- All
- Favorite
- Popular
- Most rated
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A220 |
| Pricing | Upon Request |
| Brand | Azenta |
|---|---|
| Origin | USA |
| Model | IntelliXcap™ |
| Throughput | 24/48/96-well format |
| Cap Operation Time (full plate) | 20 s |
| Continuous Operation Duration | 5–6 hours |
| Dimensions (H×W×D) | 386.2 × 256 × 464.4 mm (24/48) / 320 × 256 × 468 mm (96) |
| Weight | 27.96 kg (24), 28.74 kg (48), 26.80 kg (96) |
| Operating Temperature | 5–40 °C |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Sapphire NIR-Q |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| CCD Resolution | 6.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–6 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | fg-level protein |
| Signal-to-Noise Ratio | ≥72 dB |
| Lens | Motorized Autofocus |
| Brand | AZENTA |
|---|---|
| Origin | United Kingdom |
| Model | IntelliXcap M6 |
| Channel Count | 6 |
| Full 48-Well Plate Decapping Time | ≤10 s |
| Full 48-Well Plate Capping Time | ≤2 min |
| Power Source | Rechargeable Battery |
| Compatible Format | SBS-48 Standard Microplate Footprint |
| Tube Volume Compatibility | 1.5 mL, 1.9 mL, and 3.8 mL Cryovials (AZENTA-branded) |
| Actuation Mechanism | Independent Spring-Loaded Torque-Controlled Capping System |
| Dimensions | Compact, Ergonomic Handheld Form Factor |
| Regulatory Alignment | Designed for GLP-compliant laboratory environments |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Sapphire |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| CCD Resolution | 6.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–6 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | fg-level protein |
| Signal-to-Noise Ratio | ≥72 dB |
| Lens | Motorized Autofocus |
| Excitation Sources | Four Solid-State Lasers (488 nm, 520 nm, 658 nm, 785 nm) |
| Detection Modalities | PMT (blue/chemiluminescence/phosphorimaging), APD (green/red/NIR), CCD (high-sensitivity chemiluminescence/visible) |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Cryo Store Pico |
| Application Field | Biopharmaceuticals |
| Dimensions | 108.5 × 144.2 × 241.5 cm (3'6" × 4'8" × 7'11") |
| Cryo Chamber Volume | 802 L |
| Vial Capacity | 8,800 (at standard 2D barcode-labeled cryovials) |
| Storage Environment | Stable vapor-phase LN₂ at –190°C |
| Temperature Stability During Utility Failure | ≥48 hours (LN₂ + power loss) |
| Regulatory Compliance | FDA 21 CFR Part 11–compliant audit trail, LIMS-integrated inventory management, GLP/GMP-ready data integrity architecture |
| Software Platform | AZENTA CryoControl™ v5.x with touchscreen HMI, real-time environmental logging, and sample-level traceability |
| Brand | AZENTA |
|---|---|
| Country of Origin | Germany |
| Model | Barkey Plasmatherm |
| Power Supply | 230 V / 50 Hz |
| Temperature Range | 25–45 °C (standard mode) |
| Dimensions (L×W×H) | 60 × 34 × 32 cm |
| Net Weight | 18 kg |
| Max. Chamber Volume | 9 L |
| Certifications | CE 0120, China NMPA Import Registration No. 20162451979, ISO 9001, ISO 13485 |
| Compliance | FDA 21 CFR Part 606.122 (Blood & Blood Components), GLP/GMP-ready |
| Interface Options | RS232, Ethernet (for TCP Logging Tool), Barcode Reader, Log Printer |
| Safety Features | Dual independent thermal fuses, liquid leakage sensor, audible/visual end-of-cycle alert, self-test at power-on |
| Heating Technology | Dry-contact conductive heating (no water bath, no direct fluid contact) |
| Brand | Azenta Brooks FluidX |
|---|---|
| Origin | Japan |
| Model | 66-9302 |
| Capacity | 7.6 mL (24-well format), 1.9 mL / 1.5 mL / 1.0 mL / 0.5 mL / 0.26 mL (48/96-well formats) |
| Material | Virgin polypropylene (PP) |
| Sterilization | Gamma-irradiated (optional) |
| Temperature Range | -196 °C to +121 °C |
| Thread Type | External thread |
| Max. Centrifugation | 20,000 × g |
| Compliance | ISO 15189, ISO/IEC 17025, FDA 21 CFR Part 11 (software-integrated workflows), GLP/GMP-ready |
| Brand | AZENTA (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Biocision Cryopod™ |
| Price Range | USD $2,500 – $6,200 |
| Brand | Azenta Brooks FluidX |
|---|---|
| Origin | Japan |
| Model | 66-62325-Y6 |
| Volume Options | 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL (internal/external thread), 2.2 mL (external thread) |
| Format | 96-well SBS-compliant or 24-well for tissue tubes |
| Material | Virgin polypropylene (PP) |
| Max Operating Temperature | −196 °C (liquid nitrogen vapor phase only) |
| Cap Types | Automation-friendly screw caps with silicone O-rings or TPE septa |
| Tube Base | Permanently laser-etched 2D QR code + human-readable numeric ID |
| Rack Compatibility | LowBase/HighBase SBS racks, TwistLock/TubeLock/LidLock-enabled PC cryo-racks (14×14, 7×7) |
| Compliance | ASTM F2668, ISO 20365, USP <665>, GLP/GMP traceability ready |
| Brand | Azenta (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Biobanking Infrastructure Systems |
| Temperature Ranges | RT to –20°C, –80°C, –150°C (Vario), –196°C (Cryo) |
| Automation Level | Fully Automated Sample Storage & Retrieval |
| Compliance | Designed for GLP/GMP-aligned biorepository operations, 21 CFR Part 11–ready software architecture |
| Dimensions (BioStore II –80°C, Quad-height) | 12.77 m × 2.78 m × 3.04 m |
| Dimensions (BioStore III Cryo –196°C, Ultra-high capacity) | 18.17 m × 4.78 m × 3.24 m |
| LN₂ Consumption (BioStore III Cryo, static) | ~9.5–12.5 L/day |
| Temperature Hold Time (fail-safe) | ≥21 days at –190°C after power loss |
| Brand | Azenta (formerly Brooks Life Sciences) |
|---|---|
| Origin | USA |
| Model | BioStore III Cryo (B3C) |
| Weight | 1067 kg |
| Operating Temperature | -190°C (vapor-phase LN₂) |
| Static LN₂ Consumption | ~9.5–12.5 L/day |
| Sample Retention at >-135°C (Tg) During LN₂ Interruption | ≥21 days |
| Capacity | 63,000 × 2 mL tubes or 123,000 × 1 mL tubes |
| Footprint | 42 in (107 cm) wide |
| Regulatory Classification | Atmospheric-pressure cryogenic storage system (non-pressure vessel) |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11-compliant audit trails |
| Brand | Azenta |
|---|---|
| Origin | USA |
| Model | B3C 1500 |
| Temperature Range | -190°C (vapor-phase liquid nitrogen) |
| Static LN₂ Consumption | ~9.5–12.5 L/day |
| Thermal Hold Time (Power Loss) | ~21 days |
| Operation Mode | Fully Automated with Manual Override Capability |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11–compliant audit trails via integrated software |
| Footprint Options | Configurable modular layouts (standard, double-height, quad-height, and ultra-capacity variants available) |
| Brand | Air Liquide China |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | VOYAGEUR2 |
| Pricing | Upon Request |
| Effective Volume | 1.75 L |
| Absorbed LN₂ Capacity | 1.35 L |
| Neck Opening Diameter | 30 mm |
| Empty Weight | 2.4 kg |
| Full Weight | 3.5 kg |
| External Diameter | 174 mm |
| Total Height | 395 mm |
| Daily Evaporation Rate | 0.1 L/day |
| Dynamic Holding Time | 8 days |
| Cryovial Capacity (0.25 mL) | 220 straws |
| Cryovial Capacity (0.5 mL) | 100 straws |
| 2 mL Vial Capacity (on rods) | 84 vials |
| 5 mL Vial Capacity (on rods) | 42 vials |
| Brand | Air Liquide |
|---|---|
| Origin | France |
| Model | GT14/6 |
| Capacity | 14 L |
| Empty Weight | ~12.5 kg (typical for GT14/6) |
| Static Hold Time | ≥21 days (at 20°C ambient) |
| Neck Diameter | 50 mm |
| Inner Vessel Material | Stainless Steel 304 |
| Outer Shell Material | Anodized Aluminum Alloy |
| Insulation | Multi-layer reflective foil + vacuum gap |
| Compliance | ISO 9001:2000 certified |
| Transport Certified | ADR/RID/IATA compliant |
| Brand | 4titude |
|---|---|
| Origin | Taiwan |
| Model | A4s |
| Automation Level | Fully Automatic |
| Sealing Capacity | Up to 5,000 cycles unattended |
| Seal Cycle Time | <15 s |
| Sealing Temperature Range | 100–195 °C |
| Sealing Time Range | 0.1–10 s |
| Dimensions (W×L×H) | 230 × 507 × 276 mm |
| Weight (without film roll) | 27 kg |
| Power Input | AC 100–240 V, DC 24 V / 320 W |
| Max Power Consumption | 700 W |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 0–85% RH |
| Interface | RS-232, USB |
| Compliance | SiLA 2.0 compatible, SBS-compliant footprint support (96–1536-well), GLP/GMP-ready audit trail via software logging |
| Brand | 4titude |
|---|---|
| Origin | USA |
| Model | 4titude® TubeMarker 2 |
| Printing Technology | Thermal pixel printing |
| Tube Diameter Range | 6–30 mm |
| Tube Volume Compatibility | 0.2 mL to 50 mL |
| Operating Temperature Range | −196 °C to +100 °C |
| Chemical Resistance | Ethanol (70%), isopropanol (70%), methanol (>98.5%), DMSO, liquid nitrogen, water, mechanical abrasion |
| Print Media | Polypropylene (PP), polyethylene (PE), and other smooth-surface plastic tubes |
| Supported Codes | 1D linear barcodes (Code 128, Code 39), 2D DataMatrix, monochrome graphics (.bmp, .gif, .tiff) |
| Font Support | Full TrueType font library with adjustable size, bold/italic formatting |
| Print Orientation | Horizontal or vertical (barcodes vertical only) |
| Data Import | Microsoft Excel (.xls, .xlsx, .csv) |
| Automation | Auto-sensing tube detection with delayed print trigger |
| Ribbon Capacity | 300 m per roll (≥100,000 prints at 3 mm width) |
| Standard Adapters Included | 8.5 mm, 11.5 mm, 12.7 mm internal diameter |
| Compliance | Designed for GLP/GMP-aligned lab workflows |
| Brand | 4titude |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Asia-Pacific Manufactured |
| Model | XP-A_230V |
| Pricing | Available Upon Request |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | YSI 2500 |
| Measurement Volume | 10–50 µL |
| Analysis Time | 60 s |
| Precision | CV < 2% |
| Linearity Deviation | ±5% |
| Temperature Range | 15–35 °C |
| Relative Humidity | 10–90% RH |
| Power Supply | 220–240 VAC, 50–60 Hz, 50 W |
| Dimensions | 20.3 cm (W) × 52.1 cm (D) × 40.0 cm (H) |
| Weight | 12.7 kg (excl. bottle rack) |
| Compliance | CE, RoHS |
| Sample Formats | Single samples, 8-tube strips, 24-well & 96-well microplates |
| Automation Capacity | Up to 96 samples per run |
| Auto-calibration | Yes |
| Temperature Compensation | Yes |
| Liquid Level Detection | Yes |
| Sensor Principle | Enzyme-membrane amperometry (glucose, lactate, glutamine, etc.) + ion-selective electrodes (NH₄⁺, K⁺) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioMIX1 |
| Speed Range | 2–250 rpm |
| Stirring Capacity | 5–5000 mL |
| Power Consumption | 6 W |
| Operating Temperature | −10 to 50 °C (up to 80% RH) |
| Enclosure Material | Stainless Steel (IP64) |
| Dimensions (W×D×H) | 180×230×38 mm |
| Weight | 1.4 kg |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Control Unit | Integrated Display & Drive |
| Brand | AZENTA (formerly Ziath) |
|---|---|
| Origin | Germany |
| Model | Mirage Connect |
| Dimensions | 208 × 135 × 80 mm |
| Weight | 1.35 kg |
| Power Input | 100–240 VAC, USB-C powered |
| Power Consumption | ≤10 W |
| Camera | 16 MP autofocus imaging system |
| Decoding Time | <2 seconds per plate |
| Compatible Formats | ISO/IEC 16022 DataMatrix (2D), optional barcode module for 1D symbologies |
| Supported Storage Formats | 24-, 48-, 96-, 138HD-, 240-, and 384-well cryoboxes |
| Operating Temperature | 5–35 °C |
| Compliance | GxP, FDA 21 CFR Part 11 (with DP5 software audit trail), IVDR, ISO 20387 (Biobanking) |
| Connectivity | Dual-mode RJ45 Ethernet (HTTP/HTTPS REST API) and USB-C interface |
| Software Platform | DP5 v5.x with LIMS integration, mobile app control, and centralized fleet management via LAN/WAN |
| Warranty | 2 years |
| Brand | AZENTA (formerly Anserad) |
|---|---|
| Origin | United Kingdom |
| Device Type | Handheld 2D/1D Barcode Reader for Sample Tube Tracking |
| Dimensions | 155 × 65 × 38 mm (L×W×D) |
| Weight | 150 g |
| Power Input (Charger) | 100–240 VAC, 50/60 Hz, 260 mA |
| Output (Charger) | 5 VDC, 2.4 A |
| Battery Life | Up to 8 hours per charge |
| Onboard Storage Capacity | Up to 60,000 barcode records |
| Communication | USB-Cable or Bluetooth v4.2+ |
| Operating Temperature Range (with optional Cryo-Protection Module) | −20 °C to +40 °C |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Monad |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BlotEZ |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ASA-9600 |
| Price Range | USD 14,000–42,000 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | Avg. ≥1.5 °C/s, Max. ≥2.5 °C/s |
| Temperature Accuracy | ≤±0.5 °C |
| Well-to-Well Temperature Uniformity | ≤±1.0 °C |
| Cooling Rate | Avg. ≥1.5 °C/s, Max. ≥2.0 °C/s |
| Temperature Range | 4–99 °C |
| Lid Temperature | 104 °C |
| Excitation Wavelength Range | 380–780 nm |
| Emission Detection Channels | Up to 5 excitation + 5 emission filters |
| Fluorescence Detection Reproducibility (CV) | ≤3% |
| Inter-channel Crosstalk | Target-channel threshold not exceeded by adjacent channel signal |
| Linearity (R²) | ≥0.990 for fluorescence, ≥0.980 for sample concentration |
| Dynamic Range | 10 orders of magnitude |
Show next