Empowering Scientific Discovery

TraceClean Acid Reverse-Flow Cleaning System by Milestone

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Milestone
Origin Italy
Model TraceClean
Type Automated Ultra-Trace Acid Cleaning System for Analytical Vessels
Compliance Designed for ISO/IEC 17025 and GLP Laboratories
Application Scope TFM, PFA, Quartz, and Fused Silica Vessels Used in ICP-MS, ICP-OES, and HR-ICP-MS Analysis
Acid Compatibility HNO₃, HCl, HF (with optional corrosion-resistant configuration)
Cycle Time ≤ 60 min per batch
Blank Performance Sub-ppt metal contamination levels (e.g., <0.1 pg/mL Cr, Fe, Ni, Cu, Zn, Cd, Pb in rinsate)
Chamber Sealing Motorized pneumatic lid with pressure-sensing interlock
Waste Handling Integrated acid-resistant waste reservoir with level sensor and neutralization option
Exhaust Management Built-in condenser-cooled fume extraction with HEPA + acid-scrubbing filter stack

Overview

The TraceClean Acid Reverse-Flow Cleaning System is an engineered solution for laboratories performing ultra-trace elemental analysis—particularly those operating ICP-MS, HR-ICP-MS, and ICP-OES platforms where procedural blanks directly limit detection capability. Unlike conventional ultrasonic or manual acid soaking methods, TraceClean employs a controlled, closed-loop reverse-flow vapor-phase cleaning principle: high-purity acids (HNO₃, HCl, or HF) are sub-boiling distilled inside a sealed quartz-lined chamber, generating saturated acid vapor that flows upward against gravity—counter to the direction of typical convection—ensuring uniform, non-turbulent contact with vessel interiors. This thermodynamically stable逆流 (counter-current) vapor path maximizes surface residence time while minimizing aerosol generation and cross-contamination risk. The system is purpose-built for cleaning low-extractable, high-purity consumables—including TFM and PFA microwave digestion vessels, quartz cyclonic spray chambers, nickel or platinum sample introduction cones, fused silica torch injectors, and quartz ICP nebulizer tubing—without mechanical agitation or liquid immersion that could induce leaching or micro-scratching.

Key Features

  • Automated sub-boiling acid distillation with PID-controlled temperature ramping (range: 80–120 °C, resolution ±0.5 °C) to maintain consistent vapor saturation without boiling over.
  • Reverse-flow vapor architecture ensures laminar, gravity-opposed transport—validated via thermal imaging and tracer gas mapping—to eliminate dead zones in complex geometries such as tapered cones or narrow-bore tubing.
  • Integrated pneumatic lid actuation with real-time pressure monitoring and safety interlocks prevents accidental opening during active vapor cycles.
  • Onboard acid dosing module with gravimetric feedback delivers precise acid volumes (±0.2 mL accuracy) per cycle; compatible with dual-acid sequential protocols (e.g., HNO₃ rinse followed by HF etch).
  • Condenser-cooled exhaust system maintains chamber vacuum stability while recovering >92% of volatile acid for reuse—reducing reagent consumption and lowering annual acid disposal volume by ~40% versus open-beaker reflux.
  • Corrosion-resistant internal construction: electropolished 316L stainless steel frame, quartz-lined reaction chamber, and Hastelloy C-276 valve manifolds for HF-compatible operation.

Sample Compatibility & Compliance

TraceClean accommodates standard and custom analytical vessels up to 500 mL capacity, including Milestone UltraClean™ PFA vials, Savillex® TFM digestion tubes, SCP Science quartz cyclones, and PerkinElmer quartz torch assemblies. All cleaning protocols are documented per ISO/IEC 17025 clause 7.2.2 (method validation) and support GLP audit requirements through full traceability of acid lot numbers, cycle timestamps, temperature logs, and operator ID. The system meets CE machinery directive 2006/42/EC and complies with OSHA 29 CFR 1910.1200 (Hazard Communication) when used with appropriate PPE and facility ventilation. Optional 21 CFR Part 11-compliant software package provides electronic signatures, audit trails, and data integrity controls for regulated pharmaceutical and environmental testing labs.

Software & Data Management

The embedded TouchLogic™ control interface (7″ capacitive touchscreen) stores up to 200 customizable cleaning protocols with parameter locking, version control, and user-level access permissions (admin/operator/auditor). Each cycle generates a timestamped .CSV log containing chamber pressure, vapor temperature profile, acid mass consumed, condensate recovery rate, and door open/close events. Logs export directly to LIMS via Ethernet or USB; optional API integration supports bidirectional communication with LabWare LIMS and Thermo Fisher SampleManager. Raw data files are SHA-256 hashed and stored in write-once/read-many (WORM) mode to satisfy ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available).

Applications

  • Pre-cleaning of ICP-MS sample introduction components to reduce polyatomic oxide interferences (e.g., CeO⁺/Ce⁺ ratio improvement from 3.2% to <0.4%).
  • Routine decontamination of high-value quartz accessories after U-Pb geochronology digestions involving hydrofluoric acid.
  • Blank minimization for EPA Method 1638 (trace elements in biological tissues) and ASTM D5685 (petroleum trace metals).
  • Reconditioning of used PFA vials in clinical metallomics workflows where endogenous Zn/Cu ratios must be resolved at sub-femtomolar concentrations.
  • Validation of cleaning efficacy via ICP-MS rinse solution analysis—system performance verified using NIST SRM 3100 series multi-element standards spiked into post-cycle rinsates.

FAQ

What acid types are validated for use with TraceClean?
HNO₃ (≥69%), HCl (≥37%), and HF (≤49%) are fully supported; HF operation requires the optional Hastelloy C-276 upgrade kit and dedicated exhaust filtration.
Can TraceClean clean assembled ICP torches or only disassembled components?
It cleans fully assembled quartz torches (including injector tubing), provided outer diameter does not exceed 32 mm and total length remains under 250 mm.
How is blank performance verified post-cleaning?
Each instrument shipment includes a Certificate of Blank Performance, reporting rinse solution analysis (per ASTM D5685 Annex A1) for 12 priority elements measured by quadrupole ICP-MS under standardized conditions.
Is remote monitoring available?
Yes—via optional Ethernet-connected WebServer module enabling real-time cycle status viewing, alarm notifications, and historical log retrieval through any modern browser.
Does TraceClean require external chilled water or compressed air?
No. All cooling is achieved via integrated thermoelectric condensers; pneumatic lid actuation uses built-in oil-free diaphragm pump (no shop air required).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0