Harvard Apparatus
Filter
Showing 1–30 of 137 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | 597316 |
| Category | Research-Grade Physiological Salt Solution for Ex Vivo Neural Tissue Preparation |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BIO-DWB |
| Price Range | USD 1,400 – 7,000 |
| Sensor Accuracy (Mouse) | ±1 g |
| Sensor Resolution (Mouse) | 0.2 g |
| Sensor Range (Mouse) | 15–50 g |
| Sensor Range (Rat) | 150–500 g |
| Sensor Resolution (Rat) | 0.8 g |
| Chamber Dimensions (Mouse) | 11.5 × 11.5 × 22 cm (L×W×H) |
| Chamber Dimensions (Rat) | 22 × 22 × 30 cm (L×W×H) |
| External Dimensions (Mouse) | 17 × 17 × 22 cm |
| External Dimensions (Rat) | 30 × 30 × 35 cm |
| Weight (Mouse Unit) | 1 kg |
| Weight (Rat Unit) | 2.5 kg |
| Floor Material | Gray Polypropylene Copolymer (PPC) |
| Wall Material | Transparent PPC |
| Interface | USB 2.0 |
| OS Compatibility | Windows 7 or later |
| Minimum CPU | Intel Core i3 or i5 |
| Minimum RAM | 3 GB |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-FMA |
| Price Range | USD 1,400 – 7,000 |
| Data Acquisition Rate | 10 ms |
| Sensor Count | 154 (dual infrared arrays, 77 per side) |
| Dimensions (L×W×H) | 124 × 28 × 20 cm |
| Runway Width | 80 mm (rat), 50 mm (mouse), interchangeable |
| Bar Spacing | Adjustable from 25 px to 75 px (≈0.6–1.9 mm, software-calibrated pixel-to-mm mapping) |
| Bar Height | Adjustable |
| Start Box Illumination | Cold-white LED flash, software-controllable intensity and timing |
| Interface | USB 2.0 |
| Power Supply | Standard AC adapter (100–240 V, 50/60 Hz) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-FSTR/M |
| Price Range | USD 1,400 – 7,000 |
| Capacity | 4 simultaneous mice |
| Cylinder Dimensions | 11.7 cm (diameter) × 15.9 cm (height) |
| Detection Method | Dual-modal (video + piezoelectric vibration sensing) |
| Behavioral Classification Accuracy | ≥96% |
| Output Data Format | Timestamped behavioral state sequence (Immobility/Swimming/Climbing), raw video + vibration waveform export |
| Software Features | Playback, re-analysis, GLP-compliant audit trail, CSV/Excel export |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | BIO-GRADIENT |
| Channel Configuration | 1-channel (2 mice or 1 rat) / 2-channel (4 mice or 2 rats) |
| Overall Dimensions (L×W×H) | 139 × 30 × 40 cm (1-channel) |
| Weight | 25 kg (1-channel) |
| Runway Dimensions | 125 × 10 × 15 cm (per runway) |
| Temperature Range | 5–55 °C (floor surface) |
| Temperature Stability | ±1 °C |
| Floor Material | Anodized aluminum heating plate |
| Wall & Lid Material | Gray PPC-coated polycarbonate walls, transparent PPC lid |
| Detection Resolution | Up to 20 discrete temperature zones per animal |
| Output Metrics | Position-resolved dwell time per zone, cumulative path length, zone transition frequency, thermal preference index (TPI), latency to first entry into target zones |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BIO-KWB |
| Price Range | USD 1,400 – 7,000 |
| Footprint (Rat System) | 130 × 50 × 45 cm |
| Footprint (Mouse System) | 80 × 40 × 30 cm |
| Camera Resolution | 640 × 480 |
| Camera Frame Rate | 30 Hz |
| Force Sensor Sampling Rate | 100 Hz |
| Software | KWB Full-Function License (Unlimited Replay Mode, Unlimited PC Installations) |
| OS Compatibility | Windows 7 or later |
| Minimum CPU | Intel Core i5 or equivalent |
| Minimum RAM | 4 GB |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BIO-T2CT |
| Temperature Range | –3 °C to 65 °C (ambient 20–25 °C) |
| Temperature Accuracy | ±0.5 °C |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 32 cm × 57 cm × 45.5 cm |
| Cage Dimensions | 330 mm × 165 mm × 300 mm |
| Cage Material | Optical-grade acrylic |
| Monitoring Metrics | Dwell time per zone, entry latency, real-time position, zone-specific temperature, timestamp |
| Software Option | Optional automated video-tracking and thermal-zone logging module |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECM399 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM630 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | ECM830 |
| High-Voltage Mode | 50–3000 V (5 V step), 56 Ω, 111 µF, pulse width 10–600 µs (1 µs resolution) |
| Low-Voltage Mode | 5–500 V (1 V step), 56 Ω, 4000 µF, pulse width 10–999 µs / 1–999 ms / 1–10 s (1 µs / 1 ms / 0.1 s resolution) |
| Pulse Number | 1–99 |
| Inter-Pulse Interval | 100 ms–10 s |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Models | BTX 610, BTX 620, BTX 640 |
| Sterility | Gamma-Irradiated, Individually Packed |
| Electrode Material | Embedded Aluminum |
| Electrode Gap Options | 1.0 mm, 2.0 mm, 4.0 mm |
| Maximum Electric Field Strength | 25 kV/cm |
| Cap Design | Leak-Resistant Snap-On Cap |
| Volume Range per Cuvette | 20–800 µL |
| Packaging | 50 sterile units per box |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MOS High-Throughput Multiwell Electroporation System |
| Quotation | Available Upon Request |
| Pulse Generator Compatibility | ECM630 & ECM830 |
| MOS Plate Formats | 25-well & 96-well |
| MOS Plate Processor Models | HT-100 (manual column-by-column pulsing) & HT-200 (automated sequential column pulsing) |
| Voltage Range | 0–3000 V DC |
| Pulse Duration | 10 µs – 10 s |
| Number of Pulses | 1–99 |
| Electrode Architecture | Patented composite electrode array with cross-contamination mitigation design |
| Included Accessories | Sterile plate lid for contamination control |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrimune Large-Scale Fusion System |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BTX MAX Transfection System |
| Pricing | Available Upon Request |
| Electroporation Chamber Gap | 4 mm |
| Sample Volume Range | 2–6 mL |
| Voltage Range | 50–1200 V |
| Pulse Duration | 0.05–10 ms |
| Inter-Pulse Interval | 0.2–1000 ms (1 Hz–5 kHz) |
| Data Interface | USB Flash Drive Support |
| Control Interface | Capacitive Touchscreen |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | ClockLab |
| Interface | USB 2.0 + RJ-45 high-throughput data acquisition |
| Max Input Channels | 448 (8 interface boxes × 56 channels each) |
| Output Channels | 64 light-control channels (8 boxes × 8 outputs) |
| Supported Species | Mus musculus, Rattus norvegicus, Mesocricetus auratus, Drosophila melanogaster, Apis mellifera, Chlamydomonas reinhardtii, Lynx lynx, Sciurus carolinensis, Thomomys bottae, Chelonia mydas, Limulus polyphemus, Homo sapiens |
| Data File Compatibility | Minimitter, Actiwatch, Dataquest, Stanford Sleep Lab formats |
| OS Support | Windows 2000/XP/Vista/7/10, macOS 9.x and macOS X (Intel & Apple Silicon via Rosetta 2) |
| Power Failure Recovery | Full session state retention and auto-resume |
| Data Export | CSV, MATLAB (.mat), XML, PNG, TIFF, PDF |
| Compliance | GLP-aligned metadata logging, FDA 21 CFR Part 11–ready audit trail (optional configuration) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mask Series (Canine, Feline, Rodent/Avian) |
| Pricing | Available Upon Request |
| Diaphragm Opening Diameter | 25 mm / 38 mm / 44 mm / 50 mm (varies by size) |
| Port ID | 11.9 mm / 15 mm |
| Material | Polycarbonate (mask body), Medical-Grade Rubber (diaphragm) |
| Sizes | Small, Medium, Large, Multi-Pack Kits |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-0001 |
| Gas Agent | Isoflurane |
| Carrier Gas | Oxygen |
| O₂ Inlet Pressure | 50 PSI (fixed) |
| O₂ Flow Range | 0–4 LPM (mechanically limited) |
| Max Safety Flow | 50 LPM (safety-limited bypass) |
| Vaporizer Range | 0.5–5.0% Isoflurane |
| CO₂ Absorber Capacity | 3 lb (reusable, removable) |
| Application Weight Limit | ≤136 kg (300 lb) |
| Compatibility | Rebreathing & Non-rebreathing Circuits |
| Integrable With | Veterinary Ventilators |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX 384L |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BTX Electrofusion Electrodes |
| Voltage Range | 0–500 V DC (Microslides), 0–480 V DC / 0–16 V AC (Meander & Flat Chambers) |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gaps | 0.2 mm (Meander), 0.5 / 1.0 / 3.2 / 10.0 mm (Microslides), 1.0 mm (Flat Chamber) |
| Field Uniformity | Non-uniform (Microslides, Meander, Flat in fusion mode), Uniform (Flat in electroporation mode) |
| Sample Volume Capacity | 20–2200 µL (Microslides), 5–20 µL (Meander), 500 µL (Flat Chamber) |
| Compatible Systems | ECM830, ECM2001 |
| Reusability | Yes (with mild cleaning) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model Variants | 450, 450-1, 453, 453-10 |
| Voltage Range | 0–500 VDC |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gap Options | 0.5 mm, 1.0 mm, 3.2 mm, 10 mm |
| Sample Volume Capacity | 20 µL – 2.2 mL |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 20–80% |
| Altitude Limit | ≤2000 m |
| Insulation Category | CAT I |
| Pollution Degree | II |
| Autoclavable | No |
| Compatible Generators | ECM® 2001, ECM 630, 830, 395, 399, 600, T820 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX Model 524 |
| Pricing | Upon Request |
| Electrode Type | Reusable bipolar tweezer-style electroporation electrode |
| Length | 11.5 cm |
| Adjustable Inter-electrode Gap | Up to 20 mm |
| Electrode Disk Diameter Options | 7 mm (Part #45-0118) or 10 mm (Part #45-0119) |
| Electrode Material | Stainless steel disk electrodes with integrated anode indicator |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BTX Specialized Electroporation Electrodes |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 2000 |
| Flow Range | 0.2–4 L/min (O₂) |
| Mounting | 5-Point Castor Base with MRI-Compatible Option Available |
| Compliance | FDA-Cleared Materials, ISO 13485–Aligned Manufacturing |
| Configuration Options | Single O₂, Dual O₂, O₂ + Air, O₂ + NO, MRI-Safe Variant |
| Standard Circuit | Jackson-Rees Non-Rebreathing (2 L bag, Cat. #72-3073) |
| CO₂ Absorption | Sealed Canister with Optimized Soda Lime Exposure Geometry |
| Surface Finish | Electrostatic Powder-Coated, Cleanroom-Compatible |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model Range | CDS2000, CDS9000, Vaporstick Plus Desktop, Table Top Series |
| Flow Rate Range | 0.2–4 L/min (O₂), 0–1000 mL/min (auxiliary gases) |
| CO₂ Absorber Capacity | ≥900 mL (CDS9000) |
| Vaporizer Compatibility | ISO-standard 100-series isoflurane/sevoflurane vaporizers (e.g., Harvard 100 Series, Tech3/Tech4, Ohio) |
| Dimensions (CDS2000) | 133.35 cm H × 66.04 cm W (base diameter) |
| Dimensions (Desktop Models) | 30.48 cm W × 20.32 cm D × 38.1 cm H (Vaporstick Plus) |
| Regulatory Compliance | FDA-cleared materials, CE-marked, ISO 13485-manufactured, GLP-ready architecture |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range (O₂) | 0.2–4 L/min |
| Vaporizer | 100 Series Isoflurane Vaporizer (≥250 mL capacity, ±0.5% output accuracy) |
| CO₂ Absorbent Canister Volume | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Fresh Gas Outlet | Yes |
| Inhalation/Exhalation Ports (Closed-Circuit) | Yes |
| Pop-off Valve | Adjustable, provides continuous −2 cm H₂O baseline pressure for rebreathing bag |
| Oxygen Bypass Switch | Integrated |
| Construction | Anodized matte-finish aluminum chassis |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | DHV1000 |
| Dimensions | 76.2 cm H × 40.6 cm W × 40.6 cm D |
| Weight | 20.4 kg |
| Power Supply | 100–220 V, 50/60 Hz |
| Compliance | MRI-compatible variant available |
| Included Accessories | 116.8 cm ventilator-to-bag hose (5.1 cm ID), 61 cm O₂ hose with DISS female connectors, power pack (P/N 32411B10), bellows assembly (P/N 32423C7), custom mounting bracket, descending bellows mechanism |