Empowering Scientific Discovery

SKC PERMEA-TEC Chemical Permeation Detection Pad

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand SKC
Origin USA
Model PERMEA-TEC
Application Workplace Chemical Permeation Monitoring
Sensitivity 3–5 µg for Aromatic Amines & Isocyanates
Format Adhesive-backed, Skin-contact Compatible Detection Pads
Compliance Designed to Support ASTM F739, ISO 6529, and OSHA 1910.120 Hazard Assessment Protocols
Variant Options Aromatic amines, aromatic isocyanates, aliphatic isocyanates, aliphatic amines, acids/bases, phenols, solvents (with charcoal sorbent for GC analysis), nickel, ortho-phthalaldehyde

Overview

The SKC PERMEA-TEC Chemical Permeation Detection Pad is a validated, skin-safe, adhesive-backed monitoring tool engineered for real-time detection of chemical breakthrough through personal protective equipment (PPE), particularly gloves and sleeves. Unlike conventional permeation testing conducted under static laboratory conditions (e.g., ASTM F739 or ISO 6529), PERMEA-TEC operates under dynamic field conditions—capturing permeation events that occur during actual hand motion, flexion, compression, and abrasion. Its core function relies on selective colorimetric or chemisorptive reactions: specific pad formulations undergo visible, irreversible chromogenic change upon contact with target analytes at trace levels (3–5 µg for aromatic amines and isocyanates). This enables rapid, on-site identification of breakthrough location and timing—critical for validating glove selection, refining hazard communication, and supporting hierarchy-of-controls implementation in industrial hygiene programs.

Key Features

  • Field-deployable, non-invasive detection: Adheres directly to skin beneath gloves without interfering with dexterity or comfort.
  • Chemical-specific variants: Nine distinct formulations optimized for key occupational hazards—including aromatic amines (e.g., aniline, benzidine derivatives), aromatic and aliphatic isocyanates (e.g., TDI, HDI), aliphatic amines, strong acids/bases, phenols, solvents, nickel compounds, and ortho-phthalaldehyde.
  • Ultra-low detection threshold: Confirmed sensitivity down to 3–5 micrograms for high-priority electrophiles such as aromatic amines and isocyanates—well below occupational exposure limits (OELs) and consistent with biological monitoring action levels.
  • Solvent variant includes integrated charcoal sorbent pad: Enables subsequent quantitative analysis via gas chromatography (GC) or GC-MS, supporting forensic exposure assessment and regulatory documentation.
  • Designed for compliance alignment: Supports OSHA 1910.120 hazard evaluation requirements, ASTM F739 method validation, and ISO 6529 permeation kinetics correlation studies.
  • Standardized placement protocol: Optimized positioning on thumb pulp, middle fingertip, and palm center—areas exhibiting highest mechanical stress and documented breakthrough frequency in ergonomic glove studies.

Sample Compatibility & Compliance

PERMEA-TEC pads are compatible with all common glove materials (nitrile, neoprene, butyl, Viton®, polyethylene, and laminated composites) and do not compromise barrier integrity. Each variant is independently verified for specificity—cross-reactivity with structurally unrelated compounds is minimized through proprietary reagent immobilization chemistry. The system complies with industrial hygiene best practices outlined in AIHA RP-3 (Recognition, Evaluation, Control of Occupational Health Hazards) and supports GLP-aligned recordkeeping when used in conjunction with SKC’s standardized observation logs. While not a replacement for quantitative permeation testing, PERMEA-TEC provides essential qualitative and semi-quantitative data required for Tier 1 hazard screening and PPE performance benchmarking per NIOSH Publication 2014-101.

Software & Data Management

PERMEA-TEC is a hardware-only detection platform; no embedded electronics or software are included. However, its output is fully interoperable with standard industrial hygiene documentation workflows. Users record breakthrough time, location, and pad color change intensity using SKC’s optional digital log templates (compatible with PDF/A-2, Excel, and LIMS import formats). For solvent variants, GC/MS chromatograms generated from charcoal desorption are traceable to individual lot numbers (e.g., 20769-3050), enabling full chain-of-custody compliance under 21 CFR Part 11 when paired with validated electronic lab notebooks (ELNs). All product lot certifications and analytical validation reports are available upon request from SKC’s Technical Services Group.

Applications

  • Validation of glove selection in multi-chemical exposure environments (e.g., paint manufacturing, polyurethane foam production, pharmaceutical synthesis).
  • Root-cause analysis of dermal exposure incidents where air sampling or wipe tests yield inconclusive results.
  • Worker training enhancement: Visual demonstration of breakthrough mechanics improves PPE compliance and hazard recognition.
  • Supporting OSHA Process Safety Management (PSM) element 12 (Mechanical Integrity) through periodic PPE performance verification.
  • Supplementing biological monitoring programs by correlating breakthrough events with urinary metabolite trends (e.g., urinary aniline for aromatic amine exposure).
  • Regulatory audit preparation: Provides contemporaneous, defensible evidence of exposure control effectiveness.

FAQ

How frequently should PERMEA-TEC pads be inspected during use?

Inspect pads visually every 60 minutes—or immediately after any glove deformation event (e.g., snagging, puncture, or prolonged compression)—to ensure timely detection of breakthrough onset.
Can PERMEA-TEC pads be reused?

No. Each pad is single-use only. Once color change occurs or after one shift (whichever comes first), the pad must be discarded per local hazardous waste regulations.
Do PERMEA-TEC pads meet FDA or EU REACH requirements?

While not classified as medical devices or consumer products, PERMEA-TEC formulations are REACH SVHC-free and manufactured without intentionally added substances restricted under Annex XIV. Lot-specific SDS and RoHS declarations are provided with each shipment.
Is calibration required prior to use?

No. PERMEA-TEC pads are factory-calibrated and supplied with expiration-dated stability verification. Storage at 15–25°C and protection from UV light preserves reactivity throughout shelf life (typically 24 months from manufacture date).
Can data from PERMEA-TEC be integrated into EHS management systems?

Yes. Structured observation fields (time, location, analyte type, breakthrough grade) map directly to common EHS platforms including Intelex, ETQ Reliance, and Sphera Gensuite via CSV or API-driven ingestion protocols.