Empowering Scientific Discovery

Pumai Jingyi Technology (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZENTA
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelA220
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZENTA
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelCryo Store Pico
Application FieldBiopharmaceuticals
Dimensions108.5 × 144.2 × 241.5 cm (3'6" × 4'8" × 7'11")
Cryo Chamber Volume802 L
Vial Capacity8,800 (at standard 2D barcode-labeled cryovials)
Storage EnvironmentStable vapor-phase LN₂ at –190°C
Temperature Stability During Utility Failure≥48 hours (LN₂ + power loss)
Regulatory ComplianceFDA 21 CFR Part 11–compliant audit trail, LIMS-integrated inventory management, GLP/GMP-ready data integrity architecture
Software PlatformAZENTA CryoControl™ v5.x with touchscreen HMI, real-time environmental logging, and sample-level traceability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAZENTA (formerly Brooks Life Sciences)
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelBiocision Cryopod™
Price RangeUSD $2,500 – $6,200
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzenta (formerly Brooks Life Sciences)
OriginUSA
ModelBioStore III Cryo (B3C)
Weight1067 kg
Operating Temperature-190°C (vapor-phase LN₂)
Static LN₂ Consumption~9.5–12.5 L/day
Sample Retention at >-135°C (Tg) During LN₂ Interruption≥21 days
Capacity63,000 × 2 mL tubes or 123,000 × 1 mL tubes
Footprint42 in (107 cm) wide
Regulatory ClassificationAtmospheric-pressure cryogenic storage system (non-pressure vessel)
ComplianceDesigned for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11-compliant audit trails
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAzenta
OriginUSA
ModelB3C 1500
Temperature Range-190°C (vapor-phase liquid nitrogen)
Static LN₂ Consumption~9.5–12.5 L/day
Thermal Hold Time (Power Loss)~21 days
Operation ModeFully Automated with Manual Override Capability
ComplianceDesigned for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11–compliant audit trails via integrated software
Footprint OptionsConfigurable modular layouts (standard, double-height, quad-height, and ultra-capacity variants available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAir Liquide China
OriginFrance
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelVOYAGEUR2
PricingUpon Request
Effective Volume1.75 L
Absorbed LN₂ Capacity1.35 L
Neck Opening Diameter30 mm
Empty Weight2.4 kg
Full Weight3.5 kg
External Diameter174 mm
Total Height395 mm
Daily Evaporation Rate0.1 L/day
Dynamic Holding Time8 days
Cryovial Capacity (0.25 mL)220 straws
Cryovial Capacity (0.5 mL)100 straws
2 mL Vial Capacity (on rods)84 vials
5 mL Vial Capacity (on rods)42 vials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAir Liquide
OriginFrance
ModelGT14/6
Capacity14 L
Empty Weight~12.5 kg (typical for GT14/6)
Static Hold Time≥21 days (at 20°C ambient)
Neck Diameter50 mm
Inner Vessel MaterialStainless Steel 304
Outer Shell MaterialAnodized Aluminum Alloy
InsulationMulti-layer reflective foil + vacuum gap
ComplianceISO 9001:2000 certified
Transport CertifiedADR/RID/IATA compliant