Empowering Scientific Discovery

Viqua VT1 Ultraviolet Water Disinfection System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Viqua
Origin Imported
Manufacturer Type Authorized Distributor
Model VT1
Pricing Available Upon Request

Overview

The Viqua VT1 Ultraviolet (UV) Water Disinfection System is an NSF/ANSI 55 Class A-certified, low-pressure, high-output UV disinfection unit engineered for point-of-entry (POE) treatment of municipal or pre-filtered potable water. It operates on the principle of germicidal ultraviolet irradiation at 254 nm—a wavelength proven to inactivate bacteria, viruses, and protozoan cysts—including Escherichia coli, Legionella pneumophila, Giardia lamblia, and Cryptosporidium parvum—by disrupting nucleic acid structure and preventing replication. Unlike chemical disinfectants, UV treatment introduces no residual byproducts, alters no taste or odor, and requires no handling of hazardous substances. The VT1 is designed for continuous, non-chemical microbial control in applications where regulatory compliance, operational simplicity, and consistent log-reduction performance are critical.

Key Features

  • Germicidal UV lamp emitting at 254 nm with quartz sleeve protection for optimal transmittance and thermal stability
  • Integrated UV intensity sensor with real-time monitoring and automatic dose calculation based on flow rate and UV transmittance (UVT)
  • Digital controller with LED display showing lamp status, cumulative operating hours, system faults, and UV dose (mJ/cm²)
  • Automatic lamp shutdown and audible/visual alarm upon failure to meet minimum required UV dose (≥30 mJ/cm² per NSF/ANSI 55)
  • Stainless steel 304 reactor chamber with sanitary internal finish and NSF-certified wetted materials
  • Flow-rated design supporting up to 12 GPM (45.4 L/min) at ≥90% UVT; compatible with standard 1″ NPT inlet/outlet connections
  • Low-energy, instant-start lamp technology with typical service life of 9,000–12,000 hours under continuous operation

Sample Compatibility & Compliance

The VT1 is validated for use with municipally treated or pre-filtrated water sources meeting ANSI/NSF Standard 55 Class A requirements: turbidity ≤1 NTU, iron ≤0.3 ppm, hardness ≤7 gpg, manganese ≤0.05 ppm, and UV transmittance ≥75% at 254 nm. Pre-filtration (e.g., 5 µm sediment filter + carbon block) is mandatory to ensure optical clarity and prevent sleeve fouling. The system complies with NSF/ANSI 55 Class A for microbiological reduction claims and is suitable for installations subject to local health department approval, EPA Ground Water Rule (GWR), and WHO Guidelines for Drinking-water Quality. It supports GLP-aligned operational records when integrated with optional data logging modules compliant with FDA 21 CFR Part 11 audit-trail requirements.

Software & Data Management

The VT1’s embedded microcontroller provides local event logging—including lamp start/stop cycles, UV intensity deviations, sensor calibration flags, and alarm triggers—with timestamped entries retained for ≥12 months. While the base unit does not include cloud connectivity, it supports RS-485 Modbus RTU output for integration into building management systems (BMS) or SCADA platforms. Optional Viqua Connect modules enable remote monitoring via secure web interface, configurable email/SMS alerts, and exportable CSV reports for QA/QC documentation. All firmware updates follow ISO/IEC 17025-aligned validation protocols, and configuration changes are protected by password-controlled access levels aligned with IEC 62443-3-3 security principles.

Applications

  • Residential POE disinfection for single-family homes and multi-unit dwellings
  • Commercial foodservice settings including restaurants, cafés, and catering facilities requiring NSF-certified water safety assurance
  • Healthcare environments such as outpatient clinics and dental offices where supplemental disinfection augments municipal supply reliability
  • Educational institutions—including K–12 schools and universities—seeking sustainable, chemical-free water treatment solutions
  • Hospitality infrastructure including hotels, resorts, and recreational facilities with centralized potable water distribution
  • Office buildings and mixed-use developments integrating green building standards (LEED v4.1 Water Efficiency credits)

FAQ

Does the VT1 require pre-filtration?
Yes. A minimum of 5-micron particulate filtration is required upstream to protect the quartz sleeve from scaling and fouling. Additional carbon filtration is recommended if chlorine or organic compounds are present.
What maintenance intervals are recommended?
The UV lamp should be replaced annually or after 9,000 operating hours, whichever occurs first. The quartz sleeve must be inspected and cleaned quarterly; replacement is advised every 2 years or when visual inspection reveals persistent deposits.
Can the VT1 be used with well water?
Only if the well water has been tested and confirmed to meet NSF/ANSI 55 input water quality criteria—including UVT ≥75%, iron ≤0.3 ppm, and absence of hydrogen sulfide—and is preceded by appropriate pretreatment (e.g., iron removal, oxidation, and fine filtration).
Is third-party validation documentation available?
Yes. Viqua provides full NSF International certification reports, UV dose validation test data per DVGW W294 and USEPA UV Guidance Manual protocols, and material compliance declarations (FDA 21 CFR 177.2420, NSF/ANSI 61).
How is system performance verified during commissioning?
Verification requires simultaneous measurement of flow rate (using calibrated flow meter), UV transmittance (via spectrophotometer at 254 nm), and real-time UV intensity (with traceable radiometer); calculated dose must exceed 30 mJ/cm² under worst-case conditions.