Empowering Scientific Discovery

Titan MST-80 Microplate Incubator Shaker

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Instrument Type Full-Temperature Incubator Shaker
Timer Range 0–99 h 59 min
Oscillation Frequency 200–1500 rpm
Orbital Amplitude 2 mm
Temperature Control Range Ambient +5°C to 80°C
Platform Quantity 1

Overview

The Titan MST-80 Microplate Incubator Shaker is an engineered platform for precise temperature-controlled orbital shaking of standard microplates (96-well, 384-well, and compatible deep-well formats). Designed for life science laboratories requiring reproducible kinetic assays, cell-based screening, enzyme kinetics, solubility studies, and microbial culture expansion, the device integrates Peltier-based heating with high-resolution DC motor-driven orbital motion. Its thermally uniform chamber—validated across the full operating range—ensures stable thermal environments without external calibration drift, while the low-profile oscillation mechanism minimizes liquid splashing and meniscus disruption during prolonged incubation-shaking cycles.

Key Features

  • Peltier-heating system delivering rapid thermal response and ±0.3°C temperature stability at setpoints between ambient +5°C and 80°C
  • Digitally controlled DC motor enabling continuous, pulse-free oscillation from 200 to 1500 rpm with <±1 rpm speed repeatability
  • Fixed 2 mm orbital amplitude optimized for microplate compatibility—prevents edge-well evaporation and ensures homogeneous mixing in low-volume wells (≥50 µL)
  • Programmable timer supporting durations from 1 minute to 99 hours 59 minutes, with auto-shutdown and audible end-of-cycle alert
  • Single-platform design with universal microplate clamping system accommodating ANSI/SLAS-compliant plates, PCR plates, and custom-fit adapters
  • Robust aluminum alloy housing with insulated chamber walls and passive convection cooling for extended operation under load
  • Front-panel LED interface with real-time display of setpoint temperature, actual chamber temperature, speed, and remaining time

Sample Compatibility & Compliance

The MST-80 supports all standard microplate formats including flat-bottom, round-bottom, V-bottom, and skirted plates. It is routinely deployed in GLP-compliant assay development workflows where traceable environmental control is essential. While not certified to ISO/IEC 17025 or FDA 21 CFR Part 11 out-of-the-box, the instrument’s stable thermal and mechanical performance aligns with method validation requirements under USP , ASTM E2500, and ISO 13485 Annex A for ancillary lab equipment used in diagnostic assay support. Optional calibration certificates (NIST-traceable temperature and speed verification) are available upon request.

Software & Data Management

The MST-80 operates as a standalone unit with no embedded software or network connectivity. All parameters are configured manually via the front panel; no drivers, USB interfaces, or proprietary applications are required. This architecture eliminates cybersecurity risks associated with connected instruments and ensures long-term operational continuity in regulated environments where software validation is cost-prohibitive. For labs requiring electronic recordkeeping, external data loggers (e.g., calibrated thermocouple arrays with timestamped CSV export) may be integrated via standard 4–20 mA or 0–5 V analog outputs on optional I/O modules.

Applications

  • Cell-based assays requiring simultaneous temperature maintenance and gentle agitation (e.g., suspension cell passaging, transfection optimization)
  • Enzyme-linked immunosorbent assay (ELISA) plate incubation with shaking to enhance antigen-antibody binding kinetics
  • Solubility and dissolution profiling of small-molecule compounds in 96-well format under physiological or accelerated conditions
  • Microbial growth curve analysis in microaerophilic or aerobic cultures using sealed plates with gas-permeable seals
  • Protein aggregation studies monitored by turbidity or fluorescence, where consistent thermal history and mixing uniformity are critical
  • Library screening workflows involving compound dilution series, where evaporation control and well-to-well consistency directly impact Z’-factor reliability

FAQ

Is the MST-80 compatible with PCR plates and low-profile microplates?
Yes—the platform includes adjustable clamping rails that accommodate ANSI/SLAS-standard plates ranging from 0.5 mm to 2.5 mm total height, including full-skirted PCR plates and shallow 384-well formats.
Does the unit support cooling below ambient temperature?
No—the MST-80 is a heating-only incubator shaker. Its Peltier system operates exclusively in heating mode; refrigeration is not implemented.
Can multiple MST-80 units be synchronized for parallel runs?
Synchronization is not supported natively. Each unit operates independently with its own timer and setpoint controls. For coordinated multi-unit protocols, external programmable logic controllers (PLCs) or master-timer relays are recommended.
What maintenance is required for long-term reliability?
Routine cleaning of the chamber interior and platform surface with 70% ethanol is advised. The DC motor requires no lubrication; annual inspection of thermal sensor contact points and fan intake filters is sufficient for >5 years of continuous operation.
Is the instrument suitable for use in biosafety cabinets?
Yes—its compact footprint (290 × 270 × 220 mm), low heat dissipation (<65 W nominal), and absence of internal fans make it compatible with Class II A2 and B2 biosafety cabinets when installed with adequate clearance for airflow.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0