Protein Analysis
Filter
Showing 31–60 of 88 results
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 29-0182-24 |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Absorbance Range | ±6 AU |
| Weight | 48 kg |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pure™ 150T |
| Maximum Flow Rate | 150 mL/min |
| UV Detection Wavelengths | Fixed at 260 nm and 280 nm |
| Software Platform | UNICORN 7 |
| Column Switching Capacity | Up to 10 columns via optional column selection valve |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pure™ T Chromatography System |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Detectors | Dual-wavelength UV monitor (260 & 280 nm), Conductivity monitor, pH monitor |
| Flow Rate Range | ÄKTA pure™ 25T: 0.001–25 mL/min (up to 50 mL/min in column packing mode) |
| ÄKTA pure™ 150T | 0.01–150 mL/min (up to 300 mL/min in column packing mode) |
| Flow Accuracy | ÄKTA pure™ 25T: ±1.2% accuracy, RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| ÄKTA pure™ 150T | ±1.5% accuracy, RSD <0.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP) |
| Pressure Range | ÄKTA pure™ 25T: 0–20 MPa |
| ÄKTA pure™ 150T | 0–5 MPa |
| Conductivity Range | 0.01–999.99 mS/cm |
| pH Measurement | 0–14 pH units, ±0.1 pH accuracy (pH 2–12) |
| Solvent Compatibility | Compatible with ≥1 mol/L NaOH and ≥2 mol/L NaCl for >3 hours of in-place cleaning per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA ready XL |
| Flow Rate Range | 45–3500 L/h |
| Compatible Column ID | up to 1200 mm |
| Primary Application | GMP-compliant large-scale bioprocess purification |
| Software Platform | UNICORN 7+ with OPC UA connectivity |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail, GMP documentation package available |
| Sensor Type | Single-use, calibrated-in-place (CIP) pressure, UV, conductivity, and temperature sensors |
| Footprint | Compact industrial design optimized for multi-product facility integration |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA ready™ 450 |
| System Type | Single-Use Preparative Chromatography Platform |
| Flow Rate Range | 0.01–45 mL/min |
| Hold-Up Volume | < 1.2 mL (system dead volume) |
| Pressure Limit | Up to 20 bar |
| Compliance | Designed for GMP-compliant small-scale bioprocessing |
| Sensor Integration | Integrated single-use conductivity, pH, UV, and temperature sensors |
| Fluidic Path | Pre-sterilized, gamma-irradiated disposable flow path kits |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA ready™ |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTAcrossflow |
| Application Scope | Lab-scale to process-development TFF for protein purification, cell harvesting, UF/DF, and membrane screening |
| Max Total Membrane Area | 150 cm² (3 × 50 cm² cassettes) |
| Minimum Working Volume | 25 mL |
| Control Software | UNICORN v7.x or later |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Fluid Path Materials | USP Class VI-certified elastomers, 316L stainless steel (pump head, valves), single-use compatible |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ avant 150 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.01–150 mL/min (up to 300 mL/min in column packing mode) |
| Flow Accuracy | ±1.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP) |
| Precision | RSD <0.5% |
| Detection Range | UV-Vis detector (190–700 nm, multi-wavelength monitoring), Conductivity detector (0.01–999.99 mS/cm), pH detector (0–14, accuracy ±0.1 pH units within pH 2–12) |
| Pressure Range | 0–5 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours of in-place cleaning per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ go |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.01–25 mL/min |
| Flow Accuracy | ±2% (at 0.25–25 mL/min, 0.7–3 cP) |
| Detection Options | UV monitor (280 nm fixed wavelength), Conductivity monitor (0.01–999.99 mS/cm), pH monitor (range 0–14, accuracy ±0.1 pH units within pH 2–12, ±3°C from calibration temperature) |
| Pressure Range | 0–5 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning per day |
| External Detector Support | Fluorescence detector, refractive index detector, and other third-party detectors |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ pure 25M |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.001–25 mL/min (up to 50 mL/min in column packing mode) |
| Flow Rate Accuracy | ±1.2% (accuracy), RSD <0.5% (precision |
| conditions | 0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| Detection Range | UV detector (190–700 nm multi-wavelength for M-series), conductivity detector (0.01–999.99 mS/cm), pH detector (0–14 range, ±0.1 pH unit accuracy within pH 2–12), optional external detectors (fluorescence, refractive index) |
| Pressure Range | 0–20 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours CIP per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ pure micro |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.001–25 mL/min |
| Flow Accuracy | ±1.2% (absolute), RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| UV Detection Range | 190–700 nm (multi-wavelength) |
| Conductivity Range | 0.01–999.99 mS/cm |
| Optional pH Sensor | 0–14 pH, ±0.1 pH (pH 2–12) |
| Pressure Range | 0–20 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning |
| Internal System Volume | As low as 18 µL (with micro kit) |
| Microfluidic Components | 0.8 µL injection valve, 2.6 µL UV flow cell, 5.4 µL conductivity cell, 0.7 µL outlet valve, 0.6 mL mixer, tubing ID: 0.13 mm or 0.25 mm |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ start |
| Purification Principle | Affinity Chromatography (AC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.5–5 mL/min |
| Flow Accuracy | ±15% at ≤1 mL/min |
| Flow Precision | ±15% at ≤1 mL/min |
| Detection | UV Monitor (280 nm single-wavelength), Conductivity Monitor |
| Pressure Range | 0–0.5 MPa |
| Conductivity Range | 0–300 mS/cm |
| Solvent Compatibility | Compatible with in-place cleaning using 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA™ start |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K SPR System |
| Configuration | Single-injection needle, six-flow-cell platform |
| Regulatory Readiness | Optional GxP-compliant software package (21 CFR Part 11 audit trail enabled) |
| Software | Biacore Insight™ v3.x |
| Service Support | OptiRun™ lifecycle service program |
| Upgrade Path | Compatible with Biacore 1K+ expansion module for enhanced ligand multiplexing and sample throughput |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K+ SPR System |
| Channel Configuration | Single-needle, 6-flow cell architecture |
| Sample Capacity | Dual 96-well microplate support + dual reagent racks |
| Buffer Selection | Integrated automated buffer selector |
| Temperature Control | Precise thermostatic sample compartment |
| Software Platform | Biacore Insight™ with FDA 21 CFR Part 11-compliant audit trail and GLP/GMP-ready data management |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 1S+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Flow Cell Configuration | Six parallel flow cells |
| Detection Range | fM to mM |
| Sample Capacity | Up to two 96-well or 384-well microplates plus 21–43 additional sample positions |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4–37°C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 8K+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | Multi-channel (8 sample needles, 16 simultaneous interaction channels) |
| Detection Range | fM to mM |
| Sample Capacity | Up to 4,608 samples (12 × 384-well plates or 24 × 96-well plates) |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4°C to 40°C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore S200 |
| Instrument Type | Label-Free Molecular Interaction Analyzer |
| Application Focus | Fragment-Based Drug Discovery (FBDD), Kinetic & Affinity Analysis, Epitope Mapping, Competitive Binding Assays |
| Regulatory Context | Designed for GLP-compliant workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore X100 |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | Multi-channel |
| Detection Range | pM–mM |
| Sample Capacity | 15 samples per run |
| Analysis Time | 2–15 minutes per interaction cycle |
| Temperature Control Range | 4–40 °C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | BioProcess pcc 1/2" |
| Control Software | UNICORN™ or DeltaV™ |
| Column Configuration | 3-column (3C) or 4-column (4C) |
| Application | Continuous downstream purification of therapeutic proteins |
| Compliance Framework | Supports FDA 21 CFR Part 11, GMP, and GLP audit trails via software configuration |
| Service Support | OptiRun™ lifecycle service packages available |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | UniFlux™ |
| System Variants | UniFlux™ 10, 30, 120, 400 |
| Membrane Area Range | 0.11–52 m² |
| Feed Volume Capacity | 1–10,000+ L |
| Construction Materials | 316L Stainless Steel, USP Class VI Polymers |
| Control Software | UNICORN™ v7.x or later |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP/GLP-Ready, cGMP-Compatible Design |
| Pressure Monitoring | 4 Real-Time Channels |
| Sensor Integration | Temperature, UV Absorbance, pH, Conductivity, Air Flow, Transmembrane Pressure (TMP), Differential Pressure (ΔP), Crossflow & Permeate Flow Rates |
| Pump Types | Sanitary Diaphragm & Rotary Lobe Pumps |
| Integrity Test | Integrated Air Flow-Based Filter Integrity Testing |
| Cleaning | Fully Automated CIP Method Development & Water Flux Validation |
| Data Management | Audit Trail, Electronic Signatures, 10-Tier User Access Control, Logbook Generation |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MUVIS® |
| Field of View (mm) | 3.7 × 3.0 |
| Pixel Size (µm) | 1.1 |
| Optical Resolution (µm) | 2 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RI1 |
| Field of View (mm) | 6.1 × 5.0 – 1.9 × 1.5 |
| Pixel Size (µm) | 1.8 – 0.56 |
| Optical Resolution (µm) | 5 – 1 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI360 / RI1000 |
| Field of View (mm) | 9.49 – 0.79 |
| Pixel Size (µm) | 3.20 – 0.27 |
| Optical Resolution (µm) | 4.39 – 0.83 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SONICC® |
| Price | Upon Request |
| Field of View (mm) | 2.2 × 2.2 to 0.65 × 0.65 |
| Optical Resolution (µm) | 4.0 to 1.1 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ACC450 |
| Price Range | USD 140,000 – 210,000 |
| Purification Principle | Axial Compression Chromatography |
| Detector Types | UV, pH, Conductivity |
| Detection Capabilities | Integrated multi-channel analog/digital signal acquisition for real-time UV absorbance (280 nm/254 nm), pH (0–14), and conductivity (0–200 mS/cm) |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | Acoulyte |
| Sensor Diameter | 14 mm |
| Substrate | SiO₂-coated QCM-D crystal |
| Sensing Surface | Nanostructured gold |
| Standard Coatings | Si₃N₄, SiO₂, Al₂O₃, TiO₂ |
| Light Source | Tungsten-halogen lamp |
| Wavelength Range | 450–1000 nm |
| LSPR Sensitivity | ≤0.03 monolayer |
| Measurement Spot Diameter | 3 mm |
| Temporal Resolution | 10 Hz (10 samples/s) |
| Typical Noise Level | <0.01 nm |
| Optical Unit Dimensions (W×D×H) | 25×27×9 cm |
| Acoulyte Module Dimensions (W×D×H) | 8×5×3 cm |
| Software | Insplorer (Windows-compatible) |
| Data Export Format | ASCII text |
| Compatible Platforms | Q-Sense Explorer E1 & Analyzer E4 (with Q-Sense Window Module) |
| NPS Sensing Depth | <30 nm |
| QCM-D Hydrodynamic Penetration Depth | >300 nm |
| Simultaneous Output Parameters | LSPR resonance wavelength shift (Δλ), extinction intensity change, frequency shift (Δf), dissipation change (ΔD) |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS Sensor Chip |
| Pricing | Upon Request |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | S2 |
| Analysis Time | 2 s |
| Temperature Control Range | 15 °C–45 °C (±0.1 °C stability) |
| Flow Cell | Dual-channel |
| Sample Dead Volume | 20 µL |
| Standard Syringe Volume | 250 µL |
| Typical Flow Rate | 12.5–250 µL/min |
| Standard Loop Volume | 200 µL |
| Sensor Substrate | Fused Silica |
| Sensing Layer | Nanostructured Gold |
| Detection Depth | Up to 30 nm |
| Light Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Measurement Spot Diameter | 1.5 mm |
| Temporal Resolution | Up to 10 Hz |
| Optical Noise | <0.1 nm (at 1 Hz sampling) |
| Sensor Dimensions | 9.5 × 9.5 × 1 mm |
| System Dimensions | 65 × 42 × 36 cm |
| Weight | 30 kg |
| Software | InControl 1.0 (Windows-compatible) |
| Data Output | Proprietary CSV/TSV format |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | XNano |
| Measurement Principle | Nanoplasmonic Resonance Spectroscopy (NPS) |
| Sample Environment | Liquid or Gas Flow |
| Temperature Range | 25–80 °C (optional up to 250 °C) |
| Chip Substrate | Fused Silica (9.5 × 9.5 × 1 mm) |
| Sensing Surface | Nanostructured Gold |
| Coating Options | Au, SiO₂, Si₃N₄, TiO₂, Al₂O₃ |
| Optical Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Wavelength Range | 450–1000 nm |
| Spot Size | ~2 mm diameter |
| Time Resolution | 10 Hz (10 samples/sec) |
| Noise Level | < 0.01 nm (in liquid, 1 Hz sampling) |
| Flow Cell Volume | ~4 μL |
| Minimum Sample Volume | ~100 μL |
| Typical Flow Rate | 20–100 μL/min |
| Materials | Titanium & Perfluoroelastomer® |
| Dimensions (Measurement Unit) | 31 × 25 × 25 cm |
| Software | Windows-compatible, ASCII output, multi-parameter real-time export (resonance wavelength, linewidth, extinction) |