Empowering Scientific Discovery

Titan HDC-15K (LCD) Benchtop High-Speed Centrifuge

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model HDC-15K (LCD)
Instrument Type Benchtop Centrifuge
Speed Range High-Speed (10,000–30,000 rpm)
Max. Speed 15,000 rpm
Max. RCF 21,180 × g
Max. Capacity 10 × 5 mL
Rotor Configuration Fixed-Angle Rotor
Dimensions (W×D×H) 280 × 360 × 250 mm

Overview

The Titan HDC-15K (LCD) is a compact, high-performance benchtop centrifuge engineered for routine and research-grade separation tasks in life science, clinical diagnostics, and quality control laboratories. It operates on the principle of sedimentation under controlled rotational acceleration, utilizing fixed-angle rotor geometry to generate reproducible relative centrifugal force (RCF) profiles across sample tubes. Designed for precision and operational stability at speeds up to 15,000 rpm—delivering a maximum RCF of 21,180 × g—the instrument supports rapid pelleting of cellular components, microorganisms, subcellular organelles, and precipitated macromolecules. Its rigid aluminum alloy housing, brushless DC motor, and active rotor imbalance detection system ensure mechanical integrity and long-term reliability under repeated high-speed operation.

Key Features

  • Intuitive LCD touchscreen interface with real-time display of speed (rpm), RCF (×g), time remaining, and temperature (if equipped with refrigeration option—note: standard HDC-15K is air-cooled, non-refrigerated)
  • Brushless DC motor delivering quiet operation (<65 dB(A) at 15,000 rpm), extended service life, and minimal maintenance requirements
  • Automatic rotor identification and speed/RCF interlock prevents overspeeding and ensures compliance with ISO 15195:2022 safety guidelines for laboratory centrifuges
  • Electronic braking system with adjustable deceleration profiles to protect sensitive pellet integrity during stop cycles
  • Robust aluminum rotor chamber with corrosion-resistant coating and integrated condensate drainage channel
  • Pre-set protocols for common applications (e.g., blood serum separation, bacterial pellet recovery, nucleic acid precipitation) accessible via one-touch recall

Sample Compatibility & Compliance

The HDC-15K accommodates standard conical-bottom polypropylene or polycarbonate tubes (0.2–5 mL), with optimal performance validated for 5 mL tubes in its 10-position fixed-angle rotor (angle: 45°). Tube compatibility extends to certified autoclavable and DNase/RNase-free variants, supporting GLP-compliant workflows. The centrifuge conforms to IEC 61010-1:2010 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) and carries CE marking under the EU Machinery Directive 2006/42/EC. While the base model is unrefrigerated, it meets ambient thermal stability requirements per ASTM E2917–22 for non-temperature-controlled centrifugation systems used in routine QC testing.

Software & Data Management

The HDC-15K features embedded firmware with audit-trail-capable operation logging (timestamp, user ID, rotor ID, speed, time, RCF, and run status), exportable via USB port in CSV format. Though not equipped with network connectivity or remote control capability, its local data storage retains the last 100 run records with tamper-evident timestamps—supporting internal validation and FDA 21 CFR Part 11-aligned documentation practices when paired with lab-wide electronic lab notebook (ELN) integration. Firmware updates are performed offline via USB drive, ensuring version traceability and cybersecurity compliance in regulated environments.

Applications

  • Routine serum/plasma separation from whole blood samples in clinical chemistry labs
  • Pelleting of E. coli, yeast, and mammalian cells prior to lysis or RNA/DNA extraction
  • Clarification of cell lysates and protein supernatants in upstream bioprocessing QA/QC
  • Concentration of viral particles and exosomes in virology and extracellular vesicle research
  • Removal of insoluble aggregates from antibody or recombinant protein preparations
  • Preparative centrifugation in pharmaceutical stability studies per ICH Q5C guidelines

FAQ

Is the HDC-15K refrigerated?
No—the standard HDC-15K (LCD) is an air-cooled, non-refrigerated benchtop centrifuge. A refrigerated variant (HDC-15KR) is available upon request, operating within a 4–30 °C range.
Can I use this centrifuge for PCR tube formats?
Yes—while optimized for 5 mL conical tubes, the fixed-angle rotor accepts adapters for 0.2–2.0 mL PCR strip tubes and individual tubes, provided total mass balance is maintained per ISO 20957-3:2021.
Does the instrument support rotor calibration verification?
Yes—built-in tachometer calibration mode allows verification against external optical tachometers; calibration certificates are issued with each rotor batch per ISO/IEC 17025-accredited procedures.
What safety certifications does the HDC-15K hold?
It complies with IEC 61010-1:2010, carries CE marking, and meets EN 61326-1:2013 for electromagnetic compatibility in laboratory environments.
Is rotor lifetime tracked by the system?
Yes—the firmware logs cumulative rotor revolutions and flags service intervals at 10,000 hours or 50,000 runs, aligning with manufacturer-recommended maintenance schedules per ISO 15195 Annex B.