Protein Analysis
Filter
Showing 61–90 of 140 results
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Go1 |
| Flow Rate | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Detection | 280 nm (±3 nm accuracy, 2 mm pathlength) |
| Conductivity Range | 0–999.9 mS/cm |
| Gradient Formation | High-precision dual-pump gradient system |
| Sample Injection | Automated 3-position, 7-port valve with quantitative loop |
| Fraction Collection | X-Y matrix collector (standard 96-position, 18×150 mm tube compatibility) |
| Software | ClearFirst-3000 Series Workstation (PC-based, method library, user management, audit trail-ready architecture) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Go2 |
| Flow Rate Range | 0.01–50 mL/min (optional up to 100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| UV Detection | Quad-wavelength simultaneous detection |
| Conductivity Range | 0–999.9 mS/cm |
| pH Detector (optional) | with temperature compensation |
| Column Switching | Up to 5-column + 1 bypass position |
| Fraction Collector | X-Y matrix configuration, 96-position standard (18×150 mm tubes), programmable by peak, volume, or manual trigger |
| System Compatibility | Aqueous buffers, viscosity ≤5 cP |
| Software | ClearFirst-3000 Series Workstation (PC-based, method library, user management, audit trail, system self-test) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Max |
| Flow Rate Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Conductivity Range | 0–999.9 mS/cm |
| Column Positions | Up to 5 |
| Buffer Inlets | 16 total (8 per pump) |
| Sample Inlets | 8 |
| Pathlength Options | 2 mm (standard), 5 mm & 10 mm (optional) |
| Fraction Collector Capacity | 96-position 18×150 mm tube rack (standard), 11-position large-volume collection |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Plus |
| Flow Rate Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Conductivity Range | 0–999.9 mS/cm |
| Column Positions | Up to 5 |
| Detection Channels | Quad-wavelength UV-Vis + Conductivity + Optional pH/Pressure |
| Gradient Formation | High-precision dual-pump gradient mixing |
| Fraction Collection | X-Y matrix collector with 96-position 18 mm tube rack (standard), 11-position large-volume collection |
| Compliance | Designed for GLP-compliant workflows, supports audit trail-ready method storage and user management |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Pro |
| Pump Flow Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical Path Lengths | 2 mm (standard), 5 mm & 10 mm (optional) |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Detector | High-precision, dual-electrode design |
| pH Detector (optional) | Temperature-compensated, accuracy优于进口同类产品 |
| Gradient Formation | Precision high-pressure binary gradient mixing |
| Detection Channels | Quad-wavelength simultaneous detection |
| Column Compatibility | Single-column configuration (1-position), optional 6-port column switching valve (5 columns + bypass) |
| Fraction Collector | X-Y matrix format, 96-position rack support (18 × 150 mm tubes or 15 mL conical tubes), programmable peak-, volume-, or manual-triggered collection |
| System Fluidics | Bio-inert PEEK and titanium components, pressure-rated to 27 MPa |
| Software | ClearFirst-3000 Series Workstation (Windows-based, GLP-compliant audit trail, user management, method library, instrument self-diagnosis) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Pro |
| Flow Rate Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Conductivity Range | 0–999.9 mS/cm |
| Path Length Options | 2 mm (standard), 5 mm & 10 mm (optional) |
| Gradient Formation | High-precision dual-pump gradient mixing |
| Detection Channels | Quad-wavelength simultaneous UV-Vis detection |
| Column Compatibility | Single-column configuration (expandable via optional multi-column switching valve) |
| Fraction Collection | X-Y matrix collector with 96-position 18×150 mm tube rack (standard), configurable for multiple tube formats |
| Software | ClearFirst-3000 Series Workstation (Windows-based, GLP-compliant audit trail, method database, user management, instrument self-test) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3200 |
| Flow Rate Range | 0.01–300 mL/min (optional up to 400 mL/min) |
| Max Pressure | 20 MPa (200 bar) at ≤50 mL/min |
| UV Wavelength Range | 190–850 nm |
| UV Wavelength Accuracy | ±1 nm |
| UV Wavelength Repeatability | ±0.2 nm |
| Optical Path Lengths | 2 mm (standard), 5 mm & 10 mm (optional) |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Accuracy | ≤±0.01 mS/cm |
| Buffer Inlets | 4 (dual-pump configuration) |
| Fraction Collector | X-Y matrix, 96-position, compatible with 18×150 mm tubes and 15 mL centrifuge tubes |
| Column Capacity | 1 column (expandable via optional column selector valve) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3500 |
| Flow Rate Range | 0.01–300 mL/min (optional up to 400 mL/min) |
| Pressure Range | 0–20 MPa (0–200 bar) at ≤50 mL/min |
| UV Wavelength Range | 190–850 nm |
| Detection Channels | Quad-wavelength simultaneous detection |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Accuracy | ≤±0.01 mS/cm |
| Column Positions | 5 |
| Buffer Inlets | 4 (2 per pump) |
| Sample Inlets | 8 |
| Fraction Collection | X-Y matrix collector with 12 outlets (11 large-volume + waste), 18 mm tube rack (96-position), temperature-controlled |
| Gradient Formation | High-precision dual-pump gradient generation |
| System Compatibility | Aqueous biological buffers only |
| Software | ClearFirst-3500 Dedicated Workstation (Windows-based, GLP-compliant audit trail, method database, user management, instrument self-test) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-4000 |
| Flow Rate | 0–500 mL/min (optional 0–1000 mL/min) |
| Pressure Range | 0.01–10 MPa (0.1–250 mL/min) |
| UV Detection | Four-wavelength simultaneous detection (190–850 nm), wavelength accuracy ±1 nm, repeatability ±0.2 nm, pathlength 2 mm |
| Conductivity Range | 0–999.9 mS/cm |
| Collection Valve | 7-port high-volume fraction collector |
| Sample Inlet | 8-channel sample selection valve |
| Buffer Selection | 4-channel buffer expansion module |
| pH Detector (optional) | with temperature compensation |
| System Compatibility | Aqueous biological buffers up to 5 cP viscosity |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-4500 |
| Flow Rate (System Pumps) | 0–1200 mL/min |
| Flow Rate (Sample Pump) | 0–600 mL/min |
| Pressure Range | 0.01–2 MPa (20 bar) at ≤600 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical Path Length | 2 mm |
| Conductivity Range | 0–999.9 mS/cm |
| Detection Channels | Quad-wavelength UV-Vis + Conductivity + Optional pH/Pressure |
| Collection Ports | 12-position fraction valve |
| Compliance | Designed for GLP-compliant protein purification workflows under ISO 22367 and USP <1058> analytical instrument qualification guidelines |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ClearFirst-500L |
| Pricing | Available Upon Request |
| Flow Rate Range | 0–40 mL/min |
| Maximum System Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Detection Wavelength | 280 nm (LED-based) |
| Wavelength Accuracy | ±3 nm |
| Optical Path Length | 2 mm |
| Conductivity Range | 0–500 mS/cm |
| Fraction Collector Configurations | 48-position (18 mm × 150 mm tubes), 130-position (1.5 mL tubes), 88-position (13 mm × 100 mm tubes), 80-position (15 mm × 150 mm tubes), 20-position (50 mL tubes) |
| Solvent Compatibility | Aqueous Buffers Commonly Used in Biomolecular Purification |
| Detection Systems | UV (280 nm), Conductivity, Optional pH (with temperature compensation) |
| Control Interface | Android-based Touchscreen Console + Optional PC Software (ClearFirst PC Edition) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-500M |
| Flow Rate | 0–40 mL/min |
| Max Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Wavelength | 280 nm ±3 nm |
| Path Length | 2 mm |
| Conductivity Range | 0–500 mS/cm |
| Fraction Collector | X-Y robotic matrix collector |
| Detector Type | LED-based single-wavelength UV detector |
| Control Interface | Android-based touchscreen workstation |
| System Compatibility | Aqueous biobuffer-compatible fluidic path |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-500Q |
| Flow Rate | 0–40 mL/min |
| Max Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Wavelength | 280 nm ±3 nm |
| Optical Path Length | 2 mm |
| Detector Type | LED-based Single-Wavelength UV Detector |
| Gradient Formation | Precision Three-Position Solvent Selection Valve |
| Control Interface | Embedded Android Touchscreen + Optional PC Software (ClearFirst PC Edition) |
| Sample Compatibility | Aqueous Buffers for Biomolecule Purification |
| Tubing Material | Biocompatible, Low-Adsorption, Pressure-Rated Polymer |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ClearFirst-500S |
| Pricing | Available Upon Request |
| Flow Rate Range | 0–40 mL/min |
| Maximum System Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Detection Wavelength | 280 nm |
| Wavelength Accuracy | ±3 nm |
| Optical Path Length | 2 mm |
| Fraction Collector Capacity | Standard 48-position 18 mm tube rack (18 × 150 mm or 15 mL conical tubes) |
| Optional racks | 130-position 1.5 mL, 88-position 13 mm, 80-position 15 mm, 20-position 50 mL |
| Detector Type | LED-based Single-Wavelength UV Detector |
| Gradient Generation | Precision Three-Port Solvent Selection Valve |
| Control Interface | Embedded Android Touchscreen Workstation (ClearFirst Android Edition) + Optional PC-Based ClearFirst Software (Windows) |
| Compliance | Designed for GLP-compliant workflows |
| Material Compatibility | Biocompatible, pressure-rated fluidic path (PEEK, PTFE, fused silica capillaries, stainless steel fittings) |
| Method Storage | Onboard method library with recall and one-touch execution |
| Detection Options | Optional Conductivity Detector (electrode-based, analog signal processing) |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MUVIS® |
| Field of View (mm) | 3.7 × 3.0 |
| Pixel Size (µm) | 1.1 |
| Optical Resolution (µm) | 2 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RI1 |
| Field of View (mm) | 6.1 × 5.0 – 1.9 × 1.5 |
| Pixel Size (µm) | 1.8 – 0.56 |
| Optical Resolution (µm) | 5 – 1 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI360 / RI1000 |
| Field of View (mm) | 9.49 – 0.79 |
| Pixel Size (µm) | 3.20 – 0.27 |
| Optical Resolution (µm) | 4.39 – 0.83 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SONICC® |
| Price | Upon Request |
| Field of View (mm) | 2.2 × 2.2 to 0.65 × 0.65 |
| Optical Resolution (µm) | 4.0 to 1.1 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ACC450 |
| Price Range | USD 140,000 – 210,000 |
| Purification Principle | Axial Compression Chromatography |
| Detector Types | UV, pH, Conductivity |
| Detection Capabilities | Integrated multi-channel analog/digital signal acquisition for real-time UV absorbance (280 nm/254 nm), pH (0–14), and conductivity (0–200 mS/cm) |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Bio-Lab100 |
| Price Range | USD 42,000 – 70,000 |
| Purification Principle | Low- to Medium-Pressure Liquid Chromatography (LPLC/MPLC) |
| Detector Types | UV-Vis, pH, Conductivity |
| UV Detection Range | 200–400 nm |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Bio-Lab30 |
| Price Range | USD 70,000 – 112,000 (approx.) |
| Purification Principle | Low- to Medium-Pressure Liquid Chromatography (LPLC/MPLC) |
| Detector Types | UV-Vis, pH, Conductivity |
| UV Detection Range | 200–400 nm |
| Flow Rate Range | 0.01–30 mL/min (typical for LPLC systems) |
| Pressure Limit | ≤5 MPa |
| Fraction Collection | Programmable, timed or peak-triggered |
| System Compatibility | FPLC- and AKTA-style method transfer support |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Bio-Lab300 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Detectors | UV, pH, Conductivity |
| UV Wavelength Range | 190–800 nm |
| Flow Rate Range | 0–30 mL/min, 0–100 mL/min, 0–300 mL/min |
| Column Options | 16 mm, 26 mm, 50 mm ID |
| Valve Configurations | Single-column (forward/reverse/bypass), 6-position multi-column selector valve |
| Pressure Monitoring | Pre- and post-column |
| Fraction Collection | 2-channel or 8-channel fraction collector |
| Solvent Selection | 2-, 6-, or 8-channel solvent selector valve |
| Injection | Auto-sampling valve + sample pump + mobile phase inlet valve |
| UV Detection Channels | Dual-channel or quad-channel |
| Software Compliance | GLP, GMP, FDA 21 CFR Part 11 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Bio-Pro 60 |
| Price Range | USD $135,000 – $205,000 (FOB China) |
| Purification Principle | Liquid Chromatography (LC) with Multi-Parameter Process Monitoring |
| Detector Types | UV-Vis, pH, Conductivity |
| UV Detection Range | 200–400 nm |
| Surface Finish | Electropolished Tubing (Ra ≤ 0.4 µm) |
| Compliance | ASME BPE-2023, USP Class VI, FDA 21 CFR Part 11, GMP Annex 15 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MCC-Q100 |
| Purification Principle | Gravity- or Pressure-Driven Manual Chromatography |
| Column Tube Material | Schott D263 Borosilicate Glass |
| Sealing Mechanism | Pneumatically Assisted Automatic Sealing (Q-Series) |
| Flow Path Design | Dead-Volume-Free |
| Wetted Materials Compliance | ASME BPE-2023 Compliant |
| Validation Support | Full GMP Documentation Package Available |
| Column Diameter Range | 100 mm (Standard) |
| Max Operating Pressure | ≤ 3 bar (Manual Compression System) |
| Cleaning & Sterilization | CIP/SIP Compatible |
| Column Head Design | Laterally Sliding, Tool-Free Adjustment |
| Bottom Screen Replacement | Hot-Swap Capable Without Column Disassembly |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-EzPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Temperature Control Range | 15–40 °C, Accuracy: ±0.1 °C, Stability: ±0.01 °C |
| Detection Limit | 5 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 150 ng/mL (for 100–1000 kDa) to 5 µg/mL (for 4–20 kDa) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-OpenPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Detection Limit | 10 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 300 ng/mL (for 100–1000 kDa) to 10 µg/mL (for 4–20 kDa) |
| Temperature Control | Not specified in input |
| Compliance | CE-marked, compatible with GLP/GMP workflows requiring audit trails and instrument qualification |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | Acoulyte |
| Sensor Diameter | 14 mm |
| Substrate | SiO₂-coated QCM-D crystal |
| Sensing Surface | Nanostructured gold |
| Standard Coatings | Si₃N₄, SiO₂, Al₂O₃, TiO₂ |
| Light Source | Tungsten-halogen lamp |
| Wavelength Range | 450–1000 nm |
| LSPR Sensitivity | ≤0.03 monolayer |
| Measurement Spot Diameter | 3 mm |
| Temporal Resolution | 10 Hz (10 samples/s) |
| Typical Noise Level | <0.01 nm |
| Optical Unit Dimensions (W×D×H) | 25×27×9 cm |
| Acoulyte Module Dimensions (W×D×H) | 8×5×3 cm |
| Software | Insplorer (Windows-compatible) |
| Data Export Format | ASCII text |
| Compatible Platforms | Q-Sense Explorer E1 & Analyzer E4 (with Q-Sense Window Module) |
| NPS Sensing Depth | <30 nm |
| QCM-D Hydrodynamic Penetration Depth | >300 nm |
| Simultaneous Output Parameters | LSPR resonance wavelength shift (Δλ), extinction intensity change, frequency shift (Δf), dissipation change (ΔD) |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS Sensor Chip |
| Pricing | Upon Request |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | S2 |
| Analysis Time | 2 s |
| Temperature Control Range | 15 °C–45 °C (±0.1 °C stability) |
| Flow Cell | Dual-channel |
| Sample Dead Volume | 20 µL |
| Standard Syringe Volume | 250 µL |
| Typical Flow Rate | 12.5–250 µL/min |
| Standard Loop Volume | 200 µL |
| Sensor Substrate | Fused Silica |
| Sensing Layer | Nanostructured Gold |
| Detection Depth | Up to 30 nm |
| Light Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Measurement Spot Diameter | 1.5 mm |
| Temporal Resolution | Up to 10 Hz |
| Optical Noise | <0.1 nm (at 1 Hz sampling) |
| Sensor Dimensions | 9.5 × 9.5 × 1 mm |
| System Dimensions | 65 × 42 × 36 cm |
| Weight | 30 kg |
| Software | InControl 1.0 (Windows-compatible) |
| Data Output | Proprietary CSV/TSV format |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | XNano |
| Measurement Principle | Nanoplasmonic Resonance Spectroscopy (NPS) |
| Sample Environment | Liquid or Gas Flow |
| Temperature Range | 25–80 °C (optional up to 250 °C) |
| Chip Substrate | Fused Silica (9.5 × 9.5 × 1 mm) |
| Sensing Surface | Nanostructured Gold |
| Coating Options | Au, SiO₂, Si₃N₄, TiO₂, Al₂O₃ |
| Optical Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Wavelength Range | 450–1000 nm |
| Spot Size | ~2 mm diameter |
| Time Resolution | 10 Hz (10 samples/sec) |
| Noise Level | < 0.01 nm (in liquid, 1 Hz sampling) |
| Flow Cell Volume | ~4 μL |
| Minimum Sample Volume | ~100 μL |
| Typical Flow Rate | 20–100 μL/min |
| Materials | Titanium & Perfluoroelastomer® |
| Dimensions (Measurement Unit) | 31 × 25 × 25 cm |
| Software | Windows-compatible, ASCII output, multi-parameter real-time export (resonance wavelength, linewidth, extinction) |