| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | API 4000 Q-Trap |
| Instrument Type | Triple Quadrupole Linear Ion Trap Hybrid |
| Mass Range | 5–2000 m/z |
| Sensitivity | <10 fg on-column for SRM (e.g., reserpine) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Accurate Mass Capability | Not applicable (nominal mass instrument) |
| Ion Source Options | TurboIonSpray® and APCI® with plug-and-play interchangeability |
| Collision Cell | LINAC™ high-efficiency linear accelerator collision cell |
| Detection System | Pulse-counting electron multiplier |
| Dynamic Range | 1–4 × 10⁶ cps |
| Vacuum System | Dual-stage turbomolecular pumps with air-cooled design |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle-free compressed air) |
| Brand | Shimadzu |
|---|---|
| Origin | Italy |
| Model | HT200H Headspace Autosampler |
| Sample Capacity | 40 positions (for 10 mL or 20 mL headspace vials) |
| Sample Heating Block | Simultaneous heating of up to 6 vials |
| Heating Temperature Range | 40–150 °C |
| Heating Time Range | 0–23 h 59 min |
| Agitation Duration | 0–99 min |
| Agitation Speed | Adjustable |
| Syringe Volume | Standard 2.5 mL, optional 5 mL |
| Minimum Injection Volume | 0.01 mL |
| Injection Flow Rate | 0.1–100 mL/min |
| Equilibration Delay | 0–60 s |
| Needle Temperature Control | 40–150 °C |
| Carrier/Purge Gas | Inert gas (N₂ or He) |
| Extraction Mode | Multiple Headspace Extraction (MHE), up to 15 cycles |
| Software Compatibility | HT-Comsoft-H and Clarity Chromatography Data Systems |
| Position Flexibility | Removable sample tray configurable for left- or right-side installation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 1100 Series |
| Instrument Type | Liquid Chromatograph |
| Operational Age | 2–3 years |
| Warranty | 6 months |
| Configuration | Complete system (pump, autosampler, column oven, UV-Vis detector, degasser, controller) |
| Compliance | Fully refurbished to meet Agilent’s pre-owned equipment standards |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 450 °C to 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | JK-JG9000 |
| Price | USD 22,500 (FOB Beijing) |
| Dispersion Method | Wet Dispersion |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Measuring Range | 1–10,000 nm |
| Accuracy | <1% (D50, NIST-traceable standard reference material) |
| Repeatability | <1% (D50, same sample, 3 runs) |
| Laser Source | Fiber-coupled semiconductor laser, λ = 532 nm, lifetime >25,000 h |
| Detector | Hamamatsu high-sensitivity photomultiplier tube (PMT) |
| Scattering Angle | 90° |
| Sample Cell Volume | 4 mL |
| Temperature Control Range | 5–40 °C (±0.1 °C stability) |
| Test Duration | <5 min per run |
| Dimensions | 480 × 270 × 170 mm |
| Weight | 12 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JK-01 Dedicated GC System for Pharmaceutical Residual Solvents |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1100 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | Up to 100 × 2 mL vials (standard tray) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Carryover | <0.05% with needle wash cycle |
| Precision | RSD < 0.3% (typical, 10 µL injection) |
| Temperature Control Range | 4–40 °C (1 °C increment, optional thermostatted models) |
| Maximum Operating Pressure | 400 bar |
| Compatible Formats | 96-well & 384-well microplates, 2 mL vials, 6 mL vials, custom tubes |
| Compliance | Designed for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 7000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Distribution Channel | Authorized Third-Party Reseller |
| Import Status | Imported Instrument |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-17A |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | −50 °C to 450 °C (with optional LN₂ cooling) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | −400 to +400 kPa/min |
| Temperature Accuracy | ±1% of set Kelvin temperature (with 0.01 °C calibration capability) |
| Temperature Stability | 0.01 °C/°C |
| Programmable Temperature Steps | 5 (including cooling ramps) |
| Split Ratio Digital Control Range | 0–400 |
| FID Detection Limit | 5 pg C/s (n-dodecane) |
| FID Dynamic Range | 10⁷ |
| NPD (FTD) Detection Limits | 0.4 pg N/s (azobenzene), 0.05 pg P/s (tributyl phosphate) |
| NPD Dynamic Range | 10⁴ |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | UV-2401 |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.05% |
| Detector | Photodiode Array |
| Automation | Motorized Wavelength Scanning |
| Optical System | Single Monochromator with Holographic Grating |
| Baseline Flatness | ±0.001 Abs (2 nm slit, low scan speed) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.3%T |
| Photometric Range | Abs: –4 to +5 Abs |
| %T | 0.0–999.9% |
| Scan Speed | Up to 3200 nm/min (wavelength shift) |
| Response Time | Auto-optimized (min. 0.1 s) |
| Resolution | 0.1 nm |
| Operating Environment | 15–35 °C, 45–80% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz, 250 VA |
| Dimensions | 570 × 660 × 275 mm |
| Weight | ~36 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC6890N |
| Pricing | Available Upon Request |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 3000 |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | 10–3000 Da |
| Sensitivity | S/N ≥ 100:1 for 1 pg on-column reserpine (ESI+) |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Ion Sources | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle-filtered compressed air) |
| Vacuum System | Varian DS602 dual-stage rotary vane pump with oil mist filter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ICS-2100 |
| Instrument Type | Laboratory Benchtop IC System |
| Pump Pressure Rating | Up to 35 MPa (5,000 psi) |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Range | 0.1–3.0 mL/min |
| Operating Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Column Compatibility | 2 mm and 4 mm internal diameter columns |
| Detector | Suppressed Conductivity Detection (with SRS-300 continuous regeneration micro-membrane suppressor) |
| Data Acquisition Interface | USB 2.0 |
| Software Platform | Chromeleon 6.8 Chromatography Data System (CDS) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-20A |
| Instrument Type | HPLC System |
| Age Range | 5–8 years |
| Warranty | 1 year |
| Category | Second-hand Analytical Instrument |
| Compliance | Import-class, CE-marked configuration (as supplied) |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | 722-1 |
| Price | USD 70 (est.) |
| Optical Design | Single-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 330–1000 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.1% T |
| Wavelength Repeatability | 1 nm |
| Photometric Accuracy | ≤±0.5% T |
| Photometric Repeatability | ±0.2% T |
| Transmittance Range | 0–200% T |
| Absorbance Range | –0.301 to 3.000 A |
| Concentration Range | 0–99999 units |
| Baseline Stability | ±0.001 A/h |
| Output Interface | RS-232 |
| Optional Accessories | Thermal Printer, Dedicated PC Software |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 2695 |
| Product Category | Chromatography |
| Operational Age | 2–3 Years |
| Warranty | 6 Months |
| Price Range | USD 8,200 – 11,000 (FOB China Port) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | UV-3600 |
| Optical Design | Double-Beam (Pseudo-Double-Beam) |
| Instrument Type | Ultraviolet-Visible Spectrophotometer |
| Compliance | Designed to meet ISO/IEC 17025-relevant optical performance criteria for routine laboratory quantification and spectral characterization |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 1100 |
| Instrument Type | Fast Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Sample Tray Capacity | 100 positions (1.5 mL vials) |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WFX-120B |
| Price | USD 4,200 (FOB Beijing) |
| Product Category | Optical Spectroscopy |
| Operational Age | 6–8 years |
| Warranty | 6 months limited parts & labor |
| Instrument Type | Flame AAS |
| Flame Temperature Range | 2300–2950 °C (adjustable) |
| Wavelength Range | 190–900 nm |
| Grating Density | 1800 lines/mm |
| Focal Length | 277 mm |
| Blazed Wavelength | 250 nm |
| Spectral Bandwidth | Multi-step automatic switching |
| Atomizer | 10 cm single-slit titanium burner |
| Nebulizer | Metal-sheathed high-efficiency glass nebulizer |
| Sample Uptake Rate | 6–7 mL/min |
| Background Correction | D₂-lamp (≥30× at 1 Abs) and Self-Reversal (≥30× at 1.8 Abs) |
| Detector | Wide-spectral-range photomultiplier tube (PMT) |
| Lamp System | 6-position auto-switching turret (2 positions compatible with high-performance hollow cathode lamps) |
| Lamp Current Drive | 400 Hz square-wave pulse |
| Software Platform | Windows 98/Me/XP native BRAIC application suite |
| Data Output | RS-232 interface |
| Dimensions (W×D×H) | 1020 × 490 × 540 mm |
| Weight | 80 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 2400 Series II |
| Analysis Modes | CHN, CHNS, O |
| Typical Analysis Time | 4–8 min per mode |
| Sample Weight Range | 1–2 mg (CHN/CHNS), matrix-dependent for O |
| Detection Principles | Combustion–Reduction–Gas Chromatography–Thermal Conductivity Detection (TCD) |
| Gas Requirements | Helium or Argon carrier gas |
| Compliance | Designed for GLP/GMP environments |
| Software | Elemental Analyzer Data Manager (EADM) v3.x |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | DRC-e |
| Mass Analyzer Type | Quadrupole |
| Resolution (FWHM at m/z 202) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity | Be ≥ 5 Mcps/(mg·L⁻¹), In ≥ 30 Mcps/(mg·L⁻¹), Bi ≥ 20 Mcps/(mg·L⁻¹) |
| Vacuum System | Dual mechanical pumps + dual turbo-molecular pumps (total pumping speed > 380 L/min) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Gas Options | H₂, He, CH₄, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Efficiency | > 10⁷-fold |
| Chemical Resolution | > 150,000 |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | < 0.08% RSD |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | Xevo TQ-S |
| Configuration | Refurbished System with Full Functional Validation |
| Ionization Compatibility | Electrospray (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., APPI, ESCi) |
| Mass Analyzer Architecture | Three Sequential Quadrupole Stages (Q1 → Collision Cell → Q3) |
| Scan Modes | MRM, Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan, Selected Reaction Monitoring (SRM), RADAR™ Simultaneous Quantitation & Screening |
| Software Platform | MassLynx v4.2 or Later with TargetLynx XS, QuanLynx, and UNIFI Integration Capabilities |
| Regulatory Compliance Support | 21 CFR Part 11 Audit Trail, Electronic Signatures, GLP/GMP Data Integrity Framework |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Cary 60 |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤ 0.03% T |
| Automation | Automatic Wavelength Scanning |
| Import Status | Imported Instrument |