Thermo Fisher Arena60 Fully Automated Industrial Biochemical Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Thermo Fisher
Origin Finland
Manufacturer Thermo Fisher Scientific
Origin Category Imported
Model Arena60
Instrument Type Beverage & Food Biochemical Analyzer
Throughput Up to 600 tests/hour
Wavelength Range 340–880 nm
Sample Positions 84 (including 20 calibrator + 19 control positions)
Refrigerated Reagent Positions 45
Incubation Capacity 20 cuvettes per cycle, 240 tests per incubation batch
Multiwell Cuvette Capacity 175 strips (2100 total tests)
Onboard Operation Time Up to 4 hours
Dilution Capability Integrated primary and secondary auto-dilution
Water Consumption <2.0 L/h
Barcode Reader Built-in
Reagent Management Real-time reagent volume monitoring
Cuvette Type Disposable multi-cuvette strips (low-volume, cross-contamination-free)

Overview

The Thermo Fisher Arena60 Fully Automated Industrial Biochemical Analyzer is an open-platform clinical-grade analyzer engineered for high-throughput, precision biochemical analysis in food, beverage, pharmaceutical, and chemical manufacturing environments. Leveraging core photometric measurement principles derived from clinical diagnostics—specifically endpoint and kinetic colorimetric assays—the Arena60 applies rigorously adapted fluidics, thermal control, and optical detection architectures to meet the reproducibility, robustness, and regulatory traceability demands of industrial quality control laboratories. Unlike benchtop clinical analyzers, the Arena60 integrates industrial-specific hardware features including refrigerated reagent storage, barcoded sample tracking, low-volume disposable multi-cuvette strips, and extended unattended operation capability—enabling seamless integration into GLP-compliant QC workflows and GMP-aligned production support systems.

Key Features

  • Throughput-optimized design delivering up to 600 tests per hour with minimal operator intervention
  • Programmable incubation temperature control (typically 37°C ±0.1°C) and customizable reaction timing for kinetic and endpoint assays
  • Dedicated dual-carrier architecture: independent sample carousel (84 positions) and refrigerated reagent carousel (45 positions at 4–8°C)
  • Integrated calibration and quality control management: 20 dedicated calibrator positions and 19 fixed control positions for routine verification per run
  • Broad-spectrum photometry using a solid-state spectrophotometer with selectable wavelengths from 340 nm to 880 nm (1 nm increments), supporting NADH, p-nitrophenol, o-dianisidine, and other industry-standard chromophores
  • Disposable multi-cuvette strip system (12-cuvette strips) with ≤120 µL reaction volume per test—eliminating carryover contamination and reducing reagent consumption by ≥40% versus traditional flow-cell systems
  • Onboard auto-dilution module supporting both primary dilution (1:2 to 1:100) and secondary dilution (1:2 to 1:10) with programmable diluent selection and real-time volume validation
  • Self-contained water supply system with 5-L reservoir; operational water consumption <2.0 L/h—no permanent plumbing required

Sample Compatibility & Compliance

The Arena60 accepts liquid samples in standard 13 mm × 100 mm tubes or barcode-labeled microtubes compatible with ISO/IEC 15189 and CLSI GP26-A3 preanalytical guidelines. It supports direct analysis of undiluted soft drinks, fruit juices, wine musts, dairy-based beverages, syrups, and fermentation broths without pretreatment in most routine assays (e.g., glucose, fructose, sucrose, ethanol, organic acids, sulfites, total acidity). All assay protocols are fully customizable to align with AOAC Official Methods, EN 13697, ISO 21527-2, and USP analytical instrument qualification requirements. The system maintains full audit trail functionality compliant with FDA 21 CFR Part 11 for electronic records and signatures when deployed in regulated environments.

Software & Data Management

ArenaLink™ software provides a validated, role-based interface supporting method development, calibration curve generation (linear, log-log, 4-/5-parameter logistic), QC rule application (Westgard rules), and automated result flagging. Raw absorbance data, reaction kinetics curves, and dilution logs are stored in a relational database with timestamped user actions and system event logs. Data export complies with ASTM E1384 and ISO/IEC 17025 reporting standards—including PDF/PDF/A reports with embedded digital signatures, CSV exports for LIMS integration, and HL7 v2.5 messaging for enterprise laboratory information systems. Software validation documentation (IQ/OQ/PQ protocols) is available upon request for GxP implementation.

Applications

  • Real-time monitoring of sugar profiles (glucose, fructose, sucrose) in juice blending and soft drink formulation
  • Alcohol content quantification in wine, beer, and distilled spirits via enzymatic ethanol oxidation
  • Sulfite residual testing in white wines and cider according to OIV-MA-AS313-01A
  • Organic acid profiling (lactic, acetic, citric) in fermented beverages and dairy alternatives
  • Total acidity titration surrogate assays for rapid screening in vinegar and kombucha QC
  • Enzyme activity assays (e.g., invertase, pectinase) used in process optimization and raw material specification
  • Stability testing of functional ingredients (vitamins, polyphenols) under accelerated shelf-life conditions

FAQ

Is the Arena60 compliant with FDA 21 CFR Part 11 for electronic records?

Yes—the ArenaLink software includes configurable electronic signature workflows, immutable audit trails, and secure user authentication meeting all technical and procedural requirements of 21 CFR Part 11.
Can I develop and validate my own assay methods on the Arena60?

Yes—the system is fully open: users may define custom reagents, calibrators, reaction protocols, wavelength pairs, and calculation algorithms within the validated method editor.
What maintenance is required beyond daily cleaning and calibration?

Preventive maintenance is recommended every 6 months by Thermo Fisher Field Service Engineers, including photometer verification, pipetting accuracy checks, and incubation temperature calibration—documentation aligns with ISO/IEC 17025 Clause 6.4.
Does the Arena60 support connectivity to a central LIMS?

Yes—it supports bidirectional HL7 v2.5, ASTM E1384, and TCP/IP-based file transfer protocols for seamless integration with major LIMS platforms including LabVantage, STARLIMS, and Thermo Fisher SampleManager.
Are consumables proprietary or third-party compatible?

Only the multi-cuvette strips and reagent kits supplied by Thermo Fisher are qualified for use; non-OEM consumables void warranty and invalidate regulatory compliance claims due to optical and dimensional tolerances critical to photometric accuracy.