ST-801 Pump-Aspiration Formaldehyde Analyzer
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | ST-801 |
| Price Range | USD 1,400 – 2,800 (FOB) |
| Detection Principle | Electrochemical Sensor |
| Measurement Ranges | 0–5 ppm (ST-801A), 0–10 ppm (ST-801C), 0–20 ppm (ST-801D), 0–50 ppm (ST-801E), 0–100 ppm (ST-801H), 0–1000 ppm (ST-801M) |
| Resolution | 0.01 ppm (≤100 ppm models), 0.1 ppm (ST-801M) |
| Accuracy | ≤±3% FS |
| Response Time | ≤30 s (T90) |
| Recovery Time | ≤40 s |
| Operating Temperature | −20 °C to +70 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sensor Lifetime | ≥2 years (up to 10 years under optimal conditions) |
| Power Supply | 3.6 V DC, 1800 mAh rechargeable Li-ion battery with charging protection |
| Dimensions | 125 × 52 × 30 mm (L×W×H) |
| Weight | 200 g |
| Enclosure Rating | Intrinsically Safe (IS) certified for Class I, Division 1, Groups A–D environments |
| Display | Backlit LCD with real-time concentration, units, battery status, and alarm indicators |
| Alarm Modes | Audible (buzzer), visual (LED), haptic (vibration), and low-battery alert |
| Calibration | Built-in zero and span calibration functions with temperature compensation |
| Data Recovery | Non-volatile memory retains configuration and recent readings after power loss |
| Sampling Method | Integrated diaphragm micro-pump (pump-aspiration) |
| Optional Accessory | 0.8 m extendable sampling probe |
Overview
The ST-801 Pump-Aspiration Formaldehyde Analyzer is a portable, intrinsically safe gas detection instrument engineered for reliable, real-time quantification of formaldehyde (HCHO) in ambient air across occupational health, environmental monitoring, and industrial hygiene applications. Unlike colorimetric or photometric methods, the ST-801 employs a high-selectivity electrochemical sensor—specifically optimized for formaldehyde’s redox behavior at controlled electrode potentials—to deliver stable, linear output proportional to gas concentration. Its integrated micro-diaphragm pump ensures consistent, pressure-stabilized sample draw through a diffusion barrier, minimizing flow-dependent drift and enabling accurate measurements even in low-velocity or stagnant air environments. Designed for compliance with international exposure assessment protocols—including OSHA PEL (0.75 ppm TWA), ACGIH TLV (0.3 ppm TWA), and WHO indoor air guidelines—the ST-801 supports both spot-check verification and time-weighted average (TWA) logging when paired with optional data-logging firmware.
Key Features
- Intrinsically safe construction certified for hazardous locations (Class I, Div 1, Groups A–D), enabling deployment in petrochemical facilities, laboratories, and confined spaces.
- Multi-range configuration: Six factory-calibrated variants (ST-801A to ST-801M) cover 0–5 ppm to 0–1000 ppm, with resolution down to 0.01 ppm for trace-level IAQ assessments.
- Integrated temperature compensation algorithm corrects for thermal drift across −20 °C to +70 °C operating range, ensuring metrological consistency without manual recalibration.
- Dual-point (zero/span) calibration capability via onboard menu interface; supports user-initiated field calibration using certified HCHO standard gases.
- Backlit LCD display with dual-unit support (ppm and mg/m³), real-time battery status, and dynamic alarm iconography for immediate hazard recognition.
- Non-volatile memory preserves last 100 measurement records and system configuration settings—even during battery replacement or unexpected shutdown.
- Compact ergonomic housing (125 × 52 × 30 mm) fabricated from abrasion-resistant polymer with IP65-rated ingress protection against dust and water splashes.
Sample Compatibility & Compliance
The ST-801 is validated for use in non-corrosive, non-condensing atmospheres with relative humidity ≤95% RH. It exhibits minimal cross-sensitivity to common interferents including CO, NO₂, SO₂, and ethanol (<2% signal deviation at 50 ppm), as verified per ISO 16000-23 Annex B test methodology. The device meets EN 50104:2018 requirements for electrochemical gas detectors and conforms to IEC 60079-0 and IEC 60079-11 for intrinsic safety. While not FDA-cleared as a medical device, its measurement uncertainty profile aligns with ISO/IEC 17025-accredited laboratory validation criteria for workplace air sampling. For GLP/GMP-aligned deployments, optional audit-trail firmware enables timestamped calibration logs and alarm event histories compliant with 21 CFR Part 11 electronic record requirements.
Software & Data Management
The ST-801 operates autonomously without PC dependency; however, optional USB-C interface (via accessory cable) enables firmware updates and bidirectional data exchange using proprietary Windows-compatible desktop software. This application supports export of CSV-formatted time-series datasets—including concentration, timestamp, temperature, battery voltage, and alarm flags—for integration into LIMS or EHS reporting platforms. Calibration certificates generated by the software include NIST-traceable reference gas lot numbers, operator ID, and environmental metadata. Firmware v2.3+ introduces configurable alarm hysteresis and auto-zero suppression logic to reduce false positives during transient humidity shifts.
Applications
- Indoor Air Quality (IAQ) audits in residential, commercial, and educational buildings—particularly post-renovation or furniture installation where formaldehyde off-gassing is suspected.
- Ongoing exposure monitoring for workers in plywood manufacturing, resin production, textile finishing, and funeral home operations.
- Regulatory compliance verification for national programs aligned with China’s GB/T 18883-2022, EU’s REACH Annex XVII restrictions, and California Air Resources Board (CARB) ATCM Phase II emission standards.
- Field validation of HVAC filtration efficiency and activated carbon adsorption unit performance.
- Emergency response screening during chemical spills or fire investigations where formaldehyde may be generated as a thermal decomposition product of urea-formaldehyde foam or melamine resins.
FAQ
What formaldehyde detection principle does the ST-801 employ?
It utilizes a three-electrode electrochemical sensor with acid electrolyte and catalytic working electrode optimized for HCHO oxidation at +0.45 V vs. Ag/AgCl reference.
Can the ST-801 measure formaldehyde in high-humidity environments?
Yes—up to 95% RH non-condensing. For sustained operation above 85% RH, we recommend optional hydrophobic membrane filters to prevent electrolyte dilution.
Is sensor replacement user-serviceable?
Yes. The electrochemical cell is a field-replaceable module (part number F-SNSR-ST801); no soldering or firmware reconfiguration is required.
Does the device support datalogging?
Standard units store up to 100 readings. Extended logging (10,000+ points) requires optional firmware upgrade and USB-C data cable.
What certifications does the ST-801 hold for international shipment?
CE marking (EMC Directive 2014/30/EU, RoHS 2011/65/EU), ATEX Category II 2G Ex ia IIC T4 Ga, and UKCA certification are available upon request with model-specific documentation.

