Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSea-Bird Scientific
OriginImported
Manufacturer TypeAuthorized Distributor
ModelHydro-T
Measurement Range–5 to 45 °C
Initial Accuracy±0.002 °C
Typical Stability<0.002 °C/year
Resolution0.0001 °C
Clock Accuracy±5 seconds/month
BatterySaft LS14500 3.6 V Li-SOCl₂ (hazard-free)
Sampling Capacity15.9M samples
Max Deployment DurationUp to 2 years (dependent on sampling interval)
Housing MaterialEngineering-grade polymer
Pressure Rating1500 m (4900 ft)
Weight0.2 kg (air), 0.05 kg (water)
Calibration11-point NIST-traceable calibration in SBE’s ISO/IEC 17025-accredited thermal calibration bath
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypePortable
Measurement PrincipleIon-Selective Electrode (ISE)
Sensor ArchitectureIntegrated CARTRICAL Cartridge with pH, Temperature, and Selective Electrodes
CalibrationFactory-Calibrated Cartridge
Maintenance Interval~2x per year (typical operation)
Sample HandlingNo pretreatment required
Controller CompatibilitySC100 / SC200 / SC1000 Digital Controllers
Housing MaterialStainless Steel Body with Ryton End Caps
Immersion RatingFully Submersible
Mounting OptionsRod, Chain, or Wall-Mount Kits
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: HACH
Model9123
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
ModelAPA6000
Measurement PrincipleAutomated titration pump coupled with colorimetric detection
Range (Low)0.05–2.0 mg/L Cu²⁺
Range (High)1.0–10.0 mg/L Cu²⁺
Accuracy (Low)±3% or ±0.03 mg/L (whichever is greater)
Accuracy (High)±5% or ±0.05 mg/L (whichever is greater)
Resolution0.001 ppm
Repeatability±3% of reading or <±0.03 mg/L (whichever is greater)
Cycle Time~4 minutes per analysis
DisplayDigital and graphical output calibrated to Cu²⁺ concentration
Sample Flow Rate20–1000 mL/min
Operating Temperature5–50 °C
Relative Humidity≤95% RH, non-condensing
Inlet Pressure0.17–6.9 bar
Calibration FrequencyConfigurable from twice daily to once weekly (calibration duration: ~35 min)
Analog OutputsTwo isolated 4–20 mA outputs
Alarm OutputsTwo SPDT relays
Power Supply95–240 VAC, 50/60 Hz
Enclosure RatingNEMA 4X (IP65)
Mounting OptionsPanel-mount, benchtop, or wall-mount (hardware included)
Data Storage30-day onboard history with trend and graphical analysis capability
Maintenance IntervalUp to 30 days unattended operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelEZ6001 Analyzer
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Instrument TypePortable
Measurement PrincipleCoulometric Titration (Acidic/Alkaline KMnO₄ Method)
Measurement Range0–5000 mg/L as O₂
Accuracy±2% of full scale
Repeatability±2% of full scale
Detection Limit0.2 mg/L
Typical Analysis Time15 minutes
Batch CapacitySingle-sample per run
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusManufacturer
ModelAnatel PAT700
Measurement Range0.5–2,000 ppb C TOC
Repeatability±0.3 ppb or ±1% (whichever is greater)
Accuracy±1 ppb or ±5% (whichever is greater)
TOC Resolution0.1 ppb
Conductivity/Resistivity Resolution0.01 µS/cm or MΩ·cm
Temperature Resolution0.1 °C
Conductivity CompensationTemperature-compensated and non-temperature-compensated modes
Inlet Pressure10–100 psig (69–690 kPa)
Flow Rate60–300 mL/min
Analog OutputsThree 4–20 mA
Digital I/OTwo digital inputs, four digital outputs
Communication InterfacesRS232, USB, Ethernet, Serial printer port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ManufacturerHach Company
Product TypeImported Instrument
ModelHQd Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusOriginal Equipment Manufacturer (OEM)
Model3650EX
Power Supply2 × AA NiCd or alkaline batteries (2.4–3 V DC)
Battery LifeUp to 40 hours continuous operation
Measurement PrincipleElectrochemical amperometric sensing with proprietary membrane-based sensor
Enclosure RatingIP67 / NEMA 4X
CertificationATEX II 1G Ex ia IIC T4 Ga
Temperature Range–5 °C to +100 °C
Output InterfaceRS-232 serial digital interface
Zero Drift< 0.5 % FS per 24 h
Housing MaterialFully stainless steel (316L)
Data LoggingInternal non-volatile memory with PC download capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ModelTitraLab AT1000
Titration TypesPotentiometric (zero-current or controlled-current), Amperometric, Colorimetric
Titration ModesSample, Blank, Sample + Blank, QC Sample, QC Sample + Blank
Measured ParametersmV/pH, Conductivity, Temperature
ResolutionmV/pH: ±0.1 mV / ±0.001 pH
Conductivity±0.5% of reading
Temperature±0.3 °C / ±0.51 °F
Sample HolderIntegrated design with magnetic stirring
max. beaker capacity250 mL
Electrode InputsDual-channel
Burette Capacities2.5 / 5 / 10 / 25 mL (ISO 8655-3 compliant)
Motor Resolution20,000 steps with microstepping (128 μsteps/step)
Calibration ModesElectrode & titrant calibration — automatic, fixed-point, or user-defined (up to 5 points)
Calibration SchedulingConfigurable interval-based alerts and reminders
Data StorageLast 100 measurements (samples, blanks, QC samples) + last 10 calibrations, including timestamp, operator ID, sample ID
Data ExportUSB drive
Interface5.7" color VGA touchscreen
Calibration Curve DisplayDirect or derivative plots
Connectivity2× electrode ports, 2× USB, 1× RS-232, 1× Ethernet
Dimensions (H×W×D)220 × 400 × 360 mm
Weight4 kg
Power Supply100–240 V AC, 50/60 Hz
Operating Environment15–35 °C, 20–80% RH (non-condensing)
Storage Range−5–40 °C
Safety CertificationIEC/EN 61010-1
EMC ComplianceIEC/EN 61326-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ApplicationLaboratory Use
Measured ParameterTotal Phosphorus
Measurement PrincipleAcidic Persulfate Digestion + Ammonium Molybdate Colorimetry at 880 nm
Measurement Range0.01–3.8 mg/L as PO₄–P
Accuracy<2% at 1 mg/L
Detection Limit0.01 mg/L
Resolution0.001 mg/L
Sample pH Range2–10
Digestion Conditions150 °C, 6 bar
Particle ToleranceUp to 100 µm
Calibration MethodSingle- or Multi-point
Auto-sampler Options36-position (with stirring) or 53-position (without stirring)
DisplayColor LCD
Weight40 kg (digestion/analysis unit), 5 kg (auto-sampler)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ManufacturerHach Company
Product TypeImported
ModelCL17D Residual and Total Chlorine Analyzer – Distribution Network Version
Instrument TypeOnline Analyzer
Measurement PrincipleDPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine)
Measured ParameterResidual Chlorine / Total Chlorine
Range0–5 mg/L as Cl₂
Accuracy±5% or ±0.005 mg/L as Cl₂ (whichever is greater)
Repeatability±0.035 mg/L or ±5% as Cl₂ (whichever is greater)
Detection Limit0.035 mg/L as Cl₂
Sample Temperature Range5–40 °C
Cycle Time10 minutes
Analog Output4–20 mA (configurable across 0–5 mg/L range)
Alarm OutputsTwo user-configurable concentration alarms, each with SPDT relay (5 A, 230 VAC)
Dimensions42 × 32 × 18 cm
Turbidity & Color CompensationAutomatic
CalibrationBuilt-in calibration curve
Diagnostic CapabilitySelf-diagnostic system
Reagent LifetimeUp to 120 days (unopened)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTrojan
OriginImported
Manufacturer TypeAuthorized Distributor
ModelTrojanUVSigna
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelCA9400 Single-Channel / Dual-Channel Transmitter
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelEclox
Instrument TypePortable
Biological Indicator*Aliivibrio fischeri* (freeze-dried, ISO 11348-compliant)
Operating Temperature Range−20 °C to +55 °C
IP RatingIP67
Weight1.4 kg (instrument only, with batteries)
Dimensions230 × 77 × 125 mm (instrument)
Power Supply4 × AA alkaline batteries (≥250 tests per set)
DisplayBacklit graphical LCD
Data Storage32 KB non-volatile memory
InterfaceRS232 serial output
Measurement TimeDefault 15 s (configurable: 6–20 s)
Toxicity Screening Range0–100% inhibition (linear response: 10–90%)
Screening Assay Duration5, 15, or 30 min
CertificationCE Marked
Bacterial Reagent Storage−18 °C (12 months)
Reagent Shelf LifeChemical luminescence reagents — 24 months at room temperature
Additional Onboard ParametersResidual chlorine, total chlorine, arsenic (colorimetric), pH, conductivity (TDS), platinum-cobalt color, organophosphate nerve agents, carbamate insecticides
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
ModelminiLab pH Meter
Instrument TypePortable
Parameter TypesMulti-parameter
Sensor TechnologyISFET (Ion-Sensitive Field-Effect Transistor)
HousingIP67-rated waterproof enclosure
Temperature CompensationAutomatic (ATC)
Electrode DesignReplaceable reference electrode
StorageDry storage compatible (no electrolyte filling required)
Calibration1–3 point calibration with standard buffers (pH 4.01, 7.00, 10.01)
DisplayLCD with backlight
Power SourceCR2032 coin cell battery (typical life >1,000 measurements)
ComplianceDesigned to support GLP-compliant data recording when used with optional software interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS100-UMB
Measurement Principle24 GHz Doppler radar-based particle detection
Power SupplyDC 12–36 V (solar-compatible)
Operating Temperature−40 °C to +70 °C
Heating FunctionIntegrated radar dome heater
Communication ProtocolsModbus RTU, SDI-12, CAN, ASCII, MQTT (optional)
IP RatingIP66
MaintenanceNo moving parts, maintenance-free design
ComplianceCE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Instrument TypePen-style
Parameter TypesDual (pH & ORP)
Measurement RangepH 0–14, ORP −1500 to +1500 mV
Resolution0.01 pH
Calibration BufferspH 4.01, 7.00, 10.01
Sensor InterfaceDigital (HACH SC Series Protocol)
Cable Length4.5 m integrated
Digital Adapter IncludedPart #6120600 (for legacy analog sensor retrofit)
Temperature CompensationIntegrated Pt1000 RTD
Housing MaterialsRyton®, PVDF, or 316SS/PVDF (model-dependent)
ComplianceDesigned for ASTM D1293, ISO 10523, USP <791>, and EPA 150.1–compliant monitoring workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginUSA
ManufacturerHACH Company
Product TypeImported Instrument
ModelPolymetron 9210
PricingUpon Request
Measurement Range0–1000 ppb or 0–5000 ppb SiO₂
Repeatability±0.5 ppb / ±2 ppb
Detection Limit<0.5 ppb / <2 ppb
Cycle Time10 min per channel
Operating Pressure0.2–2 bar
Operating Temperature5–50 °C
Sample Flow Rate15–20 L/h
Communication InterfaceRS-485
Analog Output4–20 mA
Channel Capacity1–6 channels
CalibrationDual-point (chemical zero & slope)
Data LoggingIntegrated memory with timestamped records
User InterfaceGraphical menu with intuitive navigation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Measurement PrincipleCoulometric Titration with Acidic Potassium Permanganate Oxidation
Range0–20 / 40 / 100 / 200 / 400 / 1000 mg/L as O₂
Repeatability±2% RSD
Accuracy±5% of reading
LOD0.4 mg/L
Resolution0.01 mg/L
Single-Test Duration5–10 min
Data Storage100 test records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelAmtax™ Compact
Instrument TypeOnline Analyzer
Measurement PrincipleGas-Phase Separation with Colorimetric Detection (Nesslerization-based)
Range Options0.2–12.0 mg/L NH₄–N
Accuracy±2.5% of reading or ±0.2 mg/L (whichever is greater, per certified standard solution)
Detection Limit0.5 mg/L NH₄–N
Cycle Time13–120 min (user-selectable)
Output Signals4–20 mA (max. load 500 Ω)
Digital InterfacesRS485 / RS232 with Modbus RTU or PROFIBUS DP protocol support
Alarm OutputsTwo programmable relay outputs (24 V DC, 1 A each)
Sample ChannelsDual-inlet capability (two independent sample streams)
Show next