Empowering Scientific Discovery

Shimadzu GC-2010 Gas Chromatograph Rental System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Shimadzu
Origin Japan
Manufacturer Type Authorized Distributor
Origin Category Imported Instrument
Model ZL-GC-2010
Rental Rate USD 72/day (approx. ¥500/day)

Overview

The Shimadzu GC-2010 Gas Chromatograph Rental System is a high-performance, thermally stable capillary gas chromatograph engineered for precise separation and quantitative analysis of volatile and semi-volatile organic compounds. Based on Shimadzu’s proven GC platform architecture—originally developed in Kyoto, Japan—the instrument employs split/splitless injection, programmable temperature vaporization (PTV), and advanced flame ionization detection (FID) or optional electron capture (ECD), thermal conductivity (TCD), or nitrogen-phosphorus (NPD) detectors. Its robust oven design supports ramp rates up to 250 °C/min and accommodates dual-column configurations for method flexibility. This rental system is fully refurbished, functionally validated, and calibrated per Shimadzu service protocols prior to deployment—ensuring baseline stability, retention time reproducibility (<0.02 min RSD), and peak area precision (<1.5% RSD) across extended operation cycles.

Key Features

  • Fully operational Shimadzu GC-2010 core platform with integrated AOC-20i autoinjector (100-position tray capacity)
  • Temperature-controlled oven with ±0.01 °C stability over 30–450 °C operating range
  • Electronic pressure control (EPC) for carrier gas (He, H₂, N₂) with real-time flow monitoring and compensation
  • Support for ASTM D3606, USP <621>, ISO 17025-compliant chromatographic methods
  • Pre-installed GCsolution Lite software (v2.8 or later) with audit trail capability compliant with FDA 21 CFR Part 11 requirements
  • Rental package includes certified calibration standards, maintenance logbook, and OEM service documentation

Sample Compatibility & Compliance

The GC-2010 rental system accepts liquid, gaseous, and headspace samples via standard 2 mL vials or gas-tight syringes. It is routinely deployed in regulated environments including pharmaceutical QC labs (per ICH Q2(R2)), environmental testing facilities (EPA Method 8260D/8270E), and food safety laboratories (AOAC 2012.01). All instruments undergo pre-rental verification per Shimadzu’s internal QA-100 checklist—including leak testing, detector sensitivity verification (e.g., FID > 5 pg C/sec for n-decane), and column bleed assessment—and are supplied with a Certificate of Functional Verification (CFV). The system meets electromagnetic compatibility (EMC) standards IEC 61326-1 and safety compliance IEC 61010-1.

Software & Data Management

GCsolution Lite provides intuitive method development, sequence control, peak integration, and report generation. All data files are stored in native .gcd format with embedded metadata (operator ID, instrument ID, calibration status, acquisition timestamp). Audit trails record user actions—including method edits, integration parameter changes, and result approvals—with tamper-evident digital signatures. Data export supports CSV, PDF, and XML formats compatible with LIMS integration. Optional upgrade paths to GCsolution Professional include multi-detector synchronization, spectral library search (for GC-MS hybrids), and automated system suitability testing per USP Chapter <621>.

Applications

  • Residual solvent analysis in APIs and excipients (ICH Q3C)
  • VOC profiling in drinking water and soil extracts (EPA 524.2, 8260D)
  • Fatty acid methyl ester (FAME) quantification in biodiesel (ASTM D6584)
  • Pesticide residue screening in fruits and vegetables (EU SANTE/11312/2021)
  • Essential oil composition analysis (ISO 9235)
  • Method validation support for GLP and GMP-regulated studies

FAQ

Is the GC-2010 rental unit supplied with consumables?
Yes—each rental includes one set of certified inlet liners, septa, gold-plated ferrules, and a 30 m × 0.25 mm × 0.25 µm DB-5ms column. Additional consumables are available at distributor-list pricing.
Can the instrument be configured for regulatory submissions?
Yes—when operated with GCsolution Lite and enabled audit trail, the system satisfies ALCOA+ data integrity principles and supports 21 CFR Part 11 compliance when paired with institutional electronic signature infrastructure.
What is the minimum rental duration?
Standard rental terms begin at 30 days; shorter-term deployments (≥7 days) are available with premium rate adjustment.
Is on-site installation and training included?
Basic remote startup assistance is included; on-site commissioning and operator training (8 hours) are available as billable add-ons.
How is instrument performance verified before shipment?
Each unit undergoes full functional test per Shimadzu’s Factory Acceptance Test (FAT) protocol, including retention time repeatability, detector linearity (5-point calibration curve, R² ≥ 0.999), and baseline noise evaluation (<0.05 mV RMS over 30 min).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0