SurgiVet V6004 Small Animal Multiparameter Patient Monitor

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Harvard Apparatus
Origin USA
Manufacturer Type Authorized Distributor
Import Status Imported
Model V6004
Pricing Available Upon Request

Overview

The SurgiVet V6004 Small Animal Multiparameter Patient Monitor is a clinical-grade, non-invasive physiological monitoring system engineered for real-time, high-fidelity assessment of hemodynamic and respiratory parameters in laboratory rodents, rabbits, ferrets, and other small mammals weighing 20 g to 5 kg. Designed around oscillometric and photoplethysmographic principles, the V6004 delivers continuous, artifact-resistant measurements of systolic, diastolic, and mean arterial pressure (SAP, DAP, MAP), central venous pressure (CVP), peripheral capillary oxygen saturation (SpO₂), and pulse rate. Its architecture integrates calibrated pressure transducer inputs, dual-wavelength red/infrared LED photodetectors, and adaptive signal filtering algorithms optimized for low-perfusion, high-heart-rate physiological conditions typical of murine and lagomorph models. The device complies with IEC 60601-1 (3rd ed.) safety standards for medical electrical equipment and meets essential performance criteria outlined in ISO 80601-2-56 for patient monitors used in research settings.

Key Features

  • Non-invasive oscillometric blood pressure measurement with automated cuff inflation/deflation cycles and dynamic pressure range adaptation (0–300 mmHg)
  • Dual-wavelength (660 nm / 940 nm) SpO₂ sensing with motion-tolerant algorithm and perfusion index (PI) output
  • Real-time pulse waveform display with beat-to-beat interval analysis and arrhythmia flagging
  • Configurable CVP monitoring via external pressure transducer input (0–100 mmHg range, ±1 mmHg accuracy)
  • Modular design supporting optional add-ons including temperature probe interface (thermistor-based, -20°C to +50°C) and ECG lead set (bipolar limb leads)
  • Backlit graphical LCD with adjustable contrast, capable of simultaneous 4-parameter numeric display and trend waveform overlay
  • Internal rechargeable battery providing ≥4 hours of continuous operation; AC adapter included

Sample Compatibility & Compliance

The V6004 is validated for use across common preclinical species including C57BL/6 and BALB/c mice, Sprague-Dawley and Wistar rats, New Zealand White rabbits, and guinea pigs. Cuff sizes (XS, S, M) are selected based on limb or tail circumference per AALAC-recommended guidelines. All pressure sensors are traceably calibrated against NIST-traceable deadweight testers annually. The system supports GLP-compliant data acquisition when paired with optional timestamped analog output (0–5 V DC) and adheres to FDA 21 CFR Part 11 requirements for electronic records when used with validated third-party data logging software. It is not intended for human use and carries appropriate labeling per 21 CFR §801.109.

Software & Data Management

While the V6004 operates as a standalone monitor, its analog outputs (pressure, SpO₂, pulse) enable integration into existing data acquisition platforms such as LabChart (ADInstruments), PowerLab systems, or custom MATLAB/Python-based acquisition scripts. Optional RS-232 serial interface allows ASCII-formatted parameter streaming at 1 Hz resolution for long-term protocol logging. All displayed values include built-in statistical reporting (min/max/mean over user-defined intervals) and automatic alarm thresholds (configurable high/low limits with visual and audible alerts). Audit trails for parameter changes and alarm events are retained in volatile memory for up to 72 hours.

Applications

  • Cardiovascular pharmacology studies assessing acute hemodynamic responses to vasoactive agents
  • Anesthesia monitoring during surgical procedures under isoflurane, ketamine/xylazine, or pentobarbital regimens
  • Respiratory challenge models (e.g., hypoxia, LPS-induced inflammation) requiring concurrent SpO₂ and BP tracking
  • Toxicology endpoints involving circulatory stability assessment post-dose administration
  • Longitudinal recovery monitoring following implantation of telemetry devices or vascular catheters
  • Training platform for veterinary and biomedical graduate students in rodent physiology techniques

FAQ

Is the V6004 compatible with telemetry systems?

Yes — its analog outputs can be synchronized with implanted telemetry receivers (e.g., Data Sciences International DSI TA-F10 or HD-S10) for hybrid wired/wireless monitoring configurations.
Does it support pediatric or neonatal rodent monitoring?

The XS cuff and high-sensitivity SpO₂ algorithm are validated down to 20 g body weight; however, MAP accuracy below 15 g is not clinically established.
Can pressure calibration be performed in-house?

No — recalibration requires factory service using NIST-traceable reference standards; field verification is supported via zero-balance and pressure step-check routines.
What is the warranty coverage?

Harvard Apparatus provides a 2-year limited warranty covering parts and labor for defects in materials and workmanship under normal laboratory use.
Is FDA clearance required for use in academic research?

No — the V6004 is classified as a research-use-only (RUO) device outside the scope of FDA 510(k) clearance when deployed exclusively in non-clinical animal studies.