| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Aquion |
| Instrument Type | Benchtop Laboratory IC System |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Operating Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Detection Principle | Suppressed Conductivity Detection |
| Pump Technology | Dual-Piston Isocratic/Gradient Capable Pump |
| Eluent Generation | Electrolytic Eluent Generation (EG) compatible |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 Ti (BioRS) |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 100 MPa (15000 psi) |
| Flow Rate Range | Up to 8 mL/min |
| Column Oven Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Detection Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Sample Introduction | Low-Residue Autosampler with Ceramic Needle and Fixed Loop |
| Fluidic Path | Non-stainless-steel (PEEK, Titanium, Sapphire) |
| Software Platform | Chromeleon CDS v6.x / v7.x |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, IQ/OQ/PQ support |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Varioskan ALF Multimode Microplate Reader |
| Price | Upon Request |
| Absorbance Range | 200–1000 nm |
| Absorbance Accuracy | ±1.0% + 0.003 Abs (0–2.0 Abs), ±2.0% (2.0–2.5 Abs) at 450 nm (96-well plate) |
| Photometric Bandwidth | 2.5 nm |
| Excitation Wavelength Range | 200–710 nm |
| Emission Wavelength Range | 210–720 nm |
| Fluorometry & Luminometry Dynamic Range | ≥6 decades |
| Filter Configuration | 3 pre-installed fluorometric filter pairs + 5 open filter positions |
| Detector Type | Photomultiplier Tube (PMT) |
| Light Source | Xenon Flash Lamp |
| Plate Compatibility | 6- to 384-well microplates, μDrop and μDrop Duo plates |
| Onboard Incubation Range | Ambient +2°C to 45°C |
| Shaking Modes | Linear, Orbital, Double Orbital |
| Measurement Modes | Endpoint, Kinetic, Spectral Scan |
| Photometric Read Time (Fast Mode) | ≤10 sec (96-well) |
| Fluorometric/Luminometric Read Time | ≤20 sec (96-well) |
| Sensitivity (Fluorescein) | 0.35 fmol/well (black 384-well plate) |
| (ATP Luminescence) | <275 amol/well (white 96-well plate) |
| (DNA Absorbance) | <1 ng/μL (96-well half-area plate) |
| (Turbidity) | <5 FTU (96-well plate) |
| Linearity | 0–2.5 Abs, ±2.0% at 450 nm (96-well plate) |
| Precision | SD <0.003 Abs or CV <1.0% at 450 nm |
| Dimensions (L × W × H) | 61 × 34 × 40 cm |
| Weight | 24.5 kg |
| Power Supply | 100/115/220/230 V |
| Software | Thermo Scientific SkanIt Software (Research Edition & Drug Discovery Edition), multi-language support (EN, FR, DE, ES, PT, IT, JA, ZH), unlimited installations, no annual license fee |
| Compliance Support | 21 CFR Part 11 (Drug Discovery Edition), GLP/GMP-ready audit trail, electronic signature, user access control |
| Validation Tools | Thermo Scientific Verification Plates (traceable optical performance validation) |
| Warranty | 1-year standard + optional 2-year Rapid Exchange Extended Warranty (Cat. No. A66711) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Thermo Scientific Nicolet iS50 FTIR Spectrometer |
| Instrument Category | Infrared Auxiliary Equipment |
| Instrument Form Factor | Benchtop (not portable — correction per technical specification) |
| Spectral Resolution | 0.09 cm⁻¹ |
| Light Sources | Dual-source configuration (Polaris long-life IR source + tungsten-halogen visible/NIR source) |
| Detectors | Triple-detector sample compartment (MCT, DTGS, and optional far-IR detector) |
| Optical Path | Gold-coated optics (standard), aluminum-coated option available |
| Beam Delivery | Parallel or focused output ports |
| Standard Features | Motorized calibration wheel, motorized neutral density filter wheel, motorized polarizer wheel (optional), purge interface (optional), USB 2.0 high-speed interface, integrated diamond ATR (mid- and far-IR capable), Smart accessory compatibility, automatic beam alignment, internal storage for two additional beamsplitters |
| Software Platform | OMNIC Specta with Mercury GC, TGA-IR, and step-scan modules |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 5030iQ and 5014iQ Next-Generation Ambient Air PM Continuous Monitors |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | Orbitrap Ascend BioPharma Tribrid Mass Spectrometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific 3300 |
| Instrument Type | Online Analyzer |
| Detection Principle | Photometric Method (Colorimetric) |
| Target Metals | Dual-Parameter / Multi-Parameter (e.g., Cd, Cr, Cu, Ni, Pb, Zn, As, Hg) |
| Accuracy/Precision | ±10% of Full Scale |
| Resolution | 0.001 mg/L (ppb-level configurable per analyte) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Ambient Gas MS |
| Type | Fully Automated Ambient Air Quality Monitoring System |
| Compliance | EPA Reference/Equivalent Methods, CNAS-ISO/IEC 17025 Accredited Deployment, Meets China HJ 653–2013 & HJ 654–2013 Standards |
| Data Capture Rate | >90% (7-day rolling average) |
| Measurement Uncertainty | ≤1% deviation between acquired and true reference values |
| Output Interfaces | 0–10 V analog, RS-232/RS-485 bidirectional digital communication |
| Software Platform | ENVIDATA v5.x (Windows-based, 21 CFR Part 11 compliant audit trail option available) |
| Configuration | Central Station + Remote Substations + QA/QC Laboratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | KingFisher Flex |
| Automation Level | Dedicated Fully Automatic |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 2240 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Gas-Sensing Electrode (Ammonia-Selective Electrode) |
| Measurement Range | 0–50.0 mg/L as NH₃–N |
| Accuracy | ±5% of reading or ±0.10 mg/L (whichever is greater) |
| Detection Limit | 0.001 mg/L |
| Analysis Time | <10 minutes per sample |
| Batch Throughput | <10 minutes per measurement |
| Display Interface | Bilingual (English & Chinese) |
| Communication Interfaces | Standard RS-232 and 0–20 mA analog output |
| Self-Diagnostics | Integrated system health monitoring |
| Flow Path | Patented corrosion-resistant fluidic architecture |
| Maintenance Automation | Programmable auto-cleaning and auto-calibration cycles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TriPlus 500 Headspace Autosampler |
| Quotation | Upon Request |
| Sample Capacity | 12–240 vials (field-upgradable) |
| Sampling Technology | Valve-and-loop headspace sampling |
| Operating Modes | Standard, Multiple-Head-Space Extraction (MHE), Multiple-Head-Space Injection (MHI) |
| Software Integration | Thermo Chromeleon CDS, TraceFinder, XCalibur |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Compatible GC Systems | Thermo TRACE 1600 series (direct column coupling or transfer line), third-party GCs via TriPlus 100 LS / RSH / RSH SMART interfaces |
| Sample Path Design | Direct column connection option |
| Shaking Mechanism | Quick Spin Shaking (QSS) |
| Footprint Reduction | ~30% vs. conventional HS-GC systems |
| Brand | Thermo Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 6000 VOC |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Gas Analyzer |
| Typical Configuration | Multi-Component VOC CEMS |
| Measurement Range | 0–5000 ppm (as methane or NMHC) |
| Accuracy | ±1% Full Scale or ±0.1 ppm |
| Response Time | ≤60 s (for NMHC, T90) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCAP PRO ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Spectral Resolution | 7 pm at 200 nm |
| Wavelength Range | 167.021–852.145 nm |
| RF Generator | 27.12 MHz, 750–1600 W adjustable |
| Plasma Gas Flow | 0.0–20.0 L/min (MFC-controlled) |
| Nebulizer Gas Flow | 0.0–1.5 L/min (MFC-controlled) |
| Auxiliary Gas Flow | 0.0–2.0 L/min (MFC-controlled) |
| Radial Viewing Height | 6–18 mm |
| Torch Orientation | Vertical |
| Detector | Charge Injection Device (CID) Array |
| Purge Gas | Optional integrated MFC (0–0.25 L/min) |
| Sample Introduction | 4-channel peristaltic pump (0–125 rpm) |
| Warm-up Time | ≤5 min from standby |
| UV Enhancement Mode | Dual UV exposure for improved sensitivity below 240 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | iCAP MSX |
| Configuration | Single-Quadrupole ICP-MS |
| Energy Efficiency | Enhanced power management & reduced standby consumption |
| Packaging | FSC-certified materials, minimal plastic, recyclable transport crates |
| Unit Size | Each |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Sorvall™ ST 8 Benchtop Centrifuge |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 17i |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Chemiluminescence (NO–O₃ Reaction) |
| Measurement Modes | NO, NOₓ, Nₜ |
| NH₃ Quantification Method | Stainless-Steel Catalytic Converter-Based Conversion to NO |
| Output Signals | Analog (0–10 V / 4–20 mA), Digital (Ethernet) |
| Data Storage | Internal Flash Memory |
| Remote Access | Yes, via Local Area Network |
| Compliance | Designed for EPA Reference Method Compliant Monitoring (e.g., EQOA-0038), Supports GLP/GMP Audit Trail Requirements (via optional software logging) |
| Operating Environment | Indoor/Outdoor Enclosure Rated NEMA 4X |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 48.3 cm W × 17.8 cm H × 55.9 cm D (19″ Rack Mountable) |
| Weight | 22.7 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SystemSIX |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL™ iSpark Plus Series |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | VeritiPro |
| Instrument Type | Standard Thermal Cycler |
| Pricing | Available Upon Request |
| Connectivity | Wi-Fi & Ethernet-enabled |
| Cloud Integration | Thermo Fisher Cloud Platform |
| Temperature Control | VeriFlex™ 6-zone independent thermal control module |
| Ramp Rate | Up to 5.0 °C/sec (typical, depending on block configuration) |
| Block Format | 96-well standard or 0.2 mL tube compatible |
| Operating Noise Level | <45 dB(A) at 1 m |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Oscillation Mode | Continuous Horizontal Acceleration/Deceleration |
| Frequency Range | 0–2 Hz |
| Programmable Timing | Yes |
| Application-Specific Design | Optimized for Nunc Cell Factory stacking systems (1–10 layers) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestically Produced Equipment |
| Model | Forma Steri-Cycle CO₂ Incubator (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Airflow Cycle Duration | ~14 hr |
| Sterilization Temperature | 140°C |
| Temperature Alarm Threshold | ≥60°C |
| HEPA Filtration Class | ISO Class 5 (Class 100) |
| Control System | Microprocessor-Based with Alphanumeric Display |
| CO₂ Sensor Options | Infrared (IR) or Thermal Conductivity (TC) |
| Humidity Monitoring | Optional |
| Door Configuration | Reversible Swing |
| Compliance Support | IQ/OQ Documentation Kits Available |
| Data Logging | Optional Integrated Datalogger |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 111 |
| Zero Air Purity | SO₂ ≤ 0.5 ppb, NO ≤ 0.5 ppb, NO₂ ≤ 0.5 ppb, O₃ ≤ 0.5 ppb, CO ≤ 0.1 ppm, HC ≤ 0.1 ppm |
| Flow Rate | 5, 10 (standard), or 20 SLPM |
| Output Pressure | 10–30 PSI |
| Dew Point | 0 °C |
| Flow Measurement Accuracy | ±1% of reading (0–10 SLPM range) |
| Configuration | Integrated generator unit with external air compressor |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EXTREVA ASE |
| Instrument Type | Vacuum Parallel Concentrator |
| Automation Level | Fully Integrated ASE + Evaporation Workflow |