0.05°Z (N), ±0.005° / ±0.015°Z (M)
Repeatability ±0.01° / ±0.05°Z (N), ±0.005° / ±0.015°Z (M)
Wavelength Options 405, 435, 546, 578, 589, 633, 882 nm (fixed or dual selectable)
Response Time <4 s across full range
Temperature Range 0–99 °C
Temp. Accuracy ±0.03 °C
Temp. Resolution 0.01 °C
Light Source Long-life LED (>100,000 h) with optical filters
Detector Integrated photoelastic modulator (PEM)-based polarimetric sensor
Compliance OIML R 107, ASTM E1254, USP <781>, EP 2.2.7, JP 2.05, ICUMSA Methods, Australian Standard K157
Software GLP/GMP-compliant data management with 21 CFR Part 11 audit trail capability
Display 7-inch capacitive TFT touchscreen
Housing Rugged anodized aluminum enclosure
Calibration PTB-certified quartz control plates included
Sample Compatibility Standard 100 mm/200 mm cells

Overview

The Schmidt+Haensch Polartronic N/M TOUCH is a high-precision, dual-configuration digital polarimeter engineered for rigorous quantitative analysis of optically active substances in regulated laboratory and industrial environments. Based on the fundamental principle of optical rotation—where plane-polarized light undergoes angular deviation upon transmission through chiral media—the instrument delivers traceable, temperature-compensated measurements of specific rotation ([α]), observed rotation (α), and concentration-derived units including % w/v, g/100 mL, g/L, and standardized sugar scale (°Z). Its design integrates a stabilized LED light source with narrowband interference filters, a thermally compensated photoelastic modulator (PEM) detection system, and real-time NTC-based sample temperature monitoring. Unlike conventional analog or semi-automatic polarimeters, the Polartronic N/M TOUCH implements continuous angular measurement via dynamic null-balance methodology, enabling true kinetic profiling without mechanical repositioning of the analyzer. This architecture ensures consistent metrological performance across the entire ±360° angular range, with no loss of resolution or accuracy at extreme values—a critical requirement for pharmaceutical assay validation and high-concentration syrup analysis.

Key Features

  • Continuous real-time measurement mode with sub-4-second response time across full angular range (±360°), supporting kinetic reaction monitoring and process concentration tracking
  • Rugged anodized aluminum housing rated for operation in demanding QC/QA laboratories and production floor environments
  • Integrated PEM-based detector and analyzer unit eliminates alignment drift and mechanical hysteresis common in traditional half-shade or double-image systems
  • High-stability LED illumination (>100,000 h lifetime) with selectable fixed wavelengths (405–882 nm) to match pharmacopeial specifications or optimize sensitivity for specific analytes
  • 7-inch capacitive touchscreen interface with intuitive icon-driven navigation, multilingual support (EN/DE/FR/ES), and context-sensitive help
  • Onboard non-volatile memory stores up to 10,000 measurement records with timestamp, temperature, wavelength, and operator ID
  • PTB-certified quartz reference plates supplied as standard for daily verification per ISO/IEC 17025 calibration protocols
  • Comprehensive temperature control integration: NTC sensor embedded in cell holder provides direct sample temperature reading with ±0.03 °C accuracy and 0.01 °C resolution

Sample Compatibility & Compliance

The Polartronic N/M TOUCH accommodates standard 100 mm and 200 mm pathlength cells (10 mm and 22 mm diameters), with optional micro-cell support (down to 0.1 mL volume) available on the M variant. Cell mounting employs precision-ground stainless-steel fixtures with thermal mass stabilization to minimize convection-induced artifacts. Instrument compliance extends across global regulatory frameworks: it meets OIML R 107 metrological requirements for polarimeters, conforms to ASTM E1254 for optical rotation measurement procedures, and satisfies pharmacopeial standards including USP , European Pharmacopoeia 2.2.7, Japanese Pharmacopoeia 2.05, and ICUMSA Method GS3/3-12 for sucrose analysis. All firmware and software modules are validated for GLP and GMP environments, with full 21 CFR Part 11 compliance—including electronic signatures, role-based access control, and immutable audit trails for all measurement, calibration, and configuration events.

Software & Data Management

The embedded PolarSoft™ operating system supports both standalone and networked operation. Measurement data are stored in encrypted SQLite databases with automatic backup to USB drives or network shares. Export formats include CSV, PDF reports (with customizable templates), and XML for LIMS integration. Remote diagnostics and firmware updates are enabled via secure TLS-encrypted Ethernet or Wi-Fi connections, allowing certified service engineers to perform predictive maintenance and calibration verification without onsite visits. Audit trail logs capture user actions, parameter changes, calibration events, and measurement history with tamper-proof timestamps and digital signatures—fully aligned with FDA expectations for data integrity in regulated manufacturing.

Applications

This polarimeter serves as a primary analytical tool across multiple regulated sectors. In pharmaceutical manufacturing, it verifies enantiomeric purity of chiral APIs per ICH Q5A and quantifies active ingredient concentration in liquid dosage forms. In food and beverage QA, it performs routine sucrose determination in syrups, juices, and dairy products per ICUMSA and AOAC methods. In biotechnology, it monitors enzymatic hydrolysis kinetics of glycosidic bonds in real time. Cosmetic raw material suppliers use it to certify batch-to-batch consistency of essential oils and natural extracts. Academic and industrial research labs employ its high-resolution mode (0.001°) for structural elucidation of novel chiral compounds and polymer conformation studies under variable temperature conditions.

FAQ

What wavelength options are factory-configured?
Standard configurations include 589 nm (Na-D line) and 546 nm (Hg-e line); additional wavelengths (405, 435, 578, 633, 882 nm) are available as factory-installed options.
Is temperature control integrated or external?
The instrument includes an embedded NTC sensor in the cell holder for accurate sample temperature measurement; for active temperature regulation, external Peltier or water-jacketed cells are supported via analog/digital I/O interfaces.
Can the Polartronic N/M TOUCH be used for method validation per ICH guidelines?
Yes—its documented measurement uncertainty, traceable calibration chain, and full 21 CFR Part 11 software compliance enable direct use in ICH Q2(R2) analytical procedure validation protocols.
How is calibration verified daily?
Using included PTB-certified quartz control plates (±0.01° accuracy), users perform automated verification routines that generate printable calibration certificates with pass/fail status and deviation metrics.
Does the system support multi-user environments with differentiated permissions?
Yes—role-based access control allows assignment of Operator, Supervisor, and Administrator privileges, with configurable restrictions on data deletion, method editing, and audit trail modification.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0