Empowering Scientific Discovery

Thermo Fisher Scientific (China) Co., Ltd. Group Booth

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelAquion
Instrument TypeBenchtop Laboratory IC System
Maximum Pump Pressure5000 psi
Flow Rate Range0.00–5.00 mL/min
Operating Temperature Range30–60 °C
Temperature Reproducibility±0.5 °C
Eluent Concentration Range0.1–100 mM (dependent on eluent chemistry)
Detection PrincipleSuppressed Conductivity Detection
Pump TechnologyDual-Piston Isocratic/Gradient Capable Pump
Eluent GenerationElectrolytic Eluent Generation (EG) compatible
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelUltiMate 3000 Ti (BioRS)
Instrument TypeUltra-High Performance Liquid Chromatograph (UHPLC)
Maximum Pressure100 MPa (15000 psi)
Flow Rate RangeUp to 8 mL/min
Column Oven Temperature Range5–110 °C
Gradient Delay VolumeAdjustable via SpinFlow™ Technology
Detection CompatibilityUV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS
Sample IntroductionLow-Residue Autosampler with Ceramic Needle and Fixed Loop
Fluidic PathNon-stainless-steel (PEEK, Titanium, Sapphire)
Software PlatformChromeleon CDS v6.x / v7.x
ComplianceFDA 21 CFR Part 11, GLP/GMP-ready audit trail, IQ/OQ/PQ support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (China-manufactured)
ModelVarioskan ALF Multimode Microplate Reader
PriceUpon Request
Absorbance Range200–1000 nm
Absorbance Accuracy±1.0% + 0.003 Abs (0–2.0 Abs), ±2.0% (2.0–2.5 Abs) at 450 nm (96-well plate)
Photometric Bandwidth2.5 nm
Excitation Wavelength Range200–710 nm
Emission Wavelength Range210–720 nm
Fluorometry & Luminometry Dynamic Range≥6 decades
Filter Configuration3 pre-installed fluorometric filter pairs + 5 open filter positions
Detector TypePhotomultiplier Tube (PMT)
Light SourceXenon Flash Lamp
Plate Compatibility6- to 384-well microplates, μDrop and μDrop Duo plates
Onboard Incubation RangeAmbient +2°C to 45°C
Shaking ModesLinear, Orbital, Double Orbital
Measurement ModesEndpoint, Kinetic, Spectral Scan
Photometric Read Time (Fast Mode)≤10 sec (96-well)
Fluorometric/Luminometric Read Time≤20 sec (96-well)
Sensitivity (Fluorescein)0.35 fmol/well (black 384-well plate)
(ATP Luminescence)<275 amol/well (white 96-well plate)
(DNA Absorbance)<1 ng/μL (96-well half-area plate)
(Turbidity)<5 FTU (96-well plate)
Linearity0–2.5 Abs, ±2.0% at 450 nm (96-well plate)
PrecisionSD <0.003 Abs or CV <1.0% at 450 nm
Dimensions (L × W × H)61 × 34 × 40 cm
Weight24.5 kg
Power Supply100/115/220/230 V
SoftwareThermo Scientific SkanIt Software (Research Edition & Drug Discovery Edition), multi-language support (EN, FR, DE, ES, PT, IT, JA, ZH), unlimited installations, no annual license fee
Compliance Support21 CFR Part 11 (Drug Discovery Edition), GLP/GMP-ready audit trail, electronic signature, user access control
Validation ToolsThermo Scientific Verification Plates (traceable optical performance validation)
Warranty1-year standard + optional 2-year Rapid Exchange Extended Warranty (Cat. No. A66711)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-manufactured)
ModelThermo Scientific Nicolet iS50 FTIR Spectrometer
Instrument CategoryInfrared Auxiliary Equipment
Instrument Form FactorBenchtop (not portable — correction per technical specification)
Spectral Resolution0.09 cm⁻¹
Light SourcesDual-source configuration (Polaris long-life IR source + tungsten-halogen visible/NIR source)
DetectorsTriple-detector sample compartment (MCT, DTGS, and optional far-IR detector)
Optical PathGold-coated optics (standard), aluminum-coated option available
Beam DeliveryParallel or focused output ports
Standard FeaturesMotorized calibration wheel, motorized neutral density filter wheel, motorized polarizer wheel (optional), purge interface (optional), USB 2.0 high-speed interface, integrated diamond ATR (mid- and far-IR capable), Smart accessory compatibility, automatic beam alignment, internal storage for two additional beamsplitters
Software PlatformOMNIC Specta with Mercury GC, TGA-IR, and step-scan modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
Model5030iQ and 5014iQ Next-Generation Ambient Air PM Continuous Monitors
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China-manufactured)
ModelOrbitrap Ascend BioPharma Tribrid Mass Spectrometer
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelThermo Scientific 3300
Instrument TypeOnline Analyzer
Detection PrinciplePhotometric Method (Colorimetric)
Target MetalsDual-Parameter / Multi-Parameter (e.g., Cd, Cr, Cu, Ni, Pb, Zn, As, Hg)
Accuracy/Precision±10% of Full Scale
Resolution0.001 mg/L (ppb-level configurable per analyte)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelAmbient Gas MS
TypeFully Automated Ambient Air Quality Monitoring System
ComplianceEPA Reference/Equivalent Methods, CNAS-ISO/IEC 17025 Accredited Deployment, Meets China HJ 653–2013 & HJ 654–2013 Standards
Data Capture Rate>90% (7-day rolling average)
Measurement Uncertainty≤1% deviation between acquired and true reference values
Output Interfaces0–10 V analog, RS-232/RS-485 bidirectional digital communication
Software PlatformENVIDATA v5.x (Windows-based, 21 CFR Part 11 compliant audit trail option available)
ConfigurationCentral Station + Remote Substations + QA/QC Laboratory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelKingFisher Flex
Automation LevelDedicated Fully Automatic
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
Model2240
Instrument TypeOnline Analyzer
Measurement PrincipleGas-Sensing Electrode (Ammonia-Selective Electrode)
Measurement Range0–50.0 mg/L as NH₃–N
Accuracy±5% of reading or ±0.10 mg/L (whichever is greater)
Detection Limit0.001 mg/L
Analysis Time<10 minutes per sample
Batch Throughput<10 minutes per measurement
Display InterfaceBilingual (English & Chinese)
Communication InterfacesStandard RS-232 and 0–20 mA analog output
Self-DiagnosticsIntegrated system health monitoring
Flow PathPatented corrosion-resistant fluidic architecture
Maintenance AutomationProgrammable auto-cleaning and auto-calibration cycles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelTriPlus 500 Headspace Autosampler
QuotationUpon Request
Sample Capacity12–240 vials (field-upgradable)
Sampling TechnologyValve-and-loop headspace sampling
Operating ModesStandard, Multiple-Head-Space Extraction (MHE), Multiple-Head-Space Injection (MHI)
Software IntegrationThermo Chromeleon CDS, TraceFinder, XCalibur
ComplianceFDA 21 CFR Part 11, GLP/GMP-ready
Compatible GC SystemsThermo TRACE 1600 series (direct column coupling or transfer line), third-party GCs via TriPlus 100 LS / RSH / RSH SMART interfaces
Sample Path DesignDirect column connection option
Shaking MechanismQuick Spin Shaking (QSS)
Footprint Reduction~30% vs. conventional HS-GC systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
Model6000 VOC
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Gas Analyzer
Typical ConfigurationMulti-Component VOC CEMS
Measurement Range0–5000 ppm (as methane or NMHC)
Accuracy±1% Full Scale or ±0.1 ppm
Response Time≤60 s (for NMHC, T90)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModeliCAP PRO ICP-OES
Instrument TypeFull-Spectrum Simultaneous ICP-OES
Spectral Resolution7 pm at 200 nm
Wavelength Range167.021–852.145 nm
RF Generator27.12 MHz, 750–1600 W adjustable
Plasma Gas Flow0.0–20.0 L/min (MFC-controlled)
Nebulizer Gas Flow0.0–1.5 L/min (MFC-controlled)
Auxiliary Gas Flow0.0–2.0 L/min (MFC-controlled)
Radial Viewing Height6–18 mm
Torch OrientationVertical
DetectorCharge Injection Device (CID) Array
Purge GasOptional integrated MFC (0–0.25 L/min)
Sample Introduction4-channel peristaltic pump (0–125 rpm)
Warm-up Time≤5 min from standby
UV Enhancement ModeDual UV exposure for improved sensitivity below 240 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China-manufactured)
ModeliCAP MSX
ConfigurationSingle-Quadrupole ICP-MS
Energy EfficiencyEnhanced power management & reduced standby consumption
PackagingFSC-certified materials, minimal plastic, recyclable transport crates
Unit SizeEach
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSorvall™ ST 8 Benchtop Centrifuge
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Model17i
Instrument TypeOnline Gas Analyzer
Detection PrincipleChemiluminescence (NO–O₃ Reaction)
Measurement ModesNO, NOₓ, Nₜ
NH₃ Quantification MethodStainless-Steel Catalytic Converter-Based Conversion to NO
Output SignalsAnalog (0–10 V / 4–20 mA), Digital (Ethernet)
Data StorageInternal Flash Memory
Remote AccessYes, via Local Area Network
ComplianceDesigned for EPA Reference Method Compliant Monitoring (e.g., EQOA-0038), Supports GLP/GMP Audit Trail Requirements (via optional software logging)
Operating EnvironmentIndoor/Outdoor Enclosure Rated NEMA 4X
Power Supply100–240 VAC, 50/60 Hz
Dimensions48.3 cm W × 17.8 cm H × 55.9 cm D (19″ Rack Mountable)
Weight22.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSystemSIX
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China-manufactured)
ModelARL™ iSpark Plus Series
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China-manufactured)
ModelVeritiPro
Instrument TypeStandard Thermal Cycler
PricingAvailable Upon Request
ConnectivityWi-Fi & Ethernet-enabled
Cloud IntegrationThermo Fisher Cloud Platform
Temperature ControlVeriFlex™ 6-zone independent thermal control module
Ramp RateUp to 5.0 °C/sec (typical, depending on block configuration)
Block Format96-well standard or 0.2 mL tube compatible
Operating Noise Level<45 dB(A) at 1 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Instrument TypeAir-Jacketed Temperature-Controlled Orbital Shaker
Oscillation ModeContinuous Horizontal Acceleration/Deceleration
Frequency Range0–2 Hz
Programmable TimingYes
Application-Specific DesignOptimized for Nunc Cell Factory stacking systems (1–10 layers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestically Produced Equipment
ModelForma Steri-Cycle CO₂ Incubator (Domestically Manufactured)
PricingAvailable Upon Request
Airflow Cycle Duration~14 hr
Sterilization Temperature140°C
Temperature Alarm Threshold≥60°C
HEPA Filtration ClassISO Class 5 (Class 100)
Control SystemMicroprocessor-Based with Alphanumeric Display
CO₂ Sensor OptionsInfrared (IR) or Thermal Conductivity (TC)
Humidity MonitoringOptional
Door ConfigurationReversible Swing
Compliance SupportIQ/OQ Documentation Kits Available
Data LoggingOptional Integrated Datalogger
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelThermo Scientific 111
Zero Air PuritySO₂ ≤ 0.5 ppb, NO ≤ 0.5 ppb, NO₂ ≤ 0.5 ppb, O₃ ≤ 0.5 ppb, CO ≤ 0.1 ppm, HC ≤ 0.1 ppm
Flow Rate5, 10 (standard), or 20 SLPM
Output Pressure10–30 PSI
Dew Point0 °C
Flow Measurement Accuracy±1% of reading (0–10 SLPM range)
ConfigurationIntegrated generator unit with external air compressor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelEXTREVA ASE
Instrument TypeVacuum Parallel Concentrator
Automation LevelFully Integrated ASE + Evaporation Workflow
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0